Search NASA⌕ Search

SEARCH · Search NASA

Results for “APEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Design of a walking robot

Carnegie Mellon University's Autonomous Planetary Exploration Program (APEX) is currently building the Daedalus robot; a system capable of performing extended autonomous planetary exploration missions. Extended autonomy is an important capability because the continued exploration of the Moon, Mars and other solid bodies within the solar system will probably be carried out by autonomous robotic systems. There are a number of reasons for this - the most important of which are the high cost of placing a man in space, the high risk associated with human exploration and communication delays that make teleoperation infeasible. The Daedalus robot represents an evolutionary approach to robot mechanism design and software system architecture. Daedalus incorporates key features from a number of predecessor systems. Using previously proven technologies, the Apex project endeavors to encompass all of the capabilities necessary for robust planetary exploration. The Ambler, a six-legged walking machine was developed by CMU for demonstration of technologies required for planetary exploration. In its five years of life, the Ambler project brought major breakthroughs in various areas of robotic technology. Significant progress was made in: mechanism and control, by introducing a novel gait pattern (circulating gait) and use of orthogonal legs; perception, by developing sophisticated algorithms for map building; and planning, by developing and implementing the Task Control Architecture to coordinate tasks and control complex system functions. The APEX project is the successor of the Ambler project.

Whittaker, William↗

GPS as an orbit determination subsystems

This paper evaluates the use of Global Positioning System (GPS) receivers as a primary source of tracking data for low-Earth orbit satellites. GPS data is an alternative to using range, azimuth, elevation, and range-rate (RAER) data from the Air Force Satellite Control Network antennas, the Space Ground Link System (SGLS). This evaluation is applicable to missions such as Skipper, a joint U.S. and Russian atmosphere research mission, that will rely on a GPS receiver as a primary tracking data source. The Detachment 2, Space and Missile Systems Center's Test Support Complex (TSC) conducted the evaluation based on receiver data from the Space Test Experiment Platform Mission O (STEP-O) and Advanced Photovoltaic and Electronics Experiments (APEX) satellites. The TSC performed orbit reconstruction and prediction on the STEP-0 and APEX vehicles using GPS receiver navigation solution data, SGLS RAER data, and SGLS anglesonly (azimuth and elevation) data. For the STEP-O case, the navigation solution based orbits proved to be more accurate than SGLS RAER based orbits. For the APEX case, navigation solution based orbits proved to be less accurate than SGLS RAER based orbits for orbit prediction, and results for orbit reconstruction were inconclusive due to the lack of a precise truth orbit. After evaluating several different GPS data processing methods, the TSC concluded that using GPS navigation solution data is a viable alternative to using SGLS RAER data.

Fennessey, Richard↗

A Numerical Study of Low-Reynolds-Number Separation Bubbles

The present study uses two dimensional numerical simulations to study unsteady low-Reynolds-number separation bubbles. The numerical study is in two parts: (1) a two dimensional time-accurate Navier-Stokes solver is used to simulate flows over the APEX airfoil, and (2) a numerical procedure is developed for localized simulations of transitional separation bubbles. The 2-D computations of flow over the APEX airfoil show that the flow is unsteady with periodic vortex shedding. A linear stability analysis of the separated flow shows that the vortex shedding is caused due to the instability of the separated flow. For transonic flows over the APEX airfoil the vortex shedding is additionally influenced by the presence of shocks. The flowfield has two characteristic time scales, one corresponding to the vortex shedding and another corresponding to the movement of the shocks. The two dimensional (2-D) airfoil simulations also showed the presence of nonlinear effects in the separated region. To better understand the characteristics of separation bubbles a numerical procedure has been developed for localized separation bubble calculations. This procedure is used to perform computations for a flat plate separation bubble test case. The separation bubble is induced by specifying a velocity gradient in the freestream. The growth of disturbances in the separation bubble is analyzed by introducing disturbances upstream of the separation bubble.

