Search NASA⌕ Search

SEARCH · Search NASA

Results for “testing statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

An Evaluation of Flash Cells Used in Critical Applications

Due to the common use of Flash technology in many commercial and industrial Programmable Logic Devices (PLDs) such as FPGAs and mixed-signal microcontrollers, flash technology is being utilized in fuzed munition applications. This presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. Initial test results based on a study of charge loss in flash cells in an FPGA device is presented. Statistical data taken from a small sample set indicates quantifiable charge loss for devices stored at both room temperature and 150 C. Initial evaluation of the distribution of threshold voltage in a large sample set (800 devices) is presented. The magnitude of charge loss from exposure to electrostatic discharge and electromagnetic fields is measured and presented. Simulated data (and measured data as available) resultant from harsh-environment testing (neutron, heavy ion, EMP) is presented.

Data Retention↗

Study of one-dimensional spectral dynamic equations of the Reynolds stresses in homogeneous anisotropic turbulence: Application to split-spectrum modeling

The CTR numerical data base generated by direct simulation of homogeneous anisotropic turbulence was used to calculate all of the terms in the spectral balance equations for the turbulent Reynolds stresses. The aim in not only to test the main closure assumptions used in the split-spectrum models, but also to try to devise improved hypotheses deduced from the statistical information. Numerical simulations of turbulent flows provide a large amount of data, a thought provoking wealth of information. The main advantage of this type of comparison is that a great variety of flows can be considered, and this is necessary to test closure hypotheses. Moreover various initial conditions can be introduced in the calculation, even if they are not experimentally feasible. All the terms in the spectral equations can be calculated. The limited Reynolds numbers of the simulations and the statistical noise caused by a small sample, particularly at the large scales, causes some difficulty in the interpretation of the results, but the method of approach proved to be a powerful tool for testing and improving spectral closures.

Schiestel, R.↗

Fracture Strength Determination Methods for Ceramic Materials Applied to Uranium Dioxide

The Advanced Fuels Campaign is currently focusing on development of accident-tolerant fuels that possess a range of property modifications intended to improve fuel performance during accident and transient conditions as well as extend license limits to burnups beyond 62 MWd/kgU. Both of these drivers have identified understanding and mitigating fuel cracking as a key performance criterion. Small-scale cantilever beam testing has been identified as a plausible method by which to collect fracture data for UO 2 as a function of chemical and structural evolutions introduced either during fabrication or irradiation. While this method has been found to be capable of providing data that are in reasonable agreement with literature for unirradiated UO 2 , the inherently small sample volumes that can be sampled limit its ability to capture the statistical nature of mechanisms that govern the fracture of brittle ceramics. A biaxial flexure strength test was developed to be used for unirradiated UO 2 . This method is standard in the community, but no systems presently in use at national laboratories, universities, or private companies are available to be used for nuclear fuel materials. This report describes the operation and benchmarking of this system, which has been validated for a number of common oxides. Future work will extend this system to characterization of both doped UO 2 and other relevant microstructural modifications that can also be measured using small-scale cantilever beam testing. Comparison of datasets collected using both methods will allow the overall applicability of small-scale techniques to be assessed and provide confidence or bounds on their use for irradiated fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi-Axis Identifiability Using Single-Surface Parameter Estimation Maneuvers on the X-48B Blended Wing Body

