Search NASA⌕ Search

SEARCH · Search NASA

Results for “study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

An exploration of benchtop X–ray emission spectroscopy for precise characterization of the sulfur redox state in cementitious materials

The evolution of sulfur chemistry in cements is best known in the bailiwick of failure mechanisms via sulfate attack but is equally important for its contributions to the reduction capacity of cementitious materials often used for immobilizing nuclear waste streams destined for long-term storage, e.g., cementitious waste forms (CWF). The total reduction capacity of CWFs, encompassing contributions from both S and Fe reductants, and its implications toward radionuclide immobilization is most often studied by destructive wet chemistry methods requiring acid digestion in the presence of Ce(IV) and subsequent titration and colorimetric interpretation. Here, we investigate a similarly analytical but nondestructive alternative, benchtop high resolution wavelength-dispersive x-ray fluorescence spectroscopy, most commonly known as x-ray emission spectroscopy (XES), for probing the bulk sulfur oxidation state distribution. We present here an initial investigation of S XES, including an improved experimental protocol for lab XES of inhomogeneous samples, both as a complement to the Ce(IV) test and for new scientific opportunities that it enables for observing changes in sulfur chemistry. We discuss future improvements and opportunities, including: (1) the practical challenges associated with coordinating XES and Ce(IV) liquid extraction for a more comprehensive perspective on reduction capacity and for a high-precision evaluation of uncertainties in the Ce(IV) test; and (2) new opportunities, due to the nondestructive nature of XES, for controlled evolution studies aimed at elucidating specific chemical responses of CWF’s exposed to invasive gas or liquid species or to accelerated aging by radiative dose or thermal treatment.

36 MATERIALS SCIENCE↗

Experimental and theoretical study of core-valence double photoionization of OCS

O 1s, C 1s, and S 2p core-valence double ionization electron spectra of the OCS molecule have been obtained experimentally by a time-of-flight photoelectron-photoelectron coincidence spectroscopy technique. In order to analyze and assign the spectral features observed, we present a protocol for computing core-valence ionization energies of such systems. The protocol is based on a restricted active space multiconfigurational self-consistent field (MCSCF) methodology with a freeze-relax procedure to guarantee a correct core-valence state root index without variational collapse. Corrections for extended dynamical correlation and core-core correlation, respectively, are made by multiconfigurational perturbation theory and by uncontracted basis set Moeller-Plesset theory. Envisioning applications to larger molecules, a spin-restricted open-shell density functional method is also applied for the lowest core-valence energies. Furthermore, cross sections through a scheme for computing multiatom Auger transitions generating core-valence holes are presented. We find that the procedure outlined is capable of deriving the energy onset of core-valence ionization within a fraction of an eV and that assignments can be made of the most salient spectral features.

74 ATOMIC AND MOLECULAR PHYSICS↗

Building America Case Study: Low-Cost Evaluation of Energy Savings at the Community Scale, Fresno, California (Fact Sheet)

A new construction pilot community was constructed by builder-partner Wathen-Castanos Hybrid Homes (WCHH) based on a single occupied test house that was designed to achieve greater than 30% energy savings with respect to the House Simulation Protocols (Hendron, Robert; Engebrecht, Cheryn (2010). Building America House Simulation Protocols. Golden, CO: National Renewable Energy Laboratory.). Builders face several key problems when implementing a whole-house systems integrated measures package (SIMP) from a single test house into multiple houses. Although a technical solution already may have been evaluated and validated in an individual test house, the potential exists for constructability failures at the community scale. This report addresses factors of implementation and scalability at the community scale and proposes methodologies by which community-scale energy evaluations can be performed based on results at the occupied test house level. Research focused on the builder and trade implementation of a SIMP and the actual utility usage in the houses at the community scale of production. Five occupants participated in this community-scale research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. Verification with measured data is an important component in predictive energy modeling. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Monte Carlo simulations of the dose from imaging with GE eXplore 120 micro-CT using GATE

