Search NASA⌕ Search

SEARCH · Search NASA

Results for “software optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Data Integration for the Generation of High Resolution Reservoir Models

The goal of this three-year project was to develop a theoretical basis and practical technology for the integration of geologic, production and time-lapse seismic data in a way that makes best use of the information for reservoir description and reservoir performance predictions. The methodology and practical tools for data integration that were developed in this research project have been incorporated into computational algorithms that are feasible for large scale reservoir simulation models. As the integration of production and seismic data require calibrating geological/geostatistical models to these data sets, the main computational tool is an automatic history matching algorithm. The following specific goals were accomplished during this research. (1) We developed algorithms for calibrating the location of the boundaries of geologic facies and the distribution of rock properties so that production and time-lapse seismic data are honored. (2) We developed and implemented specific procedures for conditioning reservoir models to time-lapse seismic data. (3) We developed and implemented algorithms for the characterization of measurement errors which are needed to determine the relative weights of data when conditioning reservoir models to production and time-lapse seismic data by automatic history matching. (4) We developed and implemented algorithms for the adjustment of relative permeability curves during the history matching process. (5) We developed algorithms for production optimization which accounts for geological uncertainty within the context of closed-loop reservoir management. (6) To ensure the research results will lead to practical public tools for independent oil companies, as part of the project we built a graphical user interface for the reservoir simulator and history matching software using Visual Basic.

02 PETROLEUM↗

The Status of USITER Diagnostic Port Plug Neutronics Analysis Using Attila

USITER is one of seven partner domestic agencies (DA) contributing components to the ITER project. Four diagnostic port plug packages (two equatorial ports and two upper ports) will be engineered and fabricated by Princeton Plasma Physics Lab (PPPL). Diagnostic port plugs as illustrated in Fig. 1 are large primarily stainless steel structures that serve several roles on ITER. The port plugs are the primary vacuum seal and tritium confinement barriers for the vessel. The port plugs also house several plasma diagnostic systems and other machine service equipment. Finally, each port plug must shield high energy neutrons and gamma photons from escaping and creating radiological problems in maintenance areas behind the port plugs. The optimization of the balance between adequate shielding and the need for high performance, high throughput diagnostics systems is the focus of this paper. Neutronics calculations are also needed for assessing nuclear heating and nuclear damage in the port plug and diagnostic components. Attila, the commercially available discrete-ordinates software package, is used for all diagnostic port plug neutronics analysis studies at PPPL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Fluid Dynamics Uncertainty Quantification Challenge Problem: XFOIL vs. MFOIL

Uncertainty quantification (UQ) has become more critical in aerospace engineering due to the growing dependence on computational tools for design optimization and performance analyses of aerospace vehicles. Even though the significance of UQ in assessing the credibility of computational analyses is well recognized, its costs and complexity impede its integration into standard practices, particularly in computational fluid dynamics (CFD) and other fluid analyses. This paper presents a UQ study for low-fidelity computational aerodynamics analyses with XFOIL and mfoil (i.e., the MATLAB version of XFOIL with several implementation modifications); these tools are utilized widely in both research and education. The main contributions of this paper are as follows: 1) improved precision in quantifying the uncertainty of the baseline Monte Carlo results used to benchmark surrogate modeling techniques for UQ, 2) quantification of the effect of the implementation differences between XFOIL and mfoil on solution quantities of interest (QoIs), such as lift and pitching moment coefficients, and 3) development of an open-source UQ library for use with XFOIL and mfoil, which has educational values and helps promote UQ for fluid analyses with aerospace applications. Results and discussions revolve around cases 1-4 of the challenge problem posed by the AIAA Fluid Dynamics Technical Committee’s Uncertainty Quantification Discussion Group (UQDG). In case 3, this work employs CFDverify, an open-source solution verification software, to quantify the discretization error and evaluate the extrapolated QoIs based on the grid convergence index (GCI). This UQ study differentiates itself from previous studies in the rigor of handling baseline Monte Carlo uncertainty and in including mfoil, which is a more accessible alternative to XFOIL. Finally, despite the growing computing power, low-fidelity computational tools remain valuable, such as for aerodynamic shape optimization at Mach numbers below 0.65 and low-to-mid Reynolds numbers.

