Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Quantifying the Effect of Lidar Turbulence Error on Wind Power Prediction

Currently, cup anemometers on meteorological towers are used to measure wind speeds and turbulence intensity to make decisions about wind turbine class and site suitability; however, as modern turbine hub heights increase and wind energy expands to complex and remote sites, it becomes more difficult and costly to install meteorological towers at potential sites. As a result, remote-sensing devices (e.g., lidars) are now commonly used by wind farm managers and researchers to estimate the flow field at heights spanned by a turbine. Although lidars can accurately estimate mean wind speeds and wind directions, there is still a large amount of uncertainty surrounding the measurement of turbulence using these devices. Errors in lidar turbulence estimates are caused by a variety of factors, including instrument noise, volume averaging, and variance contamination, in which the magnitude of these factors is highly dependent on measurement height and atmospheric stability. As turbulence has a large impact on wind power production, errors in turbulence measurements will translate into errors in wind power prediction. The impact of using lidars rather than cup anemometers for wind power prediction must be understood if lidars are to be considered a viable alternative to cup anemometers.In this poster, the sensitivity of power prediction error to typical lidar turbulence measurement errors is assessed. Turbulence estimates from a vertically profiling WINDCUBE v2 lidar are compared to high-resolution sonic anemometer measurements at field sites in Oklahoma and Colorado to determine the degree of lidar turbulence error that can be expected under different atmospheric conditions. These errors are then incorporated into a power prediction model to estimate the sensitivity of power prediction error to turbulence measurement error. Power prediction models, including the standard binning method and a random forest method, were developed using data from the aeroelastic simulator FAST for a 1.5 MW turbine. The impact of lidar turbulence error on the predicted power from these different models is examined to determine the degree of turbulence measurement accuracy needed for accurate power prediction.

17 WIND ENERGY↗

Time domain-induced polarization geophysical data collected in the Rifle Floodplain, Colorado, USA

The IP data set was collected using a time domain-induced polarization (TDIP) method along 65 profiles of various lengths over the floodplain. Surface time domain?induced polarization (TDIP) data was collected to create the 3?D images of the complex electrical resistivity, in terms of magnitude and phase, which are associated with mineral precipitation and other lithological properties. The TDIP data was then used to estimate the spatial distribution of naturally reduced zones, which are known to be biogeochemical hotspots in floodplains having increased uranium and other redox-sensitive metal concentrations as well as high carbon contents. In the TDIP method, the transient decay of voltage is measured after current shut-off, typically in the form of an integral of decay curves over a predefined time window (so-called integral chargeability). TDIP measurements at the site were collected using the Syscal Iris Pro Switch equipment with a square-wave current injection, 50% duty cycle, and a pulse length of 2 s. The integral chargeability measurements were carried out using 20 windows during voltage decay between 240 and 1840 ms after current shut-off. Tomographic measurements were collected by deploying stainless steel electrodes with an electrode separation of 1.8 m and using a dipole-dipole ‘‘skip-2’’ and ‘‘skip-3’’ measuring protocol (i.e., for a dipoles length of 5.4 and 7.2 m, respectively). The sequence of dipole-dipole measurements was carefully arranged to (1) minimize unwanted electromagnetic coupling effects in the data, avoiding potential measurements with electrodes located inside the current dipole, (2) prevent voltage measurements using electrodes, which might be polarized due to previous current injection, and (3) increase the signal-to-noise ratio for an intended exploration depth of 8 m, i.e., the bottom of the aquifer. All measurements were collected as normal and reciprocal pairs for estimation of the data error. The IP measurements were collected with symmetric arrays (i.e., the measuring equipment placed at the center of the electrode array) with a maximum of 36 electrodes, considering that longer profiles revealed a significant increase in the normal-reciprocal misfit for the measurements of the decay curve, probably due to greater impact of electromagnetic coupling on the data. The TDIP data sets were inverted in a twodimensional domain along each transect using CRTomo, which is a smoothness-constraint inversion code based on a finite element algorithm. The resistivity and phase shift values at each pixel were then assigned at the corresponding point within the 3-D floodplain domain (the black rectangle Figure 1b) and used in the 3-D estimation. The TDIP inversion results provided the distribution of the complex resistivity, expressed in terms of its magnitude and phase-shift. The analysis of the normal-reciprocal misfit was used to estimate the relative error. We removed the measurement with smallest voltage difference (<2 mV), representing about 2% variations in the data. For the inversion of TDIP measurements, chargeability values were linearly converted to frequency domain phase values (at the fundamental frequency of 0.125 Hz), by assuming a constant-phase response. This approach has been demonstrated to provide consistent results in previous studies

