Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic Frequency Standard”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

183 records · Page 11

Linear operating region in the ozone dial photon counting system

Ozone is a relatively unstable molecule found in Earth's atmosphere. An ozone molecule is made up of three atoms of oxygen. Depending on where ozone resides, it can protect or harm life on Earth. High in the atmosphere, about 15 miles up, ozone acts as a shield to protect Earth's surface from the sun's harmful ultraviolet radiation. Without this shield, we would be more susceptible to skin cancer, cataracts, and impaired immune systems. Closer to Earth, in the air we breathe, ozone is a harmful pollutant that causes damage to lung tissue and plants. Since the early 1980's, airborne lidar systems have been used for making measurements of ozone. The differential absorption lidar (DIAL) technique is used in the remote measurement of O3. This system allows the O3 to be measured as function of the range in the atmosphere. Two frequency-doubled Nd:YAG lasers are used to pump tunable dye lasers. The lasers are operating at 289 nm for the DIAL on-line wavelength of O3, and the other one is operated at 300 nm for the off-line wavelength. The DIAL wavelengths are produced in sequential laser pulses with a time separation of 300 micro s. The backscattered laser energy is collected by telescopes and measured using photon counting systems. The photon counting system measures the light signal by making use of the photon nature of light. The output pulse from the Photo-Multiplier Tube (PE), caused by a photon striking the PMT photo-cathode, is amplified and passed to a pulse height discriminator. The peak value of the pulse is compared to a reference voltage (discrimination level). If the pulse amplitude exceeds the discrimination level, the discriminator generates a standard pulse which is counted by the digital counter. Non-linearity in the system is caused by the overlapping of pulses and the finite response time of the electronics. At low count rates one expects the system to register one event for each output pulse from the PMT corresponding to a photon incident upon the photocathode, however, at higher rates the limitations of the discrimination/counting system will cause the observed count rate to be non-linear with respect to the true count rate. Depending on the pulse height distribution and the discriminator level, the overlapping of pulses (pulse pile-up) can cause count loss or even an additional apparent count gain as the signal levels increase. Characterization of the system, including the pulse height distribution, the signal to noise ratio, and the effect of the discriminator threshold level, is critical in maximizing the linear operating region of the system, thus greatly increasing the useful dynamic range of the system.

Andrawis, Madeleine↗

Low-Pressure, Field-Ionizing Mass Spectrometer

A small mass spectrometer utilizing a miniature field ionization source is now undergoing development. It is designed for use in a variety of applications in which there are requirements for a lightweight, low-power-consumption instrument that can analyze the masses of a wide variety of molecules and ions. The device can operate without need for a high-vacuum, carrier-gas feed radioactive ionizing source, or thermal ionizer. This mass spectrometer can operate either in the natural vacuum of outer space or on Earth at any ambient pressure below 50 torr (below about 6.7 kPa) - a partial vacuum that can easily be reached by use of a small sampling pump. This mass spectrometer also has a large dynamic range - from singly charged small gas ions to deoxyribonucleic acid (DNA) fragments larger than 104 atomic mass units - with sensitivity adequate for detecting some molecules and ions at relative abundances of less than one part per billion. This instrument (see figure) includes a field ionizer integrated with a rotating-field mass spectrometer (RFMS). The field ionizer effects ionization of a type characterized as "soft" in the art because it does not fragment molecules or initiate avalanche arcing. What makes the "soft" ionization mode possible is that the distance between the ionizing electrodes is less than mean free path for ions at the maximum anticipated operating pressure, so that the ionizer always operates on the non-breakdown side of the applicable Paschen curve (a standard plot of breakdown potential on the ordinate and pressure electrode separation on the abscissa). The field ionizer in this instrument is fabricated by micromachining a submicron-thick membrane out of an electrically nonconductive substrate, coating the membrane on both sides to form electrodes, then micromachining small holes through the electrodes and membrane. Because of the submicron electrode separation, even a potential of only 1 V applied between the electrodes gives rise to an electric field with a strength of in excess of a megavolt per meter strong enough to ionize any gas molecules passing through the holes. An accelerator grid and an electrostatic deflector focus the ions from the field ionizer into the rotating-field cell of the RFMS. The potentials applied to the electrodes of the cell to generate the rotating electric field typically range from 1 to 13 V. The ions travel in well-defined helices within this cell, after which they are collected in a Faraday cup. The mass of most of the molecules reaching the Faraday cup decreases with increasing frequency of rotation of the electric field in the cell. Therefore, the frequency of rotation of the electric field is made to vary in order to scan through a desired range of ion masses: For example, lightweight gas molecules are scanned at frequencies in the megahertz range, while DNA and other large organic molecules are scanned at kilohertz frequencies.

