Search NASA⌕ Search

SEARCH · Search NASA

Results for “APDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Performance of the GLAS Space Lidar Receiver Through Its Seven-Year Space Mission

NASA s Ice, Cloud, and land Elevation Satellite (ICESat) mission [1,2] carrying the Geoscience Laser Altimeter System (GLAS) Instrument, was launched on January 12, 2003. The three lasers on ICESat have made a total of 1.98 billion laser shot measurements of the Earth s surface and atmosphere during its 17 science data collection campaigns over its seven year operating lifetime. ICESat completed its science mission after the last laser stopped operating in October 2009. The spacecraft was de-orbited on August 30, 2010. The GLAS instrument carried 3 diode-pumped Q-switched Nd:YAG lasers, which emitted 6-nsec wide pulses at 1064 and 532 nm at a 40-Hz rate. There are three lidar receiver channels, a 1064 nm surface altimetry channel, a 1064 nm cloud backscattering lidar channel, and a 532 nm cloud and aerosol backscattering lidar channel. The altimetry and cloud backscatter channels used Si avalanche photodiode (APD) operated in analog mode as in the Mars Global Surveyor s Mars Orbital Laser Altimeter [3,4]. GLAS also utilized a number of new technologies and techniques for space lidar, including passively Q-switched diode-pumped Nd:YAG lasers, a 1-m diameter telescope, a temperature tuned etalon optical bandpass filter, Si APD single photon counting detectors, 1 Gsample/sec waveform digitizers, ultra stable clock oscillators, and digital signal processing and detection algorithms [5]. A global position system (GPS) receiver was used to provide the spacecraft position and epoch times. The ICESat mission provided a unique opportunity to monitor the lidar component performance in the space environment over a multi-year time period. We performed a number of engineering tests periodically to monitor the lidar receiver performance, including receiver sensitivity, timing precision, detector dark noise, etc. A series of engineering tests were also performed after the end of the science mission to evaluate the performance of the spare detector, oscillator, waveform digitizer, and GPS receiver. An experiment was conducted which pointed GLAS to Venus to test the receiver sensitivity to star light and to verify GLAS bore sight with respect to the spacecraft coordinate system. These tests provided unique data to assess the degradation and the rate of change of these key lidar components due to space radiation and aging. They also helped to validate new techniques to operate and calibrate future space lidars.

Sun, Xiaoli↗

Single Photon HgCdTe Avalanche Photodiode and Integrated Detector Cooler Assemblies for Space Lidar Applications

A linear mode photon counting HgCdTe avalanche photodiode (APD) focal plane array (FPA) detector was developed for space lidar applications. An integrated detector cooler assembly (IDCA) was manufactured using a miniature Stirling cooler. The HgCdTe APD demonstrated a greater than 60% photon detection efficiency from 0.9 to 4.3 μm wavelength and a dark count rate less than 250,000/s. The IDCA cooled the FPA to 110K from ambient room temperature at a total electrical power of 7 W. The IDCA has passed environmental tests, including vibration, thermal cycling and thermal vacuum tests.

Sun, Xiaoli↗

Development of High Performance Detector Technology for UV and Near IR Applications

Sensing and imaging for ultraviolet (UV) and nearinfrared (NIR) bands has many applications forNASA, defense, and commercial systems. Recentwork has involved developing UV avalanchephotodiode (UV-APD) arrays with high gain for highresolution imaging. Various GaN/AlGaN p-i-n (PIN)UV-APDs have been fabricated from epitaxialstructures grown by MOCVD on GaN substrates withavalanche gains higher than 5 x 10(exp 5), and significantlyhigher responsivities. Likewise, the SiGe materialsystem allows the demonstration of high-performancedetector array technology that covers the 0.5 to 1.7 mwavelength range for visible and NIR bands ofinterest. We have utilized SiGe fabrication technologyto develop Ge based PIN detector devices on 300 mmSi wafers. We will discuss the theoretical andexperimental results from electrical and opticalcharacterization of the detector devices with variousn+ region doping concentrations to demonstrate low dark currents below 1 uA at -1 V and high photocurrent. Recent results from these detectorarrays for UV and NIR detection will be presented.

