Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM OPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Topological Switching and Orbiting Dynamics of Colloidal Spheres Dressed with Chiral Nematic Solitons

Metastable configurations formed by defects, inclusions, elastic deformations and topological solitons in liquid crystals are a promising choice for building photonic crystals and metamaterials with a potential for new optical applications. Local optical modification of the director or introduction of colloidal inclusions into a moderately chiral nematic liquid crystal confined to a homeotropic cell creates localized multistable chiral solitons. Here we induce solitons that ‘‘dress’’ the dispersed spherical particles treated for tangential degenerate boundary conditions, and perform controlled switching of their state using focused optical beams. Two optically switchable distinct metastable states, toron and hopfion, bound to colloidal spheres into structures with different topological charges are investigated. Their structures are examined using Q-tensor based numerical simulations and compared to the profiles reconstructed from the experiments. A topological explanation of observed multistability is constructed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-T-149: Development of the Monte Carlo Simulation Platform Using Geant4 for Designing Heavy Ion Therapy Beam Nozzle

Purpose: The significant issue of particle therapy such as proton and carbon ion was a accurate dose delivery from beam line to patient. For designing the complex delivery system, Monte Carlo simulation can be used for the simulation of various physical interaction in scatters and filters. In this report, we present the development of Monte Carlo simulation platform to help design the prototype of particle therapy nozzle and performed the Monte Carlo simulation using Geant4. Also we show the prototype design of particle therapy beam nozzle for Korea Heavy Ion Medical Accelerator (KHIMA) project in Korea Institute of Radiological and Medical Science(KIRAMS) at Republic of Korea. Methods: We developed a simulation platform for particle therapy beam nozzle using Geant4. In this platform, the prototype nozzle design of Scanning system for carbon was simply designed. For comparison with theoretic beam optics, the beam profile on lateral distribution at isocenter is compared with Mont Carlo simulation result. From the result of this analysis, we can expected the beam spot property of KHIMA system and implement the spot size optimization for our spot scanning system. Results: For characteristics study of scanning system, various combination of the spot size from accerlator with ridge filter and beam monitor was tested as simple design for KHIMA dose delivery system. Conclusion: In this report, we presented the part of simulation platform and the characteristics study. This study is now on-going in order to develop the simulation platform including the beam nozzle and the dose verification tool with treatment planning system. This will be presented as soon as it is become available.

60 APPLIED LIFE SCIENCES↗

Beam Dynamics Considerations in Electron Ion Colliders

The nuclear physics community is converging on the idea that the next large project after FRIB should be an electron-ion collider. Both Brookhaven National Lab and Thomas Jefferson National Accelerator Facility have developed accelerator designs, both of which need novel solutions to accelerator physics problems. In this talk we discuss some of the problems that must be solved and their solutions. Examples in novel beam optics systems, beam cooling, and beam polarization control will be presented. *Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. The U.S. Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce this manuscript for U.S. Government purposes.

Krafft, Geoffrey↗

Field tests of the optical cross beam system

Recent detailed evaluation of the use of an optical cross-beam system to measure convective wind velocities are reported. Low level measurements, where the optical system is looking at either the earth surface or cloud banks, are demonstrated. Further information on the nature and scale of the light fluctuations is reviewed.

Sandborn, V. A.↗

Compact imaging system using a co-linear, high-intensity LED illumination unit to minimize window reflections for background-oriented schlieren, shadowgraph, photogrammetry and machine vision measurements

One aspect of the present disclosure is an imaging system including an optical sensor defining an optical axis. The system further includes a light source. The system may include an optical beam splitter, and may also include an optional diffusing lens that may be configured to diffuse and/or collimate light from the light source and direct light exiting the diffusing lens to the optical beam splitter. The optical beam splitter is configured to direct light from the light source along the optical axis of the optical sensor.

Bathel, Brett F.↗

Structural design considerations for the beam transmission optical system

The paper describes the JPL study leading to a baseline design of the Beam Transmission Optical System (BTOS), designed for the delivery of laser energy from earth to space targets. The study identified the driving environmental and functional requirements; developed a conceptual design of the BTOS telescope; and performed static, thermal distortion, and model analyses to verify that these requirements are met. The study also identified major areas of concern which should be investigated further.