The problem of parameter estimation on hybrid-wing-body type aircraft is complicated by the fact that many design candidates for such aircraft involve a large number of aero- dynamic control effectors that act in coplanar motion. This fact adds to the complexity already present in the parameter estimation problem for any aircraft with a closed-loop control system. Decorrelation of system inputs must be performed in order to ascertain individual surface derivatives with any sort of mathematical confidence. Non-standard control surface configurations, such as clamshell surfaces and drag-rudder modes, further complicate the modeling task. In this paper, asymmetric, single-surface maneuvers are used to excite multiple axes of aircraft motion simultaneously. Time history reconstructions of the moment coefficients computed by the solved regression models are then compared to each other in order to assess relative model accuracy. The reduced flight-test time required for inner surface parameter estimation using multi-axis methods was found to come at the cost of slightly reduced accuracy and statistical confidence for linear regression methods. Since the multi-axis maneuvers captured parameter estimates similar to both longitudinal and lateral-directional maneuvers combined, the number of test points required for the inner, aileron-like surfaces could in theory have been reduced by 50%. While trends were similar, however, individual parameters as estimated by a multi-axis model were typically different by an average absolute difference of roughly 15-20%, with decreased statistical significance, than those estimated by a single-axis model. The multi-axis model exhibited an increase in overall fit error of roughly 1-5% for the linear regression estimates with respect to the single-axis model, when applied to flight data designed for each, respectively.

Ratnayake, Nalin A.↗

Field Assessment of Sensorimotor Function Following Long-Duration Spaceflight

INTRODUCTION: Field assessments of functional task performance following long duration spaceflight are critical to characterize the risk associated with sensorimotor adaptation. A portable test battery involving sit-to-stand, prone-to-stand, walk and turn with obstacle, and tandem walking has been implemented during pre- and postflight testing to provide Sensorimotor Standard Measures that could be implemented in remote test locations. METHODS: To date, 19 astronauts (12 males, 7 females) participated in this study before and after 6–8-month expeditions to the International Space Station (198 ± 70 days, mean ±std). Ethics approvals were obtained, and all subjects provided informed consent. Tests were conducted preflight, within a few hours after landing, and then 1 day and 6–11 days later. Time to stability was the outcome measure for both standing tasks, time to completion and turn rate for the walk and turn task, and percent complete steps for the tandem walking (eyes open and closed). Statistical analyses included mixed effects (multi-level) generalized linear models. RESULTS: Consistent with previous Field Tests, significant effects of spaceflight were observed during the initial testing including longer times to stabilize posture when standing, longer times to complete the short obstacle walk, and fewer correct steps during tandem walking. The recovery timeline varied with task complexity, generally taking longer when either the basis of support was limited (e.g., tandem walk) and/or visual cues were deprived (eyes closed). DISCUSSION: These data suggest that additional sensorimotor-based countermeasures may be necessary to maintain functional performance during long-duration spaceflight. Maintaining core measures as new countermeasures are implemented during future missions will be instrumental in assessing their efficacy. This test battery will also serve as the basis for developing sensorimotor assessments during future space exploration.

Scott Jonathan Wood↗

Improved quality metrics for association and reproducibility in chromatin accessibility data using mutual information

Correlation metrics are widely utilized in genomics analysis and often implemented with little regard to assumptions of normality, homoscedasticity, and independence of values. This is especially true when comparing values between replicated sequencing experiments that probe chromatin accessibility, such as assays for transposase-accessible chromatin via sequencing (ATAC-seq). Such data can possess several regions across the human genome with little to no sequencing depth and are thus non-normal with a large portion of zero values. Despite distributed use in the epigenomics field, few studies have evaluated and benchmarked how correlation and association statistics behave across ATAC-seq experiments with known differences or the effects of removing specific outliers from the data. Here, we developed a computational simulation of ATAC-seq data to elucidate the behavior of correlation statistics and to compare their accuracy under set conditions of reproducibility. Using these simulations, we monitored the behavior of several correlation statistics, including the Pearson’s R and Spearman’s ρ coefficients as well as Kendall’s τ and Top–Down correlation. We also test the behavior of association measures, including the coefficient of determination R 2 , Kendall’s W, and normalized mutual information. Our experiments reveal an insensitivity of most statistics, including Spear man’s ρ, Kendall’s τ, and Kendall’s W, to increasing differences between simulated ATAC-seq replicates. The removal of co-zeros (regions lacking mapped sequenced reads) between simulated experiments greatly improves the estimates of correlation and association. After removing co-zeros, the R 2 coefficient and normalized mutual information display the best performance, having a closer one-to-one relationship with the known portion of shared, enhanced loci between simulated replicates. When comparing values between experimental ATAC-seq data using a random forest model, mutual information best predicts ATAC-seq replicate relationships. Collectively, this study demonstrates how measures of correlation and association can behave in epigenomics experiments. We provide improved strategies for quantifying relationships in these increasingly prevalent and important chromatin accessibility assays.