Purpose: Small animals are increasingly used as translational models in preclinical imaging studies involving microCT, during which the subjects can be exposed to large amounts of radiation. While the radiation levels are generally sublethal, studies have shown that low-level radiation can change physiological parameters in mice. In order to rule out any influence of radiation on the outcome of such experiments, or resulting deterministic effects in the subjects, the levels of radiation involved need to be addressed. The aim of this study was to investigate the radiation dose delivered by the GE eXplore 120 microCT non-invasively using Monte Carlo simulations in GATE and to compare results to previously obtained experimental values. Methods: Tungsten X-ray spectra were simulated at 70, 80, and 97 kVp using an analytical tool and their half-value layers were simulated for spectra validation against experimentally measured values of the physical X-ray tube. A Monte Carlo model of the microCT system was set up and four protocols that are regularly applied to live animal scanning were implemented. The computed tomography dose index (CTDI) inside a PMMA phantom was derived and multiple field of view acquisitions were simulated using the PMMA phantom, a representative mouse and rat. Results: Simulated half-value layers agreed with experimentally obtained results within a 7% error window. The CTDI ranged from 20 to 56 mGy and closely matched experimental values. Derived organ doses in mice reached 459 mGy in bones and up to 200 mGy in soft tissue organs using the highest energy protocol. Dose levels in rats were lower due to the increased mass of the animal compared to mice. The uncertainty of all dose simulations was below 14%. Conclusions: Monte Carlo simulations proved a valuable tool to investigate the 3D dose distribution in animals from microCT. Small animals, especially mice (due to their small volume), receive large amounts of radiation from the GE eXplore 120 microCT, which might alter physiological parameters in a longitudinal study setup.

60 APPLIED LIFE SCIENCES↗

Distributed Ledger Technology Preliminary Performance Assessment for Applications in Utilities Operational Technology

This paper provides descriptions of the key components of different distributed ledger technology platforms. Distributed ledger technology (DLT) allows for distribution of databases among different organizations and devices. The platforms use cryptographically linked “blocks” to store and verify transactional information between these organizations. DLT increases data security, data integrity, trust among its participants. Different organizations are looking to deploy this distributed and decentralized approach to avoid the single-point-of-failure vulnerabilities associated with centralized data repositories. In this study we examine twelve different DLT platforms. There is agreement within the community that of all the platforms considered here, Hyperledger and Ethereum are the most mature when it comes to privacy and permissions. These DLT platforms are being used for applications such as transactive energy, health care, and the food and goods supply chain. However, further development is required to realize the full promise of DLT. Our assessment includes a general description of each DLT and its key characteristics. Such characteristics include consensus protocol and cryptography used, public vs. private, and permissioned or permissionless. The selection and implementation of a DLT architecture depends heavily on the use case and performance requirements. During this research we found key parameters to measure performance and existing tools for assessment. Four different parameters were identified 1) consensus, 2) throughput, 3) latency, and 4) scalability. The architectures of Hyperledger Caliper and Blockbench are described as different performance assessment frameworks. From this preliminary study it is evident that there are dissimilarities on the performance assessments methods developers and users are characterizing DLT architectures. The purpose of this paper is to identify key parameters to test performance, tools that are being used and provide information on results from previous studies.

97 MATHEMATICS AND COMPUTING↗

Multilayer Electrodes with Metalized Polymer Current Collector for High-Energy Lithium-Ion Batteries with Extreme-Fast-Charging Capability

