Search NASA⌕ Search

SEARCH · Search NASA

Results for “Active cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Natural and anthropogenic contributions to the hurricane drought of the 1970s–1980s

Atlantic hurricane activity experienced a pronounced lull during the 1970s and 1980s. The current explanation that anthropogenic aerosol radiative forcing cooled the sea surface locally fails to capture the magnitude of this large decrease in activity. To explain this hurricane drought, we propose that the radiative effects of sulfate aerosols from Europe and North-America decreased precipitation in the Sahara-Sahel region, leading to an enhancement of dust regional emissions and transport over the Atlantic. This dust in turn enhanced the local decrease of sea-surface temperature and of hurricane activity. Here, we show that dust emissions from the Sahara peaked in phase with regional sulfate aerosol optical thickness and Sahel drought conditions, and that dust optical depth variations alone can explain nearly half of the sea-surface temperature depression in the 1970s and 1980s.

54 ENVIRONMENTAL SCIENCES↗

A CONDUCTION-BASED HEAT PIPE MODEL FOR ANALYZING THE ENTIRE PROCESS OF LIQUID-METAL HEAT PIPE STARTUP

The Heat Pipe-cooled Microreactor (HPM) is one of the micro nuclear reactor designs under active study at the U.S. Idaho National Laboratory. Among the major concerns of HPM research is to understand the startup behavior of the heat pipe-cooled system associated with the startup of the liquid-metal heat pipes initialing from frozen state. The startup of liquid-metal heat pipes typically involves a number of nonlinear mass and heat transport processes including the phase change from solid to liquid and vapor. Hence, it is still a huge challenge to simulate the liquid-metal heat pipe startup using conventional CFD methods and software. The major difficulties of numerical CFD modeling come from the phase-change process, multiphase interaction, microporous wick flow, and compressible gas dynamics that occur during startup of the liquid-metal heat pipes. This paper proposes a simplified conduction-based method to provide practical insights into the entire startup process of the liquid-metal heat pipes while mitigating the challenges of addressing all the complex physics. We discuss the theoretical basis and modeling assumptions to analyze the liquid-metal heat pipe startup from frozen state based solely on heat-conduction equations. Then, the proposed model is implemented into the commercial CFD software to verify the model performance. The model prediction results are discussed via the comparison with the experimental data obtained from sodium heat-pipe startup experiments.

42 ENGINEERING↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗

Feasibility of lead-bismuth-cooled fast reactor with fuel shuffling strategy

This paper investigates the feasibility of fuel shuffling of the Advanced Nitride-fueled Simplified 100 MWe (ANTS-100e) Lead-bismuth-cooled Fast Reactor (LFR). The preliminary design has the active core of 235 cm in diameter and 100 cm high. The core is composed of 138 hexagonal fuel assemblies enclosed with a 15-15Ti steel duct. The core adopts the onion zoning with the two zones of low-enriched uranium for a better breeding capability to maximize the first cycle length to 10 effective full-power years (EFPYs). The fuel shuffling study is performed by using the UNIST in-house Monte Carlo code MCS. The neutronic parameters such as the multiplication factor and burnup are being investigated. The fuel shuffling strategy is evaluated through several loading patterns for flattening radial power distribution. It is also found that the core with fuel shuffling could lengthen the core lifetime by more than 5 EFPYs without introducing fresh fuel. Thus, it appears that the ANTS-100e can be principally designed to have the second cycle with another 10 EFPYs if introducing fresh fuel into the core. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Production efficiencies of sound waves in the intracluster medium driven by AGN jets

Feedback from active galactic nuclei (AGNs) is believed to be the most promising solution to the cooling flow problem in cool-core clusters. Dissipation of sound waves is considered as one of the possible heating mechanisms; however, its relative contribution to heating remains unclear. To estimate the energy budget for heating, we perform 3D hydrodynamic simulations of AGN jet injections in a Perseus-like cluster and quantify the amount of energy stored in the forms of weak shocks and waves. For this work, e find that, for a single jet injection with typical parameters in cool-core clusters, ${\sim}9{{\ \rm per\ cent}}$ of the total jet energy is stored in compressional waves (including both shocks and waves). However, due to the destructive effects among randomly phased waves as well as the dissipation of shock energies, in our simulations including self-regulated AGN feedback, no more than $3{{\ \rm per\ cent}}$ of the total injected energy goes into compressional waves. We further separate the energy contribution from shocks and waves and find that, for a single outburst, the shocks can only contribute to ${\sim}20{-}30{{\ \rm per\ cent}}$ of the total compressional energy in the inner radii and quickly dissipate away. In the self-regulated case where shocks are repeatedly generated, shocks completely dominate over sound waves in the inner region and can still provide ${\sim}40{-}50{{\ \rm per\ cent}}$ of the total compressional energy at outer radii. Our results suggest that the production of sound waves is not as efficient as what was previously found, and thus sound wave dissipation may be a subdominant source of heating in cool-core clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Cold Gas and Star Formation in the Phoenix Cluster with JWST

