Search NASA⌕ Search

SEARCH · Search NASA

Results for “study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Role of Equilibrium Fluctuations in Light-Induced Order

Engineering novel states of matter with light is at the forefront of materials research. An intensely studied direction is to realize broken-symmetry phases that are “hidden” under equilibrium conditions but can be unleashed by an ultrashort laser pulse. Despite a plethora of experimental discoveries, the nature of these orders and how they transiently appear remain unclear. To this end, we investigate a nonequilibrium charge density wave (CDW) in rare-earth tritellurides, which is suppressed in equilibrium but emerges after photoexcitation. Using a pump-pump-probe protocol implemented in ultrafast electron diffraction, we demonstrate that the light-induced CDW consists solely of order parameter fluctuations, which bear striking similarities to critical fluctuations in equilibrium despite differences in the length scale. By calculating the dynamics of CDW fluctuations in a nonperturbative model, we further show that the strength of the light-induced order is governed by the amplitude of equilibrium fluctuations. Overall, these findings highlight photoinduced fluctuations as an important ingredient for the emergence of transient orders out of equilibrium. Our results further suggest that materials with strong fluctuations in equilibrium are promising platforms to host hidden orders after laser excitation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-D-12A-06: A Comprehensive Parameter Analysis for Low Dose Cone-Beam CT Reconstruction

Purpose: There is always a parameter in compressive sensing based iterative reconstruction (IR) methods low dose cone-beam CT (CBCT), which controls the weight of regularization relative to data fidelity. A clear understanding of the relationship between image quality and parameter values is important. The purpose of this study is to investigate this subject based on experimental data and a representative advanced IR algorithm using Tight-frame (TF) regularization. Methods: Three data sets of a Catphan phantom acquired at low, regular and high dose levels are used. For each tests, 90 projections covering a 200-degree scan range are used for reconstruction. Three different regions-of-interest (ROIs) of different contrasts are used to calculate contrast-to-noise ratios (CNR) for contrast evaluation. A single point structure is used to measure modulation transfer function (MTF) for spatial-resolution evaluation. Finally, we analyze CNRs and MTFs to study the relationship between image quality and parameter selections. Results: It was found that: 1) there is no universal optimal parameter. The optimal parameter value depends on specific task and dose level. 2) There is a clear trade-off between CNR and resolution. The parameter for the best CNR is always smaller than that for the best resolution. 3) Optimal parameters are also dose-specific. Data acquired under a high dose protocol require less regularization, yielding smaller optimal parameter values. 4) Comparing with conventional FDK images, TF-based CBCT images are better under a certain optimally selected parameters. The advantages are more obvious for low dose data. Conclusion: We have investigated the relationship between image quality and parameter values in the TF-based IR algorithm. Preliminary results indicate optimal parameters are specific to both the task types and dose levels, providing guidance for selecting parameters in advanced IR algorithms. This work is supported in part by NIH (1R01CA154747-01)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strain-concentration for fast, compact photonic modulation and non-volatile memory

