Search NASA⌕ Search

SEARCH · Search NASA

Results for “Angular dependence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Antibaryon Photoproduction using CLAS at Jefferson Lab

Antibaryon production has been investigated since the advent of nuclear physics, largely motivated by the potential for baryon-antibaryon bound states. Due to the recent availability of high statistics experiments there has been a renewed interest in how antibaryons are created in photoproduction. The g12 (E04-005) experiment conducted at Thomas Jefferson National Accelerator Facility used the CEBAF Large Acceptance Spectrometer to provide the world’s largest dataset for baryon-antibaryon photoproduction on a liquid hydrogen target. The focus of this work is to investigate the photoproduction mechanism of gp --> pp¯p through detailed differential cross section measurements from 3.95 to 5.45 GeV. These first time results as well as the resulting total cross section measurement are reported. In particular the energy dependence (s(Eg)) and the angular dependence (ds/d cos(qCM ¯ p )) have interesting features that have never been seen before. On the other hand, the mass distributions (ds/dM(pp) and ds/dM(p ¯ p) do not show evidence for previously reported narrow resonances. In addition, the first time total cross section mesurement of an antineutron in photoproduction using the reaction gp --> pp ¯np- is reported. The significance and implications of these results will be discussed as well.

Phelps, William↗

Directional dependence of equilibrated TLD-400 chips in multiple radiation fields

Fielding of thermoluminescent dosimeters (TLDs) for measurement of photon radiation dose in experiments is the standard practice for γ-irradiation facilities, pulsed power x-ray facilities, and reactor facilities at Sandia National Laboratories (SNL). Due to the high-dose experimental conditions and the mixed ( 1 n, γ) fields in these facilities, SNL radiation metrologists have historically used CaF 2 :Mn TLDs (also known as TLD-400). Recent inquiries to the radiation metrology staff have raised concerns that the aluminum-equilibrated TLD-400 chips may exhibit a directionally dependent response. The metrologists were asked whether the dose measured by the chip may be impacted by the angle of incidence on the equilibrated TLD. To provide a thorough answer to this query, a set of adjoint Monte Carlo radiation transport calculations was performed for three different equilibrated TLDs as well as bare TLD chips using the Integrated Tiger Series (ITS) code. The key feature of the adjoint calculations performed in this study is that each photon escaping the modeled geometry was tallied into angular bins to provide information on both the energy and angular dependence of the equilibrated chip. After the adjoint Monte Carlo calculations were completed, the resulting energy-dependent response function for each angular bin was convolved with multiple photon energy spectra representing various radiation facilities at SNL. The radiation facilities selected for analysis span a range of photon energies from approximately 1 keV up to approximately 20 MeV. Thus, the presented results are applicable to a wide variety of radiation facilities around the world. Although the bare TLD-400 chip was expected to display the largest variation due to the photon angle of impact on the dosimeter, the dosimeter with the thinnest aluminum equilibrator (SNL thin equilibrated TLD-400) was determined to have the biggest differential between the impact angle with the maximum dose ( D max ) and the impact angle with the minimum dose ( D min ). However, the SNL normal equilibrated TLD-400 chip demonstrated a dramatic reduction in that differential between maximum and minimum dose angles. The reduction in this differential is one of the dominant factors in experimenters’ choice to field these dosimeters at SNL radiation facilities. The results from the PNNL (Hanford) energy-flattening field capsule are consistent with the previous publications. The differential dose responses due to the photon impact angle indicate that experimenters should strive to field their TLD-400 dosimeters in a consistent manner to avoid additional uncertainty in the measurements based on dosimeter orientation.

Adjoint radiation transport↗

A novel method to measure ion density in ICF experiments using x-ray spectroscopy of cylindrical tracers

The indirect drive approach to inertial confinement fusion has undergone important advances in the past few years. Improvements in temperature and density diagnostic methods are leading to more accurate measurements of the plasma conditions inside the Hohlraum and therefore to more efficient experimental designs. The implementation of dot spectroscopy has proven to be a versatile approach to extracting space- and time-dependent electron temperatures. In this method, a microdot of a mid-Z material is placed inside the Hohlraum and its K-shell emission spectrum is used to determine the plasma temperature. However, radiation transport of optically thick lines acting within the cylindrical dot geometry influences the outgoing spectral distribution in a manner that depends on the viewing angle. This angular dependence has recently been studied in the high energy density regime at the OMEGA laser facility, which allowed us to design and benchmark appropriate radiative transfer models that can replicate these geometric effects. By combining these models with the measurements from the dot spectroscopy experiments at the National Ignition Facility, we demonstrate here a novel technique that exploits the transport effects to obtain time-resolved measurements of the ion density of the tracer dots, without the need for additional diagnostics. Furthermore, we find excellent agreement between experiment and simulation, opening the possibility of using these geometric effects as a density diagnostic in future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of gravity opientation on the thermal performance of Stirling-type pulse tube cryocoolers