54 ENVIRONMENTAL SCIENCES↗

Dependence of the compensation error on the error of a sensor and corrector in an adaptive optics phase-conjugating system

In the framework of a statistical model of an adaptive optics system (AOS) of phase conjugation, three algorithms based on an integrated mathematical approach are considered, each of them intended for minimisation of one of the following characteristics: the sensor error (in the case of an ideal corrector), the corrector error (in the case of ideal measurements) and the compensation error (with regard to discreteness and measurement noises and to incompleteness of a system of response functions of the corrector actuators). Functional and statistical relationships between the algorithms are studied and a relation is derived to ensure calculation of the mean-square compensation error as a function of the errors of the sensor and corrector with an accuracy better than 10%. Because in adjusting the AOS parameters, it is reasonable to proceed from the equality of the sensor and corrector errors, in the case the Hartmann sensor is used as a wavefront sensor, the required number of actuators in the absence of the noise component in the sensor error turns out 1.5 – 2.5 times less than the number of counts, and that difference grows with increasing measurement noise. (adaptive optics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-step retrace error calibration removing tilt ambiguity in coherence scanning interferometry

In interferometry measurement, the retrace error often limits its high-precision metrology applications. Retrace error calibration with tilted flats can give a relation between the retrace error and the introduced tilt angles, but there is still an ambiguity between the introduced tilt angles and the tilt terms in the created retrace error. Here, we propose a novel, to the best of our knowledge, two-step calibration method to resolve this tilt ambiguity. It involves additional measurements of spherical mirror(s) with known curvature(s). The experiment shows that the curvature deviation due to the tilt ambiguity can be significantly reduced after applying the proposed method.

36 MATERIALS SCIENCE↗

Skin Friction at Very High Reynolds Numbers in the National Transonic Facility

Skin friction coefficients were derived from measurements using standard measurement technologies on an axisymmetric cylinder in the NASA Langley National Transonic Facility (NTF) at Mach numbers from 0.2 to 0.85. The pressure gradient was nominally zero, the wall temperature was nominally adiabatic, and the ratio of boundary layer thickness to model diameter within the measurement region was 0.10 to 0.14, varying with distance along the model. Reynolds numbers based on momentum thicknesses ranged from 37,000 to 605,000. The measurements approximately doubled the range of available data for flat plate skin friction coefficients. Three different techniques were used to measure surface shear. The maximum error of Preston tube measurements was estimated to be 2.5 percent, while that of Clauser derived measurements was estimated to be approximately 5 percent. Direct measurements by skin friction balance proved to be subject to large errors and were not considered reliable.

Watson, Ralph D.↗

Pressure Measurements Using an Airborne Differential Absorption Lidar: Analysis of the Systematic Error Sources - Part 1

Remote airborne measurements of the vertical and horizontal structure of the atmospheric pressure field in the lower troposphere are made with an oxygen differential absorption lidar (DIAL). A detailed analysis of this measurement technique is provided which includes corrections for imprecise knowledge of the detector background level, the oxygen absorption fine parameters, and variations in the laser output energy. In addition, we analyze other possible sources of systematic errors including spectral effects related to aerosol and molecular scattering interference by rotational Raman scattering and interference by isotopic oxygen fines.