A critical figure of merit (FoM) for electro-optic (EO) modulators is the transmission change per voltage, d T / d V . Conventional approaches in wave-guided modulators maximize d T / d V via a high EO coefficient or longer light-material interaction lengths but are ultimately limited by material losses and nonlinearities. Optical and RF resonances improve d T / d V at the cost of spectral non-uniformity, especially for high- Q optical cavity resonances. Here, we introduce an EO modulator based on piezo-strain-concentration of a photonic crystal cavity to address both trade-offs: (i) it eliminates the trade-off between d T / d V and waveguide loss—i.e., enhancement of the resonance tuning efficiency d v c / d V for the fixed EO coefficient, waveguide length, and cavity Q —and (ii) at high DC strains it exhibits a non-volatile (NV) cavity tuning Δ v c ,NV for passive memory and programming of multiple devices into resonance despite fabrication variations. The device is fabricated on a scalable silicon nitride-on-aluminum nitride platform. We measure d v c / d V =177±1MHz/V, corresponding to Δ v c =40±0.32GHz for a voltage spanning ±120V with an energy consumption of δ U /Δ v c =0.17nW/GHz. The modulation bandwidth is flat up to ω BW,3dB /2 π =3.2±0.07MHz for broadband DC-AC and 142±17MHz for resonant operation near a 2.8 GHz mechanical resonance. Optical extinction up to 25 dB is obtained via Fano-type interference. Strain-induced beam-buckling modes are programmable under a “read-write” protocol with a continuous, repeatable tuning range of 5±0.25GHz, allowing for storage and retrieval, which we quantify with mutual information of 2.4 bits and a maximum non-volatile excursion of 8 GHz. Using a full piezo-optical finite-element-model (FEM) we identify key design principles for optimizing strain-based modulators and chart a path towards achieving performance comparable to lithium niobate-based modulators and the study of high strain physics on-chip.

Wen, Y. Henry (ORCID:0009000685423628)↗

Avian community composition in response to high explosive testing operations at Los Alamos National Laboratory in Northern New Mexico

Breeding bird abundance, species richness, evenness, diversity, composition, productivity, and survivorship were determined near a high-explosive detonation site at Los Alamos National Laboratory, New Mexico, USA, during pre-operation (1997-1999) and operation (2000-2014) periods. The operation periods consisted of detonations (<23 kg in yield and <3 per breeding season) in open air (2000-2002), within foam containment (2003-2006) and within steel vessel containment (2007-2014) systems; the latter two were employed to reduce noise and dispersal of high-explosives residues. A total of 2952 bird captures, representing 80 species, was recorded during 18 years of mist net operations using the Monitoring Avian Productivity and Survivorship protocol. Individuals captured were identified to species, aged, sexed, and banded during May through August of each year. There were no significant differences (p > 0.05) in mean avian abundance and species evenness in any of the operation periods as compared with the pre-operation period. Species richness and diversity were significantly higher (p < 0.05) during the vessel containment period (2007-2014) than the pre-operation period. The time period of this study coincided with a wildfire (2000), a bark beetle infestation (2002), and two periods of drought (Nov 1999-Mar 2004 and Dec 2005-Dec 2014) that affected the study area. Furthermore, analysis of aerial photos determined that the average percent canopy cover of mature ponderosa pines (Pinus ponderosa) within 100 feet of mist net sites declined from 12% to 3% between 1991 and 2014 and the percent cover of shrubs slightly increased.

54 ENVIRONMENTAL SCIENCES↗

Phase 3 Trial of Domiciliary Humidification to Mitigate Acute Mucosal Toxicity During Radiation Therapy for Head-and-Neck Cancer: First Report of Trans Tasman Radiation Oncology Group (TROG) 07.03 RadioHUM Study

Purpose: To assess the impact of domicile-based humidification on symptom burden during radiation therapy (RT) for head-and-neck (H and N) cancer. Methods and Materials: From June 2007 through June 2011, 210 patients with H and N cancer receiving RT were randomized to either a control arm or to receive humidification using the Fisher and Paykel Healthcare MR880 humidifier. Humidification commenced on day 1 of RT and continued until Common Terminology Criteria for Adverse Events (CTCAE), version 3.0, clinical mucositis (CMuc) grade ≤1 occurred. Forty-three patients (42%) met a defined benchmark for humidification compliance and contributed to per protocol (PP) analysis. Acute toxicities, hospitalizations, and feeding tube events were recorded prospectively. The McMaster University Head and Neck Radiotherapy Questionnaire (HNRQ) was used for patient-reported outcomes. The primary endpoint was area under the curve (AUC) for CMuc grade ≥2. Results: There were no significant differences in AUC for CMuc ≥2 between the 2 arms. Humidification patients had significantly fewer days in hospital (P=.017). In compliant PP patients, the AUC for CTCAE functional mucositis score (FMuc) ≥2 was significantly reduced (P=.009), and the proportion who never required a feeding tube was significantly greater (P=.04). HNRQ PP analysis estimates also in the direction favoring humidification with less symptom severity, although differences at most time points did not reach significance. Conclusions: TROG 07.03 has provided efficacy signals consistent with a role for humidification in reducing symptom burden from mucositis, but the influence of humidification compliance on the results moderates recommendations regarding its practical utility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase II Trial of Radiosurgery to Magnetic Resonance Spectroscopy-Defined High-Risk Tumor Volumes in Patients With Glioblastoma Multiforme