Lay, Aidan S [University of Tennessee, Knoxville (↗

Computing molecular excited states on a D-Wave quantum annealer

Abstract The possibility of using quantum computers for electronic structure calculations has opened up a promising avenue for computational chemistry. Towards this direction, numerous algorithmic advances have been made in the last five years. The potential of quantum annealers, which are the prototypes of adiabatic quantum computers, is yet to be fully explored. In this work, we demonstrate the use of a D-Wave quantum annealer for the calculation of excited electronic states of molecular systems. These simulations play an important role in a number of areas, such as photovoltaics, semiconductor technology and nanoscience. The excited states are treated using two methods, time-dependent Hartree–Fock (TDHF) and time-dependent density-functional theory (TDDFT), both within a commonly used Tamm–Dancoff approximation (TDA). The resulting TDA eigenvalue equations are solved on a D-Wave quantum annealer using the Quantum Annealer Eigensolver (QAE), developed previously. The method is shown to reproduce a typical basis set convergence on the example $$\hbox {H}_2$$ H 2 molecule and is also applied to several other molecular species. Characteristic properties such as transition dipole moments and oscillator strengths are computed as well. Three potential energy profiles for excited states are computed for $$\hbox {NH}_3$$ NH 3 as a function of the molecular geometry. Similar to previous studies, the accuracy of the method is dependent on the accuracy of the intermediate meta-heuristic software called qbsolv.

74 ATOMIC AND MOLECULAR PHYSICS↗

The International Database of Efficient Appliances (IDEA): A new tool to support appliance energy-efficiency deployment

Appliance energy-efficiency programs are a central component of many countries’ energy-policy portfolios. A major barrier to optimal implementation of these programs is lack of data to determine market baselines, assess the potential for cost-effective energy savings, and track markets over time to evaluate and verify program impacts. To address this gap, we have developed the International Database of Efficient Appliances (IDEA), a suite of software tools that automatically gathers data that is currently dispersed across various online sources and compiles it into a unified repository of information on efficiency, price, and features for a diversity of appliances and devices in markets around the world. In this article we describe the framework and functionality of IDEA, and we demonstrate its power as a resource for research and policy development related to appliance energy efficiency. Using IDEA data for refrigerators in China and India, we assess the potential for cost-effective energy savings within each market by computing robust indicators that can also be easily compared across different appliances and markets. We find that significant cost-effective savings are available on both markets. We discuss implications for the development of future energy-efficiency deployment programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Xrootd to federate regional storage

While the LHC data movement systems have demonstrated the ability to move data at the necessary throughput, we have identified two weaknesses: the latency for physicists to access data and the complexity of the tools involved. To address these, both ATLAS and CMS have begun to federate regional storage systems using Xrootd. Xrootd, referring to a protocol and implementation, allows us to provide data access to all disk-resident data from a single virtual endpoint. This redirector discovers the actual location of the data and redirects the client to the appropriate site. The approach is particularly advantageous since typically the redirection requires much less than 500 milliseconds and the Xrootd client is conveniently built into LHC physicists analysis tools. Currently, there are three regional storage federations - a US ATLAS region, a European CMS region, and a US CMS region. The US ATLAS and US CMS regions include their respective Tier 1, Tier 2 and some Tier 3 facilities, a large percentage of experimental data is available via the federation. Additionally, US ATLAS has begun studying low-latency regional federations of close-by sites. From the base idea of federating storage behind an endpoint, the implementations and use cases diverge. The CMS software framework is capable of efficiently processing data over high-latency links, so using the remote site directly is comparable to accessing local data. The ATLAS processing model allows a broad spectrum of user applications with varying degrees of performance with regard to latency, a particular focus has been optimizing n-tuple analysis. Both VOs use GSI security. ATLAS has developed a mapping of VOMS roles to specific file system authorizations, while CMS has developed callouts to the site's mapping service. Each federation presents a global namespace to users. For ATLAS, the global-to-local mapping is based on a heuristic-based lookup from the site's local file catalog, while CMS does the mapping based on translations given in a configuration file. We will also cover the latest usage statistics and interesting use cases that have developed over the previous 18 months.