We present integral field unit observations of the Phoenix Cluster with the JWST Mid-infrared Instrument’s Medium Resolution Spectrometer. We focus this study on the molecular gas, dust, and star formation in the brightest cluster galaxy (BCG). We use precise spectral modeling to produce maps of the silicate dust, molecular gas, and polycyclic aromatic hydrocarbons (PAHs) in the inner ∼50 kpc of the cluster. We measure the optical depth from silicates by comparing the observed H 2 line ratios to those predicted by excitation models. We provide updated measurements of the total molecular gas mass of $1.9^{+0.5}_{-0.04}$ x 10 10 M ⊙ , which agrees with CO-based estimates, providing an estimate of the CO-to-H 2 conversion factor of α CO = 0.8 ± 0.2 M ⊙ pc -2 (K km s -1 ) -1 ; an updated stellar mass of M * = 2.6 ± 0.5 × 10 10 M ⊙ ; and star formation rates (SFRs) averaged over 10 and 100 Myr of $\langle$SFR$\rangle$ 10 = 1340 ± 100 M ⊙ yr −1 and $\langle$SFR$\rangle$ 100 = 740 ± 80 M ⊙ yr −1 , respectively. The H 2 emission seems to be powered predominantly by shocks and star formation within the central ∼20 kpc, induced by stellar feedback and radio jets from the active galactic nucleus. Additionally, we find nearly an order-of-magnitude drop in the SFRs estimated by PAH fluxes in cool core BCGs compared to field galaxies, suggesting that hot particles from the intracluster medium are destroying PAH grains even in the central-most tens of kiloparsecs.

Active galaxies↗

Flow Assisted Evaporative Cooling for Electric Motor

This paper examines a novel concept of flow assisted latent heat driven two-phase evaporative cooling (EC) confined in-between slot liner and active-winding of electric motor. Wicking micro-structure enhanced PDMS liner axially sucks coolant in the form of thin film between the PDMS liner and active-winding and eventually enables thin film evaporation on the outer surface of the active-winding. Therefore, EC based thermal management eliminates contact resistance between the winding and slot-liner and, enhances the heat extraction from the winding without compromising the electro-magnetic performance. Two-way coupled electro-magnetic (EM) – computational fluid dynamics/heat transfer (CFD/HT) and EM - lumped parameter thermal network (LPTN) models have been developed to assess the electro-thermal performance of the EC under steady and transient conditions. Taking a case study of a 125 kW jacket cooled BMW i3 motor and dielectric coolant FC-84, EC is shown to be capable of handling a maximum steady state rms current density of 26 A/mm2 at a evaporative heat transfer coefficient of 5,000 W/m2.K, which is about 78.7% higher compared to the traditional jacket cooling (JC). In case of EC, a maximum steady state and transient rms current density of 30 A/mm2 (106.2% higher compared to the JC), and 40.8 A/mm2 have been realized by using high thermal conductivity epoxy (1.9 W/m.K) impregnation material. Thermal performance of the EC is also assessed and compared with JC over a dynamic drive cycle. Lastly, a motorette testing has been performed to demonstrate the applicability of the proposed EC method and to validate the developed modeling framework.

42 ENGINEERING↗

Methane liquefaction with an active magnetic regenerative refrigerator

This manuscript reports liquefaction of methane using an active magnetic regenerative refrigerator (AMRR). The AMRR used to cool from 285 K to 135 K has two identical regenerators fabricated with adjacent layers of four ferromagnetic refrigerants, each with sequentially lower Curie temperatures and lesser masses from hot to cold temperatures. The dual multilayer regenerators were assembled in opposition with a single cold region between them. For this set of experiments equal mass of helium gas was pumped through all layers of the regenerators during the two flow steps of the four-step AMR cycle. After successfully reaching 135 K, a compact condensing coil-fin tube heat exchanger (HEX) with a small storage vessel was mounted in the cold region of the dual regenerator assembly to be cooled during the hot-to-cold helium flow from alternatively demagnetized regenerators. The cold HEX was used to cool and liquefy a process stream of methane gas supplied at 295 K and different pressures in different runs. Further, by measuring time to liquefy a known volume of methane at three different pressures, cooling powers of the AMRR as a function of temperature were determined. The resultant data were compared to those predicted by the AMRR performance model. Conclusions from these experiments and suggestions for future work are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Anomalous lattice expansion of bcc Ta in helium-loaded diamond anvil cells