Purpose: To determine the efficacy of a Gamma Knife stereotactic radiosurgery (SRS) boost to areas of high risk determined by magnetic resonance spectroscopy (MRS) functional imaging in addition to standard radiotherapy for patients with glioblastoma (GBM). Methods and Materials: Thirty-five patients in this prospective Phase II trial underwent surgical resection or biopsy for a GBM followed by SRS directed toward areas of MRS-determined high biological activity within 2 cm of the postoperative enhancing surgical bed. The MRS regions were determined by identifying those voxels within the postoperative T2 magnetic resonance imaging volume that contained an elevated choline/N-acetylaspartate ratio in excess of 2:1. These voxels were marked, digitally fused with the SRS planning magnetic resonance image, targeted with an 8-mm isocenter per voxel, and treated using Radiation Therapy Oncology Group SRS dose guidelines. All patients then received conformal radiotherapy to a total dose of 60 Gy in 2-Gy daily fractions. The primary endpoint was overall survival. Results: The median survival for the entire cohort was 15.8 months. With 75% of recursive partitioning analysis (RPA) Class 3 patients still alive 18 months after treatment, the median survival for RPA Class 3 has not yet been reached. The median survivals for RPA Class 4, 5, and 6 patients were 18.7, 12.5, and 3.9 months, respectively, compared with Radiation Therapy Oncology Group radiotherapy-alone historical control survivals of 11.1, 8.9, and 4.6 months. For the 16 of 35 patients who received concurrent temozolomide in addition to protocol radiotherapeutic treatment, the median survival was 20.8 months, compared with European Organization for Research and Treatment of Cancer historical controls of 14.6 months using radiotherapy and temozolomide. Grade 3/4 toxicities possibly attributable to treatment were 11%. Conclusions: This represents the first prospective trial using selective MRS-targeted functional SRS combined with radiotherapy for patients with GBM. This treatment is feasible, with acceptable toxicity and patient survivals higher than in historical controls. This study can form the basis for a multicenter, randomized trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The development of methods for primary mast cells in vitro and ex vivo: An historical review

Highlights: • Mast cells form a first-line defense of immune system against various challenges. • Over the past few decades, technologies for acquiring mast cells have been continually optimized. • The advantages and applicability of diverse mast cell models evaluated. • It is important to choose a proper cell source for mast cell-related experiments. Mast cells (MCs) are tissue-based stationary effector cells that form the immune system's first-line defense against various challenges. They are developed from the bone marrow-derived progenitors to complete their differentiation and maturation in the tissues where they eventually establish residence. MCs have been implicated in many diseases, such as allergy, parasitic infection, and neoplastic disorders. Immortalized MC lines, such as RBL-2H3, HMC-1, and LAD-2, are useful for investigating the biological functions of MC only to some extents due to the restriction of degranulation evaluation, in vivo injection and other factors. Over the past few decades, technologies for acquiring primarily MCs have been continually optimized, and novel protocols have been proposed. However, no relevant publications have analyzed and summarized these techniques. In this review, the classical approaches for extracting MCs are generalized, and new methods with potential values are introduced. We also evaluate the advantages and applicability of diverse MC models. Since MCs exhibit substantial plasticity and functional diversity due to different origins, it is both necessary and urgent to select a reliable and suitable source of MCs for a particular study.

