Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACOUSTIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SPT-3G D1: Axion early dark energy with CMB experiments and DESI observations

We present the most up-to-date constraints on axion early dark energy (AEDE) from cosmic microwave background (CMB) and baryon acoustic oscillation (BAO) measurements. In particular, we assess the impact of data from ground-based CMB experiments, the South Pole Telescope (SPT) and the Atacama Cosmology Telescope (ACT)—both with and without Planck—on constraints on AEDE. We also highlight the impact that BAO information from the Dark Energy Spectroscopic Instrument (DESI) has on these constraints. From CMB data alone, we do not find statistically significant evidence for the presence of AEDE, and we find only moderate reduction in the Hubble tension. From the latest SPT data alone, we find the maximal fractional contribution of AEDE to the cosmic energy budget is f EDE < 0.12 at 95% confidence level (CL), and the Hubble tension between the SPT and Supernovae, H0, for the Equation of State of Dark Energy (SH0ES) results is reduced to the 2.3 σ level. When combining the latest SPT, ACT, and Planck datasets, we find f EDE < 0.070 at 95% CL and the Hubble tension at the 3.6 σ level. In contrast, adding DESI data to the CMB datasets results in mild preference for AEDE and, in some cases, non-negligible reduction in the Hubble tension. From SPT + DESI , we find f EDE = 0.08 1 - 0.052 + 0.037 at 68% CL, and the Hubble tension reduces to 1.5 σ . From the combination of DESI with all three CMB experiments, we get f EDE = 0.05 5 - 0.047 + 0.024 at 68% CL and a weak preference for AEDE over Λ CDM . This data combination, in turn, reduces the Hubble tension to 2.6 σ . We highlight that this shift in parameters when adding the DESI dataset is a manifestation of the discrepancy currently present between DESI and CMB experiments in the concordance model Λ CDM .

Khalife, A. R. [Paris, Inst. Astrophys.] (ORCID:00↗

Cosmological implications of DESI DR2 BAO measurements in light of the latest ACT DR6 CMB data

We report cosmological results from the Dark Energy Spectroscopic Instrument (DESI) measurements of baryon acoustic oscillations (BAO) when combined with recent data from the Atacama Cosmology Telescope (ACT). By jointly analyzing ACT and Planck data and applying conservative cuts to overlapping multipole ranges, we assess how different 𝑃⁢𝑙⁢𝑎⁢𝑛⁢𝑐⁢𝑘 + ACT dataset combinations affect consistency with DESI. While ACT alone exhibits a tension with DESI exceeding 3⁢𝜎 within the Λ⁢ CDM model, this discrepancy is reduced when ACT is analyzed in combination with Planck. For our baseline DESI DR2 BAO + 𝑃⁢𝑙⁢𝑎⁢𝑛⁢𝑐⁢𝑘 P⁢R⁢4 + ACT likelihood combination, the preference for evolving dark energy over a cosmological constant is about 3⁢𝜎, increasing to over 4⁢𝜎 with the inclusion of type Ia supernova data. While the dark energy results remain quite consistent across various combinations of Planck and ACT likelihoods with those obtained by the DESI collaboration, the constraints on neutrino mass are more sensitive, ranging from ∑𝑚 𝜈 < 0.061 eV in our baseline analysis, to ∑𝑚 𝜈 < 0.077 eV (95% confidence level) in the CMB likelihood combination chosen by ACT when imposing the physical prior ∑𝑚 𝜈 > 0 eV.

79 ASTRONOMY AND ASTROPHYSICS↗

Irradiation Behavior of Piezoelectric Materials for Nuclear Reactor Sensors

In-situ measurement of surface acoustic wave (SAW) resonators were used to characterize piezoelectric materials behavior in a nuclear reactor environment. Lithium niobate and aluminum nitride devices were tested up to 500°C temperature and 450 kW reactor power (1.9x10 12 n/cm 2 s). The resonant frequency responds to step changes in temperature and power. Materials’ response are inferred from the observed resonant frequency changes, in particular the kinetic behavior is used to determine mechanisms responsible for observed changes. The observed response is attributed to two mechanisms: temperature increase from gamma heating and accumulation of radiation-induced defects. Both of these mechanisms alter the physical properties of the piezoelectric materials, particularly the elastic constants. The demonstrated repeatability and reliability of SAW devices are attractive for sensor applications in extreme environments.

