Search NASA⌕ Search

SEARCH · Search NASA

Results for “AC modules”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Real-time Simulation Framework for Hardware-in-the-Loop Testing of Multi-port Autonomous Reconfigurable Solar Power Plant (MARS)

Multiport autonomous reconfigurable solar power plant (MARS) has been proposed for integrated development of photovoltaic (PV) and energy storage system (ESS) that can connect to high-voltage direct current (HVdc) and alternating current (ac) transmission grid. To de-risk the development of this complex integrated system that consists of hundreds to thousands of power electronics modules, a controller hardware-in-the-loop (cHIL) test setup will be extremely beneficial. The cHIL testing can be used for evaluation of modules as well as the hierarchical control system in MARS. With the unique configuration of power electronics modules in MARS, it becomes necessary to develop custom-designed real-time simulation models in the cHIL setup in absence of off-the-shelf models. In this paper, high-fidelity dynamic model of MARS, control algorithms at the lower level, and required communication algorithms are developed and optimized for real-time performance in the cHIL setup. Real-time experimental results from the cHIL are provided.

Dong, Zerui↗

PS Ripple Study during the 2019 Fermilab Booster Experiment

S.02 has been one of the experiment of the 2019 Fermilab Booster Studies. Its goal had been to evaluate the tune ripple on beam stability. A prerequisite is to measure the voltage ripple in both AC and DC mode. With a good knowledge of the Booster transmission line model one can determine how voltage ripple leads to tune modulation depth at the same ripple frequency.

43 PARTICLE ACCELERATORS↗

Impute DC link (IDCL) cell based power converters and control thereof

Power flow controllers based on Imputed DC Link (IDCL) cells are provided. The IDCL cell is a self-contained power electronic building block (PEBB). The IDCL cell may be stacked in series and parallel to achieve power flow control at higher voltage and current levels. Each IDCL cell may comprise a gate drive, a voltage sharing module, and a thermal management component in order to facilitate easy integration of the cell into a variety of applications. By providing direct AC conversion, the IDCL cell based AC/AC converters reduce device count, eliminate the use of electrolytic capacitors that have life and reliability issues, and improve system efficiency compared with similarly rated back-to-back inverter system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimize Topology, Component Sizes, and Operating Strategy of Participant's Protype: Cooperative Research and Development Final Report

The purpose of the project was to complete testing of Shine Technologies LLC’s prototype power system called “Juicebox 3.0.” Testing of the prototype using NREL’s hardware-in-the-loop capabilities, including a DC power supply programmed to simulate PV module output and provide the JuiceBox 3.0 at the specified power level and with a load bank of sufficient capacity to mimic DC and AC loads connected to the outlets of the Juicebox 3.0. The unit is provided with SAE wire connectors. A photo of a JuiceBox 3.0 unit is shown in Figure 1 below.

14 SOLAR ENERGY↗

Plant-level performance and degradation of 31 GW DC of utility-scale PV in the United States

In this updated study, which samples 50% more capacity than the original and adds two additional years of operating history, we assess the performance of a fleet of 631 utility-scale PV plants totaling 31.0 GW DC (23.6 GW AC ) of capacity that achieved commercial operations in the United States from 2007-2018 and that have operated for at least two full calendar years. We use detailed information on individual plant characteristics, in conjunction with modeled irradiance data, to model expected or “ideal” capacity factors in each full calendar year of each plant’s operating history. A comparison of ideal versus actual first-year capacity factors finds that this fleet has modestly underperformed initial expectations (as modeled) on average, though perhaps due as much to modeling issues as to actual underperformance. We then analyze fleet-wide performance degradation in subsequent years by employing a “fixed effects” regression model to statistically isolate the impact of age on plant performance. The resulting average fleet-wide degradation rate of -1.2%/year (±0.1%) represents a slight improvement (seemingly driven by the oldest plants in our sample) over the -1.3%/year (±0.2%) found in our original study, yet is still of greater magnitude than is commonly found. We emphasize, however, that these fleet-wide estimates reflect both recoverable and unrecoverable degradation across the entire plant, and so will naturally be of greater magnitude than module- or cell-level studies, and/or studies that focus only on unrecoverable degradation. Moreover, when focusing on a sub-sample of newer and larger plants with higher DC:AC ratios—i.e., plants that more-closely resemble what is being built today—we find a more moderate sample-wide average performance decline of -0.7%/year (±0.4%), which is more in line with other estimates from the recent literature.