60 APPLIED LIFE SCIENCES↗

The SYRMEP Beamline of Elettra: Clinical Mammography and Bio-medical Applications

At the SYnchrotron Radiation for MEdical Physics (SYRMEP) beamline of Elettra Synchrotron Light Laboratory in Trieste (Italy), an extensive research program in bio-medical imaging has been developed since 1997. The core program carried out by the SYRMEP collaboration concerns the use of Synchrotron Radiation (SR) for clinical mammography with the aim of improving the diagnostic performance of the conventional technique. The first protocol with patients, started in 2006 has been completed at the end of 2009 and the data analysis is now in progress.Regarding applications different from clinical imaging, synchrotron X-ray computed microtomography (micro-CT) is the most used technique, both in absorption and phase contrast. A new software tool, Pore3D, has been developed to perform a quantitative morphological analysis on the reconstructed slices and to access textural information of the sample under study.

43 PARTICLE ACCELERATORS↗

Purification and SAXS Analysis of the Integrin Linked Kinase, PINCH, Parvin (IPP) Heterotrimeric Complex

The heterotrimeric protein complex containing the integrin linked kinase (ILK), parvin, and PINCH proteins, termed the IPP complex, is an essential component of focal adhesions, where it interacts with many proteins to mediate signaling from integrin adhesion receptors. Here we conduct a biochemical and structural analysis of the minimal IPP complex, comprising full-length human ILK, the LIM1 domain of PINCH1, and the CH2 domain of α-parvin. We provide a detailed purification protocol for IPP and show that the purified IPP complex is stable and monodisperse in solution. Using small-angle X-ray scattering (SAXS), we also conduct the first structural characterization of IPP, which reveals an elongated shape with dimensions 120×60×40 Å. Flexibility analysis using the ensemble optimization method (EOM) is consistent with an IPP complex structure with limited flexibility, raising the possibility that inter-domain interactions exist. However, our studies suggest that the inter-domain linker in ILK is accessible and we detect no inter-domain contacts by gel filtration analysis. This study provides a structural foundation to understand the conformational restraints that govern the IPP complex.

59 BASIC BIOLOGICAL SCIENCES↗

An extrapolation method for strain ranges and hold times in developing the EPP+SMT creep-fatigue design curves for Alloy 617

Experimental and numerical studies in developing the integrated Elastic–Perfectly Plastic (EPP) plus Simplified Model Test (SMT) design methodology, referred to as the EPP+SMT method, continued in FY2022. This report focuses on the methods for extrapolating the EPP+SMT creep-fatigue (CF) design curves at long hold times and low strain ranges. In this study, the available CF failure data on Alloy 617 at 950°C were analyzed to determine a set of CF failure criteria. At very low strain ranges and long hold times, CF failure data are not accessible by experiments because of the extraordinarily long test durations and the inability of the test machines to accurately control these small strain ranges. A CF experimental approach with the concept of block-strain range CF testing protocol was developed. Tests using this protocol were conducted to generate the needed information for calibrating material parameters of the numerical material models. The Time Fraction based method and Dissipated Energy method were used to extrapolate the CF life curves to low strain ranges and long hold times. Based on the new experimental approach and CF life prediction methods, the CF life curves with various hold times were developed for Alloy 617 at 950°C. In addition, an experiment was designed and is being performed to verify the predicted CF curves at 950°C. The extrapolation procedure will be applied at lower temperatures to complete the development of the EPP+SMT CF design curves for Alloy 617 in F2023.