36 MATERIALS SCIENCE↗

TEAMER – Enhanced Flow Measurement for Aquantis Tidal Turbine Test

The AQ10 is a floating, two-bladed, passive yawing tidal turbine developed by Aquantis that has a 10-meterrotor diameter, 160 kW rating, and employs reliable off-the-shelf powertrain and power conversion hardware. Aquantis is planning on-water turbine power performance and loads (blade loading and thrust)testing, where the turbine will be pushed through still water up to 4 knots and placed in a ‘station keeping’ tow in a tidal race up to its rated speed. On-water testing will be conducted using vessels and floating platforms on the sea surface to improve ease of testing and reduce disturbance to the environment. In this TEAMER project, Pacific Northwest National Laboratory (PNNL) will conduct water velocity and turbulence measurements in front of the turbine during on-water testing using acoustic Doppler instrumentation. By measuring both the tidal current flowing past the turbine and the resulting electrical power output, test results will provide a power curve (power vs flow speed) for the turbine up to rated power. Measurements of turbulence and velocity shear in front of the rotor will also provide information to assess the structural response of the rotor blades. With this analysis, Aquantis can use the performance and loads data to validate Tidal Bladed and OpenFAST simulations of the measured operating conditions. Measuring the power performance of a prototype turbine is a valuable step to improving device development and conducting a complete power performance assessment to IEC/TS 62600-200 standards in the future.

16 TIDAL AND WAVE POWER↗

Deep Learning of Dark Energy Spectroscopic Instrument Mock Spectra to Find Damped Lyα Systems

We have updated and applied a convolutional neural network (CNN) machine-learning model to discover and characterize damped Ly α systems (DLAs) based on Dark Energy Spectroscopic Instrument (DESI) mock spectra. We have optimized the training process and constructed a CNN model that yields a DLA classification accuracy above 99% for spectra that have signal-to-noise ratios (S/N) above 5 per pixel. The classification accuracy is the rate of correct classifications. This accuracy remains above 97% for lower S/N ≈1 spectra. This CNN model provides estimations for redshift and H i column density with standard deviations of 0.002 and 0.17 dex for spectra with S/N above 3 pixel -1 . Also, this DLA finder is able to identify overlapping DLAs and sub-DLAs. Further, the impact of different DLA catalogs on the measurement of baryon acoustic oscillations (BAO) is investigated. The cosmological fitting parameter result for BAO has less than 0.61% difference compared to analysis of the mock results with perfect knowledge of DLAs. This difference is lower than the statistical error for the first year estimated from the mock spectra: above 1.7%. We also compared the performances of the CNN and Gaussian Process (GP) models. Our improved CNN model has moderately 14% higher purity and 7% higher completeness than an older version of the GP code, for S/N > 3. Both codes provide good DLA redshift estimates, but the GP produces a better column density estimate by 24% less standard deviation. A credible DLA catalog for the DESI main survey can be provided by combining these two algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

