Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure

A single-molecule three-dimensional (3D) structure is essential for understanding the thermal vibrations and dynamics as well as the conformational changes during the chemical reaction of macromolecules. Individual-particle electron tomography (IPET) is an approach for obtaining a snap-shot 3D structure of an individual macromolecule particle by aligning the tilt series of electron tomographic (ET) images of a targeted particle through a focused iterative 3D reconstruction method. The method can reduce the influence on the 3D reconstruction from large-scale image distortion and deformation. Due to the mechanical tilt limitation, 3D reconstruction often contains missing-wedge artifacts, presented as elongation and an anisotropic resolution. Here, we report a post-processing method to correct the missing-wedge artifact. This low-tilt tomographic reconstruction (LoTToR) method contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination.

97 MATHEMATICS AND COMPUTING↗

Fabrication and characterization of a nanoporous NiO film with high specific energy and power via an electrochemical dealloying approach

Graphical abstract: The maximum values were 170 Wh kg{sup −1} and 27.5 kW kg{sup −1} for specific energy and power at the potential window of 1.1 V, respectively. As so far as we know, the values of specific energy and power were both the highest than that reported in literatures. - Highlights: • We developed a convenient approach to fabricate the three-dimensional nanoporous NiO film. • The nanoporous films contain irregular 3D interconnected nanosheets structure with open channels. • The film as supercapacitor electrode showed excellent specific capacitance values. • It is noticed that the nanoporous film exhibited high specific energy and high specific power. • The electrochemical electrode presented excellent cycling performance and low retention. - Abstract: A three-dimensional (3D) nanoporous NiO film was fabricated via a two-step process using an electrochemical route. This process included electrodeposition of the Ni/Zn alloy film and electrochemical dealloying using a direct-current power source. The scanning electron microscopy images suggest that the film has an irregular 3D interconnected nanosheet structure with open channels. The adsorption–desorption isotherms indicate that the as-prepared NiO film had a high specific surface area of 198 m g{sup −1} and a narrow pore size distribution, with two peaks at 2.7 and 5.1 nm. The specific capacitance of the sample reached 1670 F g{sup −1} at a discharge current density of 1 A g{sup −1}. In addition, the as-prepared nanoporous film exhibited high performance during a long-term cycling test. The maximum values for the specific energy and specific power at the 1.1 V potential window were 170 and 27.5 kW kg{sup −1}, respectively.

36 MATERIALS SCIENCE↗

WE-G-BRD-07: Automated MR Image Standardization and Auto-Contouring Strategy for MRI-Based Adaptive Brachytherapy for Cervix Cancer

Purpose: MRI-based adaptive brachytherapy (ABT) is an emerging treatment modality for patients with gynecological tumors. However, MR image intensity non-uniformities (IINU) can vary from fraction to fraction, complicating image interpretation and auto-contouring accuracy. We demonstrate here an automated MR image standardization and auto-contouring strategy for MRI-based ABT of cervix cancer. Methods: MR image standardization consisted of: 1) IINU correction using the MNI N3 algorithm, 2) noise filtering using anisotropic diffusion, and 3) signal intensity normalization using the volumetric median. This post-processing chain was implemented as a series of custom Matlab and Java extensions in MIM (v6.4.5, MIM Software) and was applied to 3D T2 SPACE images of six patients undergoing MRI-based ABT at 3T. Coefficients of variation (CV=σ/µ) were calculated for both original and standardized images and compared using Mann-Whitney tests. Patient-specific cumulative MR atlases of bladder, rectum, and sigmoid contours were constructed throughout ABT, using original and standardized MR images from all previous ABT fractions. Auto-contouring was performed in MIM two ways: 1) best-match of one atlas image to the daily MR image, 2) multi-match of all previous fraction atlas images to the daily MR image. Dice’s Similarity Coefficients (DSCs) were calculated for auto-generated contours relative to reference contours for both original and standardized MR images and compared using Mann-Whitney tests. Results: Significant improvements in CV were detected following MR image standardization (p=0.0043), demonstrating an improvement in MR image uniformity. DSCs consistently increased for auto-contoured bladder, rectum, and sigmoid following MR image standardization, with the highest DSCs detected when the combination of MR image standardization and multi-match cumulative atlas-based auto-contouring was utilized. Conclusion: MR image standardization significantly improves MR image uniformity. The combination of MR image standardization and multi-match cumulative atlas-based auto-contouring produced the highest DSCs and is a promising strategy for MRI-based ABT for cervix cancer.

