Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Optimizing galaxy samples for clustering measurements in photometric surveys

When analysing galaxy clustering in multiband imaging surveys, there is a trade-off between selecting the largest galaxy samples (to minimize the shot noise) and selecting samples with the best photometric redshift (photo-$z$) precision, which generally includes only a small subset of galaxies. In this paper, we systematically explore this trade-off. Our analysis is targeted towards the third-year data of the Dark Energy Survey (DES), but our methods hold generally for other data sets. Using a simple Gaussian model for the redshift uncertainties, we carry out a Fisher matrix forecast for cosmological constraints from angular clustering in the redshift range $z$ = 0.2–0.95. We quantify the cosmological constraints using a figure of merit (FoM) that measures the combined constraints on $Ωm$ and $σ_8$ in the context of Λ cold dark matter ($Λ$CDM) cosmology. We find that the trade-off between sample size and photo-z precision is sensitive to (1) whether cross-correlations between redshift bins are included or not, and (2) the ratio of the redshift bin width $δz$ to the photo-$z$ precision $σ_z$. When cross-correlations are included and the redshift bin width is allowed to vary, the highest FoM is achieved when $δz$ ~ $σ_z$. We find that for the typical case of 5-10 redshift bins, optimal results are reached when we use larger, less precise photo-z samples, provided that we include cross-correlations. For samples with higher $σ_z$, the overlap between redshift bins is larger, leading to higher cross-correlation amplitudes. This leads to the self-calibration of the photo-z parameters and therefore tighter cosmological constraints. These results can be used to help guide galaxy sample selection for clustering analysis in ongoing and future photometric surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-I-100: Heterogeneity Studying for Primary and Lymphoma Tumors by Using Multi-Scale Image Texture Analysis with PET-CT Images

Purpose: The purpose of this research is studying tumor heterogeneity of the primary and lymphoma by using multi-scale texture analysis with PET-CT images, where the tumor heterogeneity is expressed by texture features. Methods: Datasets were collected from 12 lung cancer patients, and both of primary and lymphoma tumors were detected with all these patients. All patients underwent whole-body 18F-FDG PET/CT scan before treatment.The regions of interest (ROI) of primary and lymphoma tumor were contoured by experienced clinical doctors. Then the ROI of primary and lymphoma tumor is extracted automatically by using Matlab software. According to the geometry size of contour structure, the images of tumor are decomposed by multi-scale method.Wavelet transform was performed on ROI structures within images by L layers sampling, and then wavelet sub-bands which have the same size of the original image are obtained. The number of sub-bands is 3L+1.The gray level co-occurrence matrix (GLCM) is calculated within different sub-bands, thenenergy, inertia, correlation and gray in-homogeneity were extracted from GLCM.Finally, heterogeneity statistical analysis was studied for primary and lymphoma tumor using the texture features. Results: Energy, inertia, correlation and gray in-homogeneity are calculated with our experiments for heterogeneity statistical analysis.Energy for primary and lymphomatumor is equal with the same patient, while gray in-homogeneity and inertia of primaryare 2.59595±0.00855, 0.6439±0.0007 respectively. Gray in-homogeneity and inertia of lymphoma are 2.60115±0.00635, 0.64435±0.00055 respectively. The experiments showed that the volume of lymphoma is smaller than primary tumor, but thegray in-homogeneity and inertia were higher than primary tumor with the same patient, and the correlation with lymphoma tumors is zero, while the correlation with primary tumor isslightly strong. Conclusion: This studying showed that there were effective heterogeneity differences between primary and lymphoma tumor by multi-scale image texture analysis. This work is supported by National Natural Science Foundation of China (No. 61201441), Research Fund for Excellent Young and Middle-aged Scientists of Shandong Province (No. BS2012DX038), Project of Shandong Province Higher Educational Science and Technology Program (No. J12LN23), Jinan youth science and technology star (No.20120109)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermoelectric performance of nanostructured p-type Zr₀.₅Hf₀.₅Co₀.₄Rh₀.₆Sb 1–x Sn x half-Heusler alloys