DESI DR2 Results I: Baryon Acoustic Oscillations from the Lyman Alpha Forest

We present the Baryon Acoustic Oscillation (BAO) measurements with the Lyman-alpha (LyA) forest from the second data release (DR2) of the Dark Energy Spectroscopic Instrument (DESI) survey. Our BAO measurements include both the auto-correlation of the LyA forest absorption observed in the spectra of high-redshift quasars and the cross-correlation of the absorption with the quasar positions. The total sample size is approximately a factor of two larger than the DR1 dataset, with forest measurements in over 820,000 quasar spectra and the positions of over 1.2 million quasars. We describe several significant improvements to our analysis in this paper, and two supporting papers describe improvements to the synthetic datasets that we use for validation and how we identify damped LyA absorbers. Our main result is that we have measured the BAO scale with a statistical precision of 1.1% along and 1.3% transverse to the line of sight, for a combined precision of 0.65% on the isotropic BAO scale at $z_{eff} = 2.33$. This excellent precision, combined with recent theoretical studies of the BAO shift due to nonlinear growth, motivated us to include a systematic error term in LyA BAO analysis for the first time. We measure the ratios $D_H(z_{eff})/r_d = 8.632 \pm 0.098 \pm 0.026$ and $D_M(z_{eff})/r_d = 38.99 \pm 0.52 \pm 0.12$, where $D_H = c/H(z)$ is the Hubble distance, $D_M$ is the transverse comoving distance, $r_d$ is the sound horizon at the drag epoch, and we quote both the statistical and the theoretical systematic uncertainty. The companion paper presents the BAO measurements at lower redshifts from the same dataset and the cosmological interpretation.

79 ASTRONOMY AND ASTROPHYSICS↗

Pilot-Scale Validation of Distributed Optical Fiber Sensors for Underground Pipeline Monitoring

Distributed fiber optic sensing is a cutting-edge technology that has found extensive applications in the monitoring of Ensuring the safety, integrity, and operational efficiency of underground product pipelines is vital for maintaining the nation’s critical infrastructure. Monitoring parameters such as hoop strain, pressure, and acoustic vibrations is key to detecting potential leaks, intrusions, or structural issues. Distributed optical fiber sensor (DOFS) systems provide a compelling solution for continuous, real-time monitoring over long distances. This paper details the development and pilot-scale implementation of DOFS systems for underground pipeline monitoring, evolving from a proof-of-concept stage. Multiple custom-designed DOFS interrogator units—such as optical frequency-domain reflectometry (OFDR), Brillouin optical time-domain analysis (BOTDA), and multimodal interferometer-based fiber acoustic sensors—were employed to measure key parameters like hoop strain, pressure, and acoustic vibrations. The underground product pipeline's outer diameter is 30 inches, the wall thickness is 1.28 inches, and the 3-foot depth. The fiber deployment strategies, and sensing data acquisition methods for these systems are discussed. The results demonstrate the effectiveness of DOFS in detecting hoop strain, temperature changes, and acoustic vibrations, showcasing their potential for real-time monitoring and enhancing pipeline safety.

distributed fiber sensing↗

Clustering with general photo- z uncertainties: application to Baryon Acoustic Oscillations

ABSTRACT Photometric data can be analysed using the 3D correlation function ξp to extract cosmological information via e.g. measurement of the Baryon Acoustic Oscillations (BAO). Previous studies modeled ξp assuming a Gaussian photo-z approximation. In this work we improve the modeling by incorporating realistic photo-z distribution. We show that the position of the BAO scale in ξp is determined by the photo-z distribution and the Jacobian of the transformation. The latter diverges at the transverse scale of the separation s⊥, and it explains why ξp traces the underlying correlation function at s⊥, rather than s, when the photo-z uncertainty σz/(1+ z) ≳ 0.02. We also obtain the Gaussian covariance for ξp. Due to photo-z mixing, the covariance of ξp shows strong off-diagonal elements. The high correlation of the data causes some issues to the data fitting. None the less, we find that either it can be solved by suppressing the largest eigenvalues of the covariance or it is not directly related to the BAO. We test our BAO fitting pipeline using a set of mock catalogs. The data set is dedicated for Dark Energy Survey Year 3 (DES Y3) BAO analyses and includes realistic photo-z distributions. The theory template is in good agreement with mock measurement. Based on the DES Y3 mocks, ξp statistic is forecast to constrain the BAO shift parameter α to be 1.001 ± 0.023, which is well consistent with the corresponding constraint derived from the angular correlation function measurements. Thus, ξp offers a competitive alternative for the photometric data analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision measurements of EFT parameters and BAO peak shifts for the Lyman- α forest