36 MATERIALS SCIENCE↗

A chemical dynamics study on the gas-phase formation of triplet and singlet C 5 H 2 carbenes

Significance Carbenes represent key reactive intermediates in molecular mass growth processes leading to carbonaceous nanostructures in the interstellar medium and in combustion systems. However, due to their short lifetimes and tendency for dimerization, carbenes represent one of the foremost obscured classes of reactive intermediates, with the preparation of carbenes in the gas phase remaining largely elusive. By merging molecular beams with electronic structure and quasi-classical trajectory calculations and exploiting triplet pentadiynylidene (HCCCCCH) and singlet ethynylcyclopropenylidene (c-C 5 H 2 ) carbene as benchmarks, we present a versatile protocol to unravel the dynamics leading to exotic carbenes under single-collision conditions. These elementary mechanisms are of significance to our understanding of the fundamental processes leading to unsaturated organic transients in extreme, hydrocarbon-rich environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Feedback-Based Fault-Tolerant and Health-Adaptive Optimal Charging of Batteries

The key technology barriers that hinder the growth of Electric Vehicles (EVs) are long charging time, the shorter life-time of EV batteries, and battery safety. Specifically, EV charging protocols have significant effects on battery lifetime and safety. If not charged properly, the battery could end up with shorter life, and more importantly, improper charging can cause battery faults leading to catastrophic failures. To overcome these barriers, we propose a closed-loop feedback based approach, that enables real-time optimal fast charging protocol adaptation to battery health and possess active diagnostic capabilities in the sense that, during charging, it detects real-time faults and takes corrective action to mitigate such fault effects. We utilize battery electrical-thermal model, explicit battery capacity and power fade aging models, and thermal fault model to capture battery behavior. In conjunction with the models, we adopt linear quadratic optimal control techniques to realize the feedback-based control algorithm. Simulation studies are presented to illustrate the effectiveness of the proposed scheme.

batteries↗

Phase I Trial of Hypofractionated Intensity-Modulated Radiotherapy With Temozolomide Chemotherapy for Patients With Newly Diagnosed Glioblastoma Multiforme

Purpose: To determine the maximal tolerated biologic dose intensification of radiotherapy using fractional dose escalation with temozolomide (TMZ) chemotherapy in patients with newly diagnosed glioblastoma multiforme. Methods and Materials: Patients with newly diagnosed glioblastoma multiforme after biopsy or resection and with adequate performance status, bone marrow, and organ function were eligible. The patients underwent postoperative intensity-modulated radiotherapy (IMRT) with concurrent and adjuvant TMZ. All patients received a total dose of 60 Gy to the surgical cavity and residual tumor, with a 5-mm margin. IMRT biologic dose intensification was achieved by escalating from 3 Gy/fraction (Level 1) to 6 Gy/fraction (Level 4) in 1-Gy increments. Concurrent TMZ was given at 75 mg/m{sup 2}/d for 28 consecutive days. Adjuvant TMZ was given at 150-200 mg/m{sup 2}/d for 5 days every 28 days. Dose-limiting toxicity was defined as any Common Terminology Criteria for Adverse Events, version 3, Grade 3-4 nonhematologic toxicity, excluding Grade 3 fatigue, nausea, and vomiting. A standard 3+3 Phase I design was used. Results: A total of 16 patients were accrued (12 men and 4 women, median age, 69 years; range, 34-84. The median Karnofsky performance status was 80 (range, 60-90). Of the 16 patients, 3 each were treated at Levels 1 and 2, 4 at Level 3, and 6 at Level 4. All patients received IMRT and concurrent TMZ according to the protocol, except for 1 patient, who received 14 days of concurrent TMZ. The median number of adjuvant TMZ cycles was 7.5 (range, 0-12). The median survival was 16.2 months (range, 3-33). One patient experienced vision loss in the left eye 7 months after IMRT. Four patients underwent repeat surgery for suspected tumor recurrence 6-12 months after IMRT; 3 had radionecrosis. Conclusions: The maximal tolerated IMRT fraction size was not reached in our study. Our results have shown that 60 Gy IMRT delivered in 6-Gy fractions within 2 weeks with concurrent and adjuvant TMZ is tolerable in selected patients with a T{sub 1}-weighted enhancing tumor <6 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Therapy Oncology Group Protocol 02-29: A Phase II Trial of Neoadjuvant Therapy With Concurrent Chemotherapy and Full-Dose Radiation Therapy Followed by Surgical Resection and Consolidative Therapy for Locally Advanced Non-small Cell Carcinoma of the Lung

