Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerating cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Theoretical estimates of maximum fields in superconducting resonant radio frequency cavities: stability theory, disorder, and laminates

Theoretical limits to the performance of superconductors in high magnetic fields parallel to their surfaces are of key relevance to current and future accelerating cavities, especially those made of new higher-Tc materials such as Nb$_3$Sn, NbN, and MgB$_2$. Indeed, beyond the so-called superheating field $H_{\mathcal{sh}}$, flux will spontaneously penetrate even a perfect superconducting surface and ruin the performance. We present intuitive arguments and simple estimates for $H_{\mathcal{sh}}$, and combine them with our previous rigorous calculations, which we summarize. We briefly discuss experimental measurements of the superheating field, comparing to our estimates. We explore the effects of materials anisotropy and the danger of disorder in nucleating vortex entry. Will we need to control surface orientation in the layered compound MgB$_2$? Can we estimate theoretically whether dirt and defects make these new materials fundamentally more challenging to optimize than niobium? Finally, we discuss and analyze recent proposals to use thin superconducting layers or laminates to enhance the performance of superconducting cavities. As a result, flux entering a laminate can lead to so-called pancake vortices; we consider the physics of the dislocation motion and potential re-annihilation or stabilization of these vortices after their entry.

43 PARTICLE ACCELERATORS↗

Pushing the Gradient Limitations of Superconducting Photonic Band Gap Structure Cells

Superconducting photonic band gap resonators present us with unique means to place higher order mode couples in an accelerating cavity and efficiently extract HOMs. An SRF PBG resonator with round rods was successfully tested at LANL demonstrating operation at 15 MV/m. Gradient in the SRF PBG resonator was limited by magnetic quench. To increase the quench threshold in PBG resonators one must design the new geometry with lower surface magnetic fields and preserve the resonator's effectiveness for HOM suppression. The main objective of this research is to push the limits for the high-gradient operation of SRF PBG cavities. A NCRF PBG cavity technology is established. The proof-of-principle operation of SRF PBG cavities is demonstrated. SRF PBG resonators are effective for outcoupling HOMs. PBG technology can significantly reduce the size of SRF accelerators and increase brightness for future FELs.

43 PARTICLE ACCELERATORS↗

SRF niobium characterization using SIMS and FIB-TEM

Our understanding of superconducting radio frequency (SRF) accelerator cavities has been improved by elemental analysis at high depth resolution and by high magnification microscopy. This paper summarizes the technique development and the results obtained on poly-crystalline, large grain, and single crystal SRF niobium. Focused ion beam made possible sample preparation using transmission electron microscopy and the images obtained showed a very uniform oxide layer for all samples analyzed. Secondary ion mass spectrometry indicated the presence of a high concentration of hydrogen and the hydrogen content exhibited a relationship with improvement in performance. Depth profiles of carbon, nitrogen, and oxygen did not show major differences with heat treatment. Niobium oxide less than 10 nm thick was shown to be an effective hydrogen barrier. Niobium with titanium contamination showed unexpected performance improvement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

4 K SRF Operation of the 10 MeV CEBAF Photo-Injector

Superconducting radio-frequency (SRF) accelerating cavities are often operated in superfluid liquid helium with temperature near 2 K to enhance the cavity quality factor Q0 and to help manage heat loads, which are particularly important at large SRF accelerator facilities. This 2 K temperature paradigm, however, need not put SRF technology out of the reach of small institutions or even limit SRF operation at large facilities that need 10-100 MeV beam energy. At the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab there are regularly scheduled maintenance periods during which cryogenic plant often increases the liquid helium temperature from 2 K to 4 K, reducing power consumption by ~ 50 % and saving megawatts of wall-plug power. During recent maintenance periods, we accelerated a continuous-wave electron beam at the CEBAF photo-injector to a total energy of 6.3 MeV at currents up to 80 uA using two 5-cell niobium cavities in the quarter-cryomodule at 4 K. This contribution describes the SRF and cryogenic performance and uses measured beam quality and energy stability as key metrics. These measurements indicate that 4 K operation of niobium SRF cavities in CEBAF is a sensible and cost effective mode for high quality beam operation, provided the cryogenic load associated with lower Q0 is manageable for the number of cavities needed to operate. For Jefferson Lab, this enhances our scientific reach allowing additional low-energy ~ 10 MeV experiments each year.