59 BASIC BIOLOGICAL SCIENCES↗

Regulatory Testing of WTP HL W Glasses for Compliance with Delisting Requirements, VSL-03R3780-1, Rev. 1

(Part of the data collected for this work and discussed in this report was subject to data quality and bias issues. All the affected tests have subsequently been repeated, as directed by the Waste Treatment Plant Project, and new statistical analyses have been performed on the revised data set. A subsequently-issued report supercedes this report and describes the revised data, together with the revised composition-property models (Kot et al. 2004). The reader should refer to the new report for discussion of the revised data set and composition-property (TCLP cadmium release) models. None of the data for the spike glasses, designed for Case 1 and Case 2 COPCs testing, were affected by this issue.)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detached-Eddy Simulation Based on the V2-F Model

Detached-eddy simulation (DES) based on the v(sup 2)-f Reynolds-averaged Navier-Stokes (RANS) model is developed and tested. The v(sup 2)-f model incorporates the anisotropy of near-wall turbulence which is absent in other RANS models commonly used in the DES community. The v(sup 2)-f RANS model is modified in order the proposed v(sup 2)-f-based DES formulation reduces to a transport equation for the subgrid-scale kinetic energy isotropic turbulence. First, three coefficients in the elliptic relaxation equation are modified, which is tested in channel flows with friction Reynolds number up to 2000. Then, the proposed v(sup 2)-f DES model formulation is derived. The constant, C(sub DES), required in the DES formulation was calibrated by simulating both decaying and statistically-steady isotropic turbulence. After C(sub DES) was calibrated, the v(sub 2)-f DES formulation is tested for flow around a circular cylinder at a Reynolds number of 3900, in which case turbulence develops after separation. Simulations indicate that this model represents the turbulent wake nearly as accurately as the dynamic Smagorinsky model. Spalart-Allmaras-based DES is also included in the cylinder flow simulation for comparison.

Jee, Sol Keun↗

Statistics Clinic

Do you have elevated p‐values? Is the data analysis process getting you down? Do you experience anxiety when you need to respond to criticism of statistical methods in your manuscript? You may be suffering from Insufficient Statistical Support Syndrome (ISSS). For symptomatic relief of ISSS, come for a free consultation with JSC biostatisticians at our help desk during the poster sessions at the HRP Investigators Workshop. Get answers to common questions about sample size, missing data, multiple testing, when to trust the results of your analyses and more. Side effects may include sudden loss of statistics anxiety, improved interpretation of your data, and increased confidence in your results.

Feiveson, Alan H.↗

Statistical Analysis in Support of Control Fuel Temperature for the Advanced Gas Reactor Experiments