Several compositions of the p-type half-Heusler alloys Zr₀.₅Hf₀.₅Co₀.₄Rh₀.₆Sb 1–x Sn x (0≤x≤0.4) were synthesized by mechanically alloying high purity elemental powders using hardened steel jars and balls on a high energy shaker mill. Powder X-ray diffraction (XRD) investigations of several aliquots taken after regularly spaced milling time suggested that single phase products with half-Heusler (HH) structure can be obtained after 10 h. However, XRD and transmission electron microscopy (TEM) studies of several specimens obtained from compacted polycrystalline powders of Z₀.₅Hf₀.₅Co₀.₄Rh₀.₆Sb 1–x Sn x alloys using a uniaxial hot press (HP) revealed the presence of CoSb inclusions with various sizes embedded inside the HH matrix. Hall effect, electrical conductivity, and thermopower data collected between 300 K and 775 K on several compositions suggested that electronic transport in the synthesized Zr₀.₅Hf₀.₅Co₀.₄Rh₀.₆Sb 1–x Sn x /CoSb composites strongly depends on the average size and/or mole fraction of the embedded CoSb inclusions rather than the fraction (x) of Sn substituting for Sb. Among the samples investigated, the nanocomposite with x=0.2, which contains nanometer-scale CoSb inclusions, showed the largest power factor (800 μW/K² m at 775 K) and the lowest lattice thermal conductivity (~2.2 W/m K at 775 K) leading to a six-fold enhancement in the figure of merit when compared to the Zr₀.₅Hf₀.₅Co₀.₄Rh₀.₆Sb₀.₉₉Sn₀.₀₁ bulk matrix. - Graphical abstract: CoSb nanoinclusions embedded into a p-type Zr₀.₅Hf₀.₅Co₀.₄Rh₀.₆Sb 1–x Sn x half-Heusler matrix simultaneously boost the thermopower and carrier mobility leading to a drastic enhancement of the power factor of the resulting bulk nanostructured materials. Highlights: • The phase composition of half-Heusler (HH) alloy is very sensitive to the synthesis method. • Mechanical alloying (MA) of elements results in bulk HH matrix with CoSb inclusions. • CoSb nanoinclusions simultaneously boost the thermopower and carrier mobility with the HH matrix. • The MA process reduces lattice thermal conductivity due to high density of grain boundaries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electric Plasma Arc-Lamp Combustor Liner Durability Test System Developed

Silicon carbide matrix composites are candidate materials for high-temperature combustor liners. Because through-the-thickness thermal gradients are the primary cause of stress on combustor liners, a unique test facility was developed at the NASA Glenn Research Center at Lewis Field to simulate in-service pure thermal stress distributions in fiber reinforced silicon carbide cylinders. It was developed initially under Phase II of the High- Speed Research Program. This test stand can accommodate 8-in.-long test cylinders that have outer diameters of 4 in. and a wall thickness of about 0.08 to 0.12 in. One cylinder at a time is loaded vertically into the test stand. Water-cooled plates enclose the open ends of the cylinder and provide cooling. Load plates on the exterior side of the water-cooled plates provide support and compression loads. To evaluate a combustor liner material s potential performance, researchers induce thermal gradients with an axisymmetric, direct-current, electric arc within the cylinder while refrigerated air at a rate of 1.5 lb/sec impinges on the outside surface of the cylinder. The achievable through-the-thickness thermal gradient is predicted to be in excess of 200 C. The 8-in. long, 0.5-in.-diameter plasma arc emits full spectrum visible light; radiant intensity exceeds 300 Watts per square centimeters to produce temperatures in excess of 1500 C on materials with emissivity near unity. Because the system does not rely upon the combustion of fuels to achieve the related thermal conditions, ancillary environmental reactions with the sample are eliminated. The system incorporates a standard mechanical test frame, which can impose constant as well cyclical axial stresses up to 2200 lb upon the test piece. Silicon-carbide-fiber reinforced silicon carbide matrix composite cylinders were instrumented with thin-film thermocouples to obtain through-the-thickness thermal flux measurements. Inside wall temperatures reached 1200 C with only 250 A of current. One of the special features of this configuration is the creation of hoop stress states within the cylinder, which up this point have not been obtainable in planar coupon tests. This facility will allow various operational modes, including accelerated tests of thermal transients simulating the effects of repeated engine ignition as well as prescribed thermal and mechanical histories to simulate various duty cycle profiles. Tests can now be performed on thermal-barrier-coated metallic liners and ceramic composite liners that require a combination of high heat flux and controlled mechanical stresses.