IR↗

CHOMPTT (CubeSat Handling of Multisystem Precision Timing Transfer): From Concept to Launch Pad

Here we present the evolution of a student satellite mission: CHOMPTT (CubeSat Handling of Multisystem Precision Time Transfer), from its original concept as a candidate for the University NanoSatellite Program 8 (UNP8), to a spacecraft ready for launch in Fall of 2017 on ELaNa XIX (Educational Launch of Nanosatellites). The 3U CubeSat houses a 1 kg, 1U OPTI (Optical Precision Timing Instrument) payload, designed and built at the University of Florida, and a 1.5U EDSNNODeS-derived bus from NASA Ames Research Center. The OPTI payload comprises of: 1) a supervisor board that handles payload data, power regulation, and mode settings, 2) an optics assembly of six 1 cm retroreflectors and four laser beacon diodes for ground-tracking; and 3) two fully redundant timing channels, each consisting of: a chip-scale atomic clock, a microprocessor with clock counter, a picosecond event timer, and an avalanche photodetector (APD) with band-pass filter. Several iterations of OPTI have been developed, tested, and designed to achieve its current functionality and design a laboratory breadboard design, a 1.5U high altitude balloon design, engineering unit design, and its current flight unit design. In-lab testing of the current OPTI design indicates a short-term precision of 100 ps, equivalent to a range accuracy of 3 cm necessary to achieve our primary objective of 200 ps time transfer error, and a long-term timing accuracy of 20 ns over one orbit (1.5 hours). After the spacecraft reaches its nominal 500 km orbit at a 85 degree inclination, an experimental laser ranging facility at Kennedy Space Center in Florida, will track and emit 1064 nm nanosecond optical pulses at the CHOMPTT spacecraft. The laser pulses will then reflect off the retroreflector array mounted on the nadir face of CHOMPTT, and return the pulse to the laser ranging facility where the laser ranging facility will record the round-trip duration of the laser pulses. At the same time the pulse arrives at the spacecraft and is reflected by the array, an APD will record the arrival time of the pulses at the nanosatellite. By comparing the arrival of the pulse at the CubeSat and the duration of the round-trip of the laser pulse, the clock discrepancy between the ground and CubeSat atomic clocks can be determined, in addition to the CubeSats range from the facility. The design and verification of the flight version of CHOMPTT will be reviewed and an overview of the lifetime development and progression of CHOMPTT from the inception to launch pad will be presented.

CHOMPTT↗

The MERiT Onboard the CeREs: A Novel Instrument to Study Energetic Particles in the Earth's Radiation Belts

The Miniaturized Electron pRoton Telescope, MERiT, is a low‐mass, low‐power, compact instrument using an innovative combination of particle detectors, sensor electronics, and onboard processing. MERiT is flying on the Compact Radiation belt Explorer, CeREs, a 3U CubeSat launched into a low earth orbit of 500‐km altitude and inclination of 85° on 16 December 2018. The primary and secondary science goals of CeREs are to investigate electron microbursts and to study solar particles. MERiT comprises a stack of solid state detectors (SSD) behind space facing avalanche photo diodes (APDs) surrounded by W‐Al shielding to reduce side‐penetrating particle background. The APD‐SSD combination enables measurement of electrons from 5 to 200 keV and 1 to 8 MeV; protons from 200–400 keV and 7–100 MeV in differential channels with energy resolution ΔE/E≈30% for both electrons and protons. MERiT measures microbursts with a high time resolution ranging from 4 to 16 ms and solar particles with a cadence of 1 s. MERiT energy channels and cadences are software configurable via algorithms and lookup tables residing on a field‐programmable gate array. The lookup tables can be changed via ground commands. MERiT geometry factor is 31 sq.cm‐sr and optimized to measure microbursts with the instrument viewing the local zenith in orbit. MERiT enables investigation of dynamical processes of radiation belt electron energization and loss, solar electron and proton transport, and their access to the Earth's polar caps. We describe the MERiT sensor design, calibration, operational modes, data products, and science goals.