Anomalous lattice expansion of bcc Ta is observed in helium-loaded diamond anvil cell (DAC) experiments near 6 GPa and above 400 K, while co-loaded W, Mo, and Au exhibit normal thermal expansion. The Ta volume expansion increases with temperature, reaching ~14% near 650 K before plateauing, and is largely retained after recovery to ambient conditions. Time-resolved measurements at 500 K reveal progressive expansion over several hours, consistent with gradual, thermally activated He incorporation. The largely retained expansion during subsequent cooling and holding at 400 K indicates that the incorporated He is predominantly kinetically trapped. The data reveal two distinct regimes: below ~550 K, modest and spatially uniform expansion consistent with interstitial He trapping at isolated, randomly distributed vacancies; above ~550 K, He-vacancy cluster growth producing dramatically larger expansion, peak broadening, and a core–shell microstructure revealed by micron-resolution X-ray diffraction mapping. These results demonstrate that He is not always a passive pressure medium in DAC experiments and reveal a previously unrecognized regime of He-mediated lattice modification in Ta, complementing conventional ion-implantation studies relevant to nuclear and fusion structural materials.

Diamond anvil cell↗

Global Trends of ASME "N-Stamp" Certifications for Nuclear Component Vendors

Historically, nuclear component manufacturing vendors, from small businesses through large conglomerates, have felt compelled to obtain an American Society for Mechanical Engineers (ASME) Nuclear Certification, known colloquially as an "N-stamp", to assure supply chain quality standards that will be acceptable to regulators and safety concerns. Since the N-stamp quality standard is a U.S.-origin code, combined with the apparent decline in the U.S. nuclear industry alongside the growth of the Asian nuclear industry, there is the question of whether the rest of the world, including new entrants to the nuclear industry, also regard N-stamp as a needed certification. This study addresses this question through analysis of the entire N-stamp database of holders, and former holders, of N-stamp certificates of all types and for all regions worldwide from 1989-2020 (the dates available in the database). From this 30 years of data, we find that actually U.S.-based vendors still consistently obtain the largest number of N-stamps worldwide over all time periods, but also find that the countries participating in the N-stamp certification process has broadly expanded beyond just North America, Japan, S. Korea and Western Europe (the primary N-stamp recipients before the mid-2000's). We produced global heats maps and bar charts to illustrate our findings, as well as further investigation into why the data shows changes over time and region. We note that nuclear entities involved with Soviet-type reactors do not participate in the N-stamp process, but instead pursue the Russian version PNAE, which is substantially similar to the ASME code. We conclude that at least from the N-stamp database, the United States nuclear component manufacturing industry is alive and well, although there have been some consolidations, and that the ASME N-stamp appears to still be a valued certificate worldwide, including in China which now ranks second only to the United States in obtaining N-stamp certificates in recent years. We further note that the vendors of new reactor types, in particular High Temperature Gas-Cooled Reactors (HTGRs) and Small Modular Reactors (SMRs), are actively engaged with ASME (and other U.S.-based nuclear standards bodies such as the American Nuclear Society and Nuclear Energy Institute) to coordinate updates to the ASME N-Stamp criteria to ensure applicability of the code for these new designs. Implications of these findings include the following: The global use of the U.S.-origin N-stamp certification supports the view that, despite the decline of the U.S. nuclear industry, the United States remains an esteemed global leader in the area of nuclear safety. As the U.S. Government works to revitalize the U.S. nuclear industry, especially in the area of exports, it may be beneficial to leverage the global standing of the N-stamp certification. The findings indicate that the N-stamp database would be a useful tool for the U.S. Government to use to track the growth of the civil nuclear industry in foreign countries, under certain circumstances. The Excel-format N-stamp database produced as part of this study may be a useful tool for this purpose. N-stamp data may be a useful tool for foreign governments to use to identify nuclear manufacturers within their own country, especially to identify "targets" for outreach on nuclear export control compliance. The U.S. Government could carry this message to foreign partners during bilateral engagements or as part of Nuclear Suppliers Group (NSG) discussions on industry outreach.