60 APPLIED LIFE SCIENCES↗

NanoXCT - A High-Resolution Technique For TSV Characterization

Lab-based Transmission X-ray Microscopy and X-ray Computed Tomography (TXM/XCT) with sub-100 nm resolution are evaluated for their application in process and quality control in microelectronics, particularly for TSV characterization. These are the techniques of choice to localize defects in copper TSVs for 3D IC integration. In contrast to other techniques like Focused Ion Beam cross-sectioning and subsequent Scanning Electron Microscopy imaging, the region of interest, i.e. the TSV, is imaged nondestructively and three dimensionally. For flat samples like thinned wafers, the tilted rotational axis tomography is proposed instead of the limited angle tomography since the better in-plane resolution increases the quality of the resulting tomogram. Yield- and reliability-limiting processes in 3D TSV technology like voids and incomplete filled vias can be made visible for an array of adjacent TSVs during one measurement without affecting the TSV.

36 MATERIALS SCIENCE↗

Novel Magnetically Fluidized Bed Reactor Development for the Looping Process: Coal to Hydrogen Production R&D

The coal to hydrogen project utilizes the iron/iron oxide looping process to produce high purity hydrogen. The input energy for the process is provided by syngas coming from gasification process of coal. The reaction pathways for this process have been studied and favorable conditions for energy efficient operation have been identified. The Magnetically Stabilized Porous Structure (MSPS) is invented. It is fabricated from iron and silica particles and its repeatable high performance has been demonstrated through many experiments under various conditions in thermogravimetric analyzer, a lab-scale reactor, and a large scale reactor. The chemical reaction kinetics for both oxidation and reduction steps has been investigated thoroughly inside MSPS as well as on the surface of very smooth iron rod. Hydrogen, CO, and syngas have been tested individually as the reducing agent in reduction step and their performance is compared. Syngas is found to be the most pragmatic reducing agent for the two-step water splitting process. The transport properties of MSPS including porosity, permeability, and effective thermal conductivity are determined based on high resolution 3D CT x-ray images obtained at Argonne National Laboratory and pore-level simulations using a lattice Boltzmann Equation (LBE)-based mesoscopic model developed during this investigation. The results of those measurements and simulations provide necessary inputs to the development of a reliable volume-averaging-based continuum model that is used to simulate the dynamics of the redox process in MSPS. Extensive efforts have been devoted to simulate the redox process in MSPS by developing a continuum model consist of various modules for conductive and radiative heat transfer, fluid flow, species transport, and reaction kinetics. Both the Lagrangian and Eulerian approaches for species transport of chemically reacting flow in porous media have been investigated and verified numerically. Both approaches lead to correct prediction of hydrogen production rates over a large range of experimental conditions in the laboratory scale reactor and the bench-scale reactor. In the economic analysis, a comparison of the hydrogen production plants using iron/iron oxide looping cycle and the conventional process has been presented. Plant configurations are developed for the iron/iron oxide looping cycle. The study suggests a higher electric power generation but a lower hydrogen production efficiency comparing with the conventional process. Additionally, it was shown that the price of H 2 obtained from our reactor can be as low as $\$$1.7/kg, which is 22% lower than the current price of the H 2 obtained from reforming plants.

01 COAL, LIGNITE, AND PEAT↗

Comparison of three-dimensional particle tracking and sizing using plenoptic imaging and digital in-line holography

Digital in-line holography (DIH) and plenoptic photography are two techniques for single-shot, volumetric measurement of 3D particle fields. Here we present a comparison of the two methods by applying plenoptic imaging to experimental configurations that have been previously investigated with DIH. These experiments include the tracking of secondary droplets from the impact of a water drop on a thin film of water and tracking of pellets from a shotgun. Both plenoptic imaging and DIH successfully quantify the 3D nature of these particle fields. Furthermore, this includes measurement of the 3D particle position, individual particle sizes, and three-component velocity vectors. For the initial processing methods presented here, both techniques give out-of-plane positional accuracy of approximately 1–2 particle diameters. For a fixed image sensor, digital holography achieves higher effective in-plane spatial resolutions. However, collimated and coherent illumination makes holography susceptible to image distortion through index of refraction gradients, as demonstrated in the shotgun experiments. In contrast, plenoptic imaging allows for a simpler experimental configuration and, due to the use of diffuse, white-light illumination, plenoptic imaging is less susceptible to image distortion in the shotgun experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Application of Convolutional Neural Networks (CNNs) to Recognize Defects in 3D-Printed Parts