The pursuit of batteries capable of extreme fast charging (XFC), that also satisfy high energy and safety criteria, poses a significant challenge to current lithium-ion battery technologies. Additionally, the increasing demand for aluminum (Al) and copper (Cu) in electrification, and vehicle light weighting is driving these metals towards near-critical status in the medium term. This study introduced metalized polymer films by depositing an Al or Cu thin layer onto two sides of a polyethylene terephthalate (PET) film – named mPET/Al and mPET/Cu, as lightweight, cost-effective alternatives to traditional metal current collectors in LIBs. We have utilized current collectors that significantly reduce weight (by 73%), thickness (by 33%), and cost (by 85%) compared to traditional metal foil counterparts. We conducted an extensive evaluation of their mechanical and electrical properties, including in-plane and through-plane resistivities, affirming their suitability for the roll-to-roll battery manufacturing process. Additionally, a novel XFC testing protocol was employed to thoroughly assess the cells' (both half and full-cell) performance across various C-rates and under long-term tests. These advancements have the potential to enhance energy density to 280 Wh/kg at the electrode level under 10-minute charging at 6C. Through testing, including a novel XFC protocol across various C-rates and long-term cycling (up to 1000 cycles) in different cell configurations, we have demonstrated the superior performance of these metalized polymer films. Notably, mPET/Cu and mPET/Al foils exhibited comparable capacities to conventional cells under XFC, with the mPET cells showing a 27% improvement in energy density at 6C and maintaining significant energy density after 1000 cycles. This study underscored the potential of mPET foils to revolutionize the roll-to-roll battery manufacturing process and significantly advance the performance metrics of LIBs in EV applications. Moreover, our results suggest that there is potential to enhance the performance of mPET foils, especially mPET/Al, by optimizing the manufacturing process to achieve higher conductivity.

99 GENERAL AND MISCELLANEOUS↗

A study of degradation mechanisms in PVDF-based photovoltaic backsheets

Abstract Commercial backsheets based on polyvinylidene fluoride (PVDF) can experience premature field failures in the form of outer layer cracking. This work seeks to provide a better understanding of the changes in material properties that lead to crack formation and find appropriate accelerated tests to replicate them. The PVDF-based backsheet outer layer can have a different structure and composition, and is often blended with a poly(methyl methacrylate) (PMMA) polymer. We observed depletion of PMMA upon aging with sequential (MAST) and combined (C-AST) accelerated stress testing. In field-aged samples from Arizona and India, where PVDF crystallizes in its predominant α-phase, the degree of crystallinity greatly increased. MAST and C-AST protocols were, to some extent, able to replicate the increase in crystallinity seen in PVDF after ~ 7 years in the field, but no single-stress test condition (UV, damp heat, thermal cycling) resulted in significant changes in the material properties. The MAST regimen used here was too extreme to produce realistic degradation, but the test was useful in discovering weaknesses of the particular PVDF-based outer layer structure studied. No excessive β-phase formation was observed after aging with any test condition; however, the presence of β-phase was identified locally by Fourier transform infrared spectroscopy (FTIR). We conclude that both MAST and C-AST are relevant tests for screening outdoor failure mechanisms in PVDF backsheets, as they were successful in producing material degradation that led to cracking.

14 SOLAR ENERGY↗

Deep learning and radiomics: the utility of Google TensorFlow™ Inception in classifying clear cell renal cell carcinoma and oncocytoma on multiphasic CT

