FGFR antagonist induces protective autophagy in FGFR1-amplified breast cancer cell

Breast cancer, representing approximately 30% of all gynecological cancer cases diagnosed yearly, is a leading cause of cancer-related mortality for women. Amplification of FGFR1 is frequently observed in breast cancers and is associated with poor prognosis. Though FGFRs have long been considered as anti-cancer drug targets, and a cluster of FGFR antagonists are currently under clinical trials, the precise cellular responses under the treatment of FGFR antagonists remains unclear. Here, we show that PD166866, an FGFR1-selective inhibitor, inhibits proliferation and triggers anoikis in FGFR1-amplified breast cancer cell lines. Notably, we demonstrate that PD166866 induces autophagy in FGFR1-amplified breast cancer cell lines, while blockage of autophagy by Atg5 knockdown further enhances the anti-proliferative activities of PD166866. Moreover, mechanistic study reveals that PD166866 induces autophagy through repressing Akt/mTOR signaling pathway. Together, the present study provides new insights into the molecular mechanisms underlying the anti-tumor activities of FGFR antagonists, and may further assist the FGFRs-based drug discovery. -- Highlights: •FGFR1 antagonist inhibits cell viability in FGFR1-amplified breast cancer cells. •FGFR1 antagonist induces autophagy in FGFR1-amplified breast cancer cells. •FGFR1 antagonist-induced autophagy is protective. •FGFR1 antagonist induces autophagy by inhibiting Akt/mTOR pathway.

60 APPLIED LIFE SCIENCES↗

An ultra-high gain and efficient amplifier based on Raman amplification in plasma

Raman amplification arising from the excitation of a density echelon in plasma could lead to amplifiers that significantly exceed current power limits of conventional laser media. Here we show that 1–100 J pump pulses can amplify picojoule seed pulses to nearly joule level. The extremely high gain also leads to significant amplification of backscattered radiation from “noise”, arising from stochastic plasma fluctuations that competes with externally injected seed pulses, which are amplified to similar levels at the highest pump energies. The pump energy is scattered into the seed at an oblique angle with 14 J sr -1 , and net gains of more than eight orders of magnitude. The maximum gain coefficient, of 180 cm -1 , exceeds high-power solid-state amplifying media by orders of magnitude. The observation of a minimum of 640 J sr -1 directly backscattered from noise, corresponding to ≈10% of the pump energy in the observation solid angle, implies potential overall efficiencies greater than 10%.

42 ENGINEERING↗

Time-reversal duality of high-efficiency RF power amplifiers

The similarity between RF power amplifiers and rectifiers is discussed. It is shown that the same high-efficiency harmonically-terminated power amplifier can be operated in a dual rectifier mode. Nonlinear simulations with a GaN HEMT transistor model show the time-reversal intrinsic voltage and current waveform relationship between a class-F amplifier and rectifier. Measurements on a class-F-1 amplifier and rectifier at 2.14 GHz demonstrate over 80% efficiency in both cases.

Reveyrand, T↗

Photon acceleration in the amplified plasma density wake of two copropagating laser pulses

Photon acceleration of a laser pulse occurs in a medium with a space and time-varying permittivity. Using Hamiltonian formulation, a theoretical study of the frequency upshift of a probe laser pulse, which is considered as a 'quasiphoton' or 'test particle,' propagating through an amplified plasma density wake of two copropagating laser pulses, is presented. The linear superposition of wakefields studied using an analytical model shows that the presence of a controlling pulse amplifies the wake of a driver pulse. The amplified wake amplitude can be controlled by varying the delay between the two pulses. Two-dimensional particle-in-cell simulations demonstrate wake superposition due to the two copropagating laser pulses. A phase space analysis shows that the probe photon can experience a significant frequency upshift in the amplified density wake. Furthermore, the range of photon frequencies trapped and accelerated is determined by the amplitude of the density wake.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Broadband coplanar-waveguide-based impedance-transformed Josephson parametric amplifier

