Search NASA⌕ Search

SEARCH · Search NASA

Results for “BACKGROUND EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Baroreflex buffering and susceptibility to vasoactive drugs

BACKGROUND: The overall effect of vasoactive drugs on blood pressure is determined by a combination of the direct effect on vascular tone and an indirect baroreflex-mediated effect, a baroreflex buffering of blood pressure. Differences in baroreflex function affect the responsiveness to vasoactive medications, particularly baroreflex buffering of blood pressure; however, the magnitude is not known. METHODS AND RESULTS: We characterized baroreflex function and responses to vasoactive drugs in patients with idiopathic orthostatic intolerance, patients with essential hypertension, patients with monogenic hypertension and brachydactyly, patients with multiple system atrophy, and control subjects. We used phenylephrine sensitivity during ganglionic blockade as a measure of baroreflex buffering. Phenylephrine (25 microg) increased systolic blood pressure 6+/-1.6 mm Hg in control subjects, 6+/-1.1 mm Hg in orthostatic intolerance patients, 18+/-3.9 mm Hg in patients with essential hypertension, 31+/-3.4 mm Hg in patients with monogenic hypertension, and 25+/-3.4 mm Hg in patients with multiple system atrophy. Similar differences in sensitivities between groups were observed with nitroprusside. The sensitivity to vasoactive drugs was highly correlated with baroreflex buffering function and to a lesser degree with baroreflex control of heart rate. In control subjects, sensitivities to nitroprusside and phenylephrine infusions were correlated with baroreflex heart rate control and sympathetic nerve traffic. CONCLUSIONS: Our findings are consistent with an important effect of baroreflex blood pressure buffering on the sensitivity to vasoactive drugs. They suggest that even moderate changes in baroreflex function may have a substantial effect on the sensitivity to vasoactive medications.

NASA Discipline Regulatory Physiology↗

Intelligent Automation Approach for Improving Pilot Situational Awareness

Automation in the aviation domain has been increasing for the past two decades. Pilot reaction to automation varies from highly favorable to highly critical depending on both the pilot's background and how effectively the automation is implemented. We describe a user-centered approach for automation that considers the pilot's tasks and his needs related to accomplishing those tasks. Further, we augment rather than replace how the pilot currently fulfills his goals, relying on redundant displays that offer the pilot an opportunity to build trust in the automation. Our prototype system automates the interpretation of hydraulic system faults of the UH-60 helicopter. We describe the problem with the current system and our methodology for resolving it.

Spirkovska, Lilly↗

Simulations of Inducers at Low-flow Off-design Conditions

Background on thermal effects on cavitation and numerical framework. Validation of numerical model for cryogens in CRUNCH CFD(R). Comparison with subscale test data hord (1973). Simulations of liquid hydrogen inducer at various flow coefficients. 120% of design, Design, and 80% of Design flow rate. Detailed comparison of flow profiles. Sensitivity of backflow to turbulent viscosity noted. Conclusion.

Hosangadi, Ashvin↗

A New Unsteady Model for Dense Cloud Cavitation in Cryogenic Fluids

Contents include the following: Background on thermal effects in cavitation. Physical properties of hydrogen. Multi-phase cavitation with thermal effect. Solution procedure. Cavitation model overview. Cavitation source terms. New cavitation model. Source term for bubble growth. One equation les model. Unsteady ogive simulations: liquid nitrogen. Unsteady incompressible flow in a pipe. Time averaged cavity length for NACA15 flowfield.