42 ENGINEERING↗

FY25 Report on Water NSTF Testing: Parametric and Accident Testing with Lower Tank Inlet

The Natural Convection Shutdown Heat Removal Test Facility (NSTF) at Argonne National Laboratory has continued to generate empirical validation data on the performance of water-based reactor cavity cooling system (RCCS) for seven years. This data is actively being used to support the development of passive decay heat removal systems for advanced reactors. Distinguishing this facility are 1) the large, ½ scale of the facility and 2) its governance under an NQA-1 qualified program for producing data of the highest pedigree for advanced reactor designers and regulators. In addition to the experimental activities discussed in this report, a computational modeling program continues to support the experimental program and further accuracy and understanding of the computational models. Together, the experimental and computational work create a mutually beneficial relationship integral to the overall program objective of advancing the understanding of the RCCS technology.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RELAP5-3D Solutions to Exercise 1 of the OECD-NEA HTTF Benchmark

Discussion of RELAP5-3D solutions to Exercise 1 of the OECD-NEA High Temperature Test Facility (HTTF) Benchmark. Results from ongoing benchmark activities supported by the Advanced Reactor Technologies - Gas-Cooled Reactor Program with use of the High Performance Computing Center at Idaho National Laboratory. Also discussion of Ultra Safe Nuclear Corporation and BWXT plans for the decade, and issues of modern thermal hydraulic tools for prismatic HTGR modeling. Open discussion of verification and validation and ART-GCR campaign to spearhead the development of an HTGR thermal hydraulics benchmark based on the HTTF.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

How does humidity data impact land surface modeling of hydrothermal regimes at a permafrost site in Utqia$\mathrm{\dot{g}}$vik, Alaska?

Humidity is a basic and crucial meteorological indicator commonly measured in several forms, including specific humidity, relative humidity, and absolute humidity. These different forms can be inter-derived based on the saturation vapor pressure (SVP). In past decades, dozens of formulae have been developed to calculate the SVP with respect to, and in equilibrium with, liquid water and solid ice surfaces, but many prior studies use a single function for all temperature ranges, without considering the distinction between over the liquid water and ice surfaces. These different approaches can result in humidity estimates that may impact our understanding of surface-subsurface thermal-hydrological dynamics in cold regions. In this study, we compared the relative humidity (RH) downloaded and calculated from four data sources in Alaska based on five commonly used SVP formulas. These RHs, along with other meteorological indicators, were then used to drive physics-rich land surface models at a permafrost-affected site. Here, we found that higher values of RH (up to 40%) were obtained if the SVP was calculated with the over-ice formulation when air temperatures were below freezing, which could lead to a 30% maximum difference in snow depths. The choice of whether to separately calculate the SVP over an ice surface in winter also produced a significant range (up to 0.2 m) in simulated annual maximum thaw depths. The sensitivity of seasonal thaw depth to the formulation of SVP increases with the rainfall rate and the height of above-ground ponded water, while it diminishes with warmer air temperatures. These results show that RH variations based on the calculation of SVP with or without over-ice calculation meaningfully impact physically-based predictions of snow depth, sublimation, soil temperature, and active layer thickness. Under particular conditions, when severe flooding (inundation) and cool air temperatures are present, care should be taken to evaluate how humidity data is estimated for land surface and earth system modeling.

54 ENVIRONMENTAL SCIENCES↗

Wastewater Recycling Using a Hygroscopic Cooling System

This project by the Energy & Environmental Research Center (EERC), Baltimore Aircoil Company (BAC), and Great River Energy (GRE) evaluated the concept of recycling wastewater at a coal-fired power plant using a hygroscopic cooling system, which is an evaporative cooling technology analogous to conventional cooling towers, except that sparingly soluble dissolved solids are precipitated and removed as waste solids instead of purging them with a liquid blowdown stream. This technology can maximize the use of plant makeup water by obtaining useful evaporative cooling from wastewater while minimizing the volume of wastes needing disposal. Experimental activities were conducted in two phases, a laboratory-based evaluation of the properties of wastewater from the host site, GRE’s Coal Creek Station near Underwood, North Dakota, and a field test of a small pilot hygroscopic cooling system at the host site power plant. Findings from the laboratory study informed the design of the pilot system and the system’s field test performance served as the basis for a techno-economic analysis (TEA) of the hygroscopic recycling concept. At the preferred operating conditions identified during the TEA, the wet-bulb approach temperature of the tower was 7.3°C (13°F) and the volume of blowdown produced by the plant was reduced to 5.4% of its incoming volume. Waste solids produced during field testing were classified as nonhazardous waste based on the measured hazardous element content and evaluation of their leaching potential. However, to qualify as a solid for landfill disposal i.e., as determined by the U.S. Environmental Protection Agency’s paint filter test, it appears that a dewatering step beyond hydrocyclone separation is needed. The baseline levelized cost of wastewater disposal (LCWD) for hygroscopic wastewater recycling was estimated to be $\$ $3.69–$\$ $3.72 per m3 of plant blowdown. Capital cost was estimated to contribute over 54% to the LCWD, and parameters that impact capital cost such as the heat exchange coil material of construction and the tower’s wet-bulb approach temperature were identified as having the greatest impact on overall LCWD. A LCWD estimate prepared for the same application but using thermomechanical brine evaporation was almost 40% higher than that calculated for hygroscopic cooling, despite recovering distilled-quality water for reuse, while the LCWD for disposal-only, deep well injection was estimated to be 30% lower compared to hygroscopic wastewater recycling.

