Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

International Space Station Major Constituent Analyzer On-Orbit Performance

The Major Constituent Analyzer is a mass spectrometer based system that measures the major atmospheric constituents on the International Space Station. A number of limited-life components require periodic changeout, including the analyzer (ORU 02) and the verification gas assembly (ORU 08). The longest lasting ORU 02 was recently replaced after a record service length of 1033 days. The comparatively high performance duration may be attributable to a reduced inlet flow rate into the analyzer, resulting in increased ion pump lifetime; however, there may be other factors as well. A recent schedule slip for delivery of replacement verification gas led to a demonstration that the calibration interval could be extended on a short-term basis. An analysis of ORU 08 performance characteristics indicates that it is possible to temporarily extend the calibration interval from 6 weeks to 12 weeks if necessary.

Gardner, Ben D.↗

Analyzing Distributed Functions in an Integrated Hazard Analysis

Large scale integration of today's aerospace systems is achievable through the use of distributed systems. Validating the safety of distributed systems is significantly more difficult as compared to centralized systems because of the complexity of the interactions between simultaneously active components. Integrated hazard analysis (IHA), a process used to identify unacceptable risks and to provide a means of controlling them, can be applied to either centralized or distributed systems. IHA, though, must be tailored to fit the particular system being analyzed. Distributed systems, for instance, must be analyzed for hazards in terms of the functions that rely on them. This paper will describe systems-oriented IHA techniques (as opposed to traditional failure-event or reliability techniques) that should be employed for distributed systems in aerospace environments. Special considerations will be addressed when dealing with specific distributed systems such as active thermal control, electrical power, command and data handling, and software systems (including the interaction with fault management systems). Because of the significance of second-order effects in large scale distributed systems, the paper will also describe how to analyze secondary functions to secondary functions through the use of channelization.

Morris, A. Terry↗

Systems Analyze Water Quality in Real Time

A water analyzer developed under Small Business Innovation Research (SBIR) contracts with Kennedy Space Center now monitors treatment processes at water and wastewater facilities around the world. Originally designed to provide real-time detection of nutrient levels in hydroponic solutions for growing plants in space, the ChemScan analyzer, produced by ASA Analytics Inc., of Waukesha, Wisconsin, utilizes spectrometry and chemometric algorithms to automatically analyze multiple parameters in the water treatment process with little need for maintenance, calibration, or operator intervention. The company has experienced a compound annual growth rate of 40 percent over its 15-year history as a direct result of the technology's success.

Source record↗

Volatile Analyzer for Lunar Polar Missions

One of the major questions remaining for the future exploration of the Moon by humans concerns the presence of volatiles on our nearest neighbor in space. Observational studies, and investigations involving returned lunar samples and using robotic spacecraft infer the existence of volatile compounds particularly water [1]. It seems very likely that a volatile component will be concentrated at the poles in circumstances where low-temperatures exist to provide cryogenic traps. However, the full inventory of species, their concentration and their origin and sources are unknown. Of particular importance is whether abundances are sufficient to act as a resource of consumables for future lunar expeditions especially if a long-term base involving humans is to be established. To address some of these issues requires a lander designed specifically for operation at a high-lunar latitude. A vital part of the payload needs to be a volatile analyzer such as the Gas Analysis Package specifically designed for identification quantification of volatile substances and collecting information which will allow the origin of these volatiles to be identified [1]. The equipment included, particularly the gas analyzer, must be capable of operation in the extreme environmental conditions to be encountered. No accurate information yet exists regarding volatile concentration even for sites closer to the lunar equator (because of contamination). In this respect it will be important to understand (and thus limit) contamination of the lunar surface by extraneous material contributed from a variety of sources. The only data for the concentrations of volatiles at the poles comes from orbiting spacecraft and whilst the levels at high latitudes may be greater than at the equator, the volatile analyzer package under consideration will be designed to operate at the highest specifications possible and in a way that does not compromise the data.

