Accurate positioning of characters on CRT displays

Two systems, one digital and one analog, improve positioning of characters in cathode-ray tube (CRT) display systems. Circuits minimize effects of amplifier settling times--effects that can displace and distort characters in high-speed multiplexed systems.

Damian, J. R.↗

Hybrid random-sound test-control system

Controller develops gain-control signals by comparing detected sound levels in each band with reference set levels. By eliminating multiplexing network and single clock used in digital system, design allows servocontrol rate for each band to be adjusted independently.

Woodbury, R. C.↗

Data reformatting with less hardware

Dual-function integrated circuits use one shift register array instead of two to feed video data to seven tape channels thereby making system more reliable and less expensive than predecessor. Basic principle of reformatter is also applicable to multiplexing and frequency conversion circuits.

Engel, A.↗

High-sampling-rate pressure transducer has in situ calibration

High-data-rate pressure sensor module can be calibrated after it is attached to an experimental setup. Electrically multiplexed sensor is designed for use in wind-tunnels and other applications requiring accurate measurement of many pressures in a short period of time.

Gross, C.↗

A review of NASA fiber optics tasks

The status of on-going NASA tasks involving fiber optic data transmission, and related topics is given. Ground based applications, including a multiplexed wideband 2 km prototype link and a building-to-building video link, are described. In connection with the use of fibers in space, the effects to be expected from the space environment are touched on, particularly radiation darkening of fibers and temperature effects. Laboratory results on performance of fibers at cryogenic temperatures are also presented. Finally, some thoughts on future applications are given.

Johnston, A. R.↗

A modular minicomputer based Navier-Stokes solver

The basic module consists of a minicomputer, low cost peripheral storage device (disk) and a modest number (8-12) of microcomputer modules. A simple arrangement, where the microcomputers are connected to a single time multiplexed bus, only communicating to the host minicomputer, will be efficient. By running the machine in a dedicated mode for long periods of time, it will be possible to obtain a large number of solutions. As such, the device should be useful as a research tool. A scheme is outlined to assemble a number of these computing modules in parallel to decrease computing time. The advantages and disadvantages are discussed of using a number of these systems assembled in a loosely coupled configuration, each independently computing a separate flow, to give a very high throughput.

Steinhoff, J.↗

A rotor-mounted digital instrumentation system for helicopter blade flight research measurements

A rotor mounted flight instrumentation system developed for helicopter rotor blade research is described. The system utilizes high speed digital techniques to acquire research data from miniature pressure transducers on advanced rotor airfoils which are flight tested on an AH-1G helicopter. The system employs microelectronic pulse code modulation (PCM) multiplexer digitizer stations located remotely on the blade and in a hub mounted metal canister. As many as 25 sensors can be remotely digitized by a 2.5 mm thick electronics package mounted on the blade near the tip to reduce blade wiring. The electronics contained in the canister digitizes up to 16 sensors, formats these data with serial PCM data from the remote stations, and transmits the data from the canister which is above the plane of the rotor. Data are transmitted over an RF link to the ground for real time monitoring and to the helicopter fuselage for tape recording. The complete system is powered by batteries located in the canister and requires no slip rings on the rotor shaft.

Knight, V. H., Jr.↗

Spacelab uplink/downlink data flow and formats

The results of an analysis of the Spacelab (SL) data uplink/downlink structure and those data system elements associated with the support of this data flow are presented. Specific objectives of this report are to present the results of the following analyses: (1) operations of the SL high rate multiplexer, including format structure, data rates, format combinations, format switching, etc.; (2) operations of SL data recorders to include the definition of modes, data rates and forms; (3) operations of the high rate demultiplexer as described above; (4) potential experiment data formats defining formatting parameters to be considered in decommutation analysis; (5) SL computer input/output (I/O) decommutation channels, including the definition of structure, quantity and use of this I/O data; (6) detailed requirements of the data quality monitoring philosophy for this function.

Kandefer, F.↗

Escort: A data acquisition and display system to support research testing

Primarily designed to acquire data at steady state test conditions, the system can also monitor slow transients such as those generated in moving to a new test condition. The system configuration makes use of a microcomputer at the test site which acts as a communications multiplexer between the measurement and display devices and a centrally located minicomputer. A variety of measurement and display devices are supported using a modular approach. This allows each system to be configured with the proper combination of devices to meet the specific test requirements, while still leaving the option to add special interfaces when needed. Centralization of the minicomputer improves utilization through sharing. The creation of a pool of minis to provide data acquisition and display services to a variable number of running tests also offers other important advantages.