01 COAL, LIGNITE, AND PEAT↗

Amorphization and Crystallization of Hexanitroazobenzene (HNAB) Using Conventional DSC and Flash DSC

Abstract The present work presents results from an investigation of the glass transition and crystallization behaviors of HNAB tested over more than five orders of magnitude of cooling rate from 0.005 °C/s to 600 °C/s (0.3 to 36000 °C/min) by a combination of conventional and Flash differential scanning calorimetry (DSC). The work quantifies the influence of the thermal amorphization route on the properties of this high explosive. Cooling rates faster than 100 °C/s (6000 °C/min) result in amorphous HNAB as expected from prior work, but we also find that amorphization of the HNAB occurs at cooling rates slower than 0.008 °C/s (0.5 °C/min). The behavior of the amorphous HNAB made by slow cooling is compared with that of amorphous HNAB made by fast cooling, as well as with that made by solvent casting in terms of glass transition temperature, apparent activation energy of glass transition, and dynamic fragility parameter m . Besides, the non‐isothermal crystallization response as a function of cooling rate is also reported. The thermal stability and decomposition energy of amorphous HNAB are compared with those of the crystalline counterpart, being similar heats of decomposition of 3295 and 3392 J/g, respectively; suggesting that the amorphous HNAB will have similar thermal stability and chemical energy to the crystalline form.

Koh, Yung P.↗

Cool carriers: triplet diffusion dominates upconversion yield

Perovskites have gained popularity both as the active material in photovoltaics and as bulk triplet sensitizers for solid-state triplet–triplet annihilation upconversion (TTA-UC). Prior to widespread implementation into commercial photovoltaics, an in-depth understanding of the environmental influences on device performance is required. To this point, the temperature-dependent structure–function properties of TTA-UC within methylammonium formamidinium lead triiodide (MAFA)/rubrene UC devices are explored. A strong temperature dependence of the underlying UC dynamics is observed, where the maximum UC efficiency is achieved at 170 K, reflecting the competition between triplet diffusion length, diffusion rate, and triplet–triplet encounter events. Furthermore, a combination of spectroscopic and structural methods and theoretical modelling illustrates that despite the significantly increased carrier lifetime of the perovskite at low temperatures, the TTA-UC dynamics are not governed by the underlying sensitizer properties but rather limited by the underlying triplet diffusion.

Sullivan, Colette M.↗

Dependence of thick filament structure in relaxed mammalian skeletal muscle on temperature and interfilament spacing

Contraction of skeletal muscle is regulated by structural changes in both actin-containing thin filaments and myosin-containing thick filaments, but myosin-based regulation is unlikely to be preserved after thick filament isolation, and its structural basis remains poorly characterized. Here, we describe the periodic features of the thick filament structure in situ by high-resolution small-angle x-ray diffraction and interference. We used both relaxed demembranated fibers and resting intact muscle preparations to assess whether thick filament regulation is preserved in demembranated fibers, which have been widely used for previous studies. We show that the thick filaments in both preparations exhibit two closely spaced axial periodicities, 43.1 nm and 45.5 nm, at near-physiological temperature. The shorter periodicity matches that of the myosin helix, and x-ray interference between the two arrays of myosin in the bipolar filament shows that all zones of the filament follow this periodicity. The 45.5-nm repeat has no helical component and originates from myosin layers closer to the filament midpoint associated with the titin super-repeat in that region. Cooling relaxed or resting muscle, which partially mimics the effects of calcium activation on thick filament structure, disrupts the helical order of the myosin motors, and they move out from the filament backbone. Compression of the filament lattice of demembranated fibers by 5% Dextran, which restores interfilament spacing to that in intact muscle, stabilizes the higher-temperature structure. The axial periodicity of the filament backbone increases on cooling, but in lattice-compressed fibers the periodicity of the myosin heads does not follow the extension of the backbone. Thick filament structure in lattice-compressed demembranated fibers at near-physiological temperature is similar to that in intact resting muscle, suggesting that the native structure of the thick filament is largely preserved after demembranation in these conditions, although not in the conditions used for most previous studies with this preparation.

59 BASIC BIOLOGICAL SCIENCES↗