Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Tests of factorization and SU(3) relations in B decays into heavy-light final states

Using data from the B factories and the Tevatron, we perform tests of how well nonleptonic B decays of the kind B{yields}D{sub (s)}{sup (*)}P, where P is a pion or kaon, are described within the factorization framework. We find that factorization works well--as is theoretically expected--for color-allowed, tree-diagram-like topologies. Moreover, also exchange topologies, which have a nonfactorizable character, do not show any anomalous behavior. We discuss also isospin triangles between the B{yields}D{sup (*)}{pi} decay amplitudes, and determine the corresponding amplitudes in the complex plane, which show a significant enhancement of the color-suppressed tree contribution with respect to the factorization picture. Using data for B{yields}D{sup (*)}K decays, we determine SU(3)-breaking effects and cannot resolve any nonfactorizable SU(3)-breaking corrections larger than {approx}5%. In view of these results, we point out that a comparison between the B{sub d}{sup 0}{yields}D{sup +}{pi}{sup -} and B{sub s}{sup 0}{yields}D{sub s}{sup +}{pi}{sup -} decays offers an interesting new determination of f{sub d}/f{sub s}. Using CDF data, we obtain the most precise value of this ratio at CDF, and discuss the prospects for a corresponding measurement at LHCb.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of Data Fusion Applied to Health Monitoring of Wind Turbine Drive train Components

The research described was performed on diagnostic tools used to detect damage to dynamic mechanical components in a wind turbine gearbox. Different monitoring technologies were evaluated by collecting vibration and oil debris data from tests performed on a "healthy" gearbox and a damaged gearbox in a dynamometer test stand located at the National Renewable Energy Laboratory. The damaged gearbox tested was removed from the field after experiencing component damage due to two losses of oil events and was retested under controlled conditions in the dynamometer test stand. Preliminary results indicate oil debris and vibration can be integrated to assess the health of the wind turbine gearbox.

Dempsey, Paula J.↗

SEASAT A satellite scatterometer

The analyses performed in the early period of the program which formed the basis of the sensor design is reviewed, along with the sensor design. The test program is outlined, listing all tests performed and the environmental exposure (simulated) for each, as applicable. Ground support equipment designed and built for assembly integration and field testing is described. The software developed during the program and the algorithms/flow diagrams which formed the bases for the software are summarized.

Bianchi, R.↗

Development and Testing of an Integrated Sandia Cooler Thermoelectric Device (SCTD).

This report describes a FY14 effort to develop an integrated Sandia Cooler T hermoelectric D evice (SCTD) . The project included a review of feasible thermoelectric (TE) cooling applications, baseline performance testing of an existing TE device, analysis and design development of an integrated SCTD assembly, and performance measurement and validation of the integrated SCTD prototype.

Johnson, Terry A.↗

A portable Ka-band front-end test package for beam-waveguide antenna performance evaluation. Part 2: Tests on the antenna

In part one of this article, a description was given of a Ka-band test package developed to enable testing of the Deep Space Station (DDS) 13 34-m beam-waveguide (BWG) antenna at 32 GHz. Test results were given for the Ka-band test package in an on-the-ground test configuration. This article is a companion article concerned with Ka-band test results for the test package in an on-the-antenna test configuration. Included are Ka-band zenith noise-temperature values, tipping-curve data, and subreflector test results obtained at the Cassegrain focal point, as well as at the final BWG focal point (located in a subterranean pedestal room). Test results show that, through the use of the Ka-band test package, the BWG antenna performance was successfully evaluated at Ka-band. The Ka-band test package operated well in all of the different antenna test configurations.

Otoshi, T. Y.↗

Dip leg plug formation evaluation and abatement testing in support of the H-Canyon accelerated basin de-inventory

As requested in the Technical Task Request (TTR), the Savannah River National Laboratory (SRNL) performed testing on the current typical bubbler dip leg design used in the H-Area Canyon (HCA). The TTR has a functional classification of General Services. Testing was initiated to ascertain if the plugging described in the TTR could be reproduced and, if so, to obtain general metrics on the resulting plugging dynamics, and evaluate possible mitigating methods, including design changes and cleaning/purging protocols. The bubblers were to be suspended in a simulant typical of H-Canyon solutions containing aluminum nitrate and silica at a temperature of 25°C using a nominal bubbler air flowrate of 7.5 SCFH. Emphasis was placed on minimizing equipment changes necessary to accomplish the mitigations, as equipment changes in the existing facility would be costly. Testing evolved into four (4) phases, concluding that plugging could indeed be reproduced (believed to be attributed to localized evaporation and bridging of crystals in the dip legs). During testing, plug formation information was obtained, including time, pressure, and temperature traces leading to plugging were defined; solution compositions leading to plugging were determined, and various physical characteristics (visual and mechanical) of the crystallized plug were obtained.

