Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR FLOW - AIRFOILS - OSCILLATING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Water separator for hydrogen steam injected turbine engine

A propulsion system for an aircraft includes a core engine that includes a core flow path where air is compressed in a compressor section, communicated to a combustor section, mixed with a hydrogen based fuel and ignited to generate a core gas flow that is expanded through a turbine section. The propulsion system includes a hydrogen fuel system that is configured to supply hydrogen fuel to the combustor through a fuel flow path, a condenser that is arranged along the core flow path and configured to condense water within the core gas flow, and a separator that includes an inlet, a primary water outlet and an exit that includes a plurality of exit guide vanes for straightening the core gas flow that proceeds through the exit. The exit guide vanes include a secondary water outlet for removing condensed water in the core gas flow that proceeds through the exit.

Terwilliger, Neil J.↗

A study of velocity, temperature, and density in the plasma generated by laser-induced breakdowns

The paper presents velocity measurements of shock-induced flow field, leading to vortex generation and plasma deformation in air. Femtosecond-laser electronic excitation tagging (FLEET) velocimetry was performed at the times Δt = 3, 20, 50, and 100 µs post laser-induced breakdown. Emissions over Δt = 3–10 µs showed the propagations of the initially elliptic shock, transitioning into a spherical front. The shock emanated along the laser axis causes the flow outward, and then the pressure gradient generated by the rarefaction wave drives the inward flow at later moments, with the velocity magnitude approaching a steady-state value of 40 m s -1 . Temporal velocity evolution was compared with non-self-similar solutions behind the propagating shock, which are sensitive to the size of the energy deposition, and the use of the measured initial plasma diameter reproduced the experiment. There establishes a region of uniform velocity around 35 m s -1 in the air-flow running through the plasma, which triggers the roll-up of the plasma surface by a large-scale vortex, providing the detail of flow field evolution from the shock propagation to the plasma deformation. A collective Thomson scattering and hybrid fs/ps pure rotational coherent anti-Stokes Raman scattering (CARS) were also performed to gain insight into the high-temperature plasma. An effective electron–ion recombination rate of 2 x 10 -12 cm 3 s -1 was measured at Δt = 0.5–10 µs, during a dynamic plasma expansion and compression. When the shock resides close to the plasma at Δt = 0.5–1 µs, the temperature distributions were found to follow the similarity law.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient turbine engine using integrated ammonia fuel processing

A gas turbine engine includes a core engine that includes a core flow path where air is compressed in a compressor section, communicated to a combustor section, mixed with an ammonia based fuel and ignited to generate a high energy combusted gas flow that is expanded through a turbine section. The turbine section is mechanically coupled to drive the compressor section. An ammonia flow path communicates an ammonia flow to the combustor section. A cracking device is disposed in the ammonia flow path. The cracking device is configured to decompose the ammonia flow into a fuel flow containing hydrogen (H2). At least one heat exchanger is upstream of the cracking device that provides thermal communication between the ammonia flow and a working fluid flow such that the ammonia fluid flow accepts thermal energy from the working fluid flow.

Smith, Lance L.↗

Particulate matter sensor

Microfabricated PM sensors measure concentrations of particulate matter (PM) in air. Some sensors improve the accuracy of measurements by accounting for the effect of ambient conditions (e.g., temperature or humidity) on mass-sensitive elements employed to determine a mass of the PM in a stream of air. Some sensors improve the accuracy of measurements by controlling humidity in the stream of air measured by mass-sensitive elements. Some sensors employ a plurality of mass-sensitive elements to extend the useful life of the PM sensor. Some sensors employ one or more mass-sensitive elements and heating elements to cause deposition and allow measurement of different sizes of PM. Some sensors can measure mass concentration of coarse PM in addition to fine PM in a stream of air. Some sensors control the flow rate of a stream of air measured by mass-sensitive elements. Some sensors include features to mitigate electromagnetic interference or electromagnetic signal loss.