Cracks and pores are two common defects in metallic additive manufacturing (AM) parts. In this paper, deep learning-based image analysis is performed for defect (cracks and pores) classification/detection based on SEM images of metallic AM parts. Three different levels of complexities, namely, defect classification, defect detection and defect image segmentation, are successfully achieved using a simple CNN model, the YOLOv4 model and the Detectron2 object detection library, respectively. The tuned CNN model can classify any single defect as either a crack or pore at almost 100% accuracy. The other two models can identify more than 90% of the cracks and pores in the testing images. In addition to the application of static image analysis, defect detection is also successfully applied on a video which mimics the AM process control images. The trained Detectron2 model can identify almost all the pores and cracks that exist in the original video. This study lays a foundation for future in situ process monitoring of the 3D printing process.

36 MATERIALS SCIENCE↗

Quantitative characterization of high temperature oxidation using electron tomography and energy-dispersive X-ray spectroscopy

We report quantitative characterization of the high temperature oxidation process by using electron tomography and energy-dispersive X-ray spectroscopy. As a proof of principle, we performed 3D imaging of the oxidation layer of a model system (Mo 3 Si) at nanoscale resolution with elemental specificity and probed the oxidation kinetics as a function of the oxidation time and the elevated temperature. Our tomographic reconstructions provide detailed 3D structural information of the surface oxidation layer of the Mo 3 Si system, revealing the evolution of oxidation behavior of Mo 3 Si from early stage to mature stage. Based on the relative rate of oxidation of Mo 3 Si, the volatilization rate of MoO 3 and reactive molecular dynamics simulations, we propose a model to explain the mechanism of the formation of the porous silica structure during the oxidation process of Mo 3 Si. We expect that this 3D quantitative characterization method can be applied to other material systems to probe their structure-property relationships in different environments.

36 MATERIALS SCIENCE↗

Plastic shrinkage of mortars cured with a paraffin-based compound – Bimodal neutron/X-ray tomography study

Early-age drying (immediately after casting) of mortars and the corresponding plastic shrinkage were studied using bimodal neutron/X-ray computed tomography. This novel, correlative 3D imaging mode enabled studying simultaneously and without any source of spurious perturbation the water migration and loss processes together with the corresponding deformations due to plastic shrinkage. Bimodal imaging opens up new possibilities for studying dynamic processes of coupled water transport and deformations in porous solids. The measurements were carried out on model systems (cylindrical mortar specimens with height of 19 mm). The study focused on the effect of a paraffin-based curing compound. Our results confirm that when the curing compound was applied directly onto the drying surface in a sufficient amount, both the evaporation rate and the rate of vertical displacement (settlement) were substantially reduced. The results shed a new light on the mechanisms of plastic shrinkage and the action of curing compounds.

36 MATERIALS SCIENCE↗

SU-E-P-12: Pinnacle-Based Tool to Evaluate the Effect of Prostate Rotation as Determined by Calypso

Purpose: When the Calypso reports a large prostate rotation and one does not have the means to make corrections, it is helpful to quantify its dosimetric effects. We have devised a simple scheme to achieve this in Pinnacle TPS. If it is determined that the PTV margin is inadequate, an alternate larger-margin plan may be adapted for the day. Methods: A three-step process using the Pinnacle Image fusion module was formulated to analyze the clinical effect of prostate rotation. The process includes (1) translating the image set such that the rotational axis is about the isocenter, (2) performing 3D rotations of the structures of interest, and (3) restoring the coordinates associated with the plan. The rotated structures are imported and overlayed on the original plan for evaluation. The tool was applied to three prostate cancer patients with relatively large rotations (95 fractions total). Prostate rotations are primarily due to variations in bladder and rectal filling, which may also affect the seminal vesicles. It is difficult to estimate the perturbation of seminal vesicles for a given prostate rotation. Therefore, the Calypso-derived rotation matrix was applied only to CTV and PTV (CTV+5mm). Results: The rotations were predominantly in the pitch direction with an absolute value ranging from 0–29 degrees (Median = 10°, Average = 14.5°). For various magnitudes of rotation, the CTV V100 decreased from the original 100% to 99.6%/99%/95% for 10°/15°/29° rotations, respectively. Likewise, the PTV V100 diminished from 95% to 92%/89%/82%. Conclusion: A tool, consisting only of features within a TPS, was used to evaluate the dosimetric effect of prostate rotation. Our study shows that under large uncorrected rotations, the tumor coverage is degraded and may require intervention in the form of plan adaptation. To this end, alternate plans with variable margins can be generated in advance for daily adaption.