There are four completed tests among a series of Advanced Gas Reactor (AGR) irradiation experiments that are being conducted within the Advanced Reactor Technologies (ART) Fuel Development and Qualification Program. The main objectives of the fuel experimental campaigns are to provide the necessary data on fuel performance to support fuel process development, qualify a fuel design and fabrication process for normal operation and hypothetical accident conditions, and support development and validation of fuel performance and fission product transport models and codes.1 Since this tristructural isotropic fuel is qualified to be used in high temperature gas-cooled reactors (HTGRs), it is essential that the testing conditions of fuel irradiations are designed to mimic those in the conceptual gas reactors. As a result, temperatures of the AGR test fuel have to be maintained within a specified range that is typical of the HTGRs. In each AGR capsule, the test fuel temperature is controlled independently using a variable fraction neon and helium gas mixture that fills the gap volume for each capsule. The temperature as measured by a thermocouple (TC) terminated in the graphite holder (which houses fuel compacts) is used as a feedback for the gas flow controllers. Direct temperature measurement for fuel compacts is not possible because contact between a TC head and fuel particle could lead to undesirable failures. Therefore, an ABAQUS based finite element thermal model was created to predict the daily average fuel temperatures during the entire irradiation period.2,3 It is well-known that extended exposure to neutron irradiation and high temperatures leads to changes in geometries of fuel compacts and graphite holder, which result in changes of the gas gap leading to a change in the relationship between TC and fuel temperatures. In addition, TCs are also expected to drift and sometimes fail under irradiation conditions. These facts make maintaining test fuel temperature within a specified range challenging. This paper describes how the regression analysis methods are used in conjunction of calculated fuel temperatures from early irradiation periods (when irradiation effect is relatively small) to effectively control fuel temperature for the remaining irradiation, when irradiation effect became profound. This is particularly important in the event of all TCs in a capsule fail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Statistical Analysis in Support of Fuel Temperature Control in the Advanced Gas Reactor Experiments

There are four completed tests among a series of Advanced Gas Reactor (AGR) irradiation experiments that are being conducted within the Advanced Reactor Technologies (ART) Fuel Development and Qualification Program. The main objectives of the fuel experimental campaigns are to provide the necessary data on fuel performance to support fuel process development, qualify a fuel design and fabrication process for normal operation and hypothetical accident conditions, and support development and validation of fuel performance and fission product transport models and codes. Since this tri-structural isotropic fuel is qualified to be used in high temperature gas-cooled reactors (HTGRs), it is essential that the testing conditions of fuel irradiations are designed to mimic those in the conceptual gas reactors. As a result, temperatures of the AGR test fuel have to be maintained within a specified range that is typical of the HTGRs. In each AGR capsule, the test fuel temperature is controlled independently using a variable fraction neon and helium gas mixture that fills the gap volume for each capsule. The temperature as measured by a thermocouple (TC) terminated in the graphite holder (which houses fuel compacts) is used as a feedback for the gas flow controllers. Direct temperature measurement for fuel compacts is not possible because contact between a TC head and fuel particle could lead to undesirable failures. Therefore, an ABAQUS-based finite element thermal model was created to predict the daily average fuel temperatures during the entire irradiation period. It is well-known that extended exposure to neutron irradiation and high temperatures leads to changes in geometries of fuel compacts and graphite holder, which results in changes of the gas gap, leading to a change in the relationship between TC and fuel temperatures. In addition, TCs are expected to drift and sometimes fail under irradiation conditions. These facts make maintaining test fuel temperature within a specified range challenging. This paper describes how the regression analysis methods are used in conjunction with calculated fuel temperatures from early irradiation periods (when the irradiation effect is relatively small) to effectively control fuel temperature for the remaining irradiation (when the irradiation effect became profound). This is particularly important in the event when all TCs in a capsule fail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PSF–NET: A Nonparametric Point-spread Function Model for Ground-based Optical Telescopes

Ground-based optical telescopes are seriously affected by atmospheric turbulence induced aberrations. Understanding properties of these aberrations is important both for instrument design and image restoration method development. Because the point-spread function can reflect performance of the whole optic system, it is appropriate to use the point-spread function to describe atmospheric turbulence induced aberrations. Assuming point-spread functions induced by the atmospheric turbulence with the same profile belong to the same manifold space, we propose a nonparametric point-spread function—PSF–NET. The PSF–NET has a cycle convolutional neural network structure and is a statistical representation of the manifold space of PSFs induced by the atmospheric turbulence with the same profile. Testing the PSF–NET with simulated and real observation data, we find that a well trained PSF–NET can restore any short exposure images blurred by atmospheric turbulence with the same profile. Besides, we further use the impulse response of the PSF–NET, which can be viewed as the statistical mean PSF, to analyze interpretation properties of the PSF–NET. We find that variations of statistical mean PSFs are caused by variations of the atmospheric turbulence profile: as the difference of the atmospheric turbulence profile increases, the difference between statistical mean PSFs also increases. The PSF–NET proposed in this paper provides a new way to analyze atmospheric turbulence induced aberrations, which would benefit the development of new observation methods for ground-based optical telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