Flamant, Cyrille N.↗

Wavefront aberration measurements and corrections through thick tissue using fluorescent microsphere reference beacons

We present a new method to directly measure and correct the aberrations introduced when imaging through thick biological tissue. A Shack-Hartmann wavefront sensor is used to directly measure the wavefront error induced by a Drosophila embryo. The wavefront measurements are taken by seeding the embryo with fluorescent microspheres used as “artificial guide-stars.” The wavefront error is corrected in ten millisecond steps by applying the inverse to the wavefront error on a micro-electromechanical deformable mirror in the image path of the microscope. The results show that this new approach is capable of improving the Strehl ratio by 2 times on average and as high as 10 times when imaging through 100 µm of tissue. The results also show that the isoplanatic half-width is approximately 19 µm resulting in a corrected field of view 38 µm in diameter around the guide-star.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental measurement of structural power flow on an aircraft fuselage

An experimental technique is used to measure the structural power flow through an aircraft fuselage with the excitation near the wing attachment location. Because of the large number of measurements required to analyze the whole of an aircraft fuselage, it is necessary that a balance be achieved between the number of measurement transducers, the mounting of these transducers, and the accuracy of the measurements. Using four transducers mounted on a bakelite platform, the structural intensity vectors at locations distributed throughout the fuselage are measured. To minimize the errors associated with using a four transducers technique the measurement positions are selected away from bulkheads and stiffeners. Because four separate transducers are used, with each transducer having its own drive and conditioning amplifiers, phase errors are introduced in the measurements that can be much greater than the phase differences associated with the measurements. To minimize these phase errors two sets of measurements are taken for each position with the orientation of the transducers rotated by 180 deg and an average taken between the two sets of measurements. Results are presented and discussed.

Cuschieri, J. M.↗

FIRST THREE-DIMENSIONAL RECONSTRUCTIONS OF CORONAL LOOPS WITH THE STEREO A+B SPACECRAFT. IV. MAGNETIC MODELING WITH TWISTED FORCE-FREE FIELDS

The three-dimensional coordinates of stereoscopically triangulated loops provide strong constraints for magnetic field models of active regions in the solar corona. Here, we use STEREO/A and B data from some 500 stereoscopically triangulated loops observed in four active regions (2007 April 30, May 9, May 19, and December 11), together with SOHO/MDI line-of-sight magnetograms. We measure the average misalignment angle between the stereoscopic loops and theoretical magnetic field models, finding a mismatch of {mu} = 19 Degree-Sign -46 Degree-Sign for a potential field model, which is reduced to {mu} 14 Degree-Sign -19 Degree-Sign for a non-potential field model parameterized by twist parameters. The residual error is commensurable with stereoscopic measurement errors ({mu}{sub SE} Almost-Equal-To 8 Degree-Sign -12 Degree-Sign ). We developed a potential field code that deconvolves a line-of-sight magnetogram into three magnetic field components (B{sub x} , B{sub y} , B{sub z} ), as well as a non-potential field forward-fitting code that determines the full length of twisted loops (L Almost-Equal-To 50-300 Mm), the number of twist turns (median N{sub twist} = 0.06), the nonlinear force-free {alpha}-parameter (median {alpha} Almost-Equal-To 4 Multiplication-Sign 10{sup -11} cm{sup -1}), and the current density (median j{sub z} Almost-Equal-To 1500 Mx cm{sup -2} s{sup -1}). All twisted loops are found to be far below the critical value for kink instability, and Joule dissipation of their currents is found to be far below the coronal heating requirement. The algorithm developed here, based on an analytical solution of nonlinear force-free fields that is accurate to second order (in the force-free parameter {alpha}), represents the first code that enables fast forward fitting to photospheric magnetograms and stereoscopically triangulated loops in the solar corona.

79 ASTRONOMY AND ASTROPHYSICS↗

Analyzing Error in Balloon-Based Wind Measurements Due to Spatial Separation Using the North American Regional Reanalysis

Weather balloons have been a longstanding asset to NASA and Aerospace meteorology. Balloons are used from launch vehicle design to day-of-launch operations. One of the most valuable assets from these balloons is wind data from the surface up to 30 kilometers. Due to aloft winds, the balloons may drift downrange of the launch site and vehicle flight path. A 2017 study found balloons at Kennedy Space Center (KSC) can drift as far as 200 kilometers from the launch site (Decker 2017). To obtain robust launch vehicle wind assessments, it is highly desirable to characterize the wind environment along the flight path. This study looks into the errors associated with spatial separation of wind measurements using the North American Regional Reanalysis (NARR).