60 APPLIED LIFE SCIENCES↗

SU-E-J-45: The Correlation Between CBCT Flat Panel Misalignment and 3D Image Guidance Accuracy

Purpose To simulate the impact of CBCT flat panel misalignment on the image quality, the calculated correction vectors in 3D image guided proton therapy and to determine if these calibration errors can be caught in our QA process. Methods The X-ray source and detector geometrical calibration (flexmap) file of the CBCT system in the AdaPTinsight software (IBA proton therapy) was edited to induce known changes in the rotational and translational calibrations of the imaging panel. Translations of up to ±10 mm in the x, y and z directions (see supplemental) and rotational errors of up to ±3° were induced. The calibration files were then used to reconstruct the CBCT image of a pancreatic patient and CatPhan phantom. Correction vectors were calculated for the patient using the software’s auto match system and compared to baseline values. The CatPhan CBCT images were used for quantitative evaluation of image quality for each type of induced error. Results Translations of 1 to 3 mm in the x and y calibration resulted in corresponding correction vector errors of equal magnitude. Similar 10mm shifts were seen in the y-direction; however, in the x-direction, the image quality was too degraded for a match. These translational errors can be identified through differences in isocenter from orthogonal kV images taken during routine QA. Errors in the z-direction had no effect on the correction vector and image quality.Rotations of the imaging panel calibration resulted in corresponding correction vector rotations of the patient images. These rotations also resulted in degraded image quality which can be identified through quantitative image quality metrics. Conclusion Misalignment of CBCT geometry can lead to incorrect translational and rotational patient correction vectors. These errors can be identified through QA of the imaging isocenter as compared to orthogonal images combined with monitoring of CBCT image quality.

60 APPLIED LIFE SCIENCES↗

Development of a statistical model (tool) for classifying buried object detectability

To improve warfighter safety under changing requirements, assets must be adaptable and able to detect and mark buried hazards. Current GPR systems would benefit by improvements in speed, usability, and operational versatility to enhance operational effectiveness for all platforms and missions. Our sponsor requests that LLNL research GPR methodologies and approaches to allow for specific improvements to be made in those areas. MiRadar uses a novel multi-static array architecture coupled with tomographic processing to focus returned energy from the real (physical) and synthetic (motion-derived) apertures. 3D streaming movies of the subsurface are easily interpreted, slashing training times. Real-time processing codes enable imaging and operation three times faster; automated volumetric detection algorithms warn of possible hazards. In a two-week trial, multiple vehicle-mounted arrays and a new ultralightweight architecture on a small, unmanned aircraft system executed 498 runs, collecting over 400km of data on 13 preemplaced lanes containing 384 simulated buried threats.

42 ENGINEERING↗

Enhanced FIB-SEM systems for large-volume 3D imaging

Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 10 6 ?m 3 . These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processes and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology.

59 BASIC BIOLOGICAL SCIENCES↗

Imaging CSEM data in the presence of electrical anisotropy

Formation anisotropy should be incorporated into the analysis of controlled source electromagnetic (CSEM) data because failure to do so can produce serious artifacts in the resulting resistivity images for certain data configurations of interest. This finding is demonstrated in model and case studies. Sensitivity to horizontal resistivity will be strongest in the broadside electric field data where detectors are offset from the tow line. Sensitivity to the vertical resistivity is strongest for over flight data where the transmitting antenna passes directly over the detecting antenna. Consequently, consistent treatment of both over flight and broadside electric field measurements requires an anisotropic modeling assumption. To produce a consistent resistivity model for such data we develop and employ a 3D CSEM imaging algorithm that treats transverse anisotropy. The algorithm is based upon non-linear conjugate gradients and full wave equation modeling. It exploits parallel computing systems to effectively treat 3D imaging problems and CSEM data volumes of industrial size. Here we use it to demonstrate the anisotropic imaging process on model and field data sets from the North Sea and offshore Brazil. We also verify that isotropic imaging of over flight data alone produces an image generally consistent with the vertical resistivity. However, superior data fits are obtained when the same over flight data are analyzed assuming an anisotropic resistivity model.

