Search NASA⌕ Search

SEARCH · Search NASA

Results for “structure imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Radiation doses in volume-of-interest breast computed tomography—A Monte Carlo simulation study

Purpose: Cone beam breast computed tomography (breast CT) with true three-dimensional, nearly isotropic spatial resolution has been developed and investigated over the past decade to overcome the problem of lesions overlapping with breast anatomical structures on two-dimensional mammographic images. However, the ability of breast CT to detect small objects, such as tissue structure edges and small calcifications, is limited. To resolve this problem, the authors proposed and developed a volume-of-interest (VOI) breast CT technique to image a small VOI using a higher radiation dose to improve that region’s visibility. In this study, the authors performed Monte Carlo simulations to estimate average breast dose and average glandular dose (AGD) for the VOI breast CT technique. Methods: Electron–Gamma-Shower system code-based Monte Carlo codes were used to simulate breast CT. The Monte Carlo codes estimated were validated using physical measurements of air kerma ratios and point doses in phantoms with an ion chamber and optically stimulated luminescence dosimeters. The validated full cone x-ray source was then collimated to simulate half cone beam x-rays to image digital pendant-geometry, hemi-ellipsoidal, homogeneous breast phantoms and to estimate breast doses with full field scans. 13-cm in diameter, 10-cm long hemi-ellipsoidal homogeneous phantoms were used to simulate median breasts. Breast compositions of 25% and 50% volumetric glandular fractions (VGFs) were used to investigate the influence on breast dose. The simulated half cone beam x-rays were then collimated to a narrow x-ray beam with an area of 2.5 × 2.5 cm{sup 2} field of view at the isocenter plane and to perform VOI field scans. The Monte Carlo results for the full field scans and the VOI field scans were then used to estimate the AGD for the VOI breast CT technique. Results: The ratios of air kerma ratios and dose measurement results from the Monte Carlo simulation to those from the physical measurements were 0.97 ± 0.03 and 1.10 ± 0.13, respectively, indicating that the accuracy of the Monte Carlo simulation was adequate. The normalized AGD with VOI field scans was substantially reduced by a factor of about 2 over the VOI region and by a factor of 18 over the entire breast for both 25% and 50% VGF simulated breasts compared with the normalized AGD with full field scans. The normalized AGD for the VOI breast CT technique can be kept the same as or lower than that for a full field scan with the exposure level for the VOI field scan increased by a factor of as much as 12. Conclusions: The authors’ Monte Carlo estimates of normalized AGDs for the VOI breast CT technique show that this technique can be used to markedly increase the dose to the breast and thus the visibility of the VOI region without increasing the dose to the breast. The results of this investigation should be helpful for those interested in using VOI breast CT technique to image small calcifications with dose concern.

60 APPLIED LIFE SCIENCES↗

Visualizing Electric and Magnetic Field Coupling in Au-Nanorod Trimer Structures via Stimulated Electron Energy Gain and Cathodoluminescence Spectroscopy: Implications for Meta-Atom Imaging

In this work, trimer meta-atoms composed of three gold rods in an equilateral triangular geometry were fabricated, and their near-field plasmonic responses were characterized via electron energy loss (EEL), cathodoluminescence (CL), and stimulated electron energy loss/gain (sEEL/sEEG) spectroscopy. The trimer structure hybridizes into a low-energy mode with all three rods coupling in-phase, which produces a circulating current and thus a magnetic field. The next highest-energy mode consists of two rods coupling out-of-phase and produces a net electric dipole. We investigate the near fields of hybridized magnetic and electric modes via EEL and CL and correlate their spectral characteristics and intensity maps. Then, by changing the length of the trimer rods, we tune the magnetic and electric modes to our laser energy and characterize the excited state via sEEL/sEEG spectroscopy. Exploration of the tilt dependence, relative to the optical source, of the two modes reveals that the electric mode sEEG intensity increases more than the expected sin 2 (θ) dependence of the optical electric field coupling (see the Supporting Information for a detailed description). After correcting for the tail of the close-proximity electric mode, we demonstrate sEEG via coupling of the magnetic component of the optical field to the magnetic meta-atoms, which has the expected cos 2 (θ) tilt dependence. This realization opens the possibility to explore the nanoscale excited-state near-field imaging of other magnetic meta-atom structures.