This paper extends the investigation of angular orientation effects to the refrigeration performance of high frequency (-40 Hz) Stirling-type pulse tube cryocoolers typical of those used in long-life space applications. Strong orientation effects on the performance of such cryocoolers have recently been observed during system-level testing of both linear and U-tube type pulse tubes. To quantify the angular dependency effects, data have been gathered on both U-tube and linear type pulse tubes of two different manufacturers as a function of orientation angle, cold-tip temperature, and compressor stroke.

angular dependency↗

New insights gained on mechanisms of low-energy proton-induced SEUs by minimizing energy straggle

In this study, we present low-energy proton single-event upset (SEU) data on a 65 nm SOI SRAM whose substrate has been completely removed. Since the protons only had to penetrate a very thin buried oxide layer, these measurements were affected by far less energy loss, energy straggle, flux attrition, and angular scattering than previous datasets. The minimization of these common sources of experimental interference allows more direct interpretation of the data and deeper insight into SEU mechanisms. The results show a strong angular dependence, demonstrate that energy straggle, flux attrition, and angular scattering affect the measured SEU cross sections, and prove that proton direct ionization is the dominant mechanism for low-energy proton-induced SEUs in these circuits.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Preliminary Verification of the 2-D Transport Module of Radiation Shielding Code ARES - Paper 33

ARES is a multi-group SN particle transport code system with arbitrary order anisotropic scattering. It is primarily used for the nuclear systems' shielding calculation and analysis in the case of one dimensional, two dimensional and three dimensional systems. ARES2D is the 2-D transport module of ARES code system. It is used to solve the first-order form of the steady-state Boltzmann transport equation in the two dimensional geometry with uniform rectangular mesh. The equation's energy dependence is modeled using multiple energy groups. The angular dependence is modeled using discrete ordinates method. The spatial variable is modeled using finite differencing scheme. The overall solution technique is source iteration with Partial Current Rebalance acceleration of the scattering source. ARES2D is capable of calculating k eigenvalue and fixed source problem with arbitrary order anisotropic scattering in two dimensional geometry. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance of absorptive liners in the presence of spinning modes.

Results of free field measurements of the absorption coefficient of fiberglass, which indicate that the material has a high coefficient over a broad frequency range with little angular dependence. This material is also a very effective duct liner and attenuates spinning modes more rapidly than plane waves. The resonant absorber tested exhibits a strong angular and frequency dependence of the absorption coefficient, is only a moderately effective duct liner for spinning modes, and produces no measurable attenuation for plane waves.

Mcdaniel, O. H.↗

Time-dependent hydrodynamic phenomena in the envelopes of the Be stars

Temporal and angular variations in the motion and distribution of circumstellar material about Be stars are studied by means of a simple hydrodynamical approach. The flow variables are each written as the sum of a known, steady-state axisymmetric term and a smaller component which contains both temporal and angular dependence. Substitution of these dichotomous expressions for the flow variables into Euler's equation and the continuity equation leads to a set of linearized equations for the terms which depend on time and angle. Solutions can be found to a somewhat approximated version of the linearized equations, and these solutions explain the qualitative features of the observed short-time variations.

Morgan, T. H.↗

Self-induced spin-orbit torques in metallic ferromagnets

Herein we present a phenomenological theory of spin-orbit torques in a metallic ferromagnet with spin-relaxing boundaries. The model is rooted in the coupled diffusion of charge and spin in the bulk of the ferromagnet, where we account for the anomalous Hall effects as well as the anisotropic magnetoresistance in the corresponding constitutive relations for both charge and spin sectors. The diffusion equations are supplemented with suitable boundary conditions reflecting the spin-sink capacity of the environment. In inversion-asymmetric heterostructures, the uncompensated spin accumulation exerts a dissipative torque on the order parameter, giving rise to a current-dependent linewidth in the ferromagnetic resonance with a characteristic angular dependence. We compare our model to recent spin-torque ferromagnetic resonance measurements, illustrating how rich self-induced spin-torque phenomenology can arise even in simple magnetic structures.