Kanekal, S. G.↗

A Decade of NASA Strategic Astrophysics Technology Investments: Technology Maturation, Infusion, and Other Benefits

NASA’s Astrophysics Division (APD) funds development of cutting-edge technology to enable its missions to achieve ambitious and groundbreaking science goals. These technology development efforts are managed by the Physics of the Cosmos (PCOS), Cosmic Origins (COR), and Exoplanet Exploration (ExE) Programs. The NASA Strategic Astrophysics Technology (SAT) Program was established in 2009 as a new technology maturation program to fill the gap in the Technology Readiness Level (TRL) range from 3 to 6. Since program inception, 100 SAT grants have been openly competed and awarded, along with dozens of direct-funded projects, leading to a host of technologies advancing their TRLs and/or being infused into space and suborbital missions and ground-based projects. We present the portfolio distribution in terms of specific technology areas addressed, including optics, detectors, coatings, coronagraphs, starshades, lasers, electronics, cooling systems, and micro-thruster subsystems. We show an analysis of the rate of TRL advances, infusion success stories, and other benefits such as training the future astrophysics workforce, including students and postdoctoral fellows hired by projects. Finally, we present APD’s current strategic technology maturation priorities for investment, enabling a range of future strategic astrophysics missions

NASA, astrophysics, technology development, optics↗

X-ray and gamma ray detector readout system

A readout electronics scheme is under development for high resolution, compact PET (positron emission tomography) imagers based on LSO (lutetium ortho-oxysilicate, Lu.sub.2SiO.sub.5) scintillator and avalanche photodiode (APD) arrays. The key is to obtain sufficient timing and energy resolution at a low power level, less than about 30 mW per channel, including all required functions. To this end, a simple leading edge level crossing discriminator is used, in combination with a transimpedance preamplifier. The APD used has a gain of order 1,000, and an output noise current of several pA/ Hz, allowing bipolar technology to be used instead of CMOS, for increased speed and power efficiency. A prototype of the preamplifier and discriminator has been constructed, achieving timing resolution of 1.5 ns FWHM, 2.7 ns full width at one tenth maximum, relative to an LSO/PMT detector, and an energy resolution of 13.6% FWHM at 511 keV, while operating at a power level of 22 mW per channel. Work is in progress towards integration of this preamplifier and discriminator with appropriate coincidence logic and amplitude measurement circuits in an ASIC suitable for a high resolution compact PET instrument. The detector system and/or ASIC can also be used for many other applications for medical to industrial imaging.

Tumer, Tumay O↗

Integration of a 6 LilnSe 2 thermal neutron detector into a CubeSat instrument

This paper describes the development of a preliminary compact and lightweight neutron detection system that uses the low power consuming CubeSat platform and will be especially effective for space-based applications. This is made possible using the novel 6 LiInSe 2 scintillator crystal and a silicon avalanche photodiode (Si-APD). The schematics of this instrument are presented as well as the response of the instrument to initial testing under alpha radiation. The entire system weighs 670 grams and requires 5 volts direct current at 3 watts.

36 MATERIALS SCIENCE↗

Identifying Patients Who Are Unsuitable for Accelerated Partial Breast Irradiation Using Three-dimensional External Beam Conformal Techniques

Purpose: Several recent studies reported that severe late toxicities including soft-tissue fibrosis and fat necrosis are present in patients treated with accelerated partial breast irradiation (APBI) and that these toxicities are associated with the large volume of tissue targeted by high-dose irradiation. The present study was performed to clarify which patients are unsuitable for APBI to avoid late severe toxicities. Methods and Materials: Study subjects comprised 50 consecutive patients with Stage 0-II unilateral breast cancer who underwent breast-conserving surgery, and in whom five or six surgical clips were placed during surgery. All patients were subsequently replanned using three-dimensional conformal radiotherapy (3D-CRT) APBI techniques according to the National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39 and Radiation Therapy Oncology Group (RTOG) 0413 protocol. The beam arrangements included mainly noncoplanar four- or five-field beams using 6-MV photons alone. Results: Dose-volume histogram (DVH) constraints for normal tissues according to the NSABP/RTOG protocol were satisfied in 39 patients (78%). Multivariate analysis revealed that only long craniocaudal clip distance (CCD) was correlated with nonoptimal DVH constraints (p = 0.02), but that pathological T stage, anteroposterior clip distance (APD), site of ipsilateral breast (IB) (right/left), location of the tumor (medial/lateral), and IB reference volume were not. DVH constraints were satisfied in 20% of patients with a long CCD ({>=}5.5 cm) and 92% of those with a short CCD (p < 0.0001). Median IB reference volume receiving {>=}50% of the prescribed dose (IB-V{sub 50}) of all patients was 49.0% (range, 31.4-68.6). Multivariate analysis revealed that only a long CCD was correlated with large IB-V{sub 50} (p < 0.0001), but other factors were not. Conclusion: Patients with long CCDs ({>=}5.5 cm) might be unsuitable for 3D-CRT APBI because of nonoptimal DVH constraints and large IB-V{sub 50}.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of novel Hamamatsu Multi Pixel Photon Counter (MPPC) arrays for the GlueX experiment