Tatineni, Mahidhar↗

Differential Cratering of Synchronously Rotating Satellites by Ecliptic Comets

We use Monte Carlo methods to simulate impacts of ecliptic comets on the synchronously rotating satellites of giant planets. We reconfirm the long-standing prediction that the cratering rate should be much higher on the leading hemispheres than on the trailing hemisphere; indeed we find that previously published analytical formulations modestly underestimate the degree of apex-antapex asymmetry to be expected. We then compare our results to new mapping of impact craters on Ganymede, Callisto, and Triton. Ganymede reveals a pronounced apex-antapex asymmetry that is nonetheless much less than predicted. All of Triton's confirmed impact craters are clustered toward the apex of motion, far exceeding the predicted asymmetry. No asymmetry is observed on Callisto. In each case at least one of our basic assumptions must be wrong. Likely candidates include the following: (i) the surfaces of all but the most sparsely cratered satellites are saturated or nearly saturated with impact craters; (ii) these satellites have rotated nonsynchronously over geological time; (iii) most of the craters are made not by heliocentric (Sun-orbiting) comets and asteroids but rather by planetocentric (planet-orbiting) debris of indeterminate origin; or (iv) pathological endogenic resurfacing has created illusions of structure. Callisto's surface is readily classified as nearly saturated. Ganymede's bright terrains, although less heavily cratered than those of Callisto, can also be explained by crater densities approaching saturation on a world where endogenic processes were active. The leading alternative is nonsynchronous rotation, an explanation supported by the distribution of catenae (crater chains produced by impact of tidally disrupted comets). Triton's craters can be explained by planetocentric debris or by capricious resurfacing, but both hypotheses are inherently improbable.

Zahnle, Kevin↗

Defective secretion of mucilage is the cellular basis for agravitropism in primary roots of Zea mays cv. Ageotropic

Root caps of primary, secondary, and seminal roots of Z. mays cv. Kys secrete large amounts of mucilage and are in close contact with the root all along the root apex. These roots are strongly graviresponsive. Secondary and seminal roots of Z. mays cv. Ageotropic are also strongly graviresponsive. Similarly, their caps secrete mucilage and closely appress the root all along the root apex. However, primary roots of Z. mays cv. Ageotropic are non-responsive to gravity. Their caps secrete negligible amounts of mucilage and contact the root only at the extreme apex of the root along the calyptrogen. These roots become graviresponsive when their tips are coated with mucilage or mucilage-like materials. Peripheral cells of root caps of roots of Z. mays cv. Kys contain many dictyosomes associated with vesicles that migrate to and fuse with the plasmalemma. Root-cap cells of secondary and seminal (i.e. graviresponsive) roots of Z. mays cv. Ageotropic are similar to those of primary roots of Z. mays cv. Kys. However, root-cap cells of primary (i.e. non-graviresponsive) roots of Z. mays cv. Ageotropic have distended dictyosomal cisternae filled with an electron-dense, granular material. Large vesicles full of this material populate the cells and apparently do not fuse with the plasmalemma. Taken together, these results suggest that non-graviresponsiveness of primary roots of Z. mays cv. Ageotropic results from the lack of apoplastic continuity between the root and the periphery of the root cap. This is a result of negligible secretion of mucilage by cells along the edge of the root cap which, in turn, appears to be due to the malfunctioning of dictyosomes in these cells.