Life Qualification of Hall Thrusters By Analysis and Test

High power Hall thrusters under development for deep space robotic and human exploration missions have demanding lifetime and operational requirements that make thruster life qualification challenging. The required burn times make it infeasible to conduct multiple tests with durations exceeding the life requirement, and complex wearout phenomena and the need for power throttling during missions complicate analyses and testing. The traditional qualification approach, a single life test that typically demonstrates 50 to 100% margin on the required lifetime, does not provide enough information to demonstrate low failure risk. It is a weak source of statistical information about the location of the peak in the failure probability distribution and provides no information on the width of the distribution. Testing does provide information that can be used to validate physics-based models of failure processes, however, and the combination can be used to assess mission risk. Validated, conservative, deterministic analysis can be used to demonstrate that most failure processes have such large margins that more detailed analysis is unnecessary. For a subset of the failure modes a more detailed probabilistic analysis is required. Pole erosion in a 12.5 kW Hall thruster is used as a detailed example of this qualification process.

Brophy, John R.↗

Poisson vs. Gaussian statistics for sparse X-ray data: Application to the soft X-ray spectrometer

Abstract Reliable results when fitting X-ray data require proper consideration of the statistics involved. We probe the impact of Gaussian versus Poisson statistics at low count levels using both the standard χ2 method and maximum likelihood based on Poisson (C) statistics. The difference is studied and quantified through simulated spectra with known properties. We then test the results through analysis of Mn Kα calibration data taken with the flight spare microcalorimeter for the Hitomi soft X-ray spectrometer. Through comparison with simulations, our results show that the χ2 method tends to give overly optimistic estimates of the detector energy resolution, in particular when there are few counts. Given an energy resolution of ∼5 eV and a line with about 100 photons, the line width becomes ∼10% lower in the χ2 method than in Poisson statistics. This is a consequence of the uncertainties being dominated by counting statistics, and therefore highlights the need to choose the appropriate fit statistic.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic analysis of coding and noncoding DNA sequences using methods of statistical linguistics

We compare the statistical properties of coding and noncoding regions in eukaryotic and viral DNA sequences by adapting two tests developed for the analysis of natural languages and symbolic sequences. The data set comprises all 30 sequences of length above 50 000 base pairs in GenBank Release No. 81.0, as well as the recently published sequences of C. elegans chromosome III (2.2 Mbp) and yeast chromosome XI (661 Kbp). We find that for the three chromosomes we studied the statistical properties of noncoding regions appear to be closer to those observed in natural languages than those of coding regions. In particular, (i) a n-tuple Zipf analysis of noncoding regions reveals a regime close to power-law behavior while the coding regions show logarithmic behavior over a wide interval, while (ii) an n-gram entropy measurement shows that the noncoding regions have a lower n-gram entropy (and hence a larger "n-gram redundancy") than the coding regions. In contrast to the three chromosomes, we find that for vertebrates such as primates and rodents and for viral DNA, the difference between the statistical properties of coding and noncoding regions is not pronounced and therefore the results of the analyses of the investigated sequences are less conclusive. After noting the intrinsic limitations of the n-gram redundancy analysis, we also briefly discuss the failure of the zeroth- and first-order Markovian models or simple nucleotide repeats to account fully for these "linguistic" features of DNA. Finally, we emphasize that our results by no means prove the existence of a "language" in noncoding DNA.