Macneal, Paul D.↗

True Zero Degree Incident Implants on VIISta3000

The deliberate use of channeling to control depth profiles has come of age in the application to CMOS imaging sensor device manufacturing. In order to enable the true zero implant application on VIISta3000, we have optimized beam incidence angle control, using beam optics models and experimental measurements. The experiment measurement and the beam optics analysis results agree, showing a variation of less than 0.03 deg. (1{sigma}) across the wafer and from wafer to wafer. Achieving this accuracy in a manufacturing environment requires careful calibration and tight control of the collimator magnet and the mechanical scan system. In this paper we discuss the root cause of beam incidence angle variation on VIISta3000 and explain the calibration and optimization used to insure the consistent minimized beam incidence angle. We show experimental data, including ThermaWave and SIMS profiles.

43 PARTICLE ACCELERATORS↗

High Bandwidth Optical Links for Micro-Satellite Support

A method, systems, apparatus and device enable high bandwidth satellite communications. An onboard tracking detector, installed in a low-earth orbit satellite, detects a position of an incoming optical beam received/transmitted from a first ground station of one or more ground stations. Tracker electronics determine orientation information of the incoming optical beam based on the position. Control electronics receive the orientation information from the tracker electronics, and control a waveguide drive electronics. The waveguide drive electronics control a voltage that is provided to an electro-optic waveguide beam steering device. The electro-optic waveguide beam steering device steers an outgoing optical beam to one of the one or more ground stations based on the voltage.

Chao, Tien-Hsin↗

Experimental Limit on Optical-Photon Coupling to Light Neutral Scalar Bosons

We report on the first results of a sensitive search for scalar coupling of photons to a light neutral boson in the mass range of approximately 1.0 meV (milli-electron volts) and coupling strength greater than 10{sup -6} GeV{sup -1} using optical photons. This was a photon regeneration experiment using the 'light shining through a wall' technique in which laser light was passed through a strong magnetic field upstream of an optical beam dump; regenerated laser light was then searched for downstream of a second magnetic field region optically shielded from the former. Our results show no evidence for scalar coupling in this region of parameter space.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical cross beam field tests at ESSA Haswell Field site, October 1969

A series of tests with both the visible and IR optical cross beam systems was made at the Haswell, Colorado, Field Site of ESSA. This memorandum covers only the details of the test setup and runs. A joint field test program was undertaken by ESSA at a 164 meter (500 foot) meteorological tower. The tower was instrumented with wind sensors, temperature sensors, temperature sensors, fluctuating wind and temperature sensors and humidity sensors. The sensors were located at three elevations: 42, 192 and 162 meters. A movable elevator was also instrumented and could be positioned at any desired location along the tower height. The main object of the cross beam studies was to compare the visible and IR systems. The instruments were also arranged so that direct comparison with the sensors on the tower can be made.

Sandborn, V. A.↗

Scaling device for photographic images

A scaling device projects a known optical pattern into the field of view of a camera, which can be employed as a reference scale in a resulting photograph of a remote object, for example. The device comprises an optical beam projector that projects two or more spaced, parallel optical beams onto a surface of a remotely located object to be photographed. The resulting beam spots or lines on the object are spaced from one another by a known, predetermined distance. As a result, the size of other objects or features in the photograph can be determined through comparison of their size to the known distance between the beam spots. Preferably, the device is a small, battery-powered device that can be attached to a camera and employs one or more laser light sources and associated optics to generate the parallel light beams. In a first embodiment of the invention, a single laser light source is employed, but multiple parallel beams are generated thereby through use of beam splitting optics. In another embodiment, multiple individual laser light sources are employed that are mounted in the device parallel to one another to generate the multiple parallel beams.

Rivera, Jorge E.↗

Method for using polarization gating to measure a scattering sample

Described herein are systems, devices, and methods facilitating optical characterization of scattering samples. A polarized optical beam can be directed to pass through a sample to be tested. The optical beam exiting the sample can then be analyzed to determine its degree of polarization, from which other properties of the sample can be determined. In some cases, an apparatus can include a source of an optical beam, an input polarizer, a sample, an output polarizer, and a photodetector. In some cases, a signal from a photodetector can be processed through attenuation, variable offset, and variable gain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatiotemporal Structure in Intense THz Pulsed Beams

Optically generated terahertz radiation, with gigavolt per meter (GV/m) electric fields accessible in tabletop experiments, provides a promising source of accelerating gradients for future particle accelerator applications. Manipulation and characterization of radiation is essential for efficiently producing high fields and effectively delivering them to an accelerating structure or interaction region. The talk will cover a method of generating and characterizing high quality and structured terahertz pulsed laser beams for compact particle acceleration.