Gibons, Everett K.↗

International Space Station Major Constituent Analyzer On-Orbit Performance

The Major Constituent Analyzer is a mass spectrometer based system that measures the major atmospheric constituents on the International Space Station. A number of limited-life components require periodic changeout, including the ORU 02 analyzer and the ORU 08 Verification Gas Assembly. Over the past two years, two ORU 02 analyzer assemblies have operated nominally while two others have experienced premature on-orbit failures. These failures as well as nominal performances demonstrate that ORU 02 performance remains a key determinant of MCA performance and logistical support. It can be shown that monitoring several key parameters can maximize the capacity to monitor ORU health and properly anticipate end of life. Improvements to ion pump operation and ion source tuning are expected to improve lifetime performance of the current ORU 02 design.

Gardner, Ben D.↗

OASIS: Organics Analyzer for Sampling Icy Surfaces

Liquid chromatography mass spectrometry (LC-MS) is a well established laboratory technique for detecting and analyzing organic molecules. This approach has been especially fruitful in the analysis of nucleobases, amino acids, and establishing chirol ratios [1 -3]. We are developing OASIS, Organics Analyzer for Sampling Icy Surfaces, for future in situ landed missions to astrochemically important icy bodies, such as asteroids, comets, and icy moons. The OASIS design employs a microfabricated, on-chip analytical column to chromatographically separate liquid ana1ytes using known LC stationary phase chemistries. The elution products are then interfaced through electrospray ionization (ESI) and analyzed by a time-of-flight mass spectrometer (TOF-MS). A particular advantage of this design is its suitability for microgravity environments, such as for a primitive small body.

Getty, S. A.↗

Laser Ablation Mass Spectrometer (LAMS) as a Standoff Analyzer in Space Missions for Airless Bodies

A laser ablation mass spectrometer (LAMS) based on a time-of-flight (TOF) analyzer with adjustable drift length is proposed as a standoff elemental composition sensor for space missions to airless bodies. It is found that the use of a retarding potential analyzer in combination with a two-stage reflectron enables LAMS to be operated at variable drift length. For field-free drift lengths between 33 cm to 100 cm, at least unit mass resolution can be maintained solely by adjustment of internal voltages, and without resorting to drastic reductions in sensitivity. Therefore, LAMS should be able to be mounted on a robotic arm and analyze samples at standoff distances of up to several tens of cm, permitting high operational flexibility and wide area coverage of heterogeneous regolith on airless bodies.

Li, X.↗

A Next Generation Air Monitor: Combining Orion and ISS Requirements for a Common Major Constituent Analyzer

The Major Constituent Analyzer (MCA) is a mass spectrometer-based instrument designed to provide critical monitoring of six major atmospheric constituents; nitrogen, oxygen, hydrogen, carbon dioxide, methane, and water vapor on-board the International Space Station. The analyzer has been an integral part of the Environmental Control and Life Support System (ECLSS) since the station went on-line. The Orion Air Monitor (OAM) was derived from the MCA and heavily optimized for reduced mass, lower power, faster water vapor response, and maintenance-free operation. The resulting OAM is approximately the size of the analyzer portion of the MCA, orbital-replacement unit 02 (ORU 02), while incorporating the functions of three other modules: Data Processing and Communication (ORU 01), Verification Gas Assembly (ORU 08), and Low Voltage Power Supply (ORU 04). The overlap in MCA and OAM requirements makes it possible to derive a common Air Monitor design that spans both applications while minimally impacting the weight and power limits imposed by the Multipurpose Crew Vehicle (MPCV). Benefits to ISS include the retirement of ORUs 01, 04, and 08, reducing up-mass and eliminating EEE parts obsolescence issues through the extended ISS mission phases. Benefits to MPCV and future deployed habitats under the Constellation program include greater interchangeability across ECLSS subsystems. This paper discusses the results of the requirements development study, where a superset of ISS and Orion air monitoring requirements were distilled; evaluated against increases in OAM functionality, mass, and power; and traded-off where possible using simple operating mode modifications. A system architecture and preliminary design addressing the common requirements will be presented.

Burchfield, David E.↗

International Space Station Major Constituent Analyzer On-Orbit Performance

The Major Constituent Analyzer is a mass spectrometer based system that measures the major atmospheric constituents on the International Space Station. A number of limited-life components require periodic change-out, including the ORU 02 analyzer and the ORU 08 Verification Gas Assembly. Improvements to ion pump operation and ion source tuning have improved lifetime performance of the current ORU 02 design. The most recent ORU 02 analyzer assemblies, as well as ORU 08, have operated nominally. For ORU 02, the ion source filaments and ion pump lifetime continue to be key determinants of MCA performance and logistical support. Monitoring several key parameters provides the capacity to monitor ORU health and properly anticipate end of life.