36 MATERIALS SCIENCE↗

Characterization of the Exradin W1 scintillator for use in radiotherapy

Purpose: To evaluate the main characteristics of the Exradin W1 scintillator as a dosimeter and to estimate measurement uncertainties when used in radiotherapy. Methods: We studied the calibration procedure, energy and modality dependence, short-term repeatability, dose-response linearity, angular dependence, temperature dependence, time to reach thermal equilibrium, dose-rate dependence, water-equivalent depth of the effective measurement point, and long-term stability. An uncertainty budget was derived for relative and absolute dose measurements in photon and electron beams. Results: Exradin W1 showed a temperature dependence of −0.225% °C{sup −1}. The loss of sensitivity with accumulated dose decreased with use. The sensitivity of Exradin W1 was energy independent for high-energy photon and electron beams. All remaining dependencies of Exradin W1 were around or below 0.5%, leading to an uncertainty budget of about 1%. When a dual channel electrometer with automatic trigger was not used, timing effects became significant, increasing uncertainties by one order of magnitude. Conclusions: The Exradin W1 response is energy independent for high energy x-rays and electron beams, and only one calibration coefficient is needed. A temperature correction factor should be applied to keep uncertainties around 2% for absolute dose measurements and around 1% for relative measurements in high-energy photon and electron beams. The Exradin W1 scintillator is an excellent alternative to detectors such as diodes for relative dose measurements.

60 APPLIED LIFE SCIENCES↗

Light scattering by a rough surface of human skin. 1. The luminance factor of reflected light

Based on the analytical solution of Maxwell's equations, we have studied the angular structure of the luminance factor of light reflected by the rough skin surface with large-scale relief elements, illuminated by a directed radiation beam incident at an arbitrary angle inside or outside the medium. The parameters of the surface inhomogeneities are typical of human skin. The calculated angular dependences are interpreted from the point of view of the angular distribution function of micro areas. The results obtained can be used for solving direct and inverse problems in biomedical optics, in particular for determining the depth of light penetration into a biological tissue, for studying the light action spectra on tissue chromophores under the in vivo conditions, for developing diagnostic methods of structural and biophysical parameters of a medium, and for optimising the mechanisms of interaction of light with biological tissues under their noninvasive irradiation through skin. (biomedical optics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-BRE-02: Characterization of a New Commercial Single Crystal Diamond Detector in Photon, Electron and Proton Beams

Purpose: Diamond detectors even with superior characteristics have become obsolete due to poor design, selection of crystal and cost. Recently, microDiamond using synthetic single crystal diamond detector (SCDD) is commercially available which is characterized in various radiation beams in this study. Methods: The characteristics of a commercial SCDD model 60019 (PTW) to a 6- and 15-MV photon beams, 6- and 20-MeV electron beams, and 208 MeV proton beams were investigated and compared to the pre-characterized detectors: TN31010 (0.125 cm{sup 3}) and TN30006 (pinpoint) ionization chambers (PTW), EDGE detector (Sun Nuclear Corp), and SFD Stereotactic Dosimetry Diode Detector (IBA). The depth-dose and profiles data were collected for various field sizes and depths. The dose linearity and dose rate dependency were also evaluated. To evaluate the effects of the preirradiation, the diamond detector which had not been irradiated on the day was set up in the water tank and the response to 100 MU was measured every 20 s. The temperature dependency was tested for the range of 4–60 °C. Angular dependency was evaluated in water phantom by rotating the SCDD. Results: For all radiation types and field sizes, the depth-dose data of the diamond chamber showed identical curve to those of ionization chambers. The profile of the diamond detector was very similar to those of the Edge and SFD detectors, although the 0.125 cm{sup 3} and pinpoint chambers showed averaging effects in the penumbrae region. The temperature dependency was within 0.7% in the range of 4–41°C. A dose of 900 cGy and 1200 cGy were needed to stabilize the chamber to the level within 0.5% and 0.2%, respectively. Conclusion: The type 60019 SCDD detector showed suitable characteristics for depth-dose and profile measurements for wide range of field sizes. However, at least 1000 cGy of pre-irradiation is needed for accurate measurements.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-322: A Comparison of Two Si Detectors for in Vivo Dosimetry