Curtis, Nathan↗

SU-E-J-263: Repeatability of SUV and Texture Parameters in Serial PET Studies

Purpose: Standardized uptake values (SUV) are standard quantitative PET measures of FDG tumor uptake used,and are used as a tool to monitor response to therapy. Textural analysis is emerging as a new tool for assessing intratumoral heterogeneity which may allow better tissue characterization and improved prediction of response and survival rate.Understanding what variations may be expected in these parameters is key in order to make decisions based on how the change throughout the course of treatment. The aim of this study was to assess repeatability in SUV measures and texture parameters,and establish criteria that differentiate changes associated with treatment rather than statistical variability. Methods: Eighty patients,167 random lesions total,were scanned in a GE Discovery STE PET/CT Scanner. One field-of-view was chosen centered on the largest lesion observed in a clinical whole-body FDG PET.Immediately following,a gated 9 min scan was acquired in list mode,without changing the patient’s position between any scans. Data was replayed into 3 time bins,3 min each,in order to insure equivalent noise characteristics in each replicate.Data was reconstructed into 128×128×47 square matrices.One VOI was drawn over each lesion for each patient and used to segment all 3 replicates. The mean.max and peak SUV were calculated for each VOI and replicate. First-order textural features were also calculated (skewness and kurtosis). Repeatability was calculated as the average standard deviation over the mean for the 3 repeated measurements for each lesion. Results: The average percent error in the SUV max,peak and mean were 3.4%(0– 12.9%),1.9% (0–7.5%),2.8% (0–12.2%),respectively.For skewness and kurtosis they were 10.9% and 17.8%. Conclusion: We have shown that there is a large variation in %error in SUV measures across patients. SUVpeak is the least variable and kurtosis and skewness parameters are less reliable thatn SUVs.Higher order textures are be.

60 APPLIED LIFE SCIENCES↗

A non-intrusive optical (NIO) approach to characterize heliostats in utility-scale power tower plants: Methodology and in-situ validation

No reliable in-situ optical characterization tool is available that can efficiently and accurately measure various optical errors of individual heliostats in a utility-scale power-tower plant. Here, an innovative non-intrusive optical (NIO) approach is proposed to measure mirror surface slope error, mirror facet canting error, and heliostat tracking error based on reflection images using the natural target—the tower—in a heliostat field. The NIO approach adopts various techniques in photogrammetry, reflectometry, and geometrical optics to first determine the camera position and the actual tower position with respect to the heliostat. Then, Snell’s law is applied to find the surface normal at the reflection point or line of a reflection image and derive the surface slope error, mirror facet canting error, and heliostat tracking error accordingly. In addition, an in-situ validation is performed to demonstrate the feasibility of the NIO approach. Analysis with multiple sets of reflection images on one single heliostat of interest demonstrates that the NIO method can achieve a measurement uncertainty of 0.22 mrad for mirror facet slope error (root-mean-square) at the given test conditions. The sensitivity of measurement uncertainty to various parameters will be presented in a separate work. In the future, state-of-the-art unmanned aerial systems (UAS) are planned to perform the efficient image collection with a goal to complete the survey across a utility-scale field of over 10,000 heliostats within one or a few days depending on the number of UASs. The development of the NIO approach is expected to fill the critical gap for successful solar-field operation and maintenance, which is necessary for the global growth of the solar power-tower technology. The NIO approach can also be applied to any relevant industry requiring high-precision mirror surface shape characterization.