NASA Discipline Number 29-20↗

The Apollo Capsule Optimization for Improved Stability and Computational/Experimental Data Comparisons

Numerical optimization was employed on the Apollo Command Module to modify its external shape. The Apollo Command Module (CM) that was used on all NASA human space flights during the Apollo Space Program is stable and trimmed in an apex forward (alpha of approximately 40 to 80 degrees) position. This poses a safety risk if the CM separates from the launch tower during abort. Optimization was employed on the Apollo CM to remedy the undesirable stability characteristics of the configuration. Geometric shape changes were limited to axisymmetric modifications that altered the radius of the apex (R(sub A)), base radius (R(sub O)), corner radius (R(sub C)), and the cone half angle (theta), while the maximum diameter of the CM was held constant. The results of multipoint optimization on the CM indicated that the cross-range performance can be improved while maintaining robust apex-aft stability with a single trim point. Navier-Stokes computations were performed on the baseline and optimized configurations and confirmed the Euler-based optimization results. Euler Analysis of ten alternative CM vehicles with different values of the above four parameters are compared with the published experimental results of numerous wind tunnel tests during the late 1960's. These comparisons cover a wide Mach number range and a full 180-degree pitch range and show that the Euler methods are capable of fairly accurate force and moment computations and can separate the vehicle characteristics of these ten alternative configurations.

Cliff, Susan E.↗

A Comparison of Three Algorithms for Orion Drogue Parachute Release

The Orion Multi-Purpose Crew Vehicle is susceptible to ipping apex forward between drogue parachute release and main parachute in ation. A smart drogue release algorithm is required to select a drogue release condition that will not result in an apex forward main parachute deployment. The baseline algorithm is simple and elegant, but does not perform as well as desired in drogue failure cases. A simple modi cation to the baseline algorithm can improve performance, but can also sometimes fail to identify a good release condition. A new algorithm employing simpli ed rotational dynamics and a numeric predictor to minimize a rotational energy metric is proposed. A Monte Carlo analysis of a drogue failure scenario is used to compare the performance of the algorithms. The numeric predictor prevents more of the cases from ipping apex forward, and also results in an improvement in the capsule attitude at main bag extraction. The sensitivity of the numeric predictor to aerodynamic dispersions, errors in the navigated state, and execution rate is investigated, showing little degradation in performance.

Matz, Daniel A.↗

Force Measurements to Excavate Lightly Compacted Granular Lunar Soil Simulant GRC-3B

The Advanced Planetary Excavator (APEX) was used to measure the forces to dig in lightly compacted granular lunar soil simulant GRC-3B with a 21.6-cm wide bucket which has a 30° leading edge. Long linear digs at 10-cm depth and variable rake angle were conducted to determine the reproducibility of the soil preparation. Cone penetrometer tests measured the soil condition prior to each test. Linear trajectories at 10-cm depth with rake angles of 10, 20, and 30 degrees show horizontal force increased and vertical force decreased as rake angle increased. NASA Glenn’s excavation laboratory and the APEX provide the capability of repeatable excavation trajectories and consistent soil preparation. The APEX can provide both linear and arc trajectories to measure excavation forces required for a small rover pushing a blade or a bucket on the lunar surface. To determine scaling effects, the forces to excavate with different sized implements can be measured directly

Margaret P Proctor↗

Pyramidal space frame and associated methods

A space frame having a high torsional strength comprising a first square bipyramid and two planar structures extending outward from an apex of the first square bipyramid to form a "V" shape is disclosed. Some embodiments comprise a plurality of edge-sharing square bipyramids configured linearly, where the two planar structures contact apexes of all the square bipyramids. A plurality of bridging struts, apex struts, corner struts and optional internal bracing struts increase the strength and rigidity of the space frame. In an embodiment, the space frame supports a solar reflector, such as a parabolic solar reflector. Methods of fabricating and using the space frames are also disclosed.

14 SOLAR ENERGY↗

M3 Wave DMP/APEX WEC Laboratory Testing Content Model

Laboratory Testing Content Model of Hinsdale 1:5 testing of thirteen different APEX I and APEX II configurations in the Long Wave Flume with a 0.5m deep sediment bed and under 4 different wave conditions.