Miller, R. L.↗

A miniature 48-channel pressure sensor module capable of in situ calibration

A new high data rate pressure sensor module with in situ calibration capability has been developed by the Langley Research Center to help reduce energy consumption in wind-tunnel facilities without loss of measurement accuracy. The sensor module allows for nearly a two order of magnitude increase in data rates over conventional electromechanically scanned pressure sampling techniques. This module consists of 16 solid state pressure sensor chips and signal multiplexing electronics integrally mounted to a four position pressure selector switch. One of the four positions of the pressure selector switch allows the in situ calibration of the 16 pressure sensors; the three other positions allow 48 channels (three sets of 16) pressure inputs to be measured by sensors. The small size of the sensor module will allow mounting within many wind-tunnel models, thus eliminating long tube lengths and their corresponding slow pressure response.

Gross, C.↗

A packet telemetry system employing ARQ error control

A proposed packet telemetry system employing automatic retransmission request (ARQ) mode of error control is characterized. Limitations of the present multiplexing/demultiplexing approach are considered, and the use of the proposed system in near-earth satellites in the 1980s is suggested. Onboard processing and an adaptive multiplexing technique are described, as is an elastic buffer, required because the instantaneous data rate will be different from the telemetry transmission rate. The telemetry packets would be encoded into a powerful error-detection block code. A mechanism involving temporary buffering in a long shift register will permit retransmission request from the ground station for packets received in error. The ARQ mode of operation should ensure essentially error-free transmission at lower signal-to-noise ratios and at considerably higher transmission rates than are usually used.

Greene, E. P.↗

Communication satellite services for special purpose users

The present study identifies potential satellite services, examines the technology necessary for efficient implementation of these services, and determines minimum service cost versus user network size. The generic satellite services evaluated comprise TV and radio distribution (for retransmission), video teleconferencing (interactive), audio/facsimile teleconferencing (interactive), multiplexed data/voice (point-to-point), and satellite-supported land mobile. Satellite costs are based on extrapolations from ongoing commercial satellite programs. Production methods, new technology, and effect of production quantities on present and future production costs are examined to provide information on earth station equipment cost versus the variable 'buy'. Six different launch vehicles from a Delta 2914 to a dedicated Shuttle and three frequency bands and both broadcast (no eclipse capability) and fixed service satellites are considered to assess the effect of satellite size on cost and performance. It is assumed that the user pays only for his prorata share of the space segment costs.

Wright, D. L.↗

Simpler cabling and power link for remote readouts

Display power and segment data are multiplexed over same coaxial line. Thus, only one wire and return lead are needed, and single power supply at central location can service all remote displays.

Perry, J. C.↗

Development of CMOS integrated circuits

Report documents life cycles of two custom CMOS integrated circuits: (1) 4-bit multiplexed register with shift left and shift right capabilities, and (2) dual 4-bit registers. Cycles described include conception as logic diagrams through design, fabrication, testing, and delivery.

Bertino, F.↗

Apparatus and method for stabilized phase detection for binary signal tracking loops

Apparatus and method is presented for phase detection in binary signal tracking loops wherein two bandpass detectors are alternately interchanged between electrical connection with two local code reference tracking signals in order to cancel any adverse effect of gain imbalance in the bandpass detectors and direct current offset or drift. The detectors are time shared in multiplex fashion between the two local reference signals.

Hopkins, P. M.↗

Development of single-cell protectors for sealed silver-zinc cells

Three design approaches to cell-level protection were developed, fabricated, and tested. These systems are referred to as the single-cell protector (SCP), multiplexed-cell protector(MCP). To evaluate the systems 18-cell battery packs without cell level control were subjected to cycle life test. A total of five batteries were subjected to simulate synchronous orbit cycling at 40% depth of discharge at 22C. Batteries without cell-level protection failed between 345 and 255 cycles. Cell failure in the cell level protected batteries occurred between 412 and 540. It was determined that the cell-level monitoring and protection is necessary to attain the long cycle life of a AgZn battery. The best method of providing control and protection of the AgZn cells depends on the specific application and capability of the user.

Lear, J. W.↗

NOVA/IOPS - MDM/SIO - SL/BIU data transfer test software guide

The NOVA/IOPS (Input-Output Processor Simulator) is used to control all interface testing of the MDM (Multiplexer Demultiplexer) Breadboard S10 10M (serial input-output-input module) and the Matra Space Lab Inerface Unit (SL/BIU). The software handles bookkeeping such as word error rates, types of errors, display of error buffers, data display and test identification.

Source record↗

Electronically scanned pressure sensor module with in SITU calibration capability

This high data rate pressure sensor module helps reduce energy consumption in wind tunnel facilities without loss of measurement accuracy. The sensor module allows for nearly a two order of magnitude increase in data rates over conventional electromechanically scanned pressure sampling techniques. The module consists of 16 solid state pressure sensor chips and signal multiplexing electronics integrally mounted to a four position pressure selector switch. One of the four positions of the pressure selector switch allows the in situ calibration of the 16 pressure sensors; the three other positions allow 48 channels (three sets of 16) pressure inputs to be measured by the sensors. The small size of the sensor module will allow mounting within many wind tunnel models, thus eliminating long tube lengths and their corresponding slow pressure response.

Gross, C.↗

Refine your search to explore more results.