Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Comparison of heavy metals, parasites and histopathology in sculpins (Myoxocephalus spp.) from two sites at a lead-zinc mine in North East Greenland

Highlights: • Mestersvig mine Pb-Zn mine in East Greenland has led to significant metal pollution. • Gill and liver morphology of fourhorn and shorthorn sculpins was evaluated as bio-indicators. • Significant pathologies were found and were related to metal concentrations. • Sculpin pathology may be suitable health indicators mining activity effects. • These should be enrolled in EIAs of raw material industrialisation in the Arctic. The former lead-zinc mine at Mestersvig, Greenland, continues to contaminate the surrounding environment despite its operations ceasing over 50 years ago. Elevated concentrations of heavy metals are found in water, sediment and biota in the terrestrial, freshwater and marine environments. To shed light on the present contamination and its potential effects on local fish we investigated gill and liver histology of sculpins (Myoxocephalus spp.) around the former mining area. Two species of sculpins were caught; shorthorn sculpins (M. scorpius; n = 16) and fourhorn sculpins (M. quadricornis; n = 17) at a contaminated site, Nyhavn, and shorthorn sculpins (M. scorpius; n = 25) at the reference site. In a previous study we found histopathological changes in the tissues of the sculpins, and we suspected this to be related to elevated heavy metal tissue concentrations. Concentrations of Fe, Hg, Mn, Pb, Se and Zn were significantly higher in sculpins at Nyhavn compared to the reference site. Reference NOED and LOEC thresholds for biochemistry, tissue lesions, growth, survival and reproduction for hepatic Hg, As, Cd and Pb from the ERED database were exceeded in both sculpin species. Histopathological investigations of the sculpins gills revealed significant increases in the prevalence of hyperplastic epithelium, inflammation, intensity of neutral and total mucus cells and chloride cells along with an increased infection of colonial Peritricha. At the contaminated Nyhavn site, fourhorn sculpins had a significantly higher prevalence of chondroplastic tissue and intensity of neutral, mixed and total mucus cells in the gills compared to the shorthorn sculpins. The data indicate that both sculpin species could be useful indicator species for environmental monitoring of metal pollution in Arctic areas. However, confounding effects of gender and species should be investigated further. Effects on other biomarkers as well as baseline measurements should be included in future environmental monitoring efforts around mining activities in Greenland.

54 ENVIRONMENTAL SCIENCES↗

Economic dispatch for electricity merchant with energy storage and wind plant: State of charge based decision making considering market impact and uncertainties

Here this paper investigates how the market impact of electricity merchants and uncertainty of wind generation affect their co-optimized scheduling policy, specifically for merchants who have both energy storage and wind plants. In the existing literature, merchants' trading actions are usually assumed not to affect market prices; however, a large-scale energy storage merchant's actions can affect market prices. To this end, we approximate the electricity price by a linear function of the quantity of power traded by the merchant in the reward function to achieve decision-making incorporating the market impact. This paper utilizes the dynamic programming approach to analyze merchants' optimal multi-period decision-making incorporating market impact, uncertain wind generation, and energy storage constraints. First, our results demonstrate that for a merchant with co-located energy storage facilities and wind power plants, the energy storage's feasible state of charge (SOC) range can be segmented into four possible sub-ranges by three analytically developed SOC reference points. The unique optimal trading decision can be achieved by comparing the current energy inventory and the SOC references of the next period. Second, our results show that market impact and uncertainties substantially change the optimal storage scheduling policy by impacting the values of the reference points. To mitigate the negative effect of the merchant's market impact on buying and selling actions, the merchant may reduce the amount of generating or pumping electricity each period to maximize profit. Moreover, we identify and investigate the trade-off between market price and transaction quantity. Our findings provide co-optimized scheduling guidance for electricity merchants with co-located energy storage and renewable power plants systems.