Goldsby, Jon C.↗

Influence of High Pulsed Magnetic Field on the Dislocations and Mechanical Properties of Al{sub 2}O{sub 3}/Al Composites

At T6 state, Al–Zn–Mg–Cu aluminum matrix composites reinforced with Al{sub 2}O{sub 3} particles generated in situ were subjected to high pulsed magnetic fields at different magnetic induction intensities (B = 2, 3 and 4 T). The results show that the dislocation densities in the treated samples increased with increasing B, and the magnetoplastic effect was determined to be the primary cause. The effect of the magnetic field is believed to alter the spin state of free electrons between dislocations and obstacles from the singlet state (associated with high bonding energy) to the triplet state (low bonding energy). The maximum ultimate tensile strength of 532 MPa was obtained at B = 4 T with 30 pulses, which was 20.7% higher than that of the initial sample, primarily because of dislocation strengthening. At B = 2 T, the elongation was at its maximum of 9.3%, representing an increase of 12% compared with the initial sample, while the associated ultimate tensile strength (447 MPa) was still higher than that of the untreated sample (440 MPa). The relationship between mechanical properties and microstructure was analyzed, and the improved properties observed in this work are explained by the transition of the electron spin state and the piling up of dislocations.

36 MATERIALS SCIENCE↗

Multivariate Analysis of MALDI Imaging Mass Spectrometry Data of Mixtures of Single Pollen Grains

Mixtures of pollen grains of three different species (Corylus avellana, Alnus cordata, and Pinus sylvestris) were investigated by matrix-assisted laser desorption/ionization time-of-flight imaging mass spectrometry (MALDI-TOF imaging MS). The amount of pollen grains was reduced stepwise from > 10 to single pollen grains. For sample pretreatment, we modified a previously applied approach, where any additional extraction steps were omitted. Our results show that characteristic pollen MALDI mass spectra can be obtained from a single pollen grain, which is the prerequisite for a reliable pollen classification in practical applications. MALDI imaging of laterally resolved pollen grains provides additional information by reducing the complexity of the MS spectra of mixtures, where frequently peak discrimination is observed. Combined with multivariate statistical analyses, such as principal component analysis (PCA), our approach offers the chance for a fast and reliable identification of individual pollen grains by mass spectrometry. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated thermal extraction-desorption gas chromatography mass spectrometry: A multifunctional tool for comprehensive characterization of polymers and their degradation products

The TED-GC–MS analysis is a two-step method. A sample is first decomposed in a thermogravimetric analyzer (TGA) and the gaseous decomposition products are then trapped on a solid-phase adsorber. Subsequently, the solid-phase adsorber is analyzed with thermal desorption gas chromatography mass spectrometry (TDU-GC–MS). This method is ideally suited for the analysis of polymers and their degradation processes. A new entirely automated system is introduced which enables high sample throughput and reproducible automated fractioned collection of decomposition products. The fractionated collection together with low temperatures reduces the risk of contamination, improves instrumental stability and minimizes maintenance efforts. Through variation of the two main parameters (purge gas flow and heating rate) it is shown how the extraction process can be optimized. By measuring the decomposition products of polyethylene it is demonstrated that compounds with masses of up to 434 Da can be detected. This is achieved despite the low temperature (˜40 °C) of the solid-phase adsorber and the low thermal desorption temperature of 200 °C in the TDU unit. It is now shown that automated TED-GC–MS represents a new flexible multi-functional method for comprehensive polymer analyses. Comparable polymer characterization was previously only achievable through a combination of multiple independent analytical methods. This is demonstrated by three examples focused on practical challenges in materials analysis and identification: The first one is the analysis of wood plastic composites for which the decomposition processes of the polymer and the bio polymer (wood) could be clearly distinguished by fractionated collection using sequential adsorbers. Secondly, a fast quantitative application is shown by determining the weight concentrations of an unknown polyolefin blend through comparison with a reference material. Additionally, the determination of microplastic concentrations in environmental samples is becoming an increasingly important analytical necessity. It is demonstrated that with TED-GC–MS calibration curves showing good linearity for the most important precursors for microplastic, even complex matrix materials (suspended particulate matter) can be successfully analyzed.