Hartley, Frank↗

Constraints on the Nature and Distribution of Iridium Host Phases at the Cretaceous-Tertiary Boundary: Implications for Projectile Identity and dispersal on impact

Among Cretaceous-Tertiary boundary sites worldwide, variations in the concentrations and ratios of elements commonly enriched in meteorites complicate traditional geochemical attempts at impactor identification. Yet they may provide constraints on the physical and chemical processes associated with large-body disruption and dispersal, as well as with diagenesis of projectile components. To this end, we continue our efforts to identify the mineral host-phases of projectile-derived elements, particularly for Ir, and to document their partitioning between crater deposits and ejecta resulting from the Chicxulub basin-forming impact. Building on earlier work, we used INAA to measure Ir concentrations in successively smaller splits of finely powdered impact melt breccia from the Chicxulub Crater in Mexico (sample Y6Nl9-R(b)), and K/T boundary fish clay from Stevns Klint, Denmark (sample FC-1, split from 40 kg of homogenized material intended as an analytical standard). Results for the Chicxulub sample show a heterogeneous Ir distribution and document that at least five discrete Ir-bearing host phases were isolated in subsequent splits, having Ir masses equivalent to pure Ir spheres from about 0.8 to about 3.5 mm in diameter. Three of these are within a sufficiently reduced mass of powder to warrant searching for them using backscattered electron microscopy. In contrast, successively smaller splits of the Stevns Klint fish clay show no statistically significant deviation from the reported value of 32 +/- 2 ng/g Ir, suggesting a uniform Ir host-phase distribution. For the smallest split obtained thus far (100 +/- 40 ng/g Ir), a pure Ir sphere of equivalent Ir mass would be <0.05 min in diameter. (n.b. Although homogenizing and sieving of FC-1 to <75 min obviously obscured variations in stratigraphic distribution, it is unlikely to have affected the size-frequency distribution of Ir host phases.) We previously identified micrometer-scale Ir host phases by electron microscopy in melt-rock samples from two widely separated drill holes at the Chicxulub Basin, including a replicate split of Y6-NI9-R. One is an aggregate of subhedral Ir metal grains enclosed in silicate, in which no other Pt group elements (PGE) were detected. A second particle with twice the mass as the first, concentrated predominantly in a single grain, is associated with minor concentrations of Os, Ru, and Pt, and with adhering particles of corundum and perovskite. A third Ir-rich particle, with a greater apparent Os concentration, was identified before being lost as a result of charging under the electron beam. In addition to demonstrating the preservation of projectile components within the Chicxulub Crater, analogous phase associations in Ca- and Al-rich inclusions (CAI) from C2 and C3 chondrites suggest to us that these melt-rock Ir host phases are relics from a carbonaceous chondrite K/T boundary impactor Although the obviously low Ru/Ir ratios of the Chicxulub Ir host phases are qualitatively consistent with suggested PGE fractionation with distance during condensation in an ejecta cloud, it seems difficult to explain the accumulation of the about 3 x 10(exp 11) Ir atoms required to form a about 10(exp -10) g nugget of pure Ir metal within a jet of vaporized projectile expanding at 1-4 km/s, or to effectively exclude or remove commonly alloyed PGE and siderophile elements by fractionation processes resulting from condensation, oxidation, sulfidization, exsolution, or autometamorphism during cooling of the melt. We do not dismiss the importance of these processes entirely; on the contrary, other geochemical and mineralogical aspects of the melt rocks require them, and condensation from the expanding ejecta cloud appears to best explain the primary Ir host-phase distribution in the fish clay, as well as the high Ir concentrations associated with spinel-bearing spheroids at the K/T boundary in the Pacific Ocean . If the "relict" hypothesis is correct, micronuggets of other PGEs and alloys, not detected by our INAA screening, should also occur in the melt rocks. Possibly, the discrete host phases with lesser Ir masses are such alloys with subordinate Ir, rather than simply smaller, predominantly Ir-bearing particles. A CAI source for the relics would be consistent with either a comet or an asteroid K/T impact at Chicxulub. (Additional information contained in the original.)

Schuraytz, B. C.↗