17 WIND ENERGY↗

Assessment of human nuclear and mitochondrial DNA qPCR assays for quantification accuracy utilizing NIST SRM 2372a

In forensic DNA casework, a highly accurate real-time quantitative polymerase chain reaction (qPCR) assay is recommended per the Scientific Working Group on DNA Analysis Methods (SWGDAM) (SWGDAM Validation Guidelines for DNA Analysis Methods [1]) to determine whether a DNA sample is of sufficient quantity and robust quality to move forward with downstream short tandem repeats (STR) or sequencing analyses. Most of these assays rely on a standard curve, referred to herein and traditionally as absolute qPCR, in which an unknown is compared, relative to that curve. However, one fundamental issue with absolute qPCR is the quantifiable concentration of commercial assay standards can vary depending on (1) origin, i.e., whether from a cell line or a human subject, (2) supplier, (3) lot number, (4) shipping method, etc. In 2018, the National Institute for Standards and Technology (NIST) released a human DNA standard reference material for evaluating qPCR quantification standards, Standard Reference Material (SRM) 2372a, Romsos et al. (2018) [2] which contains three well-characterized human genomic DNA samples: Component A) a single male1 donor, Component B) a single female 1 donor, and Component C) a 1:3 male 2 :female 2 donor, each with certification data for nDNA and informational mitochondrial DNA(mtDNA)/nuclear DNA (nDNA) ratio data. The SRM 2372a was used to assess four qPCR assays: (1) Quantifiler Trio (Thermo Fisher Scientific, Waltham, MA) for nDNA quantification, (2) NovaQUANT (EMD Millipore Corporation, San Diego, CA) for nDNA and mtDNA quantification, (3) a custom duplex mtDNA assay, and (4) a custom triplex mtDNA assay. Additionally, extracts from eighteen (18) skeletal remains were tested with the latter three assays for concordance of DNA concentration and with assays (2) and (3), for the degradation state. Our assessment revealed that an accurate, efficient, and reproducible qPCR assay is dependent on (1) the quality and reliability of the DNA standard, (2) the qPCR chemistry, and (3) the specific primers, and probes (if applicable), used in an assay. Finally, our findings indicate qPCR assays may not always quantify as expected and that performance of each lot should be verified using a well-characterized DNA standard such as the NIST SRM 2372a and adjusted if warranted.

59 BASIC BIOLOGICAL SCIENCES↗

Data catalog project—A browsable, searchable, metadata system

Modern experiments are typically conducted by large, extended groups, where researchers rely on other team members to produce much of the data they use. The experiments record very large numbers of measurements that can be difficult for users to find, access and understand. Here. we are developing a system for users to annotate their data products with structured metadata, providing data consumers with a discoverable, browsable data index. Machine understandable metadata captures the underlying semantics of the recorded data, which can then be consumed by both programs, and interactively by users. Collaborators can use these metadata to select and understand recorded measurements. The data catalog project is a data dictionary and index which enables users to record general descriptive metadata, use cases and rendering information as well as providing them a transparent data access mechanism (URI). Users describe their diagnostic including references, text descriptions, units, labels, example data instances, author contact information and data access URIs. The list of possible attribute labels is extensible, but limiting the vocabulary of names increases the utility of the system. The data catalog is focused on the data products and complements process-based systems like the Metadata Ontology Provenance project [Greenwald, 2012; Schissel, 2015]. This system can be coupled with MDSplus to provide a simple platform for data driven display and analysis programs. Sites which use MDSplus can describe tree branches, and if desired create ‘processed data trees’ with homogeneous node structures for measurements. Sites not currently using MDSplus can either use the database to reference local data stores, or construct an MDSplus tree whose leaves reference the local data store. A data catalog system can provide a useful roadmap of data acquired from experiments or simulations making it easier for researchers to find and access important data and understand the meaning of the data and how it was obtained. This is particularly useful in research facilities that study the results of many different experiments or simulations and may not know the intricacies of the data organization in use where the data was generated. It is also possible to store a local copy of key data items in local MDSplus trees and then add processed data to the local catalog.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improving Soft-Tissue Contrast in Four-Dimensional Computed Tomography Images of Liver Cancer Patients Using a Deformable Image Registration Method