Gardner, Ben D.↗

International Space Station Major Constituent Analyzer On-orbit Performance

The Major Constituent Analyzer (MCA) is a mass spectrometer based system that measures the major atmospheric constituents on the International Space Station. A number of limited-life components require periodic change-out, including the ORU 02 analyzer and the ORU 08 Verification Gas Assembly. The most recent ORU 02 and ORU 08 assemblies are operating nominally. For ORU 02, the ion source filaments and ion pump lifetime continue to be key determinants of MCA performance. Additionally, testing is underway to evaluate the capacity of the MCA to analyze ammonia. Finally, plans are being made to bring the second MCA on ISS to an operational configuration.

Gardner, Ben D.↗

Educational and Scientific Applications of Climate Model Diagnostic Analyzer

Climate Model Diagnostic Analyzer (CMDA) is a web-based information system designed for the climate modeling and model analysis community to analyze climate data from models and observations. CMDA provides tools to diagnostically analyze climate data for model validation and improvement, and to systematically manage analysis provenance for sharing results with other investigators. CMDA utilizes cloud computing resources, multi-threading computing, machine-learning algorithms, web service technologies, and provenance-supporting technologies to address technical challenges that the Earth science modeling and model analysis community faces in evaluating and diagnosing climate models. As CMDA technology and infrastructure have matured, we have developed the educational and scientific applications of CMDA. Educationally, CMDA supported the summer school of the JPL Center for Climate Sciences in 2014, 2015, and 2016. In the summer school, the students work on group research projects where CMDA provide datasets, analysis tools, and provenance support utility tools. Each student is assigned to a virtual machine with CMDA installed in Amazon Web Services. Scientifically, we have developed several science use cases of CMDA covering various topics, datasets, and analysis types. Each of the science use cases is described in terms of a scientific goal, datasets used, the analysis tools used, scientific results discovered, an analysis result such as output plots and data files, and a link to the corresponding analysis service call with all the input arguments filled.

Bao, Qihao↗

Py MILab: Capturing, Analyzing and Storing Test Data

Integrated Computational Materials Engineering (ICME) has recently received widespread attention due to its promises in reducing dependence on physical testing for engineering design by relying on simulation, reducing both time and cost to market for various applications. ICME however requires validated multiscale material models, which is heavily dependent on available test data with full material and test pedigree, including material processing, test and measurement equipment, raw data collection, and analysis methodology and results. Populating searchable information management systems with such rich data sets is often burdensome for data producers, resulting in a lack of findable data for modelers to validate and verify their models. To overcome these cultural barriers to ICME, NASA has developed of various database-integration toolsets that perform both data management activities within the organization’s best practices with additional functionality that relieves the effort of the data producer and promotes adoption of information management system. One such tool currently under development is Py MILab, an automatic framework for automatic capturing, analysis, maintenance, and storage of material test data. Py MILab uses a modular approach for capturing raw data, analyzing the data, and storing the data in a database, interfaced by neutral file structures, to promote plug-and-play capabilities for various analysis types. TMAnalysis is a Python-based tool that performs automatic data reduction and analysis of uniaxial thermomechanical test data. The TMAnalysis toolset can be implemented within the Analysis module of Py MILab, and thus requires a populated neutral file form the Raw Data Module of Py MILab and outputs a Analysis neutral file compatible with the Database Module of Py MILab. TMAnalysis is able to perform automatic segmentation of multistage tests and perform data analysis and reduction, including determination of point-wise properties in tension, compression, and shear, analysis of stress relaxation tests, creep analysis and zone identification, and combination of these stage types for tests with complex loading histories. The TMAnalysis code is accompanied with a graphical user interface (GUI) that allows users to easily analyze test data in bulk, verify the automatic, consistent analysis performed by the backend code, and edit stage segmentation if necessary before producing the output neutral files, ensuring data is properly analyzed and maintained with full traceability.