36 MATERIALS SCIENCE↗

Microfocus x-ray imaging of traceable pointlike {sup 22}Na sources for quality control

Purpose: The purpose of this study is to propose a microfocus x-ray imaging technique for observing the internal structure of small radioactive sources and evaluating geometrical errors quantitatively, and to apply this technique to traceable pointlike {sup 22}Na sources, which were designed for positron emission tomography calibration, for the purpose of quality control of the pointlike sources. Methods: A microfocus x-ray imaging system with a focus size of 0.001 mm was used to obtain projection x-ray images and x-ray CT images of five pointlike source samples, which were manufactured during 2009-2012. The obtained projection and tomographic images were used to observe the internal structure and evaluate geometrical errors quantitatively. Monte Carlo simulation was used to evaluate the effect of possible geometrical errors on the intensity and uniformity of 0.511 MeV annihilation photon pairs emitted from the sources. Results: Geometrical errors were evaluated with sufficient precision using projection x-ray images. CT images were used for observing the internal structure intuitively. As a result, four of the five examined samples were within the tolerance to maintain the total uncertainty below {+-}0.5%, given the source radioactivity; however, one sample was found to be defective. Conclusions: This quality control procedure is crucial and offers an important basis for using the pointlike {sup 22}Na source as a basic calibration tool. The microfocus x-ray imaging approach is a promising technique for visual and quantitative evaluation of the internal geometry of small radioactive sources.

07 ISOTOPE AND RADIATION SOURCES↗

An innovative digital image correlation technique for in-situ process monitoring of composite structures in large scale additive manufacturing

As additive manufacturing (AM) continues to develop and become a standardized manufacturing method, there will be a continued need to provide in-situ monitoring during the manufacturing of polymer composite printed components. Thermal residual stress is a primary cause of failures such as interlayer disbonds or delamination, micro cracking, and dimensional instability, which can occur during or after the build. Here, we report a novel digital image correlation (DIC) adaptation to monitor thermal residual stresses during the entire print process for large-scale AM. In this work, DIC has been investigated (a) by the natural speckle produced by the polymer surface for correlation, (b) to monitor AM build, and (c) to evaluate the effect of thermal residual stress on warpage of the printed component. The natural speckle pattern of the AM material resulted in a respectable 3.57% error compared to the traditional painted speckle pattern of 3.05% error. DIC measured a 190% increase in vertical displacement at the edge of the wall compared to the center, indicating warpage during AM. This work is a step towards a non-intrusive residual stress measuring technique using DIC for large-scale AM.

36 MATERIALS SCIENCE↗

Advanced applications: an overview

Applications of materials in white-light optical imaging, remote-sensing systems are discussed. Image formation in terms of wavefronts and the influence of materials on the quality of images is given. The rationale for why some space optics structures are large is presented.

image quality structure material↗

A Multiwavelength Study of Coronal Structure: A Simultaneous Observation from NIXT and YOHKOH

Solar soft X-ray images taken simultaneously by the Yohkoh and the Normal Incidence X-ray Telescope (NIXT) reveal significantly different coronal structures. Coronal loops are more clearly seen in the Yohkoh images, and the isolated island-like structures seen in the NIXT image have been found to correspond to the footpoints of the Yohkoh loops. The difference is due to the difference in the temperature response of the telescopes: NIXT is sensitive to temperatures ranging from 0.9 to 3 MK, while Yohkoh is more sensitive to temperatures above 2.5 MK. The morphological differences reflect the multi-temperature (1-5 MK) nature of the solar coronal plasmas.

Golub, Leon↗

Effect of solvent/polymer infiltration and irradiation on microstructure and tensile properties of carbon nanotube yarns

Recently carbon nanotube (CNT) yarns have been gaining importance as an approach to harvest the excellent properties of the CNTs. However, the properties of CNT yarns at this stage are well below the expected value. Investigation of the structure of CNT yarns and possible approaches to enhance the strength and modulus are reported. Scanning electron microscopy and focused ion beam imaging reveal the inherently porous structure and poor orientation, emphasizing the need to enhance packing of CNT bundles in the yarns for increased strength and modulus. Densification of CNT yarn by toluene or polystyrene increases the strength by 140 or 172 % and modulus by 79 or 218 %, respectively, as compared to that of the pristine yarn. E-beam irradiation was investigated as a means to introduce crosslinking and enhanced internanotubes bonding to increase strength and modulus. However, the irradiation resulted in generation of defects and damages to the yarn contributing to reduction in strength and modulus. Raman spectroscopy studies on the irradiated samples reveal the change in bonding characteristics resulting in poor mechanical properties. As a result, denser packing of nanotubes and increased interaction without any damage is the key to improve the properties of CNT yarns.