Purpose: To investigate a deformable image registration method to improve soft-tissue contrast in four-dimensional (4D) computed tomography (CT) images of the liver. Methods and Materials: Ten patients with hepatocellular carcinoma underwent 4D CT scan for radiotherapy treatment planning on a positron emission tomography/CT scanner. Four-dimensional CT images were binned into 10 equispaced phases. The exhale phase served as the reference phase, and images from the other nine phases were coregistered to the reference phase image using an intensity-based, automatic deformable image registration method. Then the coregistered images were combined to create a single, high-quality reconstructed CT image at exhale phase as the new reference for target delineation. The extent of image quality enhancement was quantified relative to the original CT by calculating the signal-to-noise ratio and the contrast-to-noise ratio. Results: The soft tissue image contrast was noticeably better after deformable image registration than in the original scans. Signal-to-noise ratios inside the liver region of interest increased for all patients by a factor of 3.0 (range, 2.3-3.7). The improvement in image quality was not linearly proportionate to the number of images averaged. Using only 6 phases can achieve at least 85% of the contrast enhancement that can be achieved using all 10 phases. We also found that contrast enhancement was inversely proportional to the original image quality (p = 0.006), and the contrast enhancement is attained with little loss of spatial resolution. Conclusions: This deformable image registration method is feasible to improve soft-tissue image quality in 4D CT images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intestinal Malabsorption in Long-Term Survivors of Cervical Cancer Treated With Radiotherapy

Purpose: The aim of this cross-sectional study is to investigate the associations between pelvic radiotherapy (RT) and markers of intestinal absorption in cervical cancer survivors (CCSs). We compared patient data with normative data from a reference population and explored the associations between cobalamin status and clinically significant diarrhea and depression. Methods and Materials: Fifty-five CCSs treated with RT in 1994-1999 were included in 2005 in a follow-up questionnaire study exploring physical and psychological symptoms. Blood tests, including serum (S)-vitamin B{sub 12,} S-methylmalonic acid, S-folate, erythrocyte-folate, and plasma homocysteine, were analyzed. Differences in median values between CCSs and reference populations were evaluated by using Wilcoxon tests. Associations between variables were examined by means of multiple regression analyses. Results: Median S-vitamin B{sub 12} level was significantly lower and median S-methylmalonic acid level was significantly higher in CCSs compared with the reference population (p < 0.001). Correction for renal function verified a likely cobalamin deficiency in 20% of CCSs (11 of 55). Diarrhea or depression was not significantly related to any of the mentioned markers of cobalamin or folate status. Fifteen percent of CCSs (8 of 55) had subnormal S-calcium values. Conclusions: Significant cobalamin deficiency was observed in 11 (20%) and low calcium level was observed in 8 CCSs (15%) 6-12 years after pelvic RT. Neither diarrhea nor depression was associated with this deficiency. Routine monitoring of S-vitamin B{sub 12} level is recommended, and regular intake of cobalamin should be considered in CCSs treated with RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Health-Related Quality of Life in Cervical Cancer Survivors: A Population-Based Survey

Purpose: In a population-based sample of cervical cancer survivors, health-related quality of life (HRQoL) was assessed 2-10 years postdiagnosis. Methods and Materials: All patients given a diagnosis of cervical cancer in 1995-2003 in the Eindhoven region, The Netherlands, and alive after Jan 2006 were identified through the cancer registry. Generic HRQoL (36-Item Short-Form Health Survey, EQ-5D), cervical cancer-specific HRQoL (European Organization for Research and Treatment of Cancer Quality-of-Life questionnaire cervical cancer module), and anxiety (6-item State Trait Anxiety Inventory) were assessed and compared with a reference population (n = 349). Data for tumor characteristics at diagnosis and disease progression were available. Results: A total of 291 women responded (69%), with a mean age of 53 {+-} 13 (SD) years (range, 31-88 years). Treatment had consisted of surgery (n = 195) or a combination of therapies (n = 75); one woman had not been treated. Of all women, 85% were clinically disease free, 2% had a recurrence/metastasis, and in 13%, this was unknown. After controlling for background characteristics (age, education, job and marital status, having children, and country of birth), generic HRQoL scale scores were similar to the reference population, except for worse mental health in survivors. The most frequent symptoms were crampy pain in the abdomen or belly (17%), urinary leakage (15%), menopausal symptoms (18%), and problems with sexual activity. Compared with the 6-10-year survivors, more sexual worry and worse body image were reported by the 2-5-year survivors. Compared with surgery only, especially primary radiotherapy was associated with an increased frequency of treatment-related side effects, also after controlling for age and disease stage at diagnosis and follow-up. Conclusions: Most cervical cancer survivors were coping well, although their mental health was worse than in the reference population. Even after 2-10 years, radiotherapy was associated with an increased frequency of treatment-related side effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Evaluation of Positioning Verification Using Digital Tomosynthesis and Bony Anatomy and Soft Tissues for Prostate Image-Guided Radiotherapy