Paprotny, Igor↗

Broadband and filter radiometers at Ross Island, Antarctica: detection of cloud ice phase versus liquid water influences on shortwave and longwave radiation

Abstract. Surface radiometer data from Ross Island, Antarctica, collected during the austral summer 2015–2016 by the US Department of Energy Atmospheric Radiation Measurement (ARM) program West Antarctic Radiation Experiment (AWARE), are used to evaluate how shortwave and longwave irradiance respond to changing cloud properties as governed by contrasting meteorological regimes. Shortwave atmospheric transmittance is derived from pyranometer measurements, and cloud conservative-scattering optical depth is derived from filter radiometer measurements at 870 nm. With onshore flow associated with marine air masses, clouds contain mostly liquid water. With southerly flow over the Transantarctic Mountains, orographic forcing induces substantial cloud ice water content. These ice and mixed-phase clouds attenuate more surface shortwave irradiance than the maritime-influenced clouds and also emit less longwave irradiance due to colder cloud base temperature. These detected irradiance changes are in a range that can mean onset or inhibition of surface melt over ice shelves. This study demonstrates how basic and relatively low-cost broadband and filter radiometers can be used to detect subtle climatological influences of contrasting cloud microphysical properties at very remote locations.

54 ENVIRONMENTAL SCIENCES↗

Theoretical model of dielectrophoretic water vapor condensation during multiphase flow of electrically charged water droplets in air

Water droplet growth in air, influenced by vapor diffusion and electrical charging, has significant implications for indoor air quality, cloud formation, and aerosol dynamics. Here, this study presents a comprehensive theoretical model that describes the growth dynamics of electrically charged water droplets under external electric fields, incorporating diffusion, electrostatic, and dielectrophoretic forces to enhance understanding and practical applications in air dehumidification and environmental control. A theoretical model was established to analyze the growth dynamics of the charged water droplets. The approach extended the thermodynamic framework of the Modified Kelvin-Thomson equation by integrating electrostatic and dielectrophoretic effects, enabling a comprehensive evaluation of vapor concentration near the surface of charged droplets. A sensitivity analysis was performed to assess the roles of droplet size, electric field intensity, surface charge, and vapor concentration on condensation rates. The study progressed beyond the classical diffusion-limited growth of neutral droplets, addressing the behavior of charged droplets in electrohydrodynamic environments. The model highlighted the significance of dielectrophoretic drift flux for dipolar vapor molecules, especially in micron-sized droplets ranging from 10 to 100 µm. Findings demonstrated that, for smaller droplets subjected to elevated electrical charge, average growth rates varied from 0.3 to 1.6 µm/s if the air relative humidity increased from 50 to 100 %. Analytical results are corroborated by numerical simulations, which exhibited strong concordance, thereby validating the proposed theoretical approach. This research introduced an innovative and scalable analytical methodology for electric field-enhanced droplet growth, offering valuable insights into the advancement of energy-efficient air dehumidification, water desalination, and atmospheric water harvesting technologies.

42 ENGINEERING↗

Performance Analysis and Limiting Parameters of Cross-flow Membrane-based Liquid-desiccant Air Dehumidifiers