Quantum-limited Josephson parametric amplifiers play a pivotal role in advancing the field of circuit quantum electrodynamics by enabling the fast and high-fidelity measurement of weak microwave signals. Therefore, it is necessary to develop robust parametric amplifiers with low noise, broad bandwidth, and reduced design complexity for microwave detection. However, current broadband parametric amplifiers either have degraded noise performance or rely on complex designs. Here, we present a device based on the broadband impedance-transformed Josephson parametric amplifier that integrates a hornlike coplanar waveguide transmission line, which significantly decreases the design and fabrication complexity while keeping comparable performance. The device shows an instantaneous bandwidth of 700 (200) MHz for 15 (20) dB gain with an average input saturation power of − 110 dBm and near quantum-limited added noise. The operating frequency can be tuned over 1.4 GHz using an external flux bias. We further demonstrate the negligible backaction from our device on a transmon qubit. The amplification performance and simplicity of our device promise its wide adaptation in quantum metrology, quantum communication, and quantum information processing. Published by the American Physical Society 2024

Qing, Bingcheng (ORCID:0000000345227017)↗

Temporal prepulse contrast degradation in high-intensity CPA lasers from anisotropy of amplifier gain media

Here, we present a study of the temporal pre-pulse contrast degradation of high focused intensity pulses produced in CPA laser systems due to imperfections in amplifier design, alignment of amplifier components, and crystal inhomogeneity. Using an extended cross-polarized imaging technique, we demonstrate the presence of multiple crystal domains inside Ti:sapphire slabs with ≈10 cm diameter. Furthermore, the results of our numerical calculations show that crystalline c-axis orientation inhomogeneity caused by these crystal domains can lead to generation of pre-pulses with relative contrast >10 -10 within several picoseconds before the main pulse. In a multiple-slab amplifier head configuration sometimes used in high repetition rate systems, the misalignment of the amplifier slabs crystalline c-axes with respect to each other can lead to the generation of pre-pulses with relative contrast as high as 10 -6 , depending on the magnitude of misalignment.

47 OTHER INSTRUMENTATION↗

Stacked-mosaic amplifier and diode delivery concept for kJ-class inertial fusion energy laser driver

We report on a laser amplifier architecture designed as a modular element for scaling to multi-megajoule laser facilities intended for inertial fusion energy (IFE) power plants. This kilojoule-class module features a stacked mosaic of gain media integrated with a diode delivery system for efficient optical pumping of the mosaic-structured gain medium, enabling high-repetition-rate operation at high wall plug efficiencies, necessary for an IFE driver. Details of a diode delivery system capable of pumping the mosaic architecture are presented. Comprehensive numerical modeling demonstrates that the stacked-mosaic approach reduces transverse gain by five orders of magnitude compared to a conventional full-aperture Yb:YAG based amplifier, substantially suppressing transverse amplified spontaneous emission (TASE) and enabling enhanced longitudinal energy extraction. Detailed analysis of thermal management and wavefront distortion in a 4 × 4 mosaic array indicates that temperature gradients and thermally induced aberrations are effectively controlled using gas cooling and commercially available phase-plate and deformable mirror technologies. We further discuss the applicability of a stacked-mosaic architecture to direct-drive IFE schemes, where broad spectral bandwidth is critical, and its compatibility with frequency conversion modules for up-conversion to blue wavelengths. Finally, an example point design for a 10 kJ, 10 Hz Yb:YAG module operating at 175 K with wall-plug efficiency exceeding 10 % is presented, underscoring the feasibility of this approach for next-generation high-energy lasers for IFE drivers. The results establish the stacked-mosaic amplifier as a scalable, robust platform not only for IFE but also for a broad range of advanced scientific and industrial laser applications.