Purpose: To evaluate on-board digital tomosynthesis (DTS) for patient positioning vs. two-dimensional (2D) radiography and three-dimensional cone beam (CBCT). Methods and Materials: A total of 92 image sessions from 9 prostate cancer patients were analyzed. An on-board image set was registered to a corresponding reference image set. Four pairs of image sets were used: digitally reconstructed radiographs vs. on-board orthogonal paired radiographs for the 2D method, coronal-reference DTS vs. on-board coronal DTS for the coronal-DTS method, sagittal-reference DTS vs. on-board sagittal DTS for the sagittal-DTS method, and planning CT vs. CBCT for the CBCT method. The registration results were compared. Results: The systematic errors in all methods were <1 mm/1{sup o}. When registering the bony anatomy, the mean vector difference was 0.21 {+-} 0.11 cm between 2D and CBCT, 0.11 {+-} 0.08 cm between CBCT and coronal DTS, and 0.14 {+-} 0.07 cm between CBCT and sagittal DTS. The correlation between CBCT to DTS was stronger (coefficient = 0.92-0.95) than the correlation between 2D and CBCT or DTS (coefficient = 0.81-0.83). When registering the soft tissue, the mean vector difference was 0.18 {+-} 0.11 cm between CBCT and coronal DTS and 0.29 {+-} 0.17 cm between CBCT and sagittal DTS. The correlation coefficient of CBCT to sagittal DTS and to coronal DTS was 0.84 and 0.92, respectively. Conclusion: DTS could provide equivalent results to CBCT when the bony anatomy is used as landmarks for prostate image-guided radiotherapy. For soft tissue-based positioning verification, coronal DTS produced equivalent results to CBCT, but sagittal DTS alone was insufficient. DTS could allow for comparable soft tissue-based target localization with faster scanning time and a lower imaging dose compared with CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unacceptable Cosmesis in a Protocol Investigating Intensity-Modulated Radiotherapy With Active Breathing Control for Accelerated Partial-Breast Irradiation

Purpose: To report interim cosmetic results and toxicity from a prospective study evaluating accelerated partial-breast irradiation (APBI) administered using a highly conformal external beam approach. Methods and Materials: We enrolled breast cancer patients in an institutional review board-approved prospective study of APBI using beamlet intensity-modulated radiotherapy (IMRT) at deep-inspiration breath-hold. Patients received 38.5 Gy in 3.85 Gy fractions twice daily. Dosimetric parameters in patients who maintained acceptable cosmesis were compared with those in patients developing unacceptable cosmesis in follow-up, using t-tests. Results: Thirty-four patients were enrolled; 2 were excluded from analysis because of fair baseline cosmesis. With a median follow-up of 2.5 years, new unacceptable cosmesis developed in 7 patients, leading to early study closure. We compared patients with new unacceptable cosmesis with those with consistently acceptable cosmesis. Retrospective analysis demonstrated that all but one plan adhered to the dosimetric requirements of the national APBI trial. The mean proportion of a whole-breast reference volume receiving 19.25 Gy (V50) was lower in patients with acceptable cosmesis than in those with unacceptable cosmesis (34.6% vs. 46.1%; p = 0.02). The mean percentage of this reference volume receiving 38.5 Gy (V100) was also lower in patients with acceptable cosmesis (15.5% vs. 23.0%; p = 0.02). Conclusions: The hypofractionated schedule and parameters commonly used for external beam APBI and prescribed by the ongoing national trial may be suboptimal, at least when highly conformal techniques such as IMRT with management of breathing motion are used. The V50 and V100 of the breast reference volume seem correlated with cosmetic outcome, and stricter limits may be appropriate in this setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distance-to-Agreement Investigation of Tomotherapy's Bony Anatomy-Based Autoregistration and Planning Target Volume Contour-Based Optimization