We report that to dehumidify a humid air stream, existing air conditioning (AC) systems substantially overcool the outdoor humid air below its dew point, thereby significantly reducing energy efficiency. Directly capturing humidity, membrane-based liquid-desiccant dehumidification systems separate sensible and latent cooling (SSLC) loads and thus offer a promising pathway for a high-performance AC solution. Design of an energy-efficient SSLC-AC system, however, rests largely on detailed understating of the dehumidification process. While some studies have identified the dehumidification process mainly depends on membrane characteristics, other studies have argued that the process is limited by desiccant liquid or alternatively air thermo-hydraulic physics for typical humid climate conditions. The present study examines performance and physics of the membrane-based liquid-desiccant dehumidification process over a wide range of climate conditions through a novel 3D, two-phase, multi-species CFD model. Decoupling the thermodynamic and hydraulic effects, the study reveals that the dehumidification rate is a linear function of the water vapor pressure potential ($J=α ΔP$) summarizing the system's thermodynamic state. The slope of the curve (i.e., α) depends on hydraulic transport characteristics of the membrane pores, air stream, and desiccant solution. More importantly, it was found that the air dehumidification process is mainly limited by the air-side transport physics for thin liquid-desiccant films and commonly used porous superhydrophobic membranes. Additionally, results show that, depending on ambient/desiccant conditions and physical dehumidifier characteristics, energy effectiveness and dehumidification rate vary from 13 to 34% and from 0.13 to 1.4 g m -2 s -1 , respectively. Therefore, the present study allows to efficiently design future SSLC-based AC systems exhibiting high performance energy metrics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Machine learning based prediction of airflow maldistribution in air-to-refrigerant heat exchangers

Flow maldistribution is a common challenge in heat exchanger (HX) design and particularly important for air-to-refrigerant geometries where capacity losses can approach 65%. This has a major impact on central air conditioning systems, as compact duct design motivates the use of A-type HXs which are known to be affected by airflow maldistribution. Because velocity profiles are difficult to predict, components are often oversized leading to increased material cost, system footprint, and refrigerant charge. Several studies detail airflow maldistribution for individual HXs and packages, but findings cannot always be extrapolated to new designs. In this work, a machine learning (ML) based flow profile prediction framework is developed and applied to two common package configurations: (i) A-type and (ii) U-type HXs, across a broad range of HX geometries and flow rates. Porous media CFD simulations are validated against independent data for both package types as well as comprehensive in house measurements for a finless geometry with shape optimized non-round tubes, which validates the framework for new heat transfer surfaces. The ML models are trained on the porous media CFD simulations, predicting volumetric flow rate (VFR) within 1.1% and 1.9% with maximum relative L 2 norm errors of 0.48 and 0.65, respectively, while also delivering 10 5 speed up factor compared to full porous media CFD. HX level simulations show an up to 9% reduction in heat transfer from flow maldistribution, with greater losses occurring at smaller half apex angles. This framework enables rapid and highly accurate prediction of airflow maldistribution induced capacity degradation.

42 ENGINEERING↗

Predictive Modeling of Local Film-Cooling Flow on a Turbine Rotor Blade

Abstract In the turbine section of a modern gas turbine engine, components exposed to the main gas path flow rely on cooling air to maintain hardware durability targets. Therefore, monitoring turbine cooling flow is essential to the diagnostic and prognostic efficacy of a condition-based operation and maintenance (CBOM) approach. This study supports CBOM goals by leveraging supervised machine learning to estimate relative changes to local film-cooling flowrate using surface temperature measured on the pressure side of a rotating turbine blade operating at engine-relevant aerothermal conditions. Throughout the lifetime of a film-cooled turbine component, characteristics of the film-cooling flow—such as film trajectory and cooling effectiveness—vary as degradation-driven geometry distortions occur, which ultimately affects the relationship between the model input and the model output—film-cooling flowrate predictions. The present study addresses this complication by testing a data-driven model on multiple turbine blades of the same nominal design, but with each blade exhibiting different localized film-cooling flow characteristics. By testing the model in this manner, strategies for mitigating the detrimental effects of film-cooling flow characteristic variations on model performance were investigated, and the corresponding flowrate prediction accuracy was quantified.