16 TIDAL AND WAVE POWER↗

XPRESS: eXascale PRogramming Environment and System Software, Final Report

The University of Oregon (UO) was a partner in the XPRESS project together with Sandia National Laboratories (SNL), Indiana University (IU), Lawrence Berkeley National Laboratory (LBL), Louisiana State University (LSU), Oak Ridge National Laboratory (ORNL), University of Houston (UH), and University of North Carolina (RENCI). UO's objective in the project was to develop "APEX (Asynchronous Performance Environment for eXascale)": performance measurement, analysis, feedback and control infrastructure to asynchronous tasking runtimes, specifically HPX (LSU) and HPX-5 (IU). During the project period, our efforts focused on the need to measure complex tasking models where the traditional instrumentation methods would not work due to an absent/meaningless call-path context and runtime control of task pre-emption and resumption, usually on a different operating system thread. In addition to the challenges of performance measurement, we developed a framework to provide information from all levels of the stack (hardware, operating system, runtime, application) to a feedback & control mechanism for controlling concurrency, task granularity, networking parameters, and other aspects of execution in order to improve execution performance, throughput and/or efficiency. UO demonstrated these developments on leading edge HPC machines at large scale, including a 2017 Gordon Bell submission in which APEX was used to optimize key bottlenecks in an astrophysics application. The following final report summarizes our accomplishments during the XPRESS project.

99 GENERAL AND MISCELLANEOUS↗

Preserved and variable spatial‐chemical changes of lipids across tomato leaves in response to central vein wounding reveals potential origin of linolenic acid in signal transduction cascade

Abstract Membrane lipids serve as substrates for the generation of numerous signaling lipids when plants are exposed to environmental stresses, and jasmonic acid, an oxidized product of 18‐carbon unsaturated fatty acids (e.g., linolenic acid), has been recognized as the essential signal in wound‐induced gene expression. Yet, the contribution of individual membrane lipids in linolenic acid generation is ill‐defined. In this work, we performed spatial lipidomic experiments to track lipid changes that occur locally at the sight of leaf injury to better understand the potential origin of linolenic and linoleic acids from individual membrane lipids. The central veins of tomato leaflets were crushed using surgical forceps, leaves were cryosectioned and analyzed by two orthogonal matrix‐assisted laser desorption/ionization mass spectrometry imaging platforms for insight into lipid spatial distribution. Significant changes in lipid composition are only observed 30 min after wounding, while after 60 min lipidome homeostasis has been re‐established. Phosphatidylcholines exhibit a variable pattern of spatial behavior in individual plants. Among lysolipids, lysophosphatidylcholines strongly co‐localize with the injured zone of wounded leaflets, while, for example, lysophosphatidylglycerol (LPG) (16:1) accumulated preferentially toward the apex in the injured zone of wounded leaflets. In contrast, two other LPGs (LPG [18:3] and LPG [18:2]) are depleted in the injured zone. Our high‐resolution co‐localization imaging analyses suggest that linolenic acids are predominantly released from PCs with 16_18 fatty acid composition along the entire leaf, while it seems that in the apex zone PG (16:1_18:3) significantly contributes to the linolenic acid pool. These results also indicate distinct localization and/or substrate preferences of phospholipase isoforms in leaf tissue.

59 BASIC BIOLOGICAL SCIENCES↗

An electron fixed target experiment to search for a new vector boson A' decaying to e + e -