Bauerdick, L.↗

SU-C-303-06: Treatment Planning Study for Non-Invasive Cardiac Arrhythmia Ablation with Scanned Carbon Ions in An Animal Model

Purpose: Scanned carbon ion beams might offer a non-invasive alternative treatment for cardiac arrhythmia, which are a major health-burden. We studied the feasibility of this procedure in an animal model. The underlying treatment planning and motion mitigation strategies will be presented. Methods: The study was carried out in 15 pigs, randomly distributed to 3 target groups: atrioventricular node (AVN, 8 animals with 25, 40, and 55 Gy target dose), left ventricular free-wall (LV, 4 animals with 40 Gy) and superior pulmonary vein (SPV, 3 animals with 40 Gy). Breathing motion was suppressed by repeated enforced breathholds at end exhale. Cardiac motion was mitigated by an inhomogeneous rescanning scheme with up to 15 rescans. The treatment planning was performed using the GSI in-house software TRiP4D on cardiac-gated 4DCTs, applying a range-considering ITV based on an extended CTV. For AVN and SPV isotropic 5 mm margins were applied to the CTV, while for the LV 2mm+2% range margins were used. The opposing fields for AVN and LV targets were optimized independently (SFUD), while SPV treatments were optimized as IMPT deliveries, including dose restrictions to the radiosensitive AVN. Results: Median value of D{sub 95} over all rescanning simulations was 99.1% (AVN), 98.0% (SPV) and 98.3% (LV) for the CTV and 94.7% (AVN) and 92.7% (SPV) for the PTV, respectively. The median D{sub 5}-D{sub 95} was improved with rescanning compared to unmitigated delivery from 13.3 to 6.5% (CTV) and from 23.4 to 11.6% (PTV). ICRP dose limits for aorta, trachea, esophagus and skin were respected. The maximal dose in the coronary arteries was limited to 30 Gy. Conclusion: We demonstrated the feasibility of a homogeneous dose delivery to different cardiac structures in a porcine model using a time-optimized inhomogeneous rescanning scheme. The presented treatment planning strategies were applied in a pig study with the analysis ongoing. Funding: This work was supported in part by the Helmholtz Association, the American Heart Association Midwest Affiliate Postdoctoral Fellowship Grant, the Mayo Clinic Foundation, and the Goldsmith Foundation.

60 APPLIED LIFE SCIENCES↗

SU-F-J-195: On the Performance of Four Dual Energy CT Formalisms for Extracting Proton Stopping Powers

Purpose: Dual energy CT can predict stopping power ratios (SPR) for ion therapy treatment planning. Several approaches have been proposed recently, however accuracy and practicability in a clinical workflow are unaddressed. The aim of this work is to provide a fair comparison of available approaches in a human-like phantom to find the optimal method for tissue characterization in a clinical situation. Methods: The SPR determination accuracy is investigated using simulated DECT images. A virtual human-like phantom is created containing 14 different standard human tissues. SECT (120 kV) and DECT images (100 kV and 140 kV Sn) are simulated using the software ImaSim. The single energy CT (SECT) stoichiometric calibration method and four recently published calibration-based DECT methods are implemented and used to predict the SPRs from simulated images. The difference between SPR predictions and theoretical SPR are compared pixelwize. Mean, standard deviation and skewness of the SPR difference distributions are used as measures for bias, dispersion and symmetry. Results: The average SPR differences and standard deviations are (0.22 ± 1.27)% for SECT, and A) (−0.26 ± 1.30)%, B) (0.08 ± 1.12)%, C) (0.06 ± 1.15)% and D) (−0.05 ± 1.05)% for the four DECT methods. While SPR prediction using SECT is showing a systematic error on SPR, the DECT methods B, C and D are unbiased. The skewness of the SECT distribution is 0.57%, and A) −0.19%, B) −0.56%, C) −0.29% and D) −0.07% for DECT methods respectively. Conclusion: The here presented DECT methods B, C and D outperform the commonly used SECT stoichiometric calibration. These methods predict SPR accurately without a bias and within ± 1.2% (68th percentile). This indicates that DECT potentially improves accuracy of range predictions in proton therapy. A validation of these findings using clinical CT images of real tissues is necessary.