Engineering↗

Membrane-Based Air Dehumidification Using Organic Ionic Liquid Desiccant

Membrane Ionic Liquid Desiccant Air Dehumidification (MILDAD) is a promising alternative to conventional dehumidification systems that employ mechanical compressors and refrigerant-based cooling with evaporator and condensing coils. However, its application has been limited due to high manufacturing and installation cost, durability issues, concerns with corrosion due to leakage and salt carry over into the downstream air and onto surfaces. This paper reviews substantial progress made with new systems based on combining advanced ionic membranes that are pressure resistant, thin walled with high water permeability, and non-porous with synthetic organic, non-crystalline ionic liquid desiccants. Alternative design configurations are discussed comparing cross flow shell-and-tube membrane contactors employing ionic membrane tubes through which ionic liquid desiccant air flows. Performance data for MILDAD prototypes is provided. Dehumidification of the incoming supply airstream and regeneration into exhausted building air is demonstrated. The latent effectiveness of the MILDAD system will be discussed along with some future steps to improve performance of the system.

Bahar, Bamdad↗

Membrane-Based Air Dehumidification Using Organic Ionic Liquid Desiccant

Membrane Ionic Liquid Desiccant Air Dehumidification (MILDAD) is a promising alternative to conventional dehumidification systems that employ mechanical compressors and refrigerant-based cooling with evaporator and condensing coils. However, its application has been limited due to high manufacturing and installation cost, durability issues, concerns with corrosion due to leakage and salt carry over into the downstream air and onto surfaces. This paper reviews substantial progress made with new systems based on combining advanced ionic membranes that are pressure resistant, thin walled with high water permeability, and non-porous with synthetic organic, non-crystalline ionic liquid desiccants. Alternative design configurations are discussed comparing cross flow shell-and-tube membrane contactors employing ionic membrane tubes through which ionic liquid desiccant air flows. Performance data for MILDAD prototypes is provided. Dehumidification of the incoming supply airstream and regeneration into exhausted building air is demonstrated. The latent effectiveness of the MILDAD system will be discussed along with some future steps to improve performance of the system.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Combustor with dual pressure premixing nozzles

A combustor may include a combustor liner and flow sleeve. A high pressure air cools an outer surface of the combustor liner via openings in the flow sleeve, creating a lower pressure air in an annulus between the combustor liner and the flow sleeve. A first fuel nozzle is positioned at a primary combustion zone, and a second fuel nozzle is positioned at a secondary combustion zone of the liner. A fuel source is configured to deliver a fuel to the fuel nozzles. The fuel nozzles produce a premixture of high pressure air and the fuel, and produce a mixture of the premixture and the lower pressure air, prior to introducing the mixture to a respective primary or secondary combustion zone of the combustor. The combustor provides improved fuel premixing and is fuel flexible, and reduces pressure drop requirements. The combustor is usable in a can, annular, or segmented annular combustor assembly.