36 MATERIALS SCIENCE↗

Radiation image reconstruction and uncertainty quantification using a Gaussian process prior

We propose a complete framework for Bayesian image reconstruction and uncertainty quantification based on a Gaussian process prior (GPP) to overcome limitations of maximum likelihood expectation maximization (ML-EM) image reconstruction algorithm. The prior distribution is constructed with a zero-mean Gaussian process (GP) with a choice of a covariance function, and a link function is used to map the Gaussian process to an image. Unlike many other maximum a posteriori approaches, our method offers highly interpretable hyperparamters that are selected automatically with the empirical Bayes method. Furthermore, the GP covariance function can be modified to incorporate a priori structural priors, enabling multi-modality imaging or contextual data fusion. Lastly, we illustrate that our approach lends itself to Bayesian uncertainty quantification techniques, such as the preconditioned Crank–Nicolson method and the Laplace approximation. The proposed framework is general and can be employed in most radiation image reconstruction problems, and we demonstrate it with simulated free-moving single detector radiation source imaging scenarios. We compare the reconstruction results from GPP and ML-EM, and show that the proposed method can significantly improve the image quality over ML-EM, all the while providing greater understanding of the source distribution via the uncertainty quantification capability. Furthermore, significant improvement of the image quality by incorporating a structural prior is illustrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser-induced incandescence measurements of soot in turbulent pool fires

We present what we believe to be the first application of the laser-induced incandescence (LII) technique to large-scale fire testing. The construction of an LII instrument for fire measurements is presented in detail. Soot volume fraction imaging from 2 m diameter pool fires burning blended toluene/methanol liquid fuels is demonstrated along with a detailed report of measurement uncertainty in the challenging pool fire environment. Our LII instrument relies upon remotely located laser, optical, and detection systems and the insertion of water-cooled, fiber-bundle-coupled collection optics into the fire plume. Calibration of the instrument was performed using an ethylene/air laminar diffusion flame produced by a Santoro-type burner, which allowed for the extraction of absolute soot volume fractions from the LII images. Single-laser-shot two-dimensional images of the soot layer structure are presented with very high volumetric spatial resolution of the order of 10{sup -5} cm{sup 3}. Probability density functions of the soot volume fraction fluctuations are constructed from the large LII image ensembles. The results illustrate a highly intermittent soot fluctuation field with potentially large macroscale soot structures and clipped soot probability densities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Digital enhancement of SAR imagery as an aid in geologic data extraction

The geological data content of Seasat A SAR imagery was assessed by correlating images of the Southern Appalachians with optical and digital techniques using a digital enhancement algorithm. The evaluation was performed in terms of lithology, lineaments, and geological structure. Digital correlation of the images was found to be more effective than optical correlation as a geological mapping instrument when considered in the light of ground truth data. The digital enhancement algorithm consists of a mean square error analysis which preserves the edge structure in the SAR imagery and decreases the noise content. Additionally, digital correlations allowed for faster computer processing of the imagery.

Frost, V. S.↗

Thermal Characterization of Defects in Aircraft Structures Via Spatially Controlled Heat Application

Recent advances in thermal imaging technology have spawned a number of new thermal NDE techniques that provide quantitative information about flaws in aircraft structures. Thermography has a number of advantages as an inspection technique. It is a totally noncontacting, nondestructive, imaging technology capable of inspecting a large area in a matter of a few seconds. The development of fast, inexpensive image processors have aided in the attractiveness of thermography as an NDE technique. These image processors have increased the signal to noise ratio of thermography and facilitated significant advances in post-processing. The resulting digital images enable archival records for comparison with later inspections thus providing a means of monitoring the evolution of damage in a particular structure. The National Aeronautics and Space Administration's Langley Research Center has developed a thermal NDE technique designed to image a number of potential flaws in aircraft structures. The technique involves injecting a small, spatially controlled heat flux into the outer surface of an aircraft. Images of fatigue cracking, bond integrity and material loss due to corrosion are generated from measurements of the induced surface temperature variations. This paper will present a discussion of the development of the thermal imaging system as well as the techniques used to analyze the resulting thermal images. Spatial tailoring of the heat coupled with the analysis techniques represent a significant improvement in the delectability of flaws over conventional thermal imaging. Results of laboratory experiments on fabricated crack, disbond and material loss samples will be presented to demonstrate the capabilities of the technique. An integral part of the development of this technology is the use of analytic and computational modeling. The experimental results will be compared with these models to demonstrate the utility of such an approach.