14 SOLAR ENERGY↗

Magnetic field-induced ferroelectricity in S = 1/2 kagome staircase compound PbCu 3 TeO 7

Ni 3 V 2 O 8 is an archetypical multiferroic material with a kagome staircase structure of S = 1 (Ni 2+ ) spins whose complex interplay between spin ordering and ferroelectricity has been studied for more than a decade. Here in this paper, we report a new kagome staircase compound PbCu 3 TeO 7 with Cu 2+ (S = 1/2) spins that exhibits two Néel temperatures at T N1 = 36 K and T N2 = 24 K, and a magnetic field (H)-induced electric polarization (P) below T N2 . Pyroelectric and magnetoelectric current measurements in magnetic fields up to 60 T reveal that for H||c of ~ 8.3 T, a spin-flop transition induces a transverse P||a with a magnitude of 15 µC/m 2 below T N2 . Furthermore, for a parallel configuration with P//H//a, two spin-flop transitions occur, the first at ~ 16 T with P//a of 14 µC/m 2 , and the second at ~ 38 T, where P disappears. Monte Carlo simulations based on 12 major exchange interactions uncover that a sinusoidal amplitude modulation of the spins occurs along the b-axis below T N1 and an incommensurate, proper screw-type spin order occurs in the ac-plane below T N2 . The simulation results show that P//a under H//c stems from a spin-flop transition facilitating an ab-plane-type spiral order, while the two successive spin-flop transitions for H//a result in spiral spin orders in the ab- and bc-planes. Based on the experimental and theoretical results, we establish field-induced magnetic and electric phase diagrams for the two H directions, demonstrating that the distorted kagome staircase structure with competing intra–interlayer interactions and lifted frustration creates a plethora of different noncollinear spin textures of S = 1/2 spins that in turn induce electric polarization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Review on Switching Device Fault, Protection, and Fault-Tolerant Topologies of Current Source Inverter

The fault modes, protection, and fault-tolerant topologies of voltage source inverters have been investigated for decades. However, issues and solutions related to the fault modes of current source inverters are less well understood. This paper summarizes some of the key topics relevant to a fault in current source inverters, including types of fault modes and their ramifications, post-fault protection methods, and fault- tolerant current source inverter topologies that have been presented in the literature.

42 ENGINEERING↗

High-efficiency grid-connected photovoltaic module integrated converter system with high-speed communication interfaces for small-scale distribution power generation

This paper presents a high-efficiency grid-connected photovoltaic (PV) module integrated converter (MIC) system with reduced PV current variation. The proposed PV MIC system consists of a high-efficiency step-up DC-DC converter and a single-phase full-bridge DC-AC inverter. An active-clamping flyback converter with a voltage-doubler rectifier is proposed for the step-up DC-DC converter. The proposed step-up DC-DC converter reduces the switching losses by eliminating the reverse-recovery current of the output rectifying diodes. To reduce the PV current variation introduced by the grid-connected inverter, a PV current variation reduction method is also suggested. The suggested PV current variation reduction method reduces the PV current variation without any additional components. Moreover, for centralized power control of distributed PV MIC systems, a PV power control scheme with both a central control level and a local control level is presented. The central PV power control level controls the whole power production by sending out reference power signals to each individual PV MIC system. The proposed step-up DC-DC converter achieves a high-efficiency of 97.5% at 260 W output power to generate the DC-link voltage of 350 V from the PV voltage of 36.1 V. The PV MIC system including the DC-DC converter and the DC-AC inverter achieves a high-efficiency of 95% with the PV current ripple less than 3% variation of the rated PV current. (author)

14 SOLAR ENERGY↗

Conformational similarity in the activation of caspase-3 and -7 revealed by the unliganded and inhibited structures of caspase-7

Caspase-mediated apoptosis has important roles in normal cell differentiation and aging and in many diseases including cancer, neuromuscular disorders and neurodegenerative diseases. Therefore, modulation of caspase activity and conformational states is of therapeutic importance. We report crystal structures of a new unliganded conformation of caspase-7 and the inhibited caspase-7 with the tetrapeptide Ac-YVAD-Cho. Different conformational states and mechanisms for substrate recognition have been proposed based on unliganded structures of the redundant apoptotic executioner caspase-3 and -7. The current study shows that the executioner caspase-3 and -7 have similar conformations for the unliganded active site as well as the inhibitor-bound active site. The new unliganded caspase-7 structure exhibits the tyrosine flipping mechanism in which the Tyr230 has rotated to block entry to the S2 binding site similar to the active site conformation of unliganded caspase-3. The inhibited structure of caspase-7/YVAD shows that the P4 Tyr binds the S4 region specific to polar residues at the expense of a main chain hydrogen bond between the P4 amide and carbonyl oxygen of caspase-7 Gln 276, which is similar to the caspase-3 complex. This new knowledge of the structures and conformational states of unliganded and inhibited caspases will be important for the design of drugs to modulate caspase activity and apoptosis.