14 SOLAR ENERGY↗

DETECTION OF LENSING SUBSTRUCTURE USING ALMA OBSERVATIONS OF THE DUSTY GALAXY SDP.81

We study the abundance of substructure in the matter density near galaxies using ALMA Science Verification observations of the strong lensing system SDP.81. We present a method to measure the abundance of subhalos around galaxies using interferometric observations of gravitational lenses. Using simulated ALMA observations we explore the effects of various systematics, including antenna phase errors and source priors, and show how such errors may be measured or marginalized. We apply our formalism to ALMA observations of SDP.81. We find evidence for the presence of a M = 10{sup 8.96±0.12} M {sub ⊙} subhalo near one of the images, with a significance of 6.9 σ in a joint fit to data from bands 6 and 7; the effect of the subhalo is also detected in both bands individually. We also derive constraints on the abundance of dark matter (DM) subhalos down to M ∼ 2 × 10{sup 7} M {sub ⊙}, pushing down to the mass regime of the smallest detected satellites in the Local Group, where there are significant discrepancies between the observed population of luminous galaxies and predicted DM subhalos. We find hints of additional substructure, warranting further study using the full SDP.81 data set (including, for example, the spectroscopic imaging of the lensed carbon monoxide emission). We compare the results of this search to the predictions of ΛCDM halos, and find that given current uncertainties in the host halo properties of SDP.81, our measurements of substructure are consistent with theoretical expectations. Observations of larger samples of gravitational lenses with ALMA should be able to improve the constraints on the abundance of galactic substructure.

79 ASTRONOMY AND ASTROPHYSICS↗

Data-driven acoustic measurement of moisture content in flowing biomass

Measuring the moisture content in flowing biomass is critical to processes such as liquid biofuel conversion, such as biogasoline, biodiesel, bio jet kerosene, etc. However, biomass tends to flow in aggregates, which results in significant inhomogeneities in the amount of biomass flowing in front of a sensor at a given time, and there can be significant overlap in the material properties of dry vs wet biomass, leading to poor signal-to-noise ratio. We present a technique for identifying biomass moisture content using a series of acoustic pitch-catch measurements to quantify the sound speed and acoustic amplitude through the biomass, in conjunction with classical machine learning techniques, including Naive Bayes, Random Forest, and K-Nearest Neighbors classification. We amplify the differences between the acoustic measurements in different moisture levels by collecting a series of pulse-echo measurements, which we sort in order of ascending sound speed. We test the accuracy of the technique on experimentally-prepared batches of corn stover biomass with specified moisture levels and measure the average error in the estimated moisture level as a function of the number of pitch-catch measurements used. We observe average estimation errors as low as 6.7% by increasing the number of measurements and optimizing the hyperparameters. This work presents a novel method determining moisture content in flowing biomass with inhomogeneous flow. Additionally, this technique has application in optimizing biomass conversion processes, as well as other fields including, paper production, natural fiber processing, and mineral extraction.

09 BIOMASS FUELS↗

Investigations into the origins of polyatomic ions in inductively coupled plasma-mass spectrometry