Hosangadi, Ashvin↗

Ultrasonic Detectors Safely Identify Dangerous, Costly Leaks

In 1990, NASA grounded its space shuttle fleet. The reason: leaks detected in the hydrogen fuel systems of the Space Shuttles Atlantis and Columbia. Unless the sources of the leaks could be identified and fixed, the shuttles would not be safe to fly. To help locate the existing leaks and check for others, Kennedy Space Center engineers used portable ultrasonic detectors to scan the fuel systems. As a gas or liquid escapes from a leak, the resulting turbulence creates ultrasonic noise, explains Gary Mohr, president of Elmsford, New York-based UE Systems Inc., a long-time leader in ultrasonic detector technologies. "In lay terms, the leak is like a dog whistle, and the detector is like the dog ear." Because the ultrasound emissions from a leak are highly localized, they can be used not only to identify the presence of a leak but also to help pinpoint a leak s location. The NASA engineers employed UE s detectors to examine the shuttle fuel tanks and solid rocket boosters, but encountered difficulty with the devices limited range-certain areas of the shuttle proved difficult or unsafe to scan up close. To remedy the problem, the engineers created a long-range attachment for the detectors, similar to "a zoom lens on a camera," Mohr says. "If you are on the ground, and the leak is 50 feet away, the detector would now give you the same impression as if you were only 25 feet away." The enhancement also had the effect of reducing background noise, allowing for a clearer, more precise detection of a leak s location.

Source record↗

Microwave Frequency Polarizers

This article describes the fabrication and analysis of microwave frequency polarizing grids. The grids are designed to measure polarization from the cosmic microwave background. It is effective in the range of 500 to 1500 micron wavelength. It is cryogenic compatible and highly robust to high load impacts. Each grid is fabricated using an array of different assembly processes which vary in the types of tension mechanisms to the shape and size of the grids. We provide a comprehensive study on the analysis of the grids' wire heights, diameters, and spacing.

polarization↗

Temperature Mapping of Air Film-Cooled Thermal Barrier Coated Surfaces Using Cr-Doped GdAlO3 Phosphor Thermography

It has been recently shown that the high luminescence intensity from a Cr-doped GdAlO3 (Cr:GdAlO3) thermographic phosphor enables non-rastered full-field temperature mapping of thermal barrier coating (TBC) surfaces to temperatures above 1000C. In this presentation, temperature mapping by Cr:GdAlO3 based phosphor thermometry of air film-cooled TBC-coated surfaces is demonstrated for both scaled-up cooling hole geometries as well as for actual components in a burner rig test environment. The effects of thermal background radiation and flame chemiluminescence on the measurements are investigated, and advantages of this method over infrared thermography as well as the limitations of this method for studying air film cooling are discussed.

thermographic phoshor↗

Cooling Effectiveness Measurements for Air Film Cooling of Thermal Barrier Coated Surfaces in a Burner Rig Environment Using Phosphor Thermometry

While the effects of thermal barrier coating (TBC) thermal protection and air film cooling effectiveness are usually studied separately, their contributions to combined cooling effectiveness are interdependent and are not simply additive. Therefore, combined cooling effectiveness must be measured to achieve an optimum balance between TBC thermal protection and air film cooling. In this investigation, surface temperature mapping was performed using recently developed Cr-doped GdAlO3 phosphor thermometry. Measurements were performed in the NASA GRC Mach 0.3 burner rig on a TBC-coated plate using a scaled up cooling hole geometry where both the mainstream hot gas temperature and the blowing ratio were varied. Procedures for surface temperature and cooling effectiveness mapping of the air film-cooled TBC-coated surface are described. Applications are also shown for an engine component in both the burner rig test environment as well as an engine afterburner environment. The effects of thermal background radiation and flame chemiluminescence on the measurements are investigated, and advantages of this method over infrared thermography as well as the limitations of this method for studying air film cooling are discussed.

air film cooling↗

The X-ray Integral Field Unit (X-IFU) for Athena

Athena is designed to implement the Hot and Energetic Universe science theme selected by the European Space Agency for the second large mission of its Cosmic Vision program. The Athena science payload consists of a large aperture high angular resolution X-ray optics (2 m2 at 1 keV) and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager. The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), oering 2.5 eV spectral resolution, with approximately 5" pixels, over a field of view of 5' in diameter. In this paper, we present the X-IFU detector and readout electronics principles, some elements of the current design for the focal plane assembly and the cooling chain. We describe the current performance estimates, in terms of spectral resolution, effective area, particle background rejection and count rate capability. Finally, we emphasize on the technology developments necessary to meet the demanding requirements of the X-IFU, both for the sensor, readout electronics and cooling chain.