54 ENVIRONMENTAL SCIENCES↗

Effects of pore-scale precipitation on permeability and flow

Here, the effects of calcite precipitation on porous media permeability and flow were evaluated with a combined experimental and modeling approach. X-ray microtomography images of two columns packed with glass beads and calcite (spar crystals) or aragonite (Bahamas ooids) injected with a supersaturated solution (log Ω = 1.42) were processed in order to calculate rates of calcite precipitation with a spatial resolution of 4.46 µm. Identification and localization of the newly precipitated crystals on the 3D images was performed and results used to calculate the crystal growth rates and velocities. The effects of carbonate precipitation were also evaluated in terms of the integrated precipitation rate over the length of the column, crystal shape, surface area and pore roughness changes. While growth was epitaxial on calcite spar, calcite rhombohedra formed on glass beads and clusters of polyhedrons formed on aragonite ooids. Near the column inlet, calcite precipitation occurred preferentially on carbonate grains compared to glass beads, with almost 100% of calcite spar surface area covered by new crystals versus 92% in the case of aragonite and 11% in the case of glass beads. Although the experimental chemistry and flow boundary conditions in the two columns were similar, their porosity-permeability evolution was different because the nucleation and subsequent crystal growth on the two substrates (i.e., calcite spar and aragonite ooids) was very different. The impact of mineral precipitation on pore-scale flow and permeability was evaluated using a pore-scale Stokes solver that accounted for the changes in pore geometry. For similar magnitude reductions in porosity, the decrease in permeability was highest within the sample that experienced the greatest increase in pore roughness. Various porous media models were generated to show the impact of different crystal growth patterns and pore roughness changes on flow and permeability-porosity relationship. Under constant flow rate boundary conditions, precipitation resulted in an increase in both the average and maximum velocities. Increases in pore roughness led to a more heterogeneous flow field, principally through the effects on the fastest and slowest velocities within the domain.

58 GEOSCIENCES↗

Pore2Chip: All-in-one python tool for soil microstructure analysis and micromodel design

The Pore2Chip Python package is designed to create 2D micromodels using extracted data from 3D X-ray computed tomography (XCT) images. This package helps analyze soil structure and function, allowing for the investigation of hydro-biogeochemical processes that impact mineral extraction and reactivity, oxygen concentrations, and nutrient availability in disturbed or managed soils. Key metrics encompass pore size distributions, pore throat size distributions, and connectivity (pore coordination numbers). The final output is a 2D scalable SVG design representing a core or aggregate. Designs can be fabricated with methods such as laser etching, 3D printing, and photolithography.

lab-on-chip↗

A Preliminary Comparison of Three Dimensional Particle Tracking and Sizing using Plenoptic Imaging and Digital In-line Holography

Digital in-line holography and plenoptic photography are two techniques for single-shot, volumetric measurement of 3D particle fields. Here we present a preliminary comparison of the two methods by applying plenoptic imaging to experimental configurations that have been previously investigated with digital in-line holography. These experiments include the tracking of secondary droplets from the impact of a water drop on a thin film of water and tracking of pellets from a shotgun. Both plenoptic imaging and digital in-line holography successfully quantify the 3D nature of these particle fields. This includes measurement of the 3D particle position, individual particle sizes, and three-component velocity vectors. For the initial processing methods presented here, both techniques give out-of-plane positional accuracy of approximately 1-2 particle diameters. For a fixed image sensor, digital holography achieves higher effective in-plane spatial resolutions. However, collimated and coherent illumination makes holography susceptible to image distortion through index of refraction gradients, as demonstrated in the shotgun experiments. On the other hand, plenotpic imaging allows for a simpler experimental configuration. Furthermore, due to the use of diffuse, white-light illumination, plenoptic imaging is less susceptible to image distortion in the shotgun experiments. Additional work is needed to better quantify sources of uncertainty, particularly in the plenoptic experiments, as well as develop data processing methodologies optimized for the plenoptic measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