08 HYDROGEN↗

LGFCS Prototype System Testing (Final Report)

In the project, LGFCS assembled and tested its modular SOFC Power System that incorporates all critical technology improvements identified for its “product-like” demonstration. This product demonstrator is expected to meet customer and LGFCS performance expectations for operation, availability, durability and serviceability. The principal technology improvements are aimed at increasing the fuel cell power output and reducing the stack degradation rate. Improvements were also made for added system robustness and increased reliability. The objective of this program is to test a 250kWe thermally self-sustaining modular solid oxide fuel cell (SOFC) Power System for a minimum of 5,000 hours while advancing this commercial prototype product demonstrator to a Technical Readiness Level (TRL) 7. The SOFC system was tested on a site provided by Stark State College in North Canton, Ohio. System performance and degradation as well as cost estimates were compared to established SOFC Program performance metrics to assess progress. The major achievements were to assemble, and QA qualify 70 fuel cell strips for 12 integrated blocks into a fuel cell vessel and install it into a generator module with the fuel and power electronics modules on the test site. Performance to date included over 1800 hours on load at 250 KWAC to the grid with a DC efficiency of 61% and AC efficiency of 55%. Power degradation was less than 0.4% per 1000 hours and NOx emissions met standards. The LGFCS SOFC Prototype System (GEN0) was demonstrated in an operational environment and therefore achieving Technical Readiness Level 7. The work presented here represents the efforts of all the employees of LG Fuel Cell Systems. Their dedication and hard work made GEN0 possible and successful.

03 NATURAL GAS↗

A 200 C Universal Gate Driver Integrated Circuit for Extreme Environment Applications

High-temperature power converters (dc-dc, dc-ac, etc.) have enormous potential in extreme environment applications, including automotive, aerospace, geothermal, nuclear, and well logging. For successful realization of such high-temperature power conversion modules, the associated control electronics also need to perform at high temperature. This paper presents a silicon-on-insulator (SOI) based high-temperature gate driver integrated circuit (IC) incorporating an on-chip low-power temperature sensor and demonstrating an improved peak output current drive over our previously reported work. This driver IC has been primarily designed for automotive applications, where the underhood temperature can reach 200 C. This new gate driver prototype has been designed and implemented in a 0.8 {micro}m, 2-poly, and 3-metal bipolar CMOS-DMOS (Double-Diffused Metal-Oxide Semiconductor) on SOI process and has been successfully tested for up to 200 C ambient temperature driving a SiC MOSFET and a SiC normally-ON JFET. The salient feature of the proposed universal gate driver is its ability to drive power switches over a wide range of gate turn-ON voltages such as MOSFET (0 to 20 V), normally-OFF JFET (-7 to 3 V), and normally-ON JFET (-20 to 0 V). The measured peak output current capability of the driver is around 5 A and is thus capable of driving several power switches connected in parallel. An ultralow-power on-chip temperature supervisory circuit has also been integrated into the die to safeguard the driver circuit against excessive die temperature ({ge}220 C). This approach utilizes increased diode leakage current at higher temperature to monitor the die temperature. The power consumption of the proposed temperature sensor circuit is below 10 {micro}W for operating temperature up to 200 C.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Special pinning phenomena in arrays of defects with gradient spatial distributions on niobium film

Flux pinning effect is related to the strong influence by the presence of defects that act as pinning centers. We present transport experiments that investigate the pinning properties in a spacing-graded array of pinning sites. We have found the asymmetric pinning by arrays of defects with modulated gradient spatial distributions on niobium film. One can clearly see the asymmetric pinning effect for the vortex motion. The dc voltage depends on the amplitude of the ac current and that there is a sharp maximum at matching fields. This curve, however, has an interesting sign reversal phenomenon below the first matching field, which will be investigated more in the future. The dc voltage as a function of dc and ac applied current gives evidence that the artificial arrays of gradient pinning site density induce ratchet effect. This effect can be used to control the vortex motion, which will be important for the application of vortex based on electronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PV power conditioning system using a three‐phase multilevel pulse width modulation inverter employing cascaded Scott transformers