An inductively coupled plasma-mass spectrometer (ICP-MS) is an elemental analytical instrument capable of determining nearly all elements in the periodic table at limits of detection in the parts per quadrillion and with a linear analytical range over 8-10 orders of magnitude. Three concentric quartz tubes make up the plasma torch. Argon gas is spiraled through the outer tube and generates the plasma powered by a looped load coil operating at 27.1 or 40.6 MHz. The argon flow of the middle channel is used to keep the plasma above the innermost tube through which solid or aqueous sample is carried in a third argon stream. A sample is progressively desolvated, atomized and ionized. The torch is operated at atmospheric pressure. To reach the reduced pressures of mass spectrometers, ions are extracted through a series of two, approximately one millimeter wide, circular apertures set in water cooled metal cones. The space between the cones is evacuated to approximately one torr. The space behind the second cone is pumped down to, or near to, the pressure needed for the mass spectrometer (MS). The first cone, called the sampler, is placed directly in the plasma plume and its position is adjusted to the point where atomic ions are most abundant. The hot plasma gas expands through the sampler orifice and in this expansion is placed the second cone, called the skimmer. After the skimmer traditional MS designs are employed, i.e. quadrupoles, magnetic sectors, time-of-flight. ICP-MS is the leading trace element analysis technique. One of its weaknesses are polyatomic ions. This dissertation has added to the fundamental understanding of some of these polyatomic ions, their origins and behavior. Although mainly continuing the work of others, certain novel approaches have been introduced here. Chapter 2 includes the first reported efforts to include high temperature corrections to the partition functions of the polyatomic ions in ICP-MS. This and other objections to preceeding papers in this area were addressed. Errors in the measured T gas values were found for given errors in the experimental and spectroscopic values. The ionization energy of the neutral polyatomic ion was included in calculations to prove the validity of ignoring more complicated equilibria. Work was begun on the question of agreement between kinetics of the plasma and interface and the increase and depletion seen in certain polyatomic ions. This dissertation was also the first to report day to day ranges for T gas values and to use a statistical test to compare different operating conditions. This will help guide comparisons of previous and future work. Chapter 4 was the first attempt to include the excited electronic state 2 in the partition function of ArO + as well as the first to address the different dissociation products of the ground and first electronic levels of ArO + . Chapter 5 reports an interesting source of memory in ICP-MS that could affect mathematical corrections for polyatomic ions. For future work on these topics I suggest the following experiments and investigations. Clearly not an extensive list, they are instead the first topics curiosity brings to mind. (1) Measurement of T gas values when using the flow injection technique of Appendix B. It was believed that there was a fundamental difference in the plasma when the auto-sampler was used versus a continuous injection. Is this reflected in T gas values? (2) The work of Chapter 3 can be expanded and supplemented with more trials, new cone materials (i.e. copper, stainless steel) and more cone geometries. Some of this equipment is already present in the laboratory, others could be purchased or made. (3) T gas values from Chapter 3 could be correlated with instrument pressures during the experiment. Pressures after the skimmer cone were recorded for many days but have yet to be collated with the measured T gas values. (4) The work in Chapter 5 could be expanded to include more metals. Does the curious correlation between measured T gas and element boiling point persist? (5) Investigate non-linear correlations to T gas values of the MO + memory in Chapter 5. Temperatures along the skimmer walls are not a linear gradient. Ring deposits have been observed on the cone and photographs of the interface show light intensities shaping a sort of tailing peak along the outside skimmer wall. Is there a physical property of the metals or metal oxides that would give this peak with the T gas values? (6) Chemical state speciation of the metal deposits on the skimmers of Chapter 5. There may be a more logical correlation between Tgas and a physical property of the deposit-ing chemical if all the metals do not deposit in the same form. (7) A collaboration with our computational collegues would be most welcome. Newer calculations for ArO + and RuO + would be very helpful.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE ERROR BUDGET OF THE DARK FLOW MEASUREMENT

We analyze the uncertainties and possible systematics associated with the 'Dark Flow' measurements using the cumulative Sunyaev-Zeldovich (SZ) effect combined with all-sky catalogs of clusters of galaxies. Filtering of all-sky cosmic microwave background maps is required to remove the intrinsic cosmological signal down to the limit imposed by cosmic variance. Contributions to the errors come from the remaining cosmological signal, which integrates down with the number of clusters, and the instrumental noise, which scales with the number of pixels; the latter decreases with integration time and is subdominant for the Wilkinson Microwave Anisotropy Probe (WMAP) 5 year data. It is proven both analytically and numerically that the errors for the 5 year WMAP data are {approx_equal}15{radical}(3/N{sub clusters}) {mu}K per dipole component. The relevant components of the bulk flow velocity are measured with a high statistical significance of up to {approx}>3-3.5{sigma} for the brighter cluster samples. We discuss different methods to compute error bars and demonstrate that they have biases that would overpredict the errors, as is the case in a recent reanalysis of our earlier results. If the signal is caused by systematic effects present in the data, such systematics must have a dipole pattern, correlate with cluster X-ray luminosity, and be present only at cluster positions. Only contributions from the SZ effect could provide such contaminants via several potential effects. We discuss such candidates apart from the bulk motion of the cluster samples and demonstrate that their contributions to our measurements are negligible. Application of our methods and database to the upcoming PLANCK maps, with their large frequency coverage, and, in particular, the 217 GHz channel will eliminate any such contributions and determine better the amplitude, coherence, and scale of the flow.

79 ASTRONOMY AND ASTROPHYSICS↗

Refine your search to explore more results.