Purpose: To evaluate mediastinal nodal clearance (MNC) rates after induction chemotherapy and concurrent, full-dose radiation therapy (RT) in a phase II trimodality trial (Radiation Therapy Oncology Group protocol 0229). Patients and Methods: Patients (n=57) with stage III non-small cell lung cancer (pathologically proven N2 or N3) were eligible. Induction chemotherapy consisted of weekly carboplatin (AUC = 2.0) and paclitaxel 50 mg/m{sup 2}. Concurrent RT was prescribed, with 50.4 Gy to the mediastinum and primary tumor and a boost of 10.8 Gy to all gross disease. The mediastinum was pathologically reassessed after completion of chemoradiation. The primary endpoint of the study was MNC, with secondary endpoints of 2-year overall survival and postoperative morbidity/mortality. Results: The grade 3/4 toxicities included hematologic 35%, gastrointestinal 14%, and pulmonary 23%. Forty-three patients (75%) were evaluable for the primary endpoint. Twenty-seven patients achieved the primary endpoint of MNC (63%). Thirty-seven patients underwent resection. There was a 14% incidence of grade 3 postoperative pulmonary complications and 1 30-day, postoperative grade 5 toxicity (3%). With a median follow-up of 24 months for all patients, the 2-year overall survival rate was 54%, and the 2-year progression-free survival rate was 33%. The 2-year overall survival rate was 75% for those who achieved nodal clearance, 52% for those with residual nodal disease, and 23% for those who were not evaluable for the primary endpoint (P=.0002). Conclusions: This multi-institutional trial confirms the ability of neoadjuvant concurrent chemoradiation with full-dose RT to sterilize known mediastinal nodal disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-201-07: Exploring the Utility of 4D FDG-PET/CT Scans in Design of Radiation Therapy Planning Compared with 3D PET/CT: A Prospective Study

Purpose: A method using four-dimensional(4D) PET/CT in design of radiation treatment planning was proposed and the target volume and radiation dose distribution changes relative to standard three-dimensional (3D) PET/CT were examined. Methods: A target deformable registration method was used by which the whole patient’s respiration process was considered and the effect of respiration motion was minimized when designing radiotherapy planning. The gross tumor volume of a non-small-cell lung cancer was contoured on the 4D FDG-PET/CT and 3D PET/CT scans by use of two different techniques: manual contouring by an experienced radiation oncologist using a predetermined protocol; another technique using a constant threshold of standardized uptake value (SUV) greater than 2.5. The target volume and radiotherapy dose distribution between VOL3D and VOL4D were analyzed. Results: For all phases, the average automatic and manually GTV volume was 18.61 cm3 (range, 16.39–22.03 cm3) and 31.29 cm3 (range, 30.11–35.55 cm3), respectively. The automatic and manually volume of merged IGTV were 27.82 cm3 and 49.37 cm3, respectively. For the manual contour, compared to 3D plan the mean dose for the left, right, and total lung of 4D plan have an average decrease 21.55%, 15.17% and 15.86%, respectively. The maximum dose of spinal cord has an average decrease 2.35%. For the automatic contour, the mean dose for the left, right, and total lung have an average decrease 23.48%, 16.84% and 17.44%, respectively. The maximum dose of spinal cord has an average decrease 1.68%. Conclusion: In comparison to 3D PET/CT, 4D PET/CT may better define the extent of moving tumors and reduce the contouring tumor volume thereby optimize radiation treatment planning for lung tumors.