Voltage source inverters (VSIs) are power converters that are considered essential in grid connected photovoltaic (PV) generators. There are several types of topologies for these converters. However, from the point of view of high‐quality AC output voltage, multilevel inverters are considered the most adequate. Under this context, this study proposes a new structure for the three‐phase DC−AC conversion stage for a grid‐connected PV system. It consists of two four‐leg two‐level voltage source inverters that are connected to two PV generators. These inverters are associated with two Scott transformers. The secondary windings of the transformer are connected in a way that allows a series connection. Due to this, a multilevel operation will be achieved. The performance of the proposed power conditioning system will be verified through simulation and experimental results.

Fernão Pires, Vitor↗

Fault-tolerant power-distribution modules for a power plant

Embodiments are directed to fault-tolerant power-distribution modules (PDM). A PDM is included in a power plant to provide a portion of the power generated by the plant as a direct current (DC) signal for the operation of the plant. A power-distribution system distributes a portion of the power generated by the plant to one or more PDMs, as an alternating current (AC) signal. The PDMs provide electrical power to various plant loads. The plant loads may be related to the safety of the operation of the power plant. At least one of the plant loads is a non-safety related load. A PDM may be a DC power supply. The power plant may include one or more power-generating module (PGM) assemblies. At least one of the PGM assemblies may include a nuclear reactor. Accordingly, the power plant may be a modular nuclear power plant.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, Control, and Protection of a 13.2 kV, 1 MVA Solid State Transformer for Electric Vehicle Extreme Fast Charging Station

In this article, a medium-voltage (MV) ac-dc solid state transformer (SST) for electric vehicle (EV) extreme fast charging (XFC) station is proposed. The SST adopts a cascaded H-bridge (CHB)-based structure where the active front end (AFE) power stages are connected in input-series followed by dual active bridge (DAB) converters connected in an output-parallel configuration providing galvanic isolation through a high-frequency transformer (HFT). The SST is rated for 1 MVA and connects directly to a three-phase 13.2 kV MV ac grid through ac switchgear and outputs 750-V dc. At the dc bus, several dc/dc converters are connected, each of which can charge an EV based on its battery capacity. A novel decentralized control architecture of the SST is adopted in this work which simplifies the MV dc link voltage and module-level power balancing. In addition, the local and central protection designs of the SST are presented which identify and respond to the internal fault of the system. Finally, the experimental validations of the SST hardware prototype are presented up to the rated voltage. Furthermore, this article details the design and implementation of the MV SST addressing the challenges of an isolated MV class power converter for connecting directly to the MV ac grid with unique controller architecture, distributed protection framework, and SST constructional features.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid-Connected Self-Synchronous Cascaded H-Bridge Inverters with Autonomous Power Sharing: Preprint

Cascaded inverters are widely applied in applications where elevated ac voltages are required while using semiconductor devices with lower voltage ratings. Here, we focus on structures that require localized power transfer between low-voltage sources/loads dispersed across inverter dc links and the inverter ac-sides are series-connected across a three-phase medium-voltage ac grid. To date, decentralized controllers that allow for bi-directional power transfer in such systems are limited. To fill this gap, we propose a virtual oscillator controller which modulates the power processed by each inverter in a purely decentralized manner.

autonomous power sharing↗

Grid-tied Multilevel Inverter with Phase-locked Loop Algorithm

A multilevel inverter is an electronic device capable of changing direct current energy to alternant current energy with a voltage and frequency established by the user. They are ideal for connecting renewable energy sources to the AC grid, energy plants, and smart grids. The voltage must be balanced and synchronized with the electrical network for adequate performance. This paper shows the voltage synchronization between an inverter output voltage and the AC grid using a phase-locked loop based on an adaptive observer. The proposed algorithm can perform under grid uncertainties such as noise and generates a reference signal for the modulation used in the inverter. The algorithm is robust and computationally efficient and can be implemented through basic elements such as operational amplifiers, resistors, and capacitors, reducing its difficulty in executing it in a system.

42 ENGINEERING↗