36 MATERIALS SCIENCE↗

Effect of thermal oxidation on helium implanted pure iron

The impact of thermal oxidation on Helium (He) implanted pure iron (Fe) was investigated to experimentally evaluate how thermal oxidation influences the diffusion and distribution of He within the material. In case of the sample with the lowest dose (2 × 10 17 ions/cm 2 ), the thinnest oxide layer was observed compared to the non-implanted pure Fe. It is due to He nano bubbles implanted in the material, which hinder the diffusion of Fe ions necessary for forming the oxide layer. For the medium dose sample (5 × 10 17 ions/cm 2 ), the oxide layer was slightly thicker than that of the lowest dose, however it had more porous structure due to the numerous nano He bubbles. In addition, a large bubble region around 150–200 nm depth was generated. Here, the highest dose sample (1 × 10 18 ions/cm 2 ) was observed that the escape of He was accelerated by the large amount of nano He bubbles from within the metal, forming a porous Fe matrix on the top surface and an oxide layer that is very porous but thicker than those of lower doses.

He implantation↗

Powder metallurgy processing and deformation characteristics of bulk multimodal nickel

Spark plasma sintering was used to process bulk nickel samples from a blend of three powder types. The resulting multimodal microstructure was made of coarse (average size ∼ 135 μm) spherical microcrystalline entities (the core) surrounded by a fine-grained matrix (average grain size ∼ 1.5 μm) or a thick rim (the shell) distinguishable from the matrix. Tensile tests revealed yield strength of ∼ 470 MPa that was accompanied by limited ductility (∼ 2.8% plastic strain). Microstructure observation after testing showed debonding at interfaces between the matrix and the coarse entities, but in many instances, shallow dimples within the rim were observed indicating local ductile events in the shell. Dislocation emission and annihilation at grain boundaries and twinning at crack tip were the main deformation mechanisms taking place within the fine-grained matrix as revealed by in-situ transmission electron microscopy. Estimation of the stress from loop's curvature and dislocation pile-up indicates that dislocation emission from grain boundaries and grain boundary overcoming largely contributes to the flow stress. - Highlights: • Bulk multi-modal Ni was processed by SPS from a powder blend. • Ultrafine-grained matrix or rim observed around spherical microcrystalline entities • Yield strength (470 MPa) and ductility (2.8% plastic strain) were measured. • Debonding was found at the matrix/microcrystalline entity interfaces. • In-situ TEM showed twinning, dislocation emission and annihilation at grain boundaries.

36 MATERIALS SCIENCE↗

Additive manufacturing of cobalt-based alloy on tool steel by directed energy deposition

Cladding hard-surfacing alloys on tool steel is an effective approach to enhance the surface properties of tool steel. In this study, a Co-based alloy was deposited on tool steel by Directed Energy Deposition (DED) following a three-factor three-level design of experiment matrix with varied laser power, scan speed, and powder flow rate. The microstructure of the deposits was characterized using scanning electron microscopy (SEM). The residual stress on the surface of the samples was measured by the X-ray diffraction (XRD) sin2? technique. The parameters that produced promising deposits were used to fabricate samples for tensile test, four-point bending test, Charpy impact test, and hardness measurement. Our result reveals that the processing parameters have a significant role in the residual stress of the coatings. Residual stress reduces with the increase of laser energy density. Cracks were found at samples with energy density below a threshold. Tensile testing of the coating/substrate combined structure reveals fracture at the coatings with an ultimate tensile strength of 633.9 ± 54.7 MPa. The bi-material interface survived the tensile test, indicating a strong interfacial bond. The four-point bending test of coating/substrate laminates shows an ultimate flexure strength of 860.6 ± 36.9 MPa. Cracks initiated from the coatings ignored the interface and penetrated the substrate, suggesting a solid bi-material bond. Charpy impact test shows the absorbed energy of coating/substrate laminates is more than doubled that of the substrate.