Cramer, K. Elliott↗

Image-based model of the spectrin cytoskeleton for red blood cell simulation

We simulate deformable red blood cells in the microcirculation using the immersed boundary method with a cytoskeletal model that incorporates structural details revealed by tomographic images. The elasticity of red blood cells is known to be supplied by both their lipid bilayer membranes, which resist bending and local changes in area, and their cytoskeletons, which resist in-plane shear. The cytoskeleton consists of spectrin tetramers that are tethered to the lipid bilayer by ankyrin and by actin-based junctional complexes. We model the cytoskeleton as a random geometric graph, with nodes corresponding to junctional complexes and with edges corresponding to spectrin tetramers such that the edge lengths are given by the end-to-end distances between nodes. The statistical properties of this graph are based on distributions gathered from three-dimensional tomographic images of the cytoskeleton by a segmentation algorithm. We show that the elastic response of our model cytoskeleton, in which the spectrin polymers are treated as entropic springs, is in good agreement with the experimentally measured shear modulus. By simulating red blood cells in flow with the immersed boundary method, we compare this discrete cytoskeletal model to an existing continuum model and predict the extent to which dynamic spectrin network connectivity can protect against failure in the case of a red cell subjected to an applied strain. As a result, the methods presented here could form the basis of disease- and patient-specific computational studies of hereditary diseases affecting the red cell cytoskeleton.

59 BASIC BIOLOGICAL SCIENCES↗

Fast Atomic-Scale Chemical Imaging of Crystalline Materials and Dynamic Phase Transformations

Chemical imaging at the atomic-scale provides a useful real-space approach to chemically investigate solid crystal structures, and has been recently demonstrated in aberration corrected scanning transmission electron microscopy (STEM). Atomic-scale chemical imaging by STEM using energy-dispersive X-ray spectroscopy (EDS) offers easy data interpretation with a one-to-one correspondence between image and structure but has a severe shortcoming due to the poor efficiency of X-ray generation and collection. As a result, it requires a long acquisition time of typical > few 100 seconds, limiting its potential applications. Here we describe the development of an atomic-scale STEM EDS chemical imaging technique that cuts the acquisition time to one or a few seconds, efficiently reducing the acquisition time by more than 100 times. This method was demonstrated using LaAlO 3 (LAO) as a model crystal. Applying this method to the study of phase transformation induced by electron-beam radiation in a layered lithium transition-metal (TM) oxide, i.e., Li[Li 0.2 Ni 0.2 Mn 0.6 ]O 2 (LNMO), a cathode materials for lithium-ion batteries, we obtained a time-series of the atomic-scale chemical imaging, showing the transformation progressing by preferably jumping of Ni atoms from the TM layers into the Li-layers. The new capability offers an opportunity for temporal, atomic-scale chemical mapping of crystal structures for the investigation of materials susceptible to electron irradiation as well as phase transformation and dynamics at the atomic-scale.