Purpose: Currently, all solid enhancing renal masses without microscopic fat are considered malignant until proven otherwise and there is substantial overlap in the imaging findings of benign and malignant renal masses, particularly between clear cell RCC (ccRCC) and benign oncocytoma (ONC). Radiomics has attracted increased attention for its utility in pre-operative work-up on routine clinical images. Radiomics based approaches have converted medical images into mineable data and identified prognostic imaging signatures that machine learning algorithms can use to construct predictive models by learning the decision boundaries of the underlying data distribution. The TensorFlow™ framework from Google is a state-of-the-art open-source software library that can be used for training deep learning neural networks for performing machine learning tasks. The purpose of this study was to investigate the diagnostic value and feasibility of a deep learning-based renal lesion classifier using open-source Google TensorFlow™ Inception in differentiating ccRCC from ONC on routine four-phase MDCT in patients with pathologically confirmed renal masses. Methods: With institutional review board approval for this 1996 Health Insurance Portability and Accountability Act compliant retrospective study and a waiver of informed consent, we queried our institution’s pathology, clinical, and radiology databases for histologically proven cases of ccRCC and ONC obtained between January 2000 and January 2016 scanned with a an intravenous contrast-enhanced four-phase renal mass protocol (unenhanced (UN), corticomedullary (CM), nephrographic (NP), and excretory (EX) phases). To extract features to be used for the machine learning model, the entire renal mass was contoured in the axial plane in each of the four phases, resulting in a 3D volume of interest (VOI) representative of the entire renal mass. We investigated thirteen different approaches to convert the acquired VOI data into a set of images that adequately represented each tumor which was used to train the final layer of the neural network model. Training was performed over 4000 iterations. In each iteration, 90% of the data were designated as training data and the remaining 10% served as validation data and a leave-one-out cross-validation scheme was implemented. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive (NPV) values, and CIs were calculated for the classification of the thirteen processing modes. Results: We analyzed 179 consecutive patients with 179 lesions (128 ccRCC and 51 ONC). The ccRCC cohort had a mean size of 3.8 cm (range 0.8–14.6 cm) and the ONC cohort had a mean lesion size of 3.9 cm (range 1.0–13.1 cm). The highest specificity and PPV (52.9% and 80.3%, respectively) were achieved in the EX phase when we analyzed the single mid-slice of the tumor in the axial, coronal and sagittal plane, and when we increased the number of mid-slices of the tumor to three, with an accuracy of 75.4%, which also increased the sensitivity to 88.3% and the PPV to 79.6%. Using the entire tumor volume also showed that classification performance was best in the EX phase with an accuracy of 74.4%, a sensitivity of 85.8% and a PPV of 80.1%. When the entire tumor volume, plus mid-slices from all phases and all planes presented as tiled images, were submitted to the final layer of the neural network we achieved a PPV of 82.5%. Conclusions: The best classification result was obtained in the EX phase among the thirteen classification methods tested. Our proof of concept study is the first step towards understanding the utility of machine learning in the differentiation of ccRCC from ONC on routine CT images. We hope this could lead to future investigation into the development of a multivariate machine learning model which may augment our ability to accurately predict renal lesion histology on imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A random unitary circuit model for black hole evaporation

Inspired by the Hayden-Preskill protocol for black hole evaporation, we consider the dynamics of a quantum many-body qudit system coupled to an external environment, where the time evolution is driven by the continuous limit of certain 2-local random unitary circuits. We study both cases where the unitaries are chosen with and without a conserved U(1) charge and focus on two aspects of the dynamics. First, we study analytically and numerically the growth of the entanglement entropy of the system, showing that two different time scales appear: one is intrinsic to the internal dynamics (the scrambling time), while the other depends on the system-environment coupling. In the presence of a U(1) conserved charge, we show that the entanglement follows a Page-like behavior in time: it begins to decrease in the middle stage of the “evaporation”, and decreases monotonically afterwards. Second, we study the time needed to retrieve information initially injected in the system from measurements on the environment qudits. Based on explicit numerical computations, we characterize such time both when the retriever has control over the initial configuration or not, showing that different scales appear in the two cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Children and youth's biopsychosocial wellbeing in the context of energy resource activities

Background: Children and youth emerge as key populations that are impacted by energy resource activities, in part because of their developmental vulnerabilities, as well as the compounding effects of energy systems on their families, communities, and physical environments. While there is a larger literature focused on fossil fuel emissions and children, the impacts of many aspects of energy systems on children and youth remain under examined and scattered throughout the health, social science, and environmental science literatures. Objectives: This systematic interdisciplinary review examines the biological, psychosocial, and economic impacts of energy systems identified through social science research – specifically focused on household and industrial extraction and emissions – on children and youth functioning. Methods: A critical interpretive search of interdisciplinary and international social sciences literature was conducted using an adaptive protocol focusing on the biopsychosocial and economic impacts of energy systems on children and youth. The initial results were complemented with a purposeful search to extend the breadth and depth of the final collection of articles. Discussion: Although relatively few studies have specifically focused on children and youth in this context, the majority of this research uncovers a range of negative health impacts that are directly and indirectly related to the development and ongoing operations of natural resource production, particularly oil and gas, coal, and nuclear energy. Psychosocial and cultural effects, however, remain largely unexamined and provide a rich avenue for further research. Conclusions: This synthesis identifies an array of adverse biopsychosocial health outcomes on children and youth of energy resource extraction and emissions, and identifies gaps that will drive future research in this area. - Highlights: • Children and youth are vulnerable to the effects of energy extraction and emissions. • This review details biopsychosocial impacts of these activities on young people. • Psychosocial impacts of energy extraction and emissions are largely unexamined.