36 MATERIALS SCIENCE↗

Rate of CO 2 Attack on Hydrated Class H Well Cement under Geologic Sequestration Conditions

Experiments were conducted to study the degradation of hardened cement paste due to exposure to CO 2 and brine under geologic sequestration conditions (T = 50 degrees C and 30.3 MPa). The goal was to determine the rate of reaction of hydrated cement exposed to supercritical CO 2 and to CO 2 -saturated brine to assess the potential impact of degradation in existing wells on CO 2 storage integrity. Two different forms of chemical alteration were observed. The supercritical CO 2 alteration of cement was similar in process to cement in contact with atmospheric CO 2 (ordinary carbonation), while alteration of cement exposed to CO 2 -saturated brine was typical of acid attack on cement. Extrapolation of the hydrated cement alteration rate measured for I year indicates a penetration depth range of 1.00 +/- 0.07 mm for the CO 2 -saturated brine and 1.68 +/- 0.24 mm for the supercritical CO 2 after 30 years. These penetration depths are consistent with observations of field samples from an enhanced oil recovery site after 30 years of exposure to CO 2 -saturated brine under similar temperature and pressure conditions. These results suggest that significant degradation due to matrix diffusion of CO 2 in intact Class H neat hydrated cement is unlikely on time scales of decades.

54 ENVIRONMENTAL SCIENCES↗

Topology Controlled Supramolecular Self-Assembly of Octa Triphenylene-Substituted Polyhedral Oligomeric Silsesquioxane Hybrid Supermolecules

A series of liquid crystalline star supermolecules with polyhedral oligomeric silsesquioxane (POSS) as the central scaffold and eight triphenylenes (Tp) as the peripheral arms were synthesized via amidization reactions. The supermolecules were denoted as POSS(Tp){sub 8}. Six POSS(Tp){sub 8} samples were prepared with two alkyl chain lengths in the Tp (C{sub 5} and C{sub 12}) and three spacer lengths (C{sub 2}, C{sub 6}, and C{sub 10}) between the POSS core and the Tp arms. Three samples with C{sub 5}-Tp were amorphous because of too short alkyl chains in the Tp, while the other three samples with C{sub 12}-Tp self-assembled into hierarchical liquid crystalline mesophases, as studied by X-ray diffraction (XRD) and transmission electron microscopy (TEM). When the spacer length was C{sub 2}, a column-within-column super hexagonal columnar phase was observed, because the POSS core and the Tp arms were intimately coupled together. With increasing the spacer length to C{sub 6} and C{sub 10}, respectively, the POSS core and Tp arms became gradually decoupled. Alternating POSS-Tp lamellar morphology with a rectangular columnar symmetry (by XRD) was observed by TEM for the POSS(Tp){sub 8} sample with a C{sub 6}-spacer. For the POSS(Tp){sub 8} sample with a C{sub 10}-spacer, an oblique columnar phase was determined by XRD, and inverted columnar morphology with four Tp columns forming a super column within the POSS/alkyl chain matrix was observed by TEM. This study suggested that molecular topology played an important role in the supramolecular self-assembly of star-shaped POSS(Tp){sub 8} supermolecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spall behavior of cast iron with varying microstructures