We present precision measurements of the bias parameters of the one-loop power spectrum model of the Lyman- α (Ly- α ) forest, derived within the effective field theory (EFT) of large-scale structure. We fit our model to the three-dimensional flux power spectrum measured from the ACCEL 2 hydrodynamic simulations. The EFT model fits the data with an accuracy of below 2% up to k = 2 h Mpc − 1 . Further, we analytically derive how nonlinearities in the three-dimensional clustering of the Ly- α forest introduce biases in measurements of the baryon acoustic oscillations (BAOs) scaling parameters in radial and transverse directions. From our EFT parameter measurements, we obtain a theoretical error budget of Δ α ∥ = − 0.2 % ( Δ α ⊥ = − 0.3 % ) for the radial (transverse) parameters at redshift z = 2.0 . This corresponds to a shift of − 0.3 % (0.1%) for the isotropic (anisotropic) distance measurements. We provide an estimate for the shift of the BAO peak for Ly- α -quasar cross-correlation measurements assuming analytical and simulation-based scaling relations for the nonlinear quasar bias parameters resulting in a shift of − 0.2 % ( − 0.1 % ) for the radial (transverse) dilation parameters, respectively. This analysis emphasizes the robustness of Ly- α forest BAO measurements to the theory modeling. We provide informative priors and an error budget for measuring the BAO feature—a key science driver of the currently observing Dark Energy Spectroscopic Instrument (DESI). Our work paves the way for full-shape cosmological analyses of Ly- α forest data from DESI and upcoming surveys such as the Prime Focus Spectrograph, WEAVE-QSO, and 4MOST. Published by the American Physical Society 2025

de Belsunce, Roger (ORCID:0000000336604028)↗

Measurements of Density of Liquid Oxides with an Aero-Acoustic Levitator

Densities of liquid oxide melts with melting temperatures above 2000 °C are required to establish mixing models in the liquid state for thermodynamic modeling and advanced additive manufacturing and laser welding of ceramics. Accurate measurements of molten rare earth oxide density were recently reported from experiments with an electrostatic levitator on board the International Space Station. In this work, we present an approach to terrestrial measurements of density and thermal expansion of liquid oxides from high-speed videography using an aero-acoustic levitator with laser heating and machine vision algorithms. The following density values for liquid oxides at melting temperature were obtained: Y 2 O 3 4.6 ± 0.15; Yb 2 O 3 8.4 ± 0.2; Zr 0.9 Y 0.1 O 1.95 4.7 ± 0.2; Zr 0.95 Y 0.05 O 1.975 4.9 ± 0.2; HfO 2 8.2 ± 0.3 g/cm 3 . The accuracy of density and thermal expansion measurements can be improved by employing backlight illumination, spectropyrometry and a multi-emitter acoustic levitator.

36 MATERIALS SCIENCE↗

Overview of the Instrumentation for the Dark Energy Spectroscopic Instrument

Abstract The Dark Energy Spectroscopic Instrument (DESI) embarked on an ambitious 5 yr survey in 2021 May to explore the nature of dark energy with spectroscopic measurements of 40 million galaxies and quasars. DESI will determine precise redshifts and employ the baryon acoustic oscillation method to measure distances from the nearby universe to beyond redshift z > 3.5, and employ redshift space distortions to measure the growth of structure and probe potential modifications to general relativity. We describe the significant instrumentation we developed to conduct the DESI survey. This includes: a wide-field, 3.°2 diameter prime-focus corrector; a focal plane system with 5020 fiber positioners on the 0.812 m diameter, aspheric focal surface; 10 continuous, high-efficiency fiber cable bundles that connect the focal plane to the spectrographs; and 10 identical spectrographs. Each spectrograph employs a pair of dichroics to split the light into three channels that together record the light from 360–980 nm with a spectral resolution that ranges from 2000–5000. We describe the science requirements, their connection to the technical requirements, the management of the project, and interfaces between subsystems. DESI was installed at the 4 m Mayall Telescope at Kitt Peak National Observatory and has achieved all of its performance goals. Some performance highlights include an rms positioner accuracy of better than 0.″1 and a median signal-to-noise ratio of 7 of the [O ii ] doublet at 8 × 10 −17 erg s −1 cm −2 in 1000 s for galaxies at z = 1.4–1.6. We conclude with additional highlights from the on-sky validation and commissioning, key successes, and lessons learned.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging of surface acoustic waves on GaAs using 2D confocal Raman microscopy and atomic force microscopy