X-ray↗

The Effects of Uncertainty in Initial CME Input Parameters on Deflection, Rotation, Bz, and Arrival Time Predictions

Understanding the effects of coronal mass ejections (CMEs) requires knowing if and when they will impact and their properties upon impact. Of particular importance is the strength of a CME's southward magnetic field component (Bz ). Kay et al. (2013, https://doi:10.1088/0004-637X/775/1/5, 2015, https://doi:10.1088/948 0004-637X/805/2/168) have shown that the simplified analytic model Forecasting a CME's Altered Trajectory (ForeCAT) can reproduce the deflection and rotation of CMEs. Kay, Gopalswamy, Reinard, and Opher (2017, https://doi.org/10.3847/1538-4357/835/2/117) introduced ForeCAT In situ Data Observer, which uses ForeCAT results to simulate magnetic field profiles. ForeCAT In situ Data Observer reproduces the in situ observations on roughly hourly time scales, suggesting that these models could be extremely useful for predictions of Bz . However, as with all models, both models are sensitive to their input parameters, which may not be precisely known for predictions. We explore this sensitivity using ensembles having small changes in the initial latitude, longitude, and orientation of the erupting CME. We explore the effects of different background magnetic field models and find that the changes in deflection and rotation resulting from the uncertainty in the initial parameters tend to exceed the changes from dierent magnetic backgrounds. The range in the in situ proles tends to scale with the range in the deflection and rotation. We also consider a simple arrival time model using ForeCAT results and nd an average absolute error of only 3 hr. We show that an uncertainty in the CME position of 8.1 ± 6.9 leads to variations of 6 hr in the arrival time. This measure depends strongly on the location of impact within the CME with the arrival time changing less for impacts near the nose.

Kay, Christina D.↗

Performance and Facility Background Pressure Characterization Tests of NASAs 12.5-kW Hall Effect Rocket with Magnetic Shielding Thruster

NASA's Space Technology Mission Directorate (STMD) Solar Electric Propulsion Technology Demonstration Mission (SEP/TDM) project is funding the development of a 12.5-kW Hall thruster system to support future NASA missions. The thruster designated Hall Effect Rocket with Magnetic Shielding (HERMeS) is a 12.5-kW Hall thruster with magnetic shielding incorporating a centrally mounted cathode. HERMeS was designed and modeled by a NASA GRC and JPL team and was fabricated and tested in vacuum facility 5 (VF5) at NASA GRC. Tests at NASA GRC were performed with the Technology Development Unit 1 (TDU1) thruster. TDU1's magnetic shielding topology was confirmed by measurement of anode potential and low electron temperature along the discharge chamber walls. Thermal characterization tests indicated that during full power thruster operation at peak magnetic field strength, the various thruster component temperatures were below prescribed maximum allowable limits. Performance characterization tests demonstrated the thruster's wide throttling range and found that the thruster can achieve a peak thruster efficiency of 63% at 12.5 kW 500 V and can attain a specific impulse of 3,000 s at 12.5 kW and a discharge voltage of 800 V. Facility background pressure variation tests revealed that the performance, operational characteristics, and magnetic shielding effectiveness of the TDU1 design were mostly insensitive to increases in background pressure.

Performance↗

Tropospheric Ozone in the NASA GEOS Model: Effects of Satellite Data Assimilation and Improvements in Background NO x Chemistry