NASA Discipline Number 14-10↗

A comparison of single-cycle versus multiple-cycle proof testing strategies

An evaluation of single-cycle and multiple-cycle proof testing (MCPT) strategies for SSME components is described. Data for initial sizes and shapes of actual SSME hardware defects are analyzed statistically. Closed-form estimates of the J-integral for surface flaws are derived with a modified reference stress method. The results of load- and displacement-controlled stable crack growth tests on thin IN-718 plates with deep surface flaws are summarized. A J-resistance curve for the surface-cracked configuration is developed and compared with data from thick compact tension specimens. The potential for further crack growth during large unload/reload cycles is discussed, highlighting conflicting data in the literature. A simple model for ductile crack growth during MCPT based on the J-resistance curve is used to study the potential effects of key variables. The projected changes in the crack size distribution during MCPT depend on the interactions between several key parameters, including the number of proof cycles, the nature of the resistance curve, the initial crack size distribution, the component boundary conditions (load vs. displacement control), and the magnitude of the applied load or displacement. The relative advantages of single-cycle and multiple-cycle proof testing appear to be specific, therefore, to individual component geometry, material, and loading.

Hudak, S. J., Jr.↗

Hypovolemia Induced Orthostatic Hypotension in Presyncopal Astronauts and Normal Subjects Related to Hypoadrenergic Responsiveness

Circulating blood volume is reduced during spaceflight, making astronauts hemodynamically compromised. After landing, astronauts separate into two groups. One group compensates for the hypovolemia with a hyper-sympathetic response during upright tilt testing and can complete a tilt test with few symptoms. The other group is unable to mount a hyper-sympathetic response and experiences orthostatic hypotension and presyncope during upright tilt tests. We tested the hypothesis that hypovolemia alone, in the absence of spaceflight, also would cause subjects to separate into presyncopal and non-presyncopal groups according to their sympathetic responses during tilt. We studied 20 subjects, including 10 veteran astronauts, on three occasions. On Days 1 (normovolemia) and 3 (hypovolemia), plasma volume, tilt tolerance and supine and standing plasma norepinephrine levels were measured. Forty hours prior to Day 3, subjects were given intravenous furosemide, followed by 36 hours of a 10MEq Na diet. Statistical comparisons were made between normovolemia and hypovolemia responses. This protocol reproduced landing day tilt test outcomes with 100% fidelity in the astronauts. Similarly to patterns reported after flight, non-presyncopal subjects had greater norepinephrine responses to tilt during hypovolemia compared to normovolemia (580 plus or minus 79 vs. 298 plus or minus 37 pg/ml, P less than 0.05), but presyncopal subjects had no increase (180 plus or minus 44 vs. 145 plus or minus 32 pg/ml, P=NS). This model can be used to predict astronauts who will become presyncopal on landing day, so that prospective, individualized countermeasures can be developed. Within patient populations, it can be used to study the interaction of volemic state and the sympathetic nervous system.

Meck, Janice V.↗

Poisson vs. Gaussian statistics for sparse X-ray data: Application to the soft X-ray spectrometer

Reliable results when fitting X-ray data require proper consideration of the statistics involved. We probe the impact of Gaussian versus Poisson statistics at low count levels using both the standard χ^(2) method and maximum likelihood based on Poisson (C) statistics. The difference is studied and quantified through simulated spectra with known properties. We then test the results through analysis of Mn Kα calibration data taken with the flight spare microcalorimeter for the Hitomi soft X-ray spectrometer. Through comparison with simulations, our results show that the χ^(2) method tends to give overly optimistic estimates of the detector energy resolution, in particular when there are few counts. Given an energy resolution of ∼5 eV and a line with about 100 photons, the line width becomes ∼10% lower in the χ^(2) method than in Poisson statistics. This is a consequence of the uncertainties being dominated by counting statistics, and therefore highlights the need to choose the appropriate fit statistic.

Shinya Yamada↗

Refine your search to explore more results.