02 PETROLEUM↗

Representativeness and repeatability of microenvironmental personal and head exposures to radio-frequency electromagnetic fields

Highlights: • First time assessment of head exposure to RF-EMF in uncontrolled environments, in 15 microenvironments in Melbourne, Australia. • We show that our measurement protocol is repeatable over time. • We show that the paths selected in our protocol are representative for the larger areas in which they are defined. • Exposure to RF-EMF is higher in more dense urban areas than in less populated suburban areas in the outskirts of the city. The aims of this study were to: i) investigate the repeatability and representativeness of personal radio frequency-electromagnetic fields (RF-EMFs) exposure measurements, across different microenvironments, ii) perform simultaneous evaluations of personal RF-EMF exposures for the whole body and the head, iii) validate the data obtained with a head-worn personal distributed exposimeter (PDE) against those obtained with an on-body worn personal exposimeter (PEM). Data on personal and head RF-EMF exposures were collected by performing measurements across 15 microenvironments in Melbourne, Australia. A body-worn PEM and a head-worn PDE were used for measuring body and head exposures, respectively. The summary statistics obtained for total RF-EMF exposure showed a high representativeness (r{sup 2} > 0.66 for two paths in the same area) and a high repeatability over time (r{sup 2} > 0.87 for repetitions of the same path). The median head exposure in the 900 MHz downlink band ranged between 0.06 V/m and 0.31 V/m. The results obtained during simultaneous measurements using the two devices showed high correlations (0.42 < r{sup 2} < 0.94). The highest mean total RF-EMF exposure was measured in Melbourne's central business district (0.89 V/m), whereas the lowest mean total exposure was measured in a suburban residential area (0.05 V/m). This study shows that personal RF-EMF microenvironmental measurements in multiple microenvironments have high representativeness and repeatability over time. The personal RF-EMF exposure levels (i.e. body and head exposures) demonstrated moderate to high correlations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

The effect of rapid and sustained decompression on barotrauma in juvenile brook lamprey and Pacific lamprey: implications for passage at hydroelectric facilities

Fish passing downstream through hydroelectric facilities may pass through hydroturbines where they experience a rapid decrease in barometric pressure as they pass by turbine blades, which can lead to barotraumas including swim bladder rupture, exopthalmia, emboli, and hemorrhaging. In juvenile Chinook salmon, the main mechanism for injury is thought to be expansion of existing gases (particularly those present in the swim bladder) and the rupture of the swim bladder ultimately leading to exopthalmia, emboli and hemorrhaging. In fish that lack a swim bladder, such as lamprey, the rate and severity of barotraumas due to rapid decompression may be reduced however; this has yet to be extensively studied. Another mechanism for barotrauma can be gases coming out of solution and the rate of this occurrence may vary among species. In this study, juvenile brook and Pacific lamprey acclimated to 146.2 kPa (equivalent to a depth of 4.6 m) were subjected to rapid (<1 sec; brook lamprey only) or sustained decompression (17 minutes) to a very low pressure (13.8 kPa) using a protocol previously applied to juvenile Chinook salmon. No mortality or evidence of barotraumas, as indicated by the presence of hemorrhages, emboli or exopthalmia, were observed during rapid or sustained decompression, nor following recovery for up to 120 h following sustained decompression. In contrast, mortality or injury would be expected for 97.5% of juvenile Chinook salmon exposed to a similar rapid decompression to these very low pressures. Additionally, juvenile Chinook salmon experiencing sustained decompression died within 7 minutes, accompanied by emboli in the fins and gills and hemorrhaging in the tissues. Thus, juvenile lamprey may not be susceptible to barotraumas associated with hydroturbine passage to the same degree as juvenile salmonids, and management of these species should be tailored to their specific morphological and physiological characteristics.