Purpose: To compare Tomotherapy's megavoltage computed tomography bony anatomy autoregistration with the best achievable registration, assuming no deformation and perfect knowledge of planning target volume (PTV) location. Methods and Materials: Distance-to-agreement (DTA) of the PTV was determined by applying a rigid-body shift to the PTV region of interest of the prostate from its reference position, assuming no deformations. Planning target volume region of interest of the prostate was extracted from the patient archives. The reference position was set by the 6 degrees of freedom (dof)—x, y, z, roll, pitch, and yaw—optimization results from the previous study at this institution. The DTA and the compensating parameters were calculated by the shift of the PTV from the reference 6-dof to the 4-dof—x, y, z, and roll—optimization. In this study, the effectiveness of Tomotherapy's 4-dof bony anatomy–based autoregistration was compared with the idealized 4-dof PTV contour-based optimization. Results: The maximum DTA (maxDTA) of the bony anatomy-based autoregistration was 3.2 ± 1.9 mm, with the maximum value of 8.0 mm. The maxDTA of the contour-based optimization was 1.8 ± 1.3 mm, with the maximum value of 5.7 mm. Comparison of Pearson correlation of the compensating parameters between the 2 4-dof optimization algorithms shows that there is a small but statistically significant correlation in y and z (0.236 and 0.300, respectively), whereas there is very weak correlation in x and roll (0.062 and 0.025, respectively). Conclusions: We find that there is an average improvement of approximately 1 mm in terms of maxDTA on the PTV going from 4-dof bony anatomy-based autoregistration to the 4-dof contour-based optimization. Pearson correlation analysis of the 2 4-dof optimizations suggests that uncertainties due to deformation and inadequate resolution account for much of the compensating parameters, but pitch variation also makes a statistically significant contribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Residual Setup Errors of Different IGRT Alignment Procedures for Head and Neck IMRT and the Resulting Dosimetric Impact

Purpose: To assess residual setup errors during head and neck radiation therapy and the resulting consequences for the delivered dose for various patient alignment procedures. Methods and Materials: Megavoltage cone beam computed tomography (MVCBCT) scans from 11 head and neck patients who underwent intensity modulated radiation therapy were used to assess setup errors. Each MVCBCT scan was registered to its reference planning kVCT, with seven different alignment procedures: automatic alignment and manual registration to 6 separate bony landmarks (sphenoid, left/right maxillary sinuses, mandible, cervical 1 [C1]-C2, and C7-thoracic 1 [T1] vertebrae). Shifts in the different alignments were compared with each other to determine whether there were any statistically significant differences. Then, the dose distribution was recalculated on 3 MVCBCT images per patient for every alignment procedure. The resulting dose-volume histograms for targets and organs at risk (OARs) were compared to those from the planning kVCTs. Results: The registration procedures produced statistically significant global differences in patient alignment and actual dose distribution, calling for a need for standardization of patient positioning. Vertically, the automatic, sphenoid, and maxillary sinuses alignments mainly generated posterior shifts and resulted in mean increases in maximal dose to OARs of >3% of the planned dose. The suggested choice of C1-C2 as a reference landmark appears valid, combining both OAR sparing and target coverage. Assuming this choice, relevant margins to apply around volumes of interest at the time of planning to take into account for the relative mobility of other regions are discussed. Conclusions: Use of different alignment procedures for treating head and neck patients produced variations in patient setup and dose distribution. With concern for standardizing practice, C1-C2 reference alignment with relevant margins around planning volumes seems to be a valid option.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Surgeons' Knowledge and Practices Regarding the Role of Radiation Therapy in Breast Cancer Management