Drury, Michael↗

Fast Beam Tuning for Accelerator Driven Systems

The biggest challenge for Accelerator Driven Systems (ADS) is the stringent availability requirement of >99% compared to ~80% achieved by a typical accelerators. In addition to overall availability, due to thermal stress problems, ADS is also sensitive to the length of each downtime. A significant source of downtime is re-adjustment tuning of the system to account for drift in component behavior, or substitution of a backup device for one that failed. Tuning at present is done by hand, i.e. with human observation, interpretation, and decision, a process which takes hours; whereas ADS requires recovery in minutes. In this research, we apply intelligent controls in a (simulated) proton linac to automate fine-tuning. Beam monitor data is fed into a controller which adjusts magnet currents and RF power to minimize beam loss. We consider fluctuations in ion source characteristics; drift in magnet behavior (mechanical motion, or change in calibration); and failure of an accelerating cavity.

43 PARTICLE ACCELERATORS↗

Gap Voltage Feed Forward Board for PEP II Low Level RF System

This paper describes the Gap Voltage Feed-Forward VXI module used in the PEP-II Low Level RF System. This module produces adaptively generated inphase (I) and quadrature (Q) reference signals for a single RF station based on measurements of periodic (1-turn) beam induced cavity transients caused by the presence of an ion clearing gap. In addition the module receives a fiber optically transmitted, bandlimited 'kic' signal from the longitudinal feedback system which is used to phase modulate the RF drive. This allows the RF system to act as a 'subwoofer' for the longitudinal feedback system for low order coupled-bunch instabilities driven by the fundamental mode of the accelerating cavities. The module includes hardware for remote measurement and adjustment of the 'kick' transfer function.

43 PARTICLE ACCELERATORS↗

Booster cavity damper redesign for PIP-II

A new Higher Order Mode (HOM) damper was designed and is undergoing testing for the Booster accelerator cavity at Fermilab. In anticipation of the PIP-II upgrade, it was discovered that the higher intensity of PIP-II may cause beam instability due to an excited mode at 106 MHz. This unfortunately corresponds with the cavity’s 2nd order harmonic mode, which will sweep from 86-105.7 MHz. The new damper is a modification of an existing damper that was designed to reduce an existing static HOM at 83 MHz, with the new design intending to cover the 2nd order HOM as well. The existing damper uses an inductive coupling loop to extract RF energy from the cavity which then goes through a filter in order to reflect the fundamental frequency back into the cavity while passing HOMs to a dump load. The new damper intends to replace the filter portion of the system with a wider band variant while also changing the topology from a coaxial cable loop filter to a componentized PCB-based design. Primary design challenges include bandwidth coverage, impedance matching of the various modes, long term thermal and mechanical stability, radiation hardness, and high voltage handling. Initial designs achieved the desired damping but were found to quickly succumb to destructive arcing due to the voltages present. More finalized designs intend to address this problem through circuit design modifications as well as the use of hardier components.

Pieper, Dustin [Fermilab]↗

Measurements of the Properties of Garnet Material for Tuning a 2nd Harmonic Cavity for the Fermilab Booster

A perpendicularly biased 2nd harmonic cavity is being designed and built for the Fermilab Booster, to help with injection and extraction. Tunable accelerating cavities were previously designed and prototyped at LANL, TRIUMF, and SSCL for use at 45-60 MHz (LANL at 50-84 MHz). The required frequency range for FNAL is 76 - 106 MHz. The garnet material chosen for the tuner is AL-800. To reliably model the cavity, its static permeability and loss tangent must be well known. As this information is not supplied by the vendor or in publications of previous studies, a first order evaluation of these properties was made using material samples. This paper summarizes the results of the corresponding measurements

43 PARTICLE ACCELERATORS↗

Cryogenic rf test of the first SRF cavity etched in an rf Ar/Cl 2 plasma

An apparatus and a method for etching of the inner surfaces of superconducting radio frequency (SRF) accelerator cavities are described. The apparatus is based on the reactive ion etching performed in an Ar/Cl 2 cylindrical capacitive discharge with reversed asymmetry. To test the effect of the plasma etching on the cavity rf performance, a 1497 MHz single cell SRF cavity was used. The single cell cavity was mechanically polished and buffer chemically etched and then rf tested at cryogenic temperatures to provide a baseline characterization. The cavity’s inner wall was then exposed to the capacitive discharge in a mixture of Argon and Chlorine. The inner wall acted as the grounded electrode, while kept at elevated temperature. The processing was accomplished by axially moving the dc-biased, corrugated inner electrode and the gas flow inlet in a step-wise manner to establish a sequence of longitudinally segmented discharges. The cavity was then tested in a standard vertical test stand at cryogenic temperatures. The rf tests and surface condition results, including the electron field emission elimination, are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nature and implication of found actual particulates on the inner surface of cavities in a full-scale cryomodule previously operated with beam