42 ENGINEERING↗

Performance of five 30 GHz satellite receivers

Technology development contracts funded by NASA have resulted in five 30 GHz satellite receivers of various design. The results of tests performed at NASA-Lewis to determine the operating characteristics of the receivers and their ability to perform in a digital satellite link are presented and discussed.

Kerczewski, Robert J.↗

Testing and Calibration of the NASA COR1 Coronagraph for the Solar Terrestrial Relations Observatory (STEREO)

This proposal is for a no cost extension on the period of performance of the existing grant. The period of performance shall be extended to the end of FY 2003. This extension is required due to schedule changes in the COR1 program. Funding for Phase II and Phase III of this grant has been obtained. This unsolicited proposal was for scientific and engineering collaboration between NASA s Goddard Space Flight Center (GSFC) and HAO. Performance testing of the COR1 engineering test unit has been partially completed. The COR1 coronagraph engineering test unit requires further testing at NASA s GSFC and the National Center for Atmospheric Research (NCAR) Mauna Loa Solar Observatory (MLSO), operated by the High Altitude Observatory (HAO). HAO personnel have recently supported efforts to test component and breadboard versions of the COR1 using the NCAR Vacuum Tunnel Facility (NVTF). HAO personnel will continue to work closely with scientists and engineers at NASA/GSFC in the development, design, assembly, testing, and operation of this key element of NASA's Solar Terrestrial Relations Observatory (STEREO) mission. The element is an internally-occulted coronagraphic telescope, and the design and development effort is already underway at GSFC.

Burkepile, J. T.↗

A Comparative Evaluation of Additive Manufactured Stainless Steel Test Pieces

Stainless steel is used for variety of applications with different grades, alloys, filaments and powders. Additive manufacturing (AM) enables unique design features and refined microstructures. Performance testing on AM parts are needed as input to modeling and accelerated qualification processes. The objective of this work is to determine the effect of surface roughness on corrosion rate for from different manufacturers Preliminary evaluation shows that the 500-hour data set was scattered, and trend analysis are complex, while the 1000h and 1500h test results evaluation show more distinct trends.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a plasma driven permeation experiment for TPE

Experiments on retention of hydrogen isotopes (including tritium) at temperatures less than 800 ?C have been carried out in the Tritium Plasma Experiment (TPE) at Idaho National Laboratory [1,2]. To provide a direct measurement of plasma driven permeation in plasma facing materials at temperatures reaching 1000 ?C, a new TPE membrane holder has been built to hold test specimens (=1 mm in thickness) at high temperature while measuring tritium permeating through the membrane from the plasma facing side. This measurement is accomplished by employing a carrier gas that transports the permeating tritium from the backside of the membrane to ion chambers giving a direct measurement of the plasma driven tritium permeation rate. Isolation of the membrane cooling and sweep gases from TPE’s vacuum chamber has been demonstrated by sealing tests performed up to 1000 ?C of a membrane holder design that provides easy change out of membrane specimens between tests. Simulations of the helium carrier gas which transports tritium to the ion chamber indicate a very small pressure drop (~700 Pa) with good flow uniformity (at 1000 sccm). Thermal transport simulations indicate that temperatures up to 1000 ?C are expected at the highest TPE fluxes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of catalyst-coated membranes for enhancing performance in proton exchange membrane electrolyzer cells