Surface acoustic wave devices have been fabricated on a GaAs (100) substrate to demonstrate the capability of 2D Raman microscopy as an imaging technique for acoustic waves on the surface of a piezoelectric substrate. Surface acoustic waves are generated using a two-port interdigitated transducer platform, which is modified to produce surface standing waves. We have derived an analytical model to relate Raman peak broadening to the near-surface strain field of the GaAs surface produced by the surface acoustic waves. Additionally, atomic force microscopy is used to confirm the presence of a standing acoustic wave, resolving a total vertical displacement of 3 nm at the antinode of the standing wave. Stress calculations are performed for both imaging techniques and are in good agreement, demonstrating the potential of this Raman analysis.

47 OTHER INSTRUMENTATION↗

Classification of Ultrasonic Weld Quality using Acoustic Signatures Acquired During Manufacture

Ultrasonic welding is a process is based on generating a solid-state bond between two metals by applying moderate pressure and high intensity sound waves (20-70 kHz frequencies) at their interface. During the solid-state process numerous material, surface, instrument, and environmental factors contribute to bond formation, strength, and durability. The inherent difficulty of measuring and controlling each of these factors has, to date, made predicting bond quality elusive. In this work, a Sonics model MWB20 ultrasonic spot welder with integral base, was used to produce a variety of welds of different metal foils under varying weld conditions. Acoustic measurements were recorded throughout the measurement process. Subsequent analysis of the signals using metrics that approximate the energy dispersed during the weld proved to successfully predict weld quality. Two metrics based on normalized energy differential and Renyi entropy were developed into Python and C++ scripts for direct analysis of weld acoustic data.

36 MATERIALS SCIENCE↗

Sensitivity measurements for a 250 MHz quartz shear-horizontal surface acoustic wave biosensor under liquid viscous loading

Surface acoustic wave (SAW) devices have been used in biochemical assays due to their high sensitivity. The device sensitivity is a function of changes in the density and viscosity of the liquid. Here, we studied the effect of fluid viscosity using a 250 MHz quartz shear-horizontal (SH)-SAW biosensor by monitoring different concentrations of binary aqueous/glycerol solutions. In this study, the sensitivity of the biosensor was determined by fitting the data to models derived from perturbation theory. Measurements in water were used as the reference. For a 0% to 50% glycerol solution, an 87°–204° separation in the phase shift was observed. The slope of the plot of the phase shift vs (ηρ)0.5 was used to indicate the sensor’s sensitivity. The sensitivity for our 250 MHz quartz SH-SAW sensors was calculated to be 3.7×10−3m2sKg. The corresponding mass sensitivity was determined to be 9.25 × 105m2Kg. The limit of detection was calculated to be 36 picograms (pg), while the limit of quantification or LOQ was calculated to be 109 pg. Traditionally, liquid phase measurements have been challenging for SAW devices because liquids dampen the vibrating sensors severely. This problem has been largely solved using a transverse (shear) wave instead of the more popular longitudinal or Rayleigh waves. Liquid measurements are now possible using transverse waves, also known as shear waves, because transverse waves are only minimally attenuated by liquids. Shear-horizontal SAW sensors (SH-SAW) show great promise as label-free biosensors because of their ability to handle liquid samples. However, the viscosity of the liquid still induces loading effects and can be measured when the liquid is loaded onto the SH-SAW propagating surface (delay line). When the liquid above the delay line is perturbed by physical or chemical changes, such as binding to a receptor, it alters the propagating acoustic wave. The SH-SAW device can measure these changes in liquid properties as a change in the wave’s phase compared to the original wave. The device’s phase shift was recorded as a function of the changes in the density and viscosity of the binary glycerol solution and used to determine the sensitivity in the linear dynamic range of responses.