13 HYDRO ENERGY↗

Real-Time Tumor Tracking in the Lung Using an Electromagnetic Tracking System

Purpose: To describe the first use of the commercially available Calypso 4D Localization System in the lung. Methods and Materials: Under an institutional review board-approved protocol and an investigational device exemption from the US Food and Drug Administration, the Calypso system was used with nonclinical methods to acquire real-time 4-dimensional lung tumor tracks for 7 lung cancer patients. The aims of the study were to investigate (1) the potential for bronchoscopic implantation; (2) the stability of smooth-surface beacon transponders (transponders) after implantation; and (3) the ability to acquire tracking information within the lung. Electromagnetic tracking was not used for any clinical decision making and could only be performed before any radiation delivery in a research setting. All motion tracks for each patient were reviewed, and values of the average displacement, amplitude of motion, period, and associated correlation to a sinusoidal model (R{sup 2}) were tabulated for all 42 tracks. Results: For all 7 patients at least 1 transponder was successfully implanted. To assist in securing the transponder at the tumor site, it was necessary to implant a secondary fiducial for most transponders owing to the transponder's smooth surface. For 3 patients, insertion into the lung proved difficult, with only 1 transponder remaining fixed during implantation. One patient developed a pneumothorax after implantation of the secondary fiducial. Once implanted, 13 of 14 transponders remained stable within the lung and were successfully tracked with the tracking system. Conclusions: Our initial experience with electromagnetic guidance within the lung demonstrates that transponder implantation and tracking is achievable though not clinically available. This research investigation proved that lung tumor motion exhibits large variations from fraction to fraction within a single patient and that improvements to both transponder and tracking system are still necessary to create a clinical daily-use system to assist with actual lung radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preoperative Chemoradiation Therapy With Capecitabine/Oxaliplatin and Cetuximab in Rectal Cancer: Long-Term Results of a Prospective Phase 1/2 Study

Purpose: We have previously shown that the addition of cetuximab to chemoradiation therapy failed to improve complete response rates (pCR) in rectal cancer. Here we report the long-term results of the cetuximab added to preoperative radiation therapy with capecitabine and oxaliplatin (CET-CAPOX-RT) phase 1/2 study that evaluated preoperative chemoradiation with cetuximab, capecitabine, and oxaliplatin in patients with rectal cancer. Methods and Materials: The median follow-up was 63 months (range, 5-73 months). Sixty patients were enrolled; 3 patients were excluded due to protocol violation, and 4 died before surgery. Total mesorectal excision was performed in 53 patients, in 85% (n=45) with curative intention (M0-status). Secondary end points including overall survival (OS) disease-free survival (DFS) and cancer-specific survival (CSS) were calculated. The prognostic value of KRAS mutation status was also assessed. Results: Histopathological examination confirmed ypUICC stages 0 (n=4; pCR), I (n=17), II (n=10), III (n=14), and IV (n=8). For patients who underwent surgery (n=53), OS at 1, 3, and 5 years was 88.7%, 83%, and 75.5%, respectively, whereas CSS rates were 94.1%, 88.1%, and 78.1%, respectively. In the 45 patients who were treated with curative intent (M0), the OS rates at 1, 3, and 5 years were 91.1%, 88.9%, and 86.7%, respectively; whereas CSS rates were 97.6%, 95.2%, and 90.3%, respectively; and DFS rates were 90.7%, 88.3%, and 88.3%, respectively. We did not find any locoregional failure in patients with M0-status (n=45). Chronic toxicity was rare. KRAS mutations, as detected in 33.3%, showed no correlation with the clinicopathological parameters nor significance for either OS (P=.112), CSS (P=.264), or DFS (P=.565). Conclusions: Taken together, chemoradiation therapy combined with cetuximab is safe, feasible, and offers excellent survival rates. KRAS mutation status was not a predictive factor. Importantly, lack of improvement in pCR rate did not translate to poor survival in our clinical trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Polythiophene thin films by surface-initiated polymerization: Mechanistic and structural studies