The spall strength of cast iron with varying microstructures has been investigated using plate impact at moderate speed. Stress history measurements were made with manganin stress gauges embedded between the back face of the specimen and a low impedance polycarbonate backing. Five separate cast irons were tested. Four of these consisted of gray cast iron with graphite in flake form, with three classified as Type VII A2 and the fourth containing a bimodal distribution of Types VII A4 and VII D8. The fifth casting consisted of ductile cast iron with graphite in nodular form, classified as Type I, size class 5. The spall strength for the Type VII A2 gray cast irons varied between 40 and 370 MPa, and that of the additional gray cast iron, between 410 and 490 MPa. The spall strength of the ductile cast iron fell within the range of 0.94–1.2 GPa. It is shown that the spall strength is linked to the damage level at the spall plane, where an increased level of tensile stress is required to generate higher levels of damage. Post mortem analysis was performed on the recovered samples, revealing the graphite phase to be the primary factor governing the spall fracture of cast irons, where crack nucleation is directly correlated to the debonding of graphite from the metal matrix. The average length of graphite found within a casting is linked to the material's strength, where strength increases as a function of decreasing length. The morphology and mean free path of graphite precipitates further govern the subsequent coalescence of initiated cracks to form a complete fracture plane. In cases where graphite spacing is large, increased energy level is required to complete the fracture process. A secondary factor governing the spall fracture of cast irons has also been linked to the microstructure of the metal matrix, with pearlite yielding higher spall strengths than free ferrite.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-G-JeP4-13: Continuous Intra-Fractional Monitoring of the Prostate Using Dynamic KV Collimation and Tube Current Modulation

Purpose: The focus of this work is to improve the available kV image quality for continuous intra-fraction monitoring of the prostate. This is investigated using a novel blade collimation system enabling modulated volume-of-interest (VOI) imaging of prostate fiducial markers. Methods: A four-blade dynamic kV collimator was used to track a VOI during gantry rotation. Planar image quality was investigated as a function of collimator dimension, while maintaining the same dose to isocenter, for a 22.2 cm diameter cylindrical water phantom with a 9 mm diameter bone insert. A sample prostate anatomy was defined in the planning system, including three fiducial markers within the CTV. The VOI margin around each marker was set to be 2σ of the population covariance matrix characterizing prostate motion. DRRs were used to calculate the kV attenuation for each VOI as a function of angle. The optimal marker and tube current were determined using kV attenuation. Monte Carlo simulations were used to calculate the imaging dose to the phantom and MV scatter dose to the imaging panel. Results: Preliminary measurements show an increase in CNR by a factor of 1.3 with the VOI method, when decreasing from an 6×6 to 2×2 cm{sup 2} field. Attenuation calculations show a change in kV fluence at the detector by a factor of 21.6 with fiducial optimization; resultant tube current modulation increases maximum dose by a factor of 1.4 compared to no modulation. MV scatter contribution to the kV detector changes by approximately a factor of two over a complete gantry rotation. Conclusion: The dynamic collimation system allows single fiducial marker tracking at a very low dose, with reduction of scatter and improvement of image quality, compared to imaging the entire prostate. The approach is compatible with tube current modulation, which enables consistent image quality throughout the range of gantry rotation. This project was funded by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Development of Novel Method for Rapid Extract of Radionuclides from Solution using Polymer Ligand Film [Dissertation]

Accurate and fast determination of the activity of radionuclides in a sample is critical for nuclear forensics and emergency response. Radioanalytical techniques are well established for radionuclides measurement, however, they are slow and labor intensive, requiring extensive radiochemical separations and purification prior to analysis. With these limitations of current methods, there is great interest for a new technique to rapidly process samples. This dissertation describes a new analyte extraction medium called Polymer Ligand Film (PLF) developed to rapidly extract radionuclides. Polymer Ligand Film is a polymer medium with ligands incorporated in its matrix that selectively and rapidly extract analytes from a solution. The main focus of the new technique is to shorten and simplify the procedure necessary to chemically isolate radionuclides for determination by alpha spectrometry or beta counting.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Appendix A: Specimen 72275 documentation

The friability of the matrix of specimen 72275 caused numerous fragments and an abundance of fines to break away from the main mass during transport from the moon and handling in the lunar receiving laboratory. Samples 72275,1 to 72275,14 were labeled during PET examination. Samples 72275,1, 4, 6, 7, 8, and 9 were placed in storage, and the remainder were distributed.

Marvin, U. B.↗

Refine your search to explore more results.