Materials Science↗

Using SPT polarization, Planck 2015, and non-CMB data to constrain tilted spatially-flat and untilted nonflat ΛCDM, XCDM, and ΦCDM dark energy inflation cosmologies

We use six tilted spatially-flat and untilted non-flat dark energy cosmological models in analyses of South Pole Telescope polarization (SPTpol) cosmic microwave background (CMB) data, alone and in combination with Planck 2015 CMB data and non-CMB data, namely, the Pantheon Type Ia supernovae apparent magnitudes, a collection of baryon acoustic oscillation data points, Hubble parameter measurements, and growth rates. Although the cosmological models that best-fit the Planck CMB and non-CMB data do not provide good fits to the SPTpol data, with the χ2's exceeding the expected value, given the uncertainties, in each model the cosmological parameter constraints from the SPTpol data and from the Planck CMB and non-CMB data are largely mutually consistent. Furthermore, when the smaller angular scale SPTpol data are used jointly with either the Planck data alone or with the Planck CMB and the non-CMB data to constrain untilted non-flat models, spatially-closed models remain favored over their corresponding flat limits. When used in conjunction with Planck data, non-CMB data (baryon acoustic oscillation measurements in particular, from six experiments) have significantly more constraining power than the SPTpol data.

79 ASTRONOMY AND ASTROPHYSICS↗

Field validation of an actuated convergent-beam acoustic Doppler profiler for high resolution flow mapping

Abstract Energetic river and tidal flow environments feature complex hydrodynamic conditions. Conventional acoustic Doppler profiling instrumentation typically requires assumptions of flow homogeneity over the spatial scales of the divergent beam separation. This removes the ability to measure spatio-temporal variability within the flow. However, velocity variability within these spatial scales is often important in the design of structures and devices exposed to such flow, informing dynamic and peak hydrodynamic load predictions. The research presented outlines the development and testing of a flow measurement instrument consisting of multiple spatially-separated single beam acoustic Doppler profilers converging on a remote focal point, the location of which can be programmatically adjusted through actuation. This increases the spatial resolution at which remote field measurements can be made in energetic flow environments. Field testing of the instrument was conducted in a tidal channel at Sequim Bay Inlet, WA, USA. Results are compared with independent reference measurements made by a co-located, motion-corrected acoustic Doppler velocimeter. This comparison, across tidal velocities of 0.4–0.7 m s −1 , showed a mean velocity error of 0.5%–13.2% across nine sample locations within a 3.00 m × 2.25 m plane. To the authors’ knowledge, this is the first publication of flow velocity results from non-intrusive acoustic measurements at an off-axis, focal point location that features 3D positional control.

13 HYDRO ENERGY↗

Damage detection in a laboratory-scale wellbore applying Time Reversal and Nonlinear Elastic Wave Spectroscopy (TR NEWS)

We report Time Reversal and Nonlinear Elastic Wave Spectroscopy (TR-NEWS) has been used to focus acoustic energy, and make measurements correlated with damage in a variety of industrial materials. Most studies using TR-NEWS have focused on relatively small objects and may have multiple acoustic sources. In Earth, within energy extraction and carbon sequestration settings, the structure and scale of wellbores makes acoustic focusing challenging, as has been demonstrated through numerical simulations. This paper explores the feasibility of applying TR NEWS for damage detection in wellbores by constructing a laboratory-scale wellbore, and using TR to focus and make dynamic linear and nonlinear elastic measurements on it. During successive cycles of localized mechanical damage induced in the sample, the hysteretic nonlinear elastic parameter α increased with progressive mechanical damage. In addition to these strain-dependent changes in α, the width and peak amplitude of the time reversal focused energy changed near the damage site.

58 GEOSCIENCES↗

Physical Acoustics Characterization For Inspection and Evaluation

The area of acoustics and physics that studies interactions of acoustic waves with gaseous, liquid and/or solid media on macro- and microscales … to obtain the relevant information about a medium under consideration by measuring the properties of acoustic waves propagating through this medium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