Data management↗

VisIt: An End-User Tool for Visualizing and Analyzing Very Large Data

VisIt is a popular open source tool for visualizing and analyzing data. It owes its success to its foci of increasing data understanding, large data support, and providing a robust and usable product, as well as its underlying design that fits today's supercomputing landscape. In this short paper, we describe the VisIt project and its accomplishments. The VisIt project's three focal points - understanding data, large data, and delivering a product - together form a powerful environment for analyzing data from HPC simulations. It is used in varied ways: it enables visualization scientists, computational code developers, and the physicists that run these codes to perform a broad range of data understanding activities, including debugging, making movies, and exploring data. The user interface portion of its design provides a powerful paradigm for analyzing data while the data processing portion of its design is well suited for big data. This in turn has led to many successes: in scaling up to high levels of concurrency and large data sizes, in providing a 'home' for large data algorithms, in understanding how to best use supercomputers, and, most importantly, in helping users understand their data. Further, despite significant upcoming changes in supercomputing architecture, VisIt's future appears bright, as it enjoys vibrant user and developer communities.

99 GENERAL AND MISCELLANEOUS↗

System, apparatus and methods to implement high-speed network analyzers

Systems, apparatus and methods for the implementation of high-speed network analyzers are provided. A set of high-level specifications is used to define the behavior of the network analyzer emitted by a compiler. An optimized inline workflow to process regular expressions is presented without sacrificing the semantic capabilities of the processing engine. An optimized packet dispatcher implements a subset of the functions implemented by the network analyzer, providing a fast and slow path workflow used to accelerate specific processing units. Such dispatcher facility can also be used as a cache of policies, wherein if a policy is found, then packet manipulations associated with the policy can be quickly performed. An optimized method of generating DFA specifications for network signatures is also presented. The method accepts several optimization criteria, such as min-max allocations or optimal allocations based on the probability of occurrence of each signature input bit.

42 ENGINEERING↗

Method and system for formation and withdrawal of a sample from a surface to be analyzed

A method and system for formation and withdrawal of a sample from a surface to be analyzed utilizes a collection instrument having a port through which a liquid solution is conducted onto the surface to be analyzed. The port is positioned adjacent the surface to be analyzed, and the liquid solution is conducted onto the surface through the port so that the liquid solution conducted onto the surface interacts with material comprising the surface. An amount of material is thereafter withdrawn from the surface. Pressure control can be utilized to manipulate the solution balance at the surface to thereby control the withdrawal of the amount of material from the surface. Furthermore, such pressure control can be coordinated with the movement of the surface relative to the port of the collection instrument within the X-Y plane.

36 MATERIALS SCIENCE↗

Preliminary Figures of Merit for Isotope Ratio Measurements: The Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Ionization Source Coupled to an Orbitrap Mass Analyzer

ABSTRACT In order to meet a growing need for fieldable mass spectrometer systems for precise elemental and isotopic analyses, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) has a number of very promising characteristics. One key set of attributes that await validation deals with the performance characteristics relative to isotope ratio precision and accuracy. Due to its availability and prior experience with this research team, the initial evaluation of isotope ratio (IR) performance was performed on a Thermo Scientific Exactive Orbitrap instrument. While the mass accuracy and resolution performance for orbitrap analyzers are very well documented, no detailed evaluations of the IR performance have been published. Efforts described here involve two variables: the inherent IR precision and accuracy delivered by the LSAPGD microplasma and the inherent IR measurement qualities of orbitrap analyzers. Important to the IR performance, the various operating parameters of the orbitrap sampling interface, HCD dissociation stage, and ion injection/data acquisition have been evaluated. The IR performance for a range of other elements, including natural, depleted, and enriched uranium isotopes was determined. In all cases the precision and accuracy are degraded when measuring low abundance (<0.1% isotope fractions). In the best case, IR precision on the order of 0.1 %RSD can be achieved, with values of 1-3 %RSD observed for low-abundance species. The results suggest that the LSAPGD is a very good candidate for field deployable MS analysis and that the high resolving powers of the orbitrap may be complemented with a here-to-fore unknown capacity to deliver high-precision isotope ratios.

Environmental Molecular Sciences Laboratory↗