The ability to control nanoscale morphology and molecular organization in organic semiconducting polymer thin films is an important prerequisite for enhancing the efficiency of organic thin-film devices including organic light-emitting and photovoltaic devices. The current “top-down” paradigm for making such devices is based on utilizing solution-based processing (e.g., spin-casting) of soluble semiconducting polymers. This approach typically provides only modest control over nanoscale molecular organization and polymer chain alignment. A promising alternative to using solutions of presynthesized semiconducting polymers pursues instead a “bottom-up” approach to prepare surface-grafted semiconducting polymer thin films by surface-initiated polymerization of small-molecule monomers. Herein, we describe the development of an efficient method to prepare polythiophene thin films utilizing surface-initiated Kumada catalyst transfer polymerization. In this study, we provided evidence that the surface-initiated polymerization occurs by the highly robust controlled (quasi-“living”) chain-growth mechanism. Further optimization of this method enabled reliable preparation of polythiophene thin films with thickness up to 100 nm. Extensive structural studies of the resulting thin films using X-ray and neutron scattering methods as well as ultraviolet photoemission spectroscopy revealed detailed information on molecular organization and the bulk morphology of the films, and enabled further optimization of the polymerization protocol. One of the remarkable findings was that surface-initiated polymerization delivers polymer thin films showing complex molecular organization, where polythiophene chains assemble into lateral crystalline domains of about 3.2 nm size, with individual polymer chains folded to form in-plane aligned and densely packed oligomeric segments (7-8 thiophene units per each segment) within each domain. Achieving such a complex mesoscale organization is virtually impossible with traditional methods relying on solution processing of presynthesized polymers. Another significant advantage of surface-confined polymer thin films is their remarkable stability toward organic solvents and other processing conditions. In addition to controlled bulk morphology, uniform molecular organization, and stability, a unique feature of the surface-initiated polymerization is that it can be used for the preparation of large-area uniformly nanopatterned polymer thin films. Lastly, this was demonstrated using a combination of particle lithography and surface-initiated polymerization. In general, surface-initiated polymerization is not limited to polythiophene but can be also expanded toward other classes of semiconducting polymers and copolymers.

36 MATERIALS SCIENCE↗

Practical Hamiltonian learning with unitary dynamics and Gibbs states

We study the problem of learning the parameters for the Hamiltonian of a quantum many-body system, given limited access to the system. In this work, we build upon recent approaches to Hamiltonian learning via derivative estimation. We propose a protocol that improves the scaling dependence of prior works, particularly with respect to parameters relating to the structure of the Hamiltonian (e.g., its locality k). Furthermore, by deriving exact bounds on the performance of our protocol, we are able to provide a precise numerical prescription for theoretically optimal settings of hyperparameters in our learning protocol, such as the maximum evolution time (when learning with unitary dynamics) or minimum temperature (when learning with Gibbs states). Thanks to these improvements, our protocol has practical scaling for large problems: we demonstrate this with a numerical simulation of our protocol on an 80-qubit system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Trustworthiness of detectors in quantum key distribution with untrusted detectors

Measurement-device-independent quantum key distribution (MDI-QKD) protocol has been demonstrated as a viable solution to detector side-channel attacks. One of the main advantages of MDI-QKD is that the security can be proved without making any assumptions about how the measurement device works. The price to pay is the relatively low secure key rate comparing with conventional quantum key distribution (QKD), such as the decoy-state BB84 protocol. Recently a new QKD protocol, aiming at bridging the strong security of MDI-QKD with the high e ciency of conventional QKD, has been proposed. In this protocol, the legitimate receiver employs a trusted linear optics network to encode information on photons received from an insecure quantum channel, and then performs a Bell state measurement (BSM) using untrusted detectors. One crucial assumption made in most of these studies is that the untrusted BSM located inside the receiver's laboratory cannot send any unwanted information to the outside. Here in this paper, we show that if the BSM is completely untrusted, a simple scheme would allow the BSM to send information to the outside. Combined with Trojan horse attacks, this scheme could allow Eve to gain information of the quantum key without being detected. Ultimately, to prevent the above attack, either countermeasures to Trojan horse attacks or some trustworthiness to the "untrusted" BSM device is required.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Refine your search to explore more results.