Tropospheric ozone is a major atmospheric oxidant, the primary source of the hydroxyl radical, and a greenhouse gas. In the troposphere, it is produced from the oxidation of carbon monoxide and volatile organic compounds in the presence of nitrogen oxides (NO x =NO+NO 2 ) or has its origins in the stratosphere. The tropospheric ozone burdens in global atmospheric chemistry models disagree by a factor of 1.5, indicating an incomplete understanding of ozone sources and sinks. Here we examine the tropospheric ozone simulation in NASA Global Modeling and Assimilation Office’s (GMAO’s) GEOS model with the GEOS-Chem chemistry mechanism (version 14.2), using observations from satellites, aircraft, ozonesondes, and surface sites. This modeling framework is used to produce GMAO’s GEOS Composition Forecasts (GEOS-CF), and it has been updated extensively with new emission inventories, improved model physics, satellite data assimilation capability, and an up-to-date chemical mechanism that includes tropospheric halogen chemistry and NOx recycling from particulate nitrate. Earlier versions of the model using GEOS-Chem version 12.0 showed an underestimate in tropospheric ozone in the northern hemisphere. We evaluate the ozone simulation in the updated model, focusing on the effects of assimilating satellite NO 2 data from the Ozone Monitoring Instrument (OMI), constraining stratospheric ozone to satellite data, and updates to the NOx chemistry. We will examine changes in the vertical profiles of tropospheric ozone over the US in support of the Tropospheric Emissions: Monitoring of Pollution (TEMPO), and discuss implications for the tropospheric ozone budget.

Viral Shah↗

Design and performance of an actively collimated phoswich system for X-ray astronomy

The design and performance of a phoswich type scintillation detector system having 34 sq cm effective collecting area and a sensitivity of 3 x 10 to the -5th power photons/sq cm/s/keV for balloon-borne cosmic X-ray source observations are discussed. The various shield anticoincidence systems are evaluated for effectiveness in reduction of the system background. The total background of nominally 4 x 10 to the -4th power counts/sq cm/s/keV is analyzed and found to consist of aperture flux, K-escape X-rays from the shielding, leakage, and degradation of gamma-rays through the shielding, and several particle induced effects. The background analysis suggests an ultimate practical upper limit of about 8 x 10 to the -5th power counts/sq cm/s/keV might be attainable beyond which further sensitivity improvements will require increased collecting area or a basically differing design approach.

Matteson, J. L.↗

Effect of display update interval, update type, and background on perception of aircraft separation on a cockpit display on traffic information

The concept of a cockpit display of traffic information (CDTI) includes the integration of air traffic, navigation, and other pertinent information in a single electronic display in the cockpit. Concise display symbology was developed for use in later full-mission simulator evaluations of the CDTI concept. Experimental variables used included the update interval motion of the aircraft, the update type, (that is, whether the two aircraft were updated at the same update interval or not), the background (grid pattern or no background), and encounter type (straight or curved). Only the type of encounter affected performance.

Jago, S.↗

Radio-quiet QSO and the X-ray background

Upper limits on the extragalactic soft X-ray background flux (epsilon of about 0.1-0.3 keV) are used to constrain the contribution of X-ray sources with steep spectra to the X-ray background above 1 keV. The effective spectral index of the extragalactic X-ray background is less than 0.76 over the energy range 0.2 and 3.5 keV. Objects with power-law spectra of energy index 1.4, as recently found for a sample of radio-quiet QSO, cannot contribute more than 13 percent of the 2-10 keV X-ray background.

Fabian, A. C.↗

Acquisition and processing of data for isotope-ratio-monitoring mass spectrometry

Methods are described for continuous monitoring of signals required for precise analyses of 13C, 18O, and 15N in gas streams containing varying quantities of CO2 and N2. The quantitative resolution (i.e. maximum performance in the absence of random errors) of these methods is adequate for determination of isotope ratios with an uncertainty of one part in 10(5); the precision actually obtained is often better than one part in 10(4). This report describes data-processing operations including definition of beginning and ending points of chromatographic peaks and quantitation of background levels, allowance for effects of chromatographic separation of isotopically substituted species, integration of signals related to specific masses, correction for effects of mass discrimination, recognition of drifts in mass spectrometer performance, and calculation of isotopic delta values. Characteristics of a system allowing off-line revision of parameters used in data reduction are described and an algorithm for identification of background levels in complex chromatograms is outlined. Effects of imperfect chromatographic resolution are demonstrated and discussed and an approach to deconvolution of signals from coeluting substances described.

NASA Discipline Exobiology↗