60 APPLIED LIFE SCIENCES↗

SU-F-T-367: Using PRIMO, a PENELOPE-Based Software, to Improve the Small Field Dosimetry of Linear Accelerators

Purpose: To calculate output correction factors for Varian Clinac 2100iX beams for seven small field detectors and use the values to determine the small field output factors for the linacs at Karolinska university hospital. Methods: Phase space files (psf) for square fields between 0.25cm and 10cm were calculated using the PENELOPE-based PRIMO software. The linac MC-model was tuned by comparing PRIMO-estimated and experimentally determined depth doses and lateral dose-profiles for 40cmx40cm fields. The calculated psf were used as radiation sources to calculate the correction factors of IBA and PTW detectors with the code penEasy/PENELOPE. Results: The optimal tuning parameters of the MClinac model in PRIMO were 5.4 MeV incident electron energy and zero energy spread, focal spot size and beam divergence. Correction factors obtained for the liquid ion chamber (PTW-T31018) are within 1% down to 0.5 cm fields. For unshielded diodes (IBA-EFD, IBA-SFD, PTW-T60017 and PTW-T60018) the corrections are up to 2% at intermediate fields (>1cm side), becoming down to −11% for fields smaller than 1cm. The shielded diode (IBA-PFD and PTW-T60016) corrections vary with field size from 0 to −4%. Volume averaging effects are found for most detectors in the presence of 0.25cm fields. Conclusion: Good agreement was found between correction factors based on PRIMO-generated psf and those from other publications. The calculated factors will be implemented in output factor measurements (using several detectors) in the clinic. PRIMO is a userfriendly general code capable of generating small field psf and can be used without having to code own linac geometries. It can therefore be used to improve the clinical dosimetry, especially in the commissioning of linear accelerators. Important dosimetry data, such as dose-profiles and output factors can be determined more accurately for a specific machine, geometry and setup by using PRIMO and having a MC-model of the detector used.

43 PARTICLE ACCELERATORS↗

In Recognition of Sandia's SCRM Program, Delivering Over 500 Subcontractor Risk Assessments in 2018

The globalization of modern supply chains has resulted in many new risks to Sandia's NW programs and mission. The potential impact of counterfeit products, tampering, theft, malicious software, poor manufacturing and/or development practices, and the influence of foreign governments has become more obvious as new threats and compromises continuously emerge. The Supply Chain Risk Management (SCRM) team was formed specifically to understand and address these risks. We were able to coalesce around these principles to develop and optimize an effective risk assessment process for critical suppliers, called Subcontractor Risk Assessments (SRAs). These elevated screening techniques are planned and delivered in a cost-effective way for Sandia's programs (no increase to purchasing burden rates) and also demonstrate due diligence to DOE/NNSA as a component of Sandia's overall SCRM strategy. SRAs are communicated in a concise 1-page format complete with recommendations as well as links to reference materials for those who require additional details about the SRA process and results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Search for Joint Multimessenger Signals from Potential Galactic Cosmic-Ray Accelerators with HAWC and IceCube