We describe an experiment to search for a new vector boson A' with weak coupling alpha' > 6 x 10 –8 α to electrons (α' = e 2 /4π) in the mass range 65 MeV < m A' < 550 MeV. New vector bosons with such small couplings arise naturally from a small kinetic mixing of the "dark photon" A' with the photon -- one of the very few ways in which new forces can couple to the Standard Model -- and have received considerable attention as an explanation of various dark matter related anomalies. A' bosons are produced by radiation off an electron beam, and could appear as narrow resonances with small production cross-section in the trident e + e - spectrum. We summarize the experimental approach described in a proposal submitted to Jefferson Laboratory's PAC35, PR-10-009. This experiment, the A' Experiment (APEX), uses the electron beam of the Continuous Electron Beam Accelerator Facility at Jefferson Laboratory (CEBAF) at energies of ~1-4 GeV incident on 0.5-10% radiation length Tungsten wire mesh targets, and measures the resulting e+e- pairs to search for the A' using the High Resolution Spectrometer and the septum magnet in Hall A. With a ~1 month run, APEX will achieve very good sensitivity because the statistics of e+e- pairs will be ~10,000 times larger in the explored mass range than any previous search for the A' boson. These statistics and the excellent mass resolution of the spectrometers allow sensitivity to α'/α one to three orders of magnitude below current limits, in a region of parameter space of great theoretical and phenomenological interest. Similar experiments could also be performed at other facilities, such as the Mainz Microtron.

43 PARTICLE ACCELERATORS↗

Endovascular Treatment of Two Pseudoaneurysms Originating From the Left Ventricle

A 67-year-old woman resented with an acute type A aortic dissection, which was treated surgically with aortic valve replacement as a composite graft with reimplantation of the coronary arteries. At the end of surgery, a left-ventricular venting catheter was placed through the apex and closed with a buffered suture. Consecutive computed tomography (CT) examinations verified a growing apex pseudoaneurysm. Communication between the ventricle and the pseudoaneurysm was successfully closed with an Amplatz septal plug by the transfemoral route. Follow-up CT showed an additional pseudoaneurysm, which also was successfully closed using the same method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Apical sparing pattern of left ventricular myocardial {sup 99m}Tc-HMDP uptake in patients with transthyretin cardiac amyloidosis

Background: A decreased longitudinal strain in basal segments with a base-to-apex gradient has been described in patients with cardiac amyloidosis (CA). Objectives: Aim was to investigate the left ventricular (LV) regional distribution of early-phase {sup 99m}Tc-Hydroxymethylene diphosphonate ({sup 99m}Tc-HMDP) uptake in patients with transthyretin-related cardiac amyloidosis (TTR-CA). Methods: All patients underwent a whole-body planar {sup 99m}Tc-HMDP scintigraphy acquired at 10-min post-injection (early-phase) followed by a thorax SPECT/CT. The segmental uptake (expressed as % of maximal myocardial HMDP uptake) was investigated on the AHA 17-segment model and 3-segment model (basal, mid-cavity, apical). Results: Sixty-one TTR-CA patients were included of whom 29 were wild-type (wt-TTR-CA) and 32 had hereditary TTR-CA (m-TTR-CA). Early myocardial {sup 99m}Tc-HMDP uptake occurred in all TTR-CA. In all patients, segmental analysis of the LV myocardial distribution of {sup 99m}Tc-HMDP uptake showed an increased median uptake (interquartile range) in basal/mid-cavity segments compared to the lowest median uptake of apical segments (respectively, 79% [72%-86%] vs. 72% [64%-81%]; P < 10{sup −6}). This pattern was similar in wt-TTR-CA group (78% [70%-84%] vs. 70% [61%-81%]; P < 10{sup −6}), in m-TTR-CA group (80% [74%-86%] vs. 73 [66%-82%]; P < 10{sup −7}) and remained constant independently of the TTR mutation subtype with P ranging 10{sup −5} to 0.03. Conclusions: Early-phase myocardial scintigraphy identified regional distribution of {sup 99m}Tc-HMDP uptake characterized by a base-to-apex gradient, corroborating echocardiographic, and cardiac magnetic resonance findings. This apical sparing pattern was similar across TTR-CA and TTR mutation subtypes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of micro-fin tube geometry parameters on evaporator material savings