Berry, Jonathan Dwight↗

EPCAPE-PT-LANL Measurements: Single Particle Soot Photometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Single Particle Soot Photometer (Droplet Measurements Technology) Data Notes: Contact us if you want additional data products from this instrument. Reported data is the black carbon (rBC) number and mass concentration with diagnostic flags. The SP2 measures incandescence from particles that is induced with a 1064 Nd-YAG laser. Particles that absorb the laser energy and then emit radiation is assumed to contain black carbon. The amount of intensity of radiation is related to the mass of absorbing material in the particle. Here, we calibrate the incandescence intensity to size selected Regal Black (Cabot) nebulized from solution. Data provided for the EPCAPE campaign used the combined broadband high-gain + low-gain channels (BHBL). Each channel has a lower threshold of detection equivalent to 2-s of the respective channel noise. Thresholding has been applied to select between the high-gain and low-gain channels. The detection limit is 80-540 nm (Deq) or 0.36- 55 fg. It is assumed that rBC is the only aerosol type that is in significant concentration in the sampled atmosphere that absorbs the laser energy. Particle data are integrated over 10 second windows to calculate a rBC number and mass concentration. QC/QA: • Diagnostic flags that impacted measured concentration: - Sample, Sheath, and Purge Flow Rates: Despite observing fluctuations in all flows, the rBC detection and mass quantification are generally observed to be stable, although large changes in sample flow rate did impact detection efficiency. A flag was implemented for sample flow deviations >12 cm3/min from the set point averaged over 30 seconds - Laser Power: Detection efficiency decreases with laser power and deviations in laser power also affect mass quantification. Flag for laser power is set for deviations in laser current from the set value >5 mA. - Primary Detector Threshold: Primary thresholding is the signal value which determines whether a “particle” is recorded. Thresholding errors occur when the threshold value is too HIGH and real particles are ignored. • Several periods without data: - 16-18 Nov: Ultra Zero Air generator failure, flows deviated significantly from set points. rBC # conc recovered but questionable. - 20-21 Nov: Offline for calibrations for several hours each day. - 25-27 Nov: Data is missing. - 30 Nov: Power outage 3 Dec: SP2 hard-drive full. - 3 Dec: Power Outage Header: - BHBL_NumbConc[#/cc]: Refers to the number concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in particles per cubic centimeter. - BHBL_BCMass_Conc[ug/m3]: Refers to the mass concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in micrograms per cubic meter. - NoData_Flag[bool]: A boolean flag that indicates whether no data was recorded during a measurement. - NoBC_Flag[bool]: A boolean flag indicating whether no black carbon particles were recorded during the measurement. - Laser_Flag[bool]: A boolean flag indicating deviations in laser current during the measurement. - SampleFlow_Flag[bool]: A boolean flag indicating deviations from the set sample flow rate during the measurement. - PrimThresh_Flag[bool]: A boolean flag indicating deviations from the set primary threshold during the measurement, potentially ignoring real particles. - Manual_Flag[bool]: A boolean flag indicating manual intervention or adjustments during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active or inactive during the measurement.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of a Process to Separate Ensiled Corn Grain and Stover for Improved Utilization as a Biomass Feedstock

Corn grain and chopped stover were stored anaerobically at 37% to 50% (w.b.) aggregate moisture content to create a unique biomass feedstock. However, after storage, the two fractions must be separated to accommodate different conversion pathways. In this work, a modified cleaning system from a grain combine harvester was evaluated to investigate its effectiveness in separating the grain from the stover. While this system has been purposefully built for this task, there is no previous literature on separating grain at high material other than grain (MOG) to grain ratios. Using this system, material was separated into four fractions: Grain, Tailings, Heavy MOG, and Light MOG. Subsamples were collected, oven dried, and then hydrodynamically separated to quantify the grain content in the four fractions. Several different configurations of air velocities, mass flow rate, material MOG: grain ratios, and sieve types and openings were investigated. Grain capture was defined as the fraction of the total grain dry mass collected in the grain and tailings fractions. In five experiments, the grain capture effectiveness varied from 89.2% to 99.4% on a dry basis. The dry basis foreign matter (FM) in the clean grain was 0.6% to 10.8%. As a result, the use of a modified combine cleaning system has the potential to be one step in a system to fractionate corn grain from stover (i.e., MOG) in a biorefinery that uses both starch and cellulose as biomass feedstocks.

09 BIOMASS FUELS↗

Reformulation of dicamba herbicide: Impacts on offsite transport and soybean damage

Abstract The herbicide dicamba (3,6‐dichloro‐2‐methoxybenzoic acid) is commonly used to control broadleaf weeds in soybeans. Dicamba, however, is susceptible to volatilization and drift, thereby causing significant plant damage to nontarget crops downwind. Dicamba was reformulated to reduce volatility and off‐target movement. The effectiveness of the dicamba reformulation was assessed by quantifying dicamba emissions following spray application and investigated how meteorological factors influenced the off‐target movement. The experiments were conducted at the University of Minnesota Agricultural Experiment Station (UMORE Park) during the growing season of 2018, 2019, 2021, and 2022. Multiple high‐flow polyurethane foam air samplers were used to measure dicamba concentrations downwind from a 4‐ha soybean field sprayed with dicamba. Dicamba emissions were estimated using backward Lagrangian modeling constrained by the air sample observations. The results indicate that dicamba emissions and downwind transport were significant for several days following application. Further, non‐traited soybeans located within 15–45 m showed substantial dicamba‐related damage. In warmer, drier seasons, increased dicamba emissions caused more severe damage to downwind soybeans, likely worsened by drought stress preventing recovery. Favorable atmospheric conditions that reduced potential drift can be difficult to achieve in terms of the typical weather experienced over agricultural sites in the Upper Midwest. These results indicate that the dicamba reformulation has not adequately prevented significant post‐spray volatilization losses and downwind transport.