Purpose: Population-based studies suggest underuse of radiation therapy, especially after mastectomy. Because radiation oncology is a referral-based specialty, knowledge and attitudes of upstream providers, specifically surgeons, may influence patients' decisions regarding radiation, including whether it is even considered. Therefore, we sought to evaluate surgeons' knowledge of pertinent risk information, their patterns of referral, and the correlates of surgeon knowledge and referral in specific breast cancer scenarios. Methods and Materials: We surveyed a national sample of 750 surgeons, with a 67% response rate. We analyzed responses from those who had seen at least 1 breast cancer patient in the past year (n=403), using logistic regression models to identify correlates of knowledge and appropriate referral. Results: Overall, 87% of respondents were general surgeons, and 64% saw >10 breast cancer patients in the previous year. In a scenario involving a 45-year-old undergoing lumpectomy, only 45% correctly estimated the risk of locoregional recurrence without radiation therapy, but 97% would refer to radiation oncology. In a patient with 2 of 20 nodes involved after mastectomy, 30% would neither refer to radiation oncology nor provide accurate information to make radiation decisions. In a patient with 4 of 20 nodes involved after mastectomy, 9% would not refer to radiation oncology. Fewer than half knew that the Oxford meta-analysis revealed a survival benefit from radiation therapy after lumpectomy (45%) or mastectomy (32%). Only 16% passed a 7-item knowledge test; female and more-experienced surgeons were more likely to pass. Factors significantly associated with appropriate referral to radiation oncology included breast cancer volume, tumor board participation, and knowledge. Conclusions: Many surgeons have inadequate knowledge regarding the role of radiation in breast cancer management, especially after mastectomy. Targeted educational interventions may improve the quality of care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A hybrid Boltzmann electrons and PIC ions model for simulating transient state of partially ionized plasma

A robust and stable numerical algorithm is developed for the hybrid method of particle-in-cell ions and Boltzmann distribution of electrons. A different approach to estimate the electron density reference and its proper potential reference is developed to overcome the problems of instability and divergence of previous approaches. The electron density reference is precisely calculated, the tolerance criterion is well-defined, and convergence is guaranteed by applying bi-section golden rule. To increase the rate of convergence, an external loop is incorporated with the bi-section golden rule to vary the brackets. The validity of the method is proved by comparing the simulated result with well-known analytical formula. The simulated sheath potential at a floating wall fit well to the analytic result. The collisionless ion kinetic energy acquired from the voltage difference between the pre-sheath and ion sheath does not violate the Bohm sheath criterion. For work that focuses on the plasma process at the ion sheath and not on the generation of plasma, this method saves simulation time by avoiding time consuming particle or kinetic model of electrons. The new approach reproduces the ion density profile at the ion sheaths region of a plasma with bi-Maxwellian electrons coupling with radio-frequency (RF) signal by introducing two Boltzmann relations to describe the cold and hot thermal electrons for the first time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Black carbon emissions and reduction potential in China: 2015–2050

Black carbon is a product of the incomplete combustion of carbonaceous fuels and has significant adverse effects on climate change, air quality, and human health. China has been a major contributor to global anthropogenic black carbon emissions. This study develops a black carbon inventory in China, using 2015 as the base year, and projects annual black carbon emissions in China for the period 2016–2050, under two scenarios: a Reference scenario and an Accelerated Reduction scenario. The study estimates that the total black carbon emissions in China in 2015 were 1100 thousand tons (kt), with residential use being the biggest contributor, accounting for more than half of the total black carbon emissions, followed by coke production, industry, agricultural waste burning, and transportation. This study then projects the total black carbon emissions in China in 2050 to be 278 kt in the Reference scenario and 86 kt in the Accelerated Reduction Scenario. Compared to the Reference scenario, the Accelerated Reduction scenario will achieve much faster and deeper black carbon reductions in all the sectors. The dramatic reductions can be attributed to the fuel switching in the residential sector, faster implementation of high-efficiency emission control measures in the industry, transportation, and coke production sectors, and faster phase-out of agricultural waste open burning. This analysis reveals the high potential of black carbon emission reductions across multiple sectors in China through the next thirty years.