A Performance Evaluation Criteria (PEC) analysis is presented that explores the influence of the micro-fin tube geometry on the required material volume. The analysis was done using a local flow boiling model, which can quantify the effect of fin parameters and the tube diameter. The PEC was done while requiring that the compared surfaces satisfy the same heat duty and pressure drop. The following tube parameters and ranges were explored: tube diameter (3 mm ≤ D o ≤ 6 mm), fin base thickness (0.12 mm ≤ t bf ≤ 0.29 mm), helix angle (6° ≤ α ≤ 30°), fin apex angle (11° ≤ β ≤ 22°), total number of fins (43 ≤ n f ≤ 70), and the fin height (0.11 mm ≤ e ≤ 0.3 mm). The tube that provided the smallest material requirements within the examined parameter ranges had: D o = 3 mm, t bf = 0.12 mm, α = 6°, β = 11°, n f = 43, and e = 0.3 mm. In general, small D o and t bf and large n f and e provided the best performance and work to minimize the required material volume to provide a given heat duty and pressure drop. The helix and the fin-tip apex angles were found to have very little influence on the performance for the examined range of parameters and angles associated with the lowest production cost should be chosen.

Evaporation↗

Radiographic and Anatomic Basis for Prostate Contouring Errors and Methods to Improve Prostate Contouring Accuracy

Purpose: Use of highly conformal radiation for prostate cancer can lead to both overtreatment of surrounding normal tissues and undertreatment of the prostate itself. In this retrospective study we analyzed the radiographic and anatomic basis of common errors in computed tomography (CT) contouring and suggest methods to correct them. Methods and Materials: Three hundred patients with prostate cancer underwent CT and magnetic resonance imaging (MRI). The prostate was delineated independently on the data sets. CT and MRI contours were compared by use of deformable registration. Errors in target delineation were analyzed and methods to avoid such errors detailed. Results: Contouring errors were identified at the prostatic apex, mid gland, and base on CT. At the apex, the genitourinary diaphragm, rectum, and anterior fascia contribute to overestimation. At the mid prostate, the anterior and lateral fasciae contribute to overestimation. At the base, the bladder and anterior fascia contribute to anterior overestimation. Transition zone hypertrophy and bladder neck variability contribute to errors of overestimation and underestimation at the superior base, whereas variable prostate-to-seminal vesicle relationships with prostate hypertrophy contribute to contouring errors at the posterior base. Conclusions: Most CT contouring errors can be detected by (1) inspection of a lateral view of prostate contours to detect projection from the expected globular form and (2) recognition of anatomic structures (genitourinary diaphragm) on the CT scans that are clearly visible on MRI. This study shows that many CT prostate contouring errors can be improved without direct incorporation of MRI data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effectiveness of Using Fewer Implanted Fiducial Markers for Prostate Target Alignment

Purpose: To evaluate the impact of the number and location of intraprostatic fiducial markers on the accuracy and reproducibility of daily prostate target alignment and to evaluate the migration of such markers. Methods and Materials: Three gold fiducial markers were implanted transrectally under ultrasound guidance near the apex, middle, and base of the prostate in 10 prostate cancer patients. The patients had pretreatment in-room computed tomography (CT) scans three times a week, for approximately 25 CT scans per patient during the 8-week treatment course. A total of 1280 alignments were performed using different alignment scenarios: whole-prostate soft tissue alignment (the gold standard), bone alignment, and seven permutations of alignments using one, two, or three fiducial markers. The results of bone alignment and fiducial alignment were compared with the results of whole-prostate alignment. Fiducial migration was also evaluated. Results: Single-fiducial-marker alignment was more accurate and reproducible than bone alignment. However, due to organ deformation, single fiducial markers did not always reliably represent the position of the entire prostate. The use of two-fiducial combinations was more accurate and reproducible than single-fiducial alignment, and use of all three fiducials was the best. Use of an apex fiducial together with a base fiducial rivaled the use of all three fiducials markers together. Fiducial migration was minimal. Conclusions: The number and the location of implanted fiducial markers affect the accuracy and reliability of daily prostate target alignment. The use of two or more fiducial markers is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