Field emission in an SRF cavity is often the result of small foreign particulates lodging on the cavity inner surface. To avoid these particulate field emitters, careful cleaning and handling of individual cavities and clean room assembly of cavity strings are common practice. Despite these elaborate processes, some particulates persist to stay on the final surface of a beam-ready cavity. Moreover, as will be shown in this contribution, new particulates accumulate after a cryomodule is placed in the accelerator tunnel. The nature of these accumulated particulates on the inner surface of a beam-accelerating cavity is largely unknown for two reasons: (1) lack of access to such surfaces; (2) lack of a workable procedure for investigation without destroying the cavity. In this contribution, we report the first study on found actual particulates on the inner surface of 5-cell CEBAF cavities in a full-scale cryomodule previously operated with beam. The nature of the studied particulates is presented. The implication of the findings will be discussed in view of reliable and efficient operation of CEBAF and future large-scale SRF accelerators.

Geng, Rongli↗

Simulation of the dynamics of gas mixtures during plasma processing in the C75 Cavity

Plasma processing using a mixture of noble gas and oxygen is a technique that is currently being used to reduce field emission and multipacting in accelerating cavities. Plasma is created inside the cavity when the gas mixture is exposed to an electromagnetic field that is generated by applying RF power through the fundamental power or higher-order mode couplers. Oxygen ions and atomic oxygen are created in the plasma which breaks down the hydrocarbons on the surface of the cavity and the residuals from this process are removed as part of the process gas flow. Removal of hydrocarbons from the surface increases the work function and reduces the secondary emission coefficient. This work describes the initial results of plasma simulation, which provides insight into the ignition process, distribution of different species, and interactions of free oxygen and oxygen ions with the cavity surfaces. The simulations have been done with an Ar/?2 plasma using COMSOL® multiphysics. These simulations help in understanding the dynamics and control of plasma inside the cavity and the exploration of different gas mixtures.

Dhakal, Pashupati↗

Wake fields effects for the eRHIC project

An Energy Recovery Linac (ERL) with a high peak electron bunch current is proposed for the Electron-Ion collider (eRHIC) project at the Brookhaven National Laboratory. The present design is based on the multi-pass electron beam transport in existing tunnel of the Relativistic Heavy Ion Collider (RHIC). As a result of a high peak current and a very long beam transport, consideration of various collective beam dynamics effects becomes important. Here we summarize effects of the coherent synchrotron radiation, resistive wall, accelerating cavities and wall roughness on the resulting energy spread and energy loss for several scenarios of the eRHIC project.

43 PARTICLE ACCELERATORS↗

Fabrication Studies for a Cylindrical DDS Structure at 90 GHz

A natural extension of work on the next generation of high power RF sources and accelerating cavities for Linear Colliders implies cylindrical, damped, detuned structures for millimeter wavelengths. Commercial availability of WR-10 waveguides and other components in the 75-110 GHz range provides a practical goal. Fabrication methods are surveyed, compared and, in some cases, tested to determine whether they can provide the imposed tolerances. Different techniques and tolerances are compared to previous methods at longer wavelengths. The higher gradients and corresponding surface fields indicate that a better understanding of the surface physics is required as well as how the different fabrication steps influence those surface characteristics that impact the final operation. We consider existing systems at SLAC and elsewhere as a function of frequency to determine what is desirable to measure and control for all phases of the fabrication, testing, conditioning and use of these systems. For example, the importance of crystal structure to the different steps is discussed. The preferred method allows a variety of design alternatives to be pursued simultaneously and extends to shorter wavelengths as well as provides possibilities for embedded test and control elements.