Hine, George↗

Optical domain analog to digital conversion methods and apparatus

Methods and apparatus for optical analog to digital conversion are disclosed. An optical signal is converted by mapping the optical analog signal onto a wavelength modulated optical beam, passing the mapped beam through interferometers to generate analog bit representation signals, and converting the analog bit representation signals into an optical digital signal. A photodiode receives an optical analog signal, a wavelength modulated laser coupled to the photodiode maps the optical analog signal to a wavelength modulated optical beam, interferometers produce an analog bit representation signal from the mapped wavelength modulated optical beam, and sample and threshold circuits corresponding to the interferometers produce a digital bit signal from the analog bit representation signal.

47 OTHER INSTRUMENTATION↗

Fast wavelength tuning techniques for external cavity lasers

An apparatus comprising a laser source configured to emit a light beam along a first path, an optical beam steering component configured to steer the light beam from the first path to a second path at an angle to the first path, and a diffraction grating configured to reflect back at least a portion of the light beam along the second path, wherein the angle determines an external cavity length. Included is an apparatus comprising a laser source configured to emit a light beam along a first path, a beam steering component configured to redirect the light beam to a second path at an angle to the first path, wherein the optical beam steering component is configured to change the angle at a rate of at least about one Kilohertz, and a diffraction grating configured to reflect back at least a portion of the light beam along the second path.

47 OTHER INSTRUMENTATION↗

PROTOPLASMA - Proton-driven plasma-wakefield experiment at Fermilab: Stages and approach

Generation of TeV-scale electron beams using conventional RF technology appears expensive for building the next generation of colliders. Proton-driven plasma-wakefield acceleration of electrons promises an alternative route to generate TeV-scale electron beams using existing proton machines. PROTOPLASMA is the proposed R and D project at Fermilab that plans to use a proton beam driven plasma-wakefield to accelerate electrons. The project is planned in stages with the project's path guided by simulations. First, a 60-120 GeV proton beam will be injected into 1-2 meters of plasma to observe selfmodulation instability in the proton beam. Next, an injected 5 MeV electron beam will be accelerated by the plasma. In this paper, we report on the basic project plan and outline our staged approach. We report on first simulation results that show self-modulation of a proton bunch and discuss beam optics requirements and other limits.

43 PARTICLE ACCELERATORS↗

Discriminating quantum-optical beam-splitter channels with number-diagonal signal states: Applications to quantum reading and target detection

We consider the problem of distinguishing, with minimum probability of error, two optical beam-splitter channels with unequal complex-valued reflectivities using general quantum probe states entangled over M signal and M' idler mode pairs of which the signal modes are bounced off the beam splitter while the idler modes are retained losslessly. We obtain a lower bound on the output state fidelity valid for any pure input state. We define number-diagonal signal (NDS) states to be input states whose density operator in the signal modes is diagonal in the multimode number basis. For such input states, we derive series formulas for the optimal error probability, the output state fidelity, and the Chernoff-type upper bounds on the error probability. For the special cases of quantum reading of a classical digital memory and target detection (for which the reflectivities are real valued), we show that for a given input signal photon probability distribution, the fidelity is minimized by the NDS states with that distribution and that for a given average total signal energy N{sub s}, the fidelity is minimized by any multimode Fock state with N{sub s} total signal photons. For reading of an ideal memory, it is shown that Fock state inputs minimize the Chernoff bound. For target detection under high-loss conditions, a no-go result showing the lack of appreciable quantum advantage over coherent state transmitters is derived. A comparison of the error probability performance for quantum reading of number state and two-mode squeezed vacuum state (or EPR state) transmitters relative to coherent state transmitters is presented for various values of the reflectances. While the nonclassical states in general perform better than the coherent state, the quantitative performance gains differ depending on the values of the reflectances. The experimental outlook for realizing nonclassical gains from number state transmitters with current technology at moderate to high values of the reflectances is argued to be good.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