The novel Hamamatsu Multi Pixel Photon Counter Array S12045(X) is an array of 16 individual MPPCs (3x3 mm{sup 2}) (further in the paper MPPC array channel) each with 3600 G-APD (Geiger-mode Avalanche Photodiodes) pixels (50x50 [{micro}m{sup 2}]). Each MPPC in the array works with its individual reverse bias voltage mode (around 70 V). The paper summarizes the characterization process of MPPC arrays used in GlueX experiment (Hall D, Jefferson Lab). We studied the main features of each MPPC array channel for 2800 MPPC arrays at different temperatures. Two measurement stations were built to extract gain, breakdown voltage, photo detection efficiency (PDE), optical crosstalk and dark rate for each MPPC array channel. The hardware and the data analysis are described, which includes new analytical expressions to obtain the mean number of photo-electrons and optical crosstalk. The dynamical behavior of characterization parameters is presented as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and status of the Mu2e electromagnetic calorimeter

Here, the Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5×10 –17 after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF 2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D; studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface Reconstruction in Hydrated Amphiphilic Block Copolymer Thin Films Probed by Fluid Cell Atomic Force Microscopy

In many thin film materials, nuanced interplays of interfacial energies control the surface morphology and rearrangement. This work evaluates polymer−solvent interactions and solvent-driven surface reconstructions via ex situ and in situ fluid cell Atomic Force Microscopy (fc-AFM) analysis of amphiphilic block copolymer (BCP) thin films upon exposure to deionized (DI) water. We examine the differences in surface morphology, whole-film swelling, and force response in thin films of polystyrene-block-poly(ethylene oxide) (PS-b-PEO) and polystyrene- block-poly[(allyl glycidyl ether)-co-(ethylene oxide)] (PS-b- P[AGE-co-EO]) processed into standing-up cylinder morphologies perpendicular to a silicon substrate (⊥C). Using Amplitude Modulation AFM (AM-AFM) and Amplitude-Phase Distance (APD) force spectroscopy, this work probes the mechanoresponsive nature of the dynamic surface layers of these films, unveiling surface layer stratification and surface chain rearrangement via minimal tip−sample stimulation. To help rationalize the observed reconfigurations, the energetic driving forces were estimated using the harmonic mean approximations of interfacial energies. Given the nonionizable nature of the minority P(AGE-co-EO) block and the energetic driving forces for chain mobility, this work shows how the elimination of unfavorable PS−water interfaces drives chain rearrangement and coverage of the PS surface by chains of the hydrophilic block. This work highlights considerations for increasing the heterogeneity and complexity of BCP thin films via random blocks and how those changes to local interfacial energies may drive larger scale film morphology reconstructions, with broader implications for tuning interface hydrophilicity.

Copolymers↗

Detailed study of the influence of surface misorientation on the density of Anti-Phase Boundaries in 3C-SiC layers grown on (001) silicon

In this work we investigated the influence of the Si substrate misorientation and 3C-SiC film thickness on the density of Anti-Phase Boundaries, in order to better understand the mechanism of antiphase domain annihilation. The two highlights in our work are the utilization of [001] orientated Si on-axis wafer with spherical dimples, which gave us access to a continuum of off-cut angles (0 deg. to {approx}11 deg.) and directions, and the deposition of elongated silicon islands on the surface of 3C-SiC epilayers, which improved the detection of APDs by analysis of Scanning Electron Microscopy images. We found that for a given layer thickness the relative surface occupation of one domain increases with the off-cut angle value, leading to single domain film up to a certain angle. This critical value is reduced as the film is thickened.