43 PARTICLE ACCELERATORS↗

Perpendicular Biased Ferrite Tuned Cavities for the Fermilab Booster

The aging Fermilab Booster RF system needs an upgrade to support future experimental program. The important feature of the upgrade is substantial enhancement of the requirements for the accelerating cavities. The new requirements include enlargement of the cavity beam pipe aperture, increase of the cavity voltage and increase in the repetition rate. The modification of the present traditional parallel biased ferrite cavities is rather challenging. An alternative to rebuilding the present Fermilab Booster RF cavities is to design and construct new perpendicular biased RF cavities, which potentially offer a number of advantages. An evaluation and a preliminary design of the perpendicular biased ferrite tuned cavities for the Fermilab Booster upgrade is described in the paper. Also it is desirable for better Booster performance to improve the capture of beam in the Booster during injection and at the start of the ramp. One possible way to do that is to flatten the bucket by introducing second harmonic cavities into the Booster. This paper also looks into the option of using perpendicularly biased ferrite tuners for the second harmonic cavities.

43 PARTICLE ACCELERATORS↗

A novel approach to RF power coupling in Radio-Frequency Quadrupole (RFQ) structures: built-in coaxial double-loop coupling port

Efficient and reliable RF power couplers in accelerating cavities require precise impedance matching and mechanical stability to ensure optimal beam energy transfer. In radio-frequency quadrupole (RFQ) accelerators, power is commonly delivered using waveguide iris or coaxial loop couplers. Iris couplers can handle high RF power but lack tunability, while coaxial loop couplers offer tuning flexibility but are limited in power handling and thermal performance. We propose a new RFQ power coupling concept utilizing a single input coaxial center-fed double-loop antenna built into a vane in an RFQ structure . The design integrates back-to-back loops into the RFQ vanes, fed by a TEM coaxial transmission line with standard 50-Ω characteristic impedance. The configuration can allow straightforward and easy ceramic window replacement without retuning, and coupling strength is adjusted with protruding tuning rods. Numerical simulations, performed with both a simplified RFQ model and the Spallation Neutron Source RFQ, demonstrate improved RF performance and reduced dipole mode excitation. The results establish the coaxial double-loop coupler as a practical alternative for high-power RFQ coupling applications.

Lee, Sung-Woo [ORNL] (ORCID:000000030915835X)↗

RESULTS OF ACCELERATED LIFE TESTING OF LCLS-II CAVITY TUNER MOTOR

An Accelerated Life Test (ALT) of the Phytron stepper motor used in the LCLS-II cavity tuner has been conducted at JLab. Since the motor will reside inside the cryomodule, any failure would lead to a very costly and arduous repair. As such, the motor was tested for the equivalent of 30 lifetimes before being approved for use in the production cryomodules. The 9-cell LCLS-II cavity is simulated by disc springs with an equivalent spring constant. Plots of the motor position vs. tuner position ' measured via an installed linear variable differential transformer (LVDT) ' are used to measure motor motion. The titanium spindle was inspected for loss of lubrication. The motor passed the ALT, and is set to be installed in the LCLS-II cryomodules.

Huque, Naeem↗

Analysis of RF losses and material characterization of samples removed from a Nb 3 Sn-coated superconducting RF cavity

Nb 3 Sn (T c ≈18 K and H sh ≈400 mT) is a prospective material to replace Nb (T c ≈9 K and H sh ≈200 mT) in SRF accelerator cavities for significant cost reduction and performance enhancement. Because of its material properties, Nb3Sn is best employed as a thin film (coating) inside an already built RF cavity structure. A particular test cavity noted as C3C4 was a 1.5 GHz single-cell Nb cavity, coated with Nb3Sn using Sn vapor diffusion process at Jefferson Lab. Cold measurements of the coated cavity indicated the superconducting transition temperature of about 18 K. Subsequent RF measurements indicated field-dependent surface resistance both at 4.3 K and 2.0 K. After initial cold measurements, the cavity RF loss distribution was studied with a thermometry mapping system. Loss regions were identified with thermometry and were cut out for material analysis. The presence of significantly thin patchy regions and other carbon-rich defects is associated with strong local field-dependent surface resistance. This paper summarizes RF and thermometry results correlated with material science findings.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The 300 mA SRF ERL

Energy Recovery Linacs (ERL) are important for a variety of applications, from high-power Free-Electron Lasers (FEL) to polarized-electron polarized-proton colliders. The ERL current is arguably the most important characteristic of ERLs for such applications. With that in mind, the Collider-Accelerator Department at Brookhaven National Laboratory embarked on the development of a 300 mA ERL to serve as an R and D test-bed for high-current ERL technologies. These include high-current, extremely well damped superconducting accelerating cavities, high-current superconducting laser-photocathode electron guns and high quantum-efficiency photocathodes. In this presentation I will cover these ERL related developments.

43 PARTICLE ACCELERATORS↗