The origin of high-energy galactic cosmic rays is yet to be understood, but some galactic cosmic-ray accelerators can accelerate cosmic rays up to PeV energies. The high-energy cosmic rays are expected to interact with the surrounding material or radiation, resulting in the production of gamma-rays and neutrinos. To optimize for the detection of such associated production of gamma-rays and neutrinos for a given source morphology and spectrum, a multimessenger analysis that combines gamma-rays and neutrinos is required. In this study, we use the Multi-Mission Maximum Likelihood framework with IceCube Maximum Likelihood Analysis software and HAWC Accelerated Likelihood to search for a correlation between 22 known gamma-ray sources from the third HAWC gamma-ray catalog and 14 yr of IceCube track-like data. No significant neutrino emission from the direction of the HAWC sources was found. We report the best-fit gamma-ray model and 90% CL neutrino flux limit from the 22 sources. From the neutrino flux limit, we conclude that, for five of the sources, the gamma-ray emission observed by HAWC cannot be produced purely from hadronic interactions. We report the limit for the fraction of gamma-rays produced by hadronic interactions for these five sources.

79 ASTRONOMY AND ASTROPHYSICS↗

DMTN-036: jointcal: Simultaneous Astrometry & Photometry for thousands of Exposures with Large CCD Mosaics

The jointcal package simultaneously optimizes the astrometric and photometric calibrations of a set of astronomical images. In principle and often in practice, this approach produces distortion and thoroughput models which are more precise than when fitted independently. This is especially true when the images are deeper than the astrometric reference catalogs. In the "Astromatic" software suite, this simultaneous astrometry functionality is fulfilled by "SCAMP". The code we describe here has similar aims, but follows a slightly different route. Jointcal is built on top of the the LSST Data Management software stack.

79 ASTRONOMY AND ASTROPHYSICS↗

Mesh Adaptive Search Optimization in SERPENT2 Stereolithography Geometry

SERPENT2 Monte Carlo program has the capability to model reactor cores by stereolithography (STL) geometry. In this geometry, volumes are defined by the union of triangulated surfaces. Using the STL geometry offers unique benefits, including: 1) the model can be printed on 3D printers; 2) the possibility to use directly geometrical models from Computer-Aided Design (CAD); 3) the capability to perform multi-physics simulations coupling neutronics, thermal-hydraulics, and material science computations. In this work the STL geometry has been created by the CUBIT software, which is designed for finite elements mesh generation. The materials in the STL geometry have been assigned by a simple C program using the colors of the volumes in the CUBIT model. The goal of this work is to minimize the SERPENT2 computing time using mesh adaptive search algorithms. The basic idea is to split the geometry of the core into two zones: one zone containing the fuel elements (including the moderator and the coolant) and the other containing the reflector (and the target zone of the core, if it is driven by an external neutron source). By performing this splitting, two separate meshes are used, which results in a considerable computing time saving. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TeraChem: Accelerating electronic structure and ab initio molecular dynamics with graphical processing units

Developed over the past decade, TeraChem is an electronic structure and ab initio molecular dynamics software package designed from the ground up to leverage graphics processing units (GPUs) to perform large-scale ground and excited state quantum chemistry calculations in the gas and the condensed phase. TeraChem’s speed stems from the reformulation of conventional electronic structure theories in terms of a set of individually optimized high-performance electronic structure operations (e.g., Coulomb and exchange matrix builds, one- and two-particle density matrix builds) and rank-reduction techniques (e.g., tensor hypercontraction). Recent efforts have encapsulated these core operations and provided language-agnostic interfaces. Finally, this greatly increases the accessibility and flexibility of TeraChem as a platform to develop new electronic structure methods on GPUs and provides clear optimization targets for emerging parallel computing architectures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On-lattice kinetic Monte Carlo approaches for modeling molecular anisotropy in resveratrol crystallization