36 MATERIALS SCIENCE↗

Development and performance of a suprathermal electron spectrometer to study auroral precipitations

The design, development, and performance of Medium-energy Electron SPectrometer (MESP), dedicated to the in situ observation of suprathermal electrons in the auroral ionosphere, are summarized in this paper. MESP employs a permanent magnet filter with a light tight structure to select electrons with proper energies guided to the detectors. A combination of two avalanche photodiodes and a large area solid-state detector (SSD) provided 46 total energy bins (1 keV resolution for 3−20 keV range for APDs, and 7 keV resolution for >20 keV range for SSDs). Multi-channel ultra-low power application-specific integrated circuits are also verified for the flight operation to read-out and analyze the detector signals. MESP was launched from Poker Flat Research Range on 3 March 2014 as a part of ground-to-rocket electrodynamics-electrons correlative experiment (GREECE) mission. MESP successfully measured the precipitating electrons from 3 to 120 keV in 120-ms time resolution and characterized the features of suprathermal distributions associated with auroral arcs throughout the flight. The measured electrons were showing the inverted-V type spectra, consistent with the past measurements. In addition, investigations of the suprathermal electron population indicated the existence of the energetic non-thermal distribution corresponding to the brightest aurora.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study on avalanche photodiode influence on heterodyne laser interferometer linearity

In the paper we analyze factors reducing the possible accuracy of the heterodyne laser interferometers. The analysis is performed for the avalanche-photodiode input stages but is in main points valid also for stages with other type of photodetectors. Instrumental error originating from optical, electronic and digital signal processing factors is taken into consideration. We stress factors which are critical and those which can be neglected at certain accuracy requirements. In the work we prove that it is possible to reduce errors of the laser instrument below 1 nm point for multiaxial APD based interferometers by precise control of incident optical power and the temperature of the photodiode.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

2D microspatial distribution uniformity of photon detection efficiency and crosstalk probability of multi-pixel photon counters

Two-dimensional (2D) microspatial distribution uniformity of photon detection efficiency (PDE) and optical crosstalk probability P{sub ct} of multi-pixel photon counters (MPPCs) is studied. The experimental results show that the 2D spatial distribution of P{sub ct} is obviously uneven, i.e. P{sub ct} is larger at the corners and edges of a single pixel in MPPCs, which suggest a higher electrical field in the depletion region of the pixel at the corners and edges. The nonuniformity of the 2D spatial distribution of PDE also become evident when the size of the pixels of MPPCs is small, which signifies higher nonuniformity of the electric field distribution in MPPCs with small pixel size. A method is proposed for characterization of the 2D electrical field spatial distribution uniformity in a single pixel of MPPCs, which can be used for guiding the optimisation of the fabrication process of MPPCs and their properties. This promising method can naturally be extended to any Geiger avalanche photodiodes (G-APDs) and their arrays. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Progress status for the Mu2e calorimeter system

The Mu2e experiment at FNAL aims to measure the charged-lepton flavor violating neutrinoless conversion of a negative muon into an electron. The conversion results in a monochromatic electron with an energy slightly below the muon rest mass (104.97 MeV). The calorimeter should confirm that the candidates reconstructed by the extremely precise tracker system are indeed conversion electrons while performing a powerful $\mu/e$ particle identification. Moreover, it should also provide a high level trigger for the experiment independently from the tracker system. The calorimeter should also be able to keep functionality in an environment where the background delivers a dose of ~ 10 krad/year in the hottest area and to work in the presence of 1 T axial magnetic field. These requirements translate in the design of a calorimeter with large acceptance, good energy resolution O(5%) and a reasonable position (time) resolution of ~<1 cm (<0.5ns). The baseline version of the calorimeter is composed by two disks of inner (outer) radius of 351 (660) mm filled by 1860 hexagonal $BaF_2$ crystals of 20 cm length. Each crystal is readout by two large area APD's. In this study, we summarize the experimental tests done so far as well as the simulation studies in the Mu2e environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