To achieve large-scale application of proton exchange membrane electrolyzer cells (PEMECs) for hydrogen production, it is highly desirable to reduce the manufacturing cost while enhancing cell performance. In the PEMPECs, a catalyst-coated membrane (CCM) is the vital component where electrochemical reactions and mass transport mainly occur. The fabrication methods and catalyst layer (CL) structure can significantly affect the cell performance. Herein, for the first time, a comparative study of CCM fabrications with decal transfer and direct spray deposition methods have been conducted by both ex-situ materials characterization and in-situ performance testing in PEMECs. It is found CCMs that are fabricated with a direct spray deposition method display enhanced cell performance compared to CCMs fabricated with a decal transfer method, mainly due to the largely reduced ohmic resistance and improved mass transport. More importantly, cell performance can be greatly enhanced by simply regulating the Nafion ionomer content at the anode CL. The optimal Nafion ionomer content of 10 wt% gives the best cell performance at 80 °C with a low cell voltage of 1.887 V at 2 A cm -2 , outperforming the commercial CCM and most other previous publications. Our study provides a valuable guidance for fabrication and optimization of CCMs with significantly enhanced performance and reduced cost for practical application of the PEMECs.

08 HYDROGEN↗

Influence of topology optimization parameters on the mechanical response of an additively manufactured test structure

Topology Optimization (TO) determines a material distribution within a domain under given conditions and design constraints, and generally generates complex geometries as a result. Complementary to TO, Additive Manufacturing (AM) offers the ability to fabricate complex geometries which may be difficult to manufacture using traditional techniques such as milling. AM has been used in multiple industries including the medical devices area. Hence, TO may be used to create patient-matched devices where the mechanical response is catered to a particular patient. Furthermore, during a medical device regulatory 510(k) pathway, demonstrating that worst-cases are known and tested is critical to the review process. Using TO and AM to predict worst-case designs for subsequent performance testing may be challenging and does not appear to have been thoroughly explored. Investigating the effects of TO input parameters when AM is employed may be the first step in determining the feasibility of predicting these worst-cases.

36 MATERIALS SCIENCE↗

Impact of Microporous Layer Roughness on Gas-Diffusion-Electrode-Based Polymer Electrolyte Membrane Fuel Cell Performance

This study explores the role of the gas diffusion media microporous layer (MPL) surface structure on the electrochemical properties of gas-diffusion-electrode (GDE)-based membrane electrode assemblies (MEAs). It has been shown that a thin ionomer layer on top of the GDE and hot pressing is needed to create good contact between the catalyst layer and the membrane. In this study, gas diffusion media with different MPL surface roughness were applied to fabricate GDE-based MEAs to understand how MPL roughness impacts the amount of ionomer overlayer required for maximum performance. Electron microscopy was employed to investigate MPL/catalyst layer and catalyst layer/membrane interfaces. In-situ performance testing was used to assess the impact of MPL roughness and ionomer overlayer on catalyst utilization and air polarization performance. We find that a smoother MPL surface required a thinner ionomer overlayer than gas diffusion media (GDM) with a rougher MPL surface to achieve a performance comparable to direct-coated catalyst-coated-membrane MEAs.

36 MATERIALS SCIENCE↗

Development of soft X-ray polarized light beamline on Indus-2 synchrotron radiation source

This article describes the development of a soft x-ray beamline on a bending magnet source of Indus-2 storage ring (2.5 GeV) and some preliminary results of x-ray absorption spectroscopy (XAS) measurements using the same. The beamline layout is based on a spherical grating monochromator. The beamline is able to accept synchrotron radiation from the bending magnet port BL-1 of the Indus-2 ring with a wide solid angle. The large horizontal and vertical angular acceptance contributes to high photon flux and selective polarization respectively. The complete beamline is tested for ultrahigh vacuum (UHV) ∼ 10{sup −10} mbar. First absorption spectrum was obtained on HOPG graphite foil. Our performance test indicates that modest resolving power has been achieved with adequate photon flux to carry out various absorption experiments.

43 PARTICLE ACCELERATORS↗

Sierra/SolidMechanics 5.0 Example Problems Manual

Presented in this document are tests that exist in the Sierra/SolidMechanics example problem suite, which is a subset of the Sierra / SM regression and performance test suite. These examples showcase common and advanced code capabilities. A wide variety of other regression and verification tests exist in the Sierra / SM test suite that are not included in this manual.

97 MATHEMATICS AND COMPUTING↗

Refine your search to explore more results.