Lasers↗

Development and Operation of PIP-II Injector Test, SSR1 Cryomodule, 325 MHz Amplifiers

The PIP-II Injector Test (PIP2IT) has successfully accelerated ionized hydrogen up to 17MeV through a superconducting, single spoke resonator (SSR1) cryomodule at Fermi National Accelerator Laboratory (FNAL). Each of the SSR1 cavities is tuned to 325MHz and requires up to 6 kW of RF power to accelerate 2mA of ionized hydrogen at the design gradients. RF power amplifiers, specialized for SRF cavity beam operations, were designed by Bhabha Atomic Research Center (BARC) and constructed in a collaboration between the BARC in Mumbai, India and the Electronics Corporation of India Limited (ECIL) in Hyderabad, India. The RF amplifiers meet the specifications and requirements mutually approved between BARC and FNAL. They operate at 325 MHz with a linear power output of 7 kW in both CW and pulse mode. The amplifiers are compatible with the FNAL accelerator personnel safety system and the cavity protection interlocks. Access to controls and internal diagnostic instrumentation are compatible with EPICS control standards. This paper gives details about RF power amplifier development within the Department of Atomic Energy (DAE), India and the operational details with PIP2IT at FNAL.

43 PARTICLE ACCELERATORS↗

MilliKelvin HEMT Amplifiers for Low Noise High Bandwidth Measurement of Quantum Devices

We demonstrate ultra-low power cryogenic high electron mobility transistor (HEMT) amplifiers for measurement of quantum devices. The low power consumption (few uWs) allows the amplifier to be located near the device, at the coldest cryostat stage (typically less than 100 mK). Such placement minimizes parasitic capacitance and reduces the impact of environmental noise (e.g. triboelectric noise in cabling), allowing for improvements in measurement gain, bandwidth and noise. We use custom high electron mobility transistors (HEMTs) in GaAs/A1GaAs heterostructures. These HEMTs are known to have excellent performance specifically at mK temperatures, with electron mobilities that can exceed 10 6 cm 2 /Vs, allowing for large gain with low power consumption. Low temperature measurements of custom HEMT amplifiers at T = 4 K show a current sensitivity of 50 pA at 1 MHz bandwidth for 5 mW power dissipation, which is an improvement upon performance of amplifiers using off-the-shelf HEMTs.

47 OTHER INSTRUMENTATION↗

Baseline Response of Silicon Strip Detectors and Comparison of Cost-Effective Amplifiers

Silicon strip detectors are a proven and more affordable technology. However, they are susceptible to high radiation damage. As part of the characterization of the effects of high radiation on silicon detectors, a baseline performance of these detectors under normal, low radiation conditions needs to be established. We did this by using an optimized setup and an infrared laser to simulate particle incidents. The detectors responded to applied bias voltage as expected. We then compared the performance of both economy amplifiers and an expensive amplifier as part of the optimized setup. For all intents and purposes, the economy amplifier worked just as well as the expensive amplifier.

43 PARTICLE ACCELERATORS↗

Noise Erasure in Quantum-Limited Current Amplifiers

Superconducting quantum interference devices (SQUIDs) are extraordinarily sensitive to magnetic flux and thus make excellent current amplifiers for cryogenic applications. One such application of high interest to Sandia is the set-up and state read-out of quantum dot based qubits, where a qubit state is read out from a short current pulse (microseconds to milliseconds long) of approximately 100 pA, a signal that is easily corrupted by noise in the environment. A Parametric SQUID Amplifier can be high bandwidth (in the GHz range), low power dissipation (less than 1pW), and can be easily incorporated into multi-qubit systems. In this SAIL LDRD, we will characterize the noise performance of the parametric amplifier front end -- the SQUID -- in an architecture specific to current readout for spin qubits. Noise is a key metric in amplification, and identifying noise sources will allow us to optimize the system to reduce its effects, resulting in higher fidelity readout. This effort represents a critical step in creating the building blocks of a high speed, low power, parametric SQUID current amplifier that will be needed in the near term as quantum systems with many qubits begin to come on line in the next few years.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiple-amplifier sensing charged-coupled device: model and improvement of the node removal efficiency