Stilbenes are a class of organic compounds with broad-ranging pharmaceutical and agricultural applications, which are typically isolated and purified through recrystallization. We are motivated by reducing experimental waste and optimizing yield via developing predictive simulations for processing-dependent crystal morphologies. Using resveratrol as a model stilbene system, we have developed an approach for simulating crystallization with molecular resolution using on-lattice kinetic Monte Carlo. In this work, we highlight modifications to the Stochastic Parallel PARticle Kinetic Simulator (SPPARKS) software package, which were essential to this application. Key enhancements include the incorporation of non-orthogonal cell shapes and monomer anisotropy approximations using bound hard spheres. This new SPPARKS application has been applied to resveratrol with attachment energy libraries obtained from density functional theory, resulting in excellent agreement with experimental morphology prediction.

crystallization↗

SU-E-J-114: A Practical Hybrid Method for Improving the Quality of CT-CBCT Deformable Image Registration for Head and Neck Radiotherapy

Purpose: Accurate deformable image registration (DIR) between CT and CBCT in H&N is challenging. In this study, we propose a practical hybrid method that uses not only the pixel intensities but also organ physical properties, structure volume of interest (VOI), and interactive local registrations. Methods: Five oropharyngeal cancer patients were selected retrospectively. For each patient, the planning CT was registered to the last fraction CBCT, where the anatomy difference was largest. A three step registration strategy was tested; Step1) DIR using pixel intensity only, Step2) DIR with additional use of structure VOI and rigidity penalty, and Step3) interactive local correction. For Step1, a public-domain open-source DIR algorithm was used (cubic B-spline, mutual information, steepest gradient optimization, and 4-level multi-resolution). For Step2, rigidity penalty was applied on bony anatomies and brain, and a structure VOI was used to handle the body truncation such as the shoulder cut-off on CBCT. Finally, in Step3, the registrations were reviewed on our in-house developed software and the erroneous areas were corrected via a local registration using level-set motion algorithm. Results: After Step1, there were considerable amount of registration errors in soft tissues and unrealistic stretching in the posterior to the neck and near the shoulder due to body truncation. The brain was also found deformed to a measurable extent near the superior border of CBCT. Such errors could be effectively removed by using a structure VOI and rigidity penalty. The rest of the local soft tissue error could be corrected using the interactive software tool. The estimated interactive correction time was approximately 5 minutes. Conclusion: The DIR using only the image pixel intensity was vulnerable to noise and body truncation. A corrective action was inevitable to achieve good quality of registrations. We found the proposed three-step hybrid method efficient and practical for CT/CBCT registrations in H&N. My department receives grant support from Industrial partners: (a) Varian Medical Systems, Palo Alto, CA, and (b) Philips HealthCare, Best, Netherlands.

60 APPLIED LIFE SCIENCES↗

Quantitative Analysis of Color Differences within High Contrast, Low Power Reversible Electrophoretic Displays

Here, quantitative color analysis is performed on videos of high contrast, low power reversible electrophoretic deposition (EPD)-based displays operated under different applied voltages. This analysis is coded in an open-source software, relies on a color differentiation metric, ΔE * 00 , derived from digital video, and provides an intuitive relationship between the operating conditions of the devices and their performance. Time-dependent ΔE * 00 color analysis reveals color relaxation behavior, recoverability for different voltage sequences, and operating conditions that can lead to optimal performance.

36 MATERIALS SCIENCE↗

Priority research directions for in situ data management: Enabling scientific discovery from diverse data sources

In January 2019, the US Department of Energy, Office of Science program in Advanced Scientific Computing Research, convened a workshop to identify priority research directions (PRDs) for in situ data management (ISDM). A fundamental finding of this workshop is that the methodologies used to manage data among a variety of tasks in situ can be used to facilitate scientific discovery from many different data sources—simulation, experiment, and sensors, for example—and that being able to do so at numerous computing scales will benefit real-time decision-making, design optimization, and data-driven scientific discovery. This article describes six PRDs identified by the workshop, which highlight the components and capabilities needed for ISDM to be successful for a wide variety of applications—making ISDM capabilities more pervasive, controllable, composable, and transparent, with a focus on greater coordination with the software stack and a diversity of fundamentally new data algorithms.

97 MATHEMATICS AND COMPUTING↗

Refine your search to explore more results.