54 ENVIRONMENTAL SCIENCES↗

Linking process and structure in the friction stir scribe joining of dissimilar materials: A computational approach with experimental support

We present that friction stir welding (FSW) is a popular technique to join dissimilar materials in numerous applications. The solid state nature of the process enables joining materials with strikingly different physical properties. For welds in lap configuration, an enhancement to this technology is made by introducing a short, hard insert, referred to as a cutting-scribe, at the bottom of the tool pin. The cutting-scribe induces deformation in the bottom plate which leads to the formation of mechanical interlocks or hook like structures at the interface of two materials. A thermo-mechanical computational model employing a coupled Eulerian-Lagrangian approach is developed to quantitatively capture the morphology of these interlocks during the FSW process. Simulations using this model are validated by experimental observations. In conclusion, the identified interface morphology coupled with the predicted temperature field from this process–structure model can be used to estimate the post-weld microstructure and joint strength.

36 MATERIALS SCIENCE↗

Hydrothermal synthesis and characterization of zirconia based catalysts

In this work, three equimolar mixed oxides ZrO{sub 2}/CeO{sub 2}, ZrO{sub 2}/TiO{sub 2}, ZrO{sub 2}/La{sub 2}O{sub 3} and a reference ZrO{sub 2} have been synthesized by hydrothermal method. The structural and surface properties of these materials have been fully characterized by X-ray diffraction, transmission electron microscopy, surface area measurement, chemical analysis, XPS, infrared spectroscopy after adsorption of pyridine and adsorption microcalorimetry of NH{sub 3} and SO{sub 2} probe molecules. All investigated mixed oxides are amphoteric and possess redox centers on their surface. Moreover, hydrothermal synthesis leads to catalysts with higher surface area and with better acid–base properties than classical coprecipitation method. Both Lewis and Brønsted acid sites are present on the surface of the mixed oxides. Compared to the other samples, the ZrO{sub 2}/TiO{sub 2} material appears to be the best candidate for further application in acid–base catalysis. - Graphical abstract: Mesoporous amorphous phase with a high surface area of titania zirconia mixed oxide obtained by hydrothermal preparation. - Highlights: • Three zirconia based catalysts and a reference were prepared by hydrothermal synthesis. • Mixed oxides present larger surface areas than the reference ZrO{sub 2}. • ZrO{sub 2}/TiO{sub 2} catalyst presents a mesoporous structure with high surface area. • ZrO{sub 2}/TiO{sub 2} catalyst presents simultaneously strong acidic and basic properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Individualized Margins in 3D Conformal Radiotherapy Planning for Lung Cancer: Analysis of Physiological Movements and Their Dosimetric Impacts

In conformal radiotherapy planning for lung cancer, respiratory movements are not taken into account when a single computed tomography (CT) scan is performed. This study examines tumor movements to design individualized margins to account for these movements and evaluates their dosimetric impacts on planning volume. Fifteen patients undergoing CT-based planning for radical radiotherapy for localized lung cancer formed the study cohort. A reference plan was constructed based on reference gross, clinical, and planning target volumes (rGTV, rCTV, and rPTV, respectively). The reference plans were compared with individualized plans using individualized margins obtained by using 5 serial CT scans to generate individualized target volumes (iGTV, iCTV, and iPTV). Three-dimensional conformal radiation therapy was used for plan generation using 6- and 23-MV photon beams. Ten plans for each patient were generated and dose-volume histograms (DVHs) were calculated. Comparisons of volumetric and dosimetric parameters were performed using paired Student t-tests. Relative to the rGTV, the total volume occupied by the superimposed GTVs increased progressively with each additional CT scans. With the use of all 5 scans, the average increase in GTV was 52.1%. For the plans with closest dosimetric coverage, target volume was smaller (iPTV/rPTV ratio 0.808) but lung irradiation was only slightly decreased. Reduction in the proportion of lung tissue that received 20 Gy or more outside the PTV (V20) was observed both for 6-MV plans (-0.73%) and 23-MV plans (-0.65%), with p = 0.02 and p = 0.04, respectively. In conformal RT planning for the treatment of lung cancer, the use of serial CT scans to evaluate respiratory motion and to generate individualized margins to account for these motions produced only a limited lung sparing advantage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Refine your search to explore more results.