The multiple-amplifier sensing charge-coupled device (MAS-CCD) has emerged as a promising technology for astronomical observation, quantum imaging, and low-energy particle detection due to its ability to reduce the readout time for the same readout noise level compared with its predecessor, the skipper-CCD, by reading out the same charge packet through multiple inline amplifiers. Previous works identified a new parameter in this sensor, called node removal inefficiency (NRI), related to inefficiencies in charge transfer and residual charge removal from the sense node of each amplifier after readout. These inefficiencies can lead to distortions in the measured signals similar to those produced by the charge transfer inefficiencies in standard CCDs. We introduce more details in the mathematical model of the NRI mechanism and provide techniques to quantify its magnitude from the measured data. It also proposes a new operation strategy that significantly reduces its effect with minimal alterations of the timing sequences or voltage settings for the other signals of the sensor. The proposed technique is demonstrated experimentally on a 16-amplifier MAS-CCD. At the same time, the experimental data demonstrate that this approach minimizes the NRI effect to levels comparable with other sources of distortion such as the charge transfer inefficiency in scientific devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Limit circuit prevents overdriving of operational amplifier

Cutoff-type high gain amplifier coupled by a diode prevents overdriving of operational amplifier. An amplified feedback signal offsets the excess input signal that tends to cause the amplifier to exceed its preset limit. The output is, therfore, held to the set clamp level.

Openshaw, F. L.↗

Development of a 20-W solid-state S-band power amplifier

As an alternative to the use of traveling wave tube amplifiers in spacecraft with long life mission requirements, a solid state S band amplifier was developed. A solid state amplifier with an output of 20 W at 2295 MHz, a dc/RF efficiency of 38%, and a gain of 27 dB was developed. The physical and electrical performance of the solid state amplifier are described.

Vandercapellen, A. G.↗

Low noise parametric amplifiers for radio astronomy observations at 18-21 cm wavelength

The principle characteristics and use of SHF parametric amplifiers for radiometer input devices are explored. Balanced parametric amplifiers (BPA) are considered as the SHF signal amplifiers allowing production of the amplifier circuit without a special filter to achieve decoupling. Formulas to calculate the basic parameters of a BPA are given. A modulator based on coaxial lines is discussed as the input element of the SHF. Results of laboratory tests of the receiver section and long-term stability studies of the SHF sector are presented.

Kanevskiy, B. Z.↗

Development and fabrication of S-band chip varactor parametric amplifier

A noncryogenic, S-band parametric amplifier operating in the 2.2 to 2.3 GHz band and having an average input noise temperature of less than 30 K was built and tested. The parametric amplifier module occupies a volume of less than 1-1/4 cubic feet and weighs less than 60 pounds. The module is designed for use in various NASA ground stations to replace larger, more complex cryogenic units which require considerably more maintenance because of the cryogenic refrigeration system employed. The amplifier can be located up to 15 feet from the power supply unit. Optimum performance was achieved through the use of high-quality unpackaged (chip) varactors in the amplifier design.

Kramer, E.↗

The solid-state Ku-band power amplifier

A survey of IMPATT diodes and negative resistance amplifiers is presented. The first phase of the amplifier effort is discussed in which a single diode reflection amplifier delivering 0.5 watt at 15 GHz with 10-dB gain over a 1-GHz band was developed. The design of a dominant mode resonant combiner is described along with the characterization of the IMPATT diodes. Results are given on the complete amplifier and on the thermal and graceful failure characteristics of the unit.

Geller, B. D.↗

Ku band low noise parametric amplifier

A low noise, K sub u-band, parametric amplifier (paramp) was developed. The unit is a spacecraft-qualifiable, prototype, parametric amplifier for eventual application in the shuttle orbiter. The amplifier was required to have a noise temperature of less than 150 K. A noise temperature of less than 120 K at a gain level of 17 db was achieved. A 3-db bandwidth in excess of 350 MHz was attained, while deviation from phase linearity of about + or - 1 degree over 50 MHz was achieved. The paramp operates within specification over an ambient temperature range of -5 C to +50 C. The performance requirements and the operation of the K sub u-band parametric amplifier system are described. The final test results are also given.