60 APPLIED LIFE SCIENCES↗

Hanford Double Shell Waste Tank Corrosion Studies (Final Report FY2023)

For fiscal year (FY) 2023, the Savannah River National Laboratory (SRNL) focused on two experimental tasks related to Hanford Double Shell Tank (DST) chemistry and integrity. The first task focused on understanding risk of corrosion due to formation of either continuous layers or discrete patches of solids on the tanks’ inner sidewalls and bottoms. Differences in the conductivity between various layers of the tank (e.g., solids, liquid, etc.) could result in differences in the electrochemical potential of the tank metal at various locations. The electrochemical potential difference may result in a corrosion current between the coupled surfaces. In FY23, SRNL investigated test configurations and protocols that could evaluate the presence of a galvanic couple between the tank bottom and the tank wall.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Abdominal manifestations of hereditary hemorrhagic telangiectasia: a series of 333 patients over 15 years

Purpose: Hereditary hemorrhagic telangiectasia (HHT) is an autosomal dominant multi-organ vascular disorder that commonly affects the gastrointestinal tract and the liver resulting in telangiectasias and arteriovenous malformations (AVMs). Previous studies looking at the prevalence of liver and abdominal organ involvement in HHT have been limited by differing imaging techniques and sample size limitations. We sought to define the prevalence of HHT related abdominal vascular abnormalities using optimized multiphasic contrast-enhanced abdominal computed tomography (CT) exams in a large cohort of HHT patients. Methods: Between January 2001 and May 2015; we identified a total of 333 consecutive HHT patients who had undergone a dedicated HHT protocol multiphase abdominal CT at our institution. The CT exams were reviewed by three board certified abdominal radiologists for the presence of vascular abnormalities involving the liver, pancreas, spleen, and other abdominal organs. Vascular abnormalities involving the liver were further categorized as telangiectasias, large confluent vascular masses, perfusion abnormalities, or hepatic shunts. Results: In patients with abdominal vascular abnormalities, the liver was the most commonly involved organ, with 180 out of 333 (54.1%) patients demonstrating at least one hepatic vascular abnormality (telangiectasia, confluent vascular mass, transient perfusion abnormalities, and hepatic shunts), with most (70.0%) demonstrating multiple hepatic vascular abnormalities. The other most common organs involved included the pancreas (18.0%), spleen (6.3%), and small bowel (4.5%). Conclusion: In patients with the clinical diagnosis of HHT, greater than half demonstrate an abdominal vascular abnormality, with the most commonly involved organ being the liver. These may be under recognized on routine or single phase contrast-enhanced CT of the abdomen. This supports the use of optimized multiphasic abdominal CT exams as an important tool for the evaluation and screening of patients with HHT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phosphatidylserine Asymmetry Promotes the Membrane Insertion of a Transmembrane Helix

The plasma membrane (PM) contains an asymmetric distribution of lipids between the inner and outer bilayer leaflets. A lipid of special interest in eukaryotic membranes is the negatively charged phosphatidylserine (PS). In healthy cells, PS is actively sequestered to the inner leaflet of the PM, but PS redistributes to the outer leaflet when the cell is damaged or at the onset of apoptosis. Yet, the influence of PS asymmetry on membrane protein structure and folding are poorly understood. The pH low insertion peptide (pHLIP) adsorbs to the membrane surface at a neutral pH, but it inserts into the membrane at an acidic pH. We have previously observed that in symmetric vesicles, PS affects the membrane insertion of pHLIP by lowering the pH midpoint of insertion. In this work, we researched the effect of PS asymmetry on the membrane interaction of pHLIP. We developed a modified protocol to create asymmetric vesicles containing PS and employed Annexin V labeled with an Alexa Fluor 568 fluorophore as a new probe to quantify PS asymmetry. We observed that the membrane insertion of pHLIP was promoted by the asymmetric distribution of negatively charged PS, which causes a surface charge difference between bilayer leaflets. Our results indicate that lipid asymmetry can modulate the formation of an α-helix on the membrane. A corollary is that model studies using symmetric bilayers to mimic the PM may fail to capture important aspects of protein-membrane interactions.

59 BASIC BIOLOGICAL SCIENCES↗

Refine your search to explore more results.