Purpose: To compare two types of semiconductor detectors for in vivo dosimetry by their dependence from various parameters in different conditions. Methods: QED yellow (Sun Nuclear) and EDP (Scanditronix) Si detectors were radiated by a Varian Clinac 2300 ix with 6 and 18 MV energies. 10 cm thickness water equivalent phantom consisted of 30×30 cm{sup 2} squared plates was used for experiments. Dose dependencies for different beam angles (0 – 180°), field size (3–40 cm), dose (50 – 300 MU), and dose rates (50 – 300 MU/min) were obtained and calibrated with Standard Farmer chamber (PTW). Results: Reproducibility, linearity, dose rate, angular dependence, and field size dependence were obtained for QED and EDP. They show no dose-rate dependence in available clinical dose rate range (100–600 MU/min). Both diodes have linear dependence with increasing the dose. Therefore even in case of high radiation therapy (including total body irradiation) it is not necessary to apply an additional correction during in vivo dosimetry. The diodes have different behavior for angular and field size dependencies. QED diode showed that dose value is stable for beam angles from 0 to 60°, for 60–180° correction factor has to be applied for each beam angle during in vivo measurements. For EDP diode dose value is sensitive to beam angle in whole range of angles. Conclusion: The study shows that QED diode is more suitable for in vivo dosimetry due to dose value independence from incident beam angle in the range 0–60°. There is no need in correction factors for increasing of dose and dose rate for both diodes. The next step will be to carry out measurements in non-standard conditions of total body irradiation. After this modeling of these experiments with Monte Carlo simulation for comparison calculated and obtained data is planned.

60 APPLIED LIFE SCIENCES↗

Development and assessment of hierarchical multi-reward reinforcement learning based potential for silicene with state-of-the-art models

We develop a new interatomic force field for Silicene, a 2D material with a buckled hexagonal lattice structure with high polymorphism. We introduce new parameterizations of a Tersoff model using a hierarchical multi-reward reinforcement learning (RL) methodology coupled with a continuous Monte Carlo Tree Search optimization. Our model significantly outperforms existing methods by enhancing the accuracy of predictions for the structural and thermodynamic properties of seven silicene polymorphs-including structure, energy, equation of state, elasticity, and phonon dispersion-when compared to established models. We further make a comprehensive comparison of the various models in predicting the mechanical and thermal properties of silicene. We trace the origin of the improved performance to the description of the angular dependence in the bond-order term, suggesting that modifying the angular terms in short-range models is essential to capture the structural diversity in low dimensional systems.

2D materials↗

Reconstruction of the complex angle-dependent photoionization transition dipole from a laser-dressed streaking experiment

We study the retrieval of the angular dependence of the photoionization transition dipole phase of an attosecond XUV pulse in order to reconstruct the whole photoelectron wave packet after the photoemission process. Using a one-electron model Ar atom, we show that the full electron wave packet can be reconstructed from IR-free photoelectron angular distributions and the streaking electron spectra in an IR-dressed XUV photoionization, with photoelectrons along the common polarization direction of the two pulses. The method relies on the validity of the strong-field approximation so it is valid only for higher energy photoelectrons. Here, we also point out that a single photoionization group time delay is not enough to represent a photoemission process; instead, a complete characterization of the electron wave packet requires the retrieval of the spectral phase over the whole bandwidth of the wave packet.

74 ATOMIC AND MOLECULAR PHYSICS↗

Acceleration and evolution of a hollow electron beam in wakefields driven by a Laguerre-Gaussian laser pulse

We show that a ring-shaped hollow electron beam can be injected and accelerated by using a Laguerre-Gaussian laser pulse and ionization-induced injection in a laser wakefield accelerator. The acceleration and evolution of such a hollow, relativistic electron beam are investigated through three-dimensional particle-in-cell simulations. We find that both the ring size and the beam thickness oscillate during the acceleration. The beam azimuthal shape is angularly dependent and evolves during the acceleration. The beam ellipticity changes resulting from the electron angular momenta obtained from the drive laser pulse and the focusing forces from the wakefield. The dependence of beam ring radius on the laser-plasma parameters (e.g., laser intensity, focal size, and plasma density) is studied. Such a hollow electron beam may have potential applications for accelerating and collimating positively charged particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SCEPTRE 2.2 Angular Quadrature Sets

This document includes details of the angular quadrature sets available in SCEPTRE for performing numerical integrations in the angular phase space. The angular dependence of the boundary and fixed-source terms an d initial angular flux are specified by angular index rather than by direction. It is, therefore, necessary to know the mapping from a specific direction to a direction index. This document includes angular quadrature weights and direction cosines for most of the quadrature sets available in SCEPTRE.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurements of angle-resolved reflectivity of PTFE in liquid xenon with IBEX

Abstract Liquid xenon particle detectors rely on excellent light collection efficiency for their performance. This depends on the high reflectivity of polytetrafluoroethylene (PTFE) at the xenon scintillation wavelength of 178 nm, but the angular dependence of this reflectivity is not well-understood. IBEX is designed to directly measure the angular distribution of xenon scintillation light reflected off PTFE in liquid xenon. These measurements are fully described by a microphysical reflectivity model with few free parameters. Dependence on PTFE type, surface finish, xenon pressure, and wavelength of incident light is explored. Total internal reflection is observed, which results in the dominance of specular over diffuse reflection and a reflectivity near 100% for high angles of incidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