36 MATERIALS SCIENCE↗

MOLECULAR GAS AND THE HOST-GALAXY SYSTEM OF THE z {approx} 0.3 QSO PG 1700+518

The detection of CO(1{yields}0) emission in the massive (i.e., M {sub H} {approx} -26.13 mag), z {approx} 0.3 host-galaxy system of the broad absorption line quasi-stellar object (QSO) PG1700+518 is reported. The host system has a CO luminosity of L'{sub CO} {approx} 1.4 x 10{sup 10} K km s{sup -1} pc{sup 2}, and thus a star-forming molecular gas mass of M(H{sub 2}) {approx} 6 x 10{sup 10} M {sub sun} (adopting an {alpha} = 4 M {sub sun} [K km s{sup -1} pc{sup 2}]{sup -1}), making it one of the most molecular gas-rich Palomar-Green QSO hosts observed to date. New Hubble Space Telescope WFPC2 direct and NICMOS coronagraphic images show the highest resolution view yet of the host and companion. The new NICMOS image reveals the underlying, apparently tidally disrupted structure seen previously from high-resolution ground-based optical imaging. Light from the host galaxy is overwhelmed by the central point source in the WFPC2 images. The companion galaxy is well resolved in both data sets, and the WFPC2 provides for the first time a clear picture of the optically visible ring structure. The CO redshift is within the range of redshifts derived from optical QSO emission lines, thus the observed CO is associated with the QSO host. However, it cannot be ruled out that the companion has at least {approx}10{sup 10} M {sub sun} of molecular gas. Finally, if the far-infrared luminosity, which is 1/5 of the bolometric luminosity, is the luminosity of the starburst population, the star formation rate is estimated to be {approx}210 M {sub sun} yr{sup -1}. There is thus sufficient molecular gas in the QSO host galaxy to fuel both star formation and QSO activity for another {approx}10{sup 8} yr. We speculate that we may be witnessing the fueling event in progress that resulted from a collision between the QSO host and the companion galaxy, and that there is an accompanying expulsion of material along our line of sight in the form of broad absorption line gas.

79 ASTRONOMY AND ASTROPHYSICS↗

A Simple Method for Improving the Spatial Resolution in Infrared Laser Ablation Mass Spectrometry Imaging

In mass spectrometry imaging of tissues, the size of structures that can be distinguished is determined by the spatial resolution of the imaging technique. Here, the spatial resolution of IR laser ablation is markedly improved by increasing the distance between the laser and the focusing lens. As the distance between the laser and the lens is increased from 1 to 18 m, the ablation spot size decreases from 440 to 44 μm. This way, only the collimated center of the divergent laser beam is directed on the focusing lens, which results in better focusing of the beam. Part of the laser energy is lost at longer distance, but this is compensated by focusing of the radiation to a smaller area on the sample surface. The long distance can also be achieved by a set of mirrors, between which the radiation travels before it is directed to the focusing lens and the sample. This method for improving the spatial resolution can be utilized in mass spectrometry imaging of tissues by techniques that utilize IR laser ablation, such as laser ablation electrospray ionization, laser ablation atmospheric pressure photoionization, and matrix-assisted laser desorption electrospray ionization. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The detection of urban expansion from Landsat imagery

Two methodologies for detecting and mapping land cover changes in and around growing urban regions are being studied at Jet Propulsion Laboratory. Both approaches, primarily based on digital image processing techniques, have been developed to supplement data stored in an Image Based Information System (IBIS). The structure of this information system enables the depiction of land cover changes in image format concurrently with statistical reports in tabular form. To date the expansion of two urban areas, Houston, Texas and Orlando, Florida, has been monitored.

Friedman, S. Z.↗

Geophysical remote sensing

The types of remote sensing images which have applications in geophysical studies are reviewed. Features of the Shuttle Imaging Radar, a synthetic aperture radar, are described and a sample image is provided to illustrate the capabilities for mapping large-scale geological structure. A combined Landsat-Seasat image is shown to yield data on crustal composition. Sea surface topographic features that result from gravitational effects are demonstrated to be amenable to characterization with another Seasat instrument, a radar altimeter. Magsat data allow identification of magnetic perturbations produced by crustal magnetization. Finally, auroral imagery gathered with the Atmospheric Dynamics Explorer are presented which show that the effects of particles bombarding the atmosphere can be detected at UV wavelengths.

Mcpherron, Robert L.↗

Instantaneous Three-Dimensional Temperature Measurements via Ultrafast Laser Spectroscopy with Structured Light

Detonations and flames are characterized by three-dimensional (3D) temperature fields, yet state-of- the-art temperature measurement techniques yield information at a point or along a line. The goal of the research documented here was to combine ultrafast laser spectroscopy and structured illumination to deliver an unprecedented measurement capability—three-dimensional, instantaneous temperature measurements in a gas-phase volume. To achieve this objective, different parts of the proposed technique were developed and tested independently. Structured illumination was used to image particulate matter (soot) in a turbulent flame at multiple planes using a single laser pulse and a single camera. Emission spectroscopy with structured detection was demonstrated for emission- based measurements of explosives with enhance dimensionality. Finally, an instrument for multi- planar laser-based temperature measurement technique was developed. Structured illumination techniques will continue to be developed for multi-dimensional and multi-parameter measurements. These new measurement capabilities will be important for heat transfer and fluid dynamic research areas.

42 ENGINEERING↗

Refine your search to explore more results.