Agriculture↗

Coupling reduced‐order modeling and coarse‐grained CFD‐DEM to accelerate coal gasifier simulation and optimization

Abstract High fidelity three‐dimensional (3‐D) numerical simulations of commercial‐scale coal gasifiers are very time consuming and expensive. This article proposes a reduced‐order modeling approach that uses quasi one‐dimensional (1‐D) CFD–DEM simulation results to serve as an accurate initial condition for the 3‐D simulation, which significantly shortens the physical time from several hours to minutes to achieve steady states. The 3‐D simulation employs a previously validated coarse‐grained CFD‐DEM approach, which further accelerates the simulation. Both 1‐D and 3‐D simulations adopt a particle shrinkage scheme to correctly account for the particle volume change due to chemical reaction and thus provides an accurate bed height. Comparison with available experimental measurements of the bed temperature and synthesis gas composition is used to validate the simulation. The final syngas composition and flowrates are strongly affected by the fuel or gasification agent rate and process operating conditions as expected. This approach is then used to optimize two important operating conditions (air and steam flows) to achieve specific gasifier performance goals for the production of Fischer–Tropsch synthesis gas and production of fuel gas for gas turbines.

Yu, Jia↗

A minor respiratory process with major global implications: is atmospheric methane oxidation in tree stems driven by stem respiration rather than microbial methanotrophy?

Tree stem surfaces are widely recognized as sites of carbon dioxide (CO₂) efflux and oxygen (O₂) influx, reflecting the dynamics of aerobic respiration of photosynthate substrates, such as sugars, delivered via the phloem. Stems are also largely considered passive conduits for methane (CH₄) produced in anoxic soils via microbial methanogenesis, where CH₄ is thought to be transported upward through the transpiration stream and/or diffusion and emitted through stem surfaces and the canopy. However, recent observations from dynamic stem chambers suggest that stems may also act as active sinks for atmospheric CH₄. Despite these findings, the extent and drivers of stem CH₄ consumption remain poorly characterized across biomes, species, and environmental gradients, and its quantitative relationship to stem respiration has not been established. Moreover, previous studies captured only snapshot fluxes, leaving diurnal patterns of CH₄ exchange uncharacterized. Here, we address these limitations by combining real-time measurements of stem CH₄ and O₂ uptake under ambient conditions in a California cherry tree, using a dynamic stem gas exchange system with three chambers receiving a continuous flow of ambient air and automated chamber and reference air sampling every 10 min. Our results confirm that stems of upland trees can actively consume both atmospheric CH₄ and O₂, but with decreasing temperature sensitivity as daily temperatures increase. Early mornings were marked by rapid influxes of both gases, followed by declining uptake as temperatures rose further. Methane uptake was tightly coupled with O₂ influx and represented a minor (0.012% ± 0.002%) fraction of stem respiratory activity, as determined by concurrent O₂ uptake. These findings suggest that while atmospheric CH₄ oxidation is a minor respiratory process in stems, it is strongly linked with stem physiological activity. This challenges the current assumption that terrestrial CH₄ uptake is driven solely by microbial methanotrophy and raises the possibility that living stem tissues may contribute to CH₄ oxidation through an as-yet-unidentified plant-based mechanism.

Atmospheric greenhouse gases↗