Search NASA⌕ Search

SEARCH · Search NASA

Results for “Background subtraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Probing the Reverse Shock in an Oxygen-Rich Supernova Remnant

The aim of this proposal was to examine the O VI emission at three positions around the X-ray bright ring of the remnant in order to investigate the relation between the O VI emission, the X-ray O VII and O VIII emission, and the optical [O III] emission, and how these vary around the rim of the remnant. So far, only one Far Ultraviolet Spectroscopic Explorer (FUSE) pointing at the remnant has been performed, together with the background pointing needed to subtract the diffuse scattered light from nearby O stars. The data were recalibrated using the CalFUSE calibration pipeline, but the emission is faint enough that hand processing will be needed for this pointing to optimize the extraction. Rereduction of the data is underway. A postdoctoral fellow has also been hired, and in part she will assist with the analysis.

Sonneborn, George↗

Software Compensates Electronic-Nose Readings for Humidity

A computer program corrects for the effects of humidity on the readouts of an array of chemical sensors (an "electronic nose"). To enable the use of this program, the array must incorporate an independent humidity sensor in addition to sensors designed to detect analytes other than water vapor. The basic principle of the program was described in "Compensating for Effects of Humidity on Electronic Noses" (NPO-30615), NASA Tech Briefs, Vol. 28, No. 6 (June 2004), page 63. To recapitulate: The output of the humidity sensor is used to generate values that are subtracted from the outputs of the other sensors to correct for contributions of humidity to those readings. Hence, in principle, what remains after corrections are the contributions of the analytes only. The outputs of the non-humidity sensors are then deconvolved to obtain the concentrations of the analytes. In addition, the humidity reading is retained as an analyte reading in its own right. This subtraction of the humidity background increases the ability of the software to identify such events as spills in which contaminants may be present in small concentrations and accompanied by large changes in humidity.

Zhou, Hanying↗

Applications of OMI Tropospheric NO(Sub 2) Data: Air Quality Trends in the US and Lightning NO(x) Source Strength

This talk will be presented in two parts: 1) an analysis of tropospheric column NO2 trends in the eastern half of the United States over the period 2005 to 2009 and 2) estimation of lightning NO(x) production rates based on OMI observations and lightning flash rate data. The air quality trends in the eastern US will be determined for specific subregions using tropospheric column NO2 data from OMI for 2005 through 2008 and from GOME-2 for 2007 through 2009. This period is characterized by significant NO(x) emission reductions at power plants within most of this region. The air quality trends will be compared with those estimated from continuous emission monitoring data from the power plants compiled by the US Environmental Protection Agency. OMI NO2 data have also been used to estimate lightning NOx production per flash in selected storms near Costa Rica and Panama during the 2007 NASA TC4 field campaign and over the continental US, Gulf of Mexico, and western Atlantic during the summers of 2005 and 2006. The lightning signal is extracted from the OMI data through a custom retrieval in which an NO2 profile representative of convective outflow is used in the airmass factor calculation and the background NO2 column is subtracted from the tropospheric column. When combined with NO(x)/NO2 ratios from the NASA GMT model and observed flash rates, the resulting estimates of NO(x) production per flash are comparable to those estimated obtained from analyses of aircraft data and cloud-resolving modeling.

Pickering, Kenneth↗

An Algorithm for the Fitting of Planet Models to Kepler Light Curves

We describe an algorithm which fits model planetary system parameters to light curves from Kepler Mission target stars. The algorithm begins by producing an initial model of the system which is used to seed the fit,with particular emphasis on obtaining good transit timing parameters. An attempt is then made to determine whether the observed transits are more likely due to a planet or an eclipsing binary. In the event that the transits are consistent with a transiting planet, an iterative fitting process is initiated: a wavelet-based whitening filter is used to eliminate stellar variations on timescales long compared to a transit; a robust nonlinear fitter operating on the whitened light curve produces a new model of the system; and the procedure iterates until convergence upon a self-consistent whitening filter and planet model. The fitted transits are removed from the light curve anda search for additional planet candidates is performed upon the residual light curve. The fitted models are used in additional tests which identify false positive planet detections: multiple planet candidates with near-identical fitted periods are far more likely to be an eclipsing binary, for example, while target stars in which the model lightcurve is correlated with the star centroid position may indicate a background eclipsing binary, and subtraction of all model planet candidates yields a light curve of pure noise and stellar variability, which can be used to study the probability that the planet candidates result from statistical fluctuations in the data.

Exoplanet↗

Angular Distribution of Dimuons from Drell-Yan Production in p+Fe Interactions at 120 GeV Beam Energy

In the E906/SeaQuest Fermilab experiment, we report a measurement of the angular distributions by measuring the angular parameters $\lambda$, $\mu$, and $\nu$ of Drell-Yan dimuons produced using a 120 GeV proton beam incident on an iron target. The angular distribution in the naive Drell-Yan model does not show any $\cos2\phi$ dependency, where $\phi$ denotes the azimuthal angle of dimuons in the Collins-Soper frame. However, pion-induced Drell-Yan experiments, such as NA10 and E615, have observed a significant dependence on $\cos2\phi$. The Boer–Mulders function, a transverse momentum-dependent distribution function, represents the correlation between the transverse spin and the transverse momentum of the quark. A non-zero Boer-Mulders function or an improved higher-order Drell-Yan model considering QCD effects can produce a $\cos 2\phi$ modulation in the Drell-Yan angular distribution. To measure the angular distributions, we have used an event mixing method to construct the combin atorial background, which was then subtracted from the data to isolate the Drell-Yan signal. Following this, we corrected the detector, trigger, and reconstruction efficiencies using a doubly-iterative Bayesian Unfolding method. This iterative unfolding technique improves the response matrix based on the results of the previous unfolding step, ensuring robust convergence without exaggeration of uncertainties. The angular distributions of the dimuons were measured over the invariant mass range $5.0 < M_{\mu^+ \mu^-} < 8.0$ $GeV/c^2$, with dimuon transverse momentum $P_T < 2$ GeV/c and Feynman-x $-0.18 < x_F < 0.9$. The measured angular distributions are then compared with the QCD calculations for $p + \text{Fe}$ interactions, and proton-induced angular distribution measurements from other experiments. We have observed weak $\cos 2\phi$ modulations as a function of $P_T$. For $P_T > 1.0 \, \text{GeV}/c$, the predicted NNLO perturbative QCD value of $\nu$ is larger than what we have me asured at E906/SeaQuest. Moreover, we have not observed a strong dependence of $\nu$ on the kinematic variables, such as dimuon mass $M_{\mu^+ \mu^-}$ and Bjorken-$x$. The spin alignment of the virtual photon, $\lambda$, measured from the SeaQuest Drell-Yan $p+\text{Fe}$ data, is found to be strongly dependent on $P_T$, decreasing as $P_T$ increases. $\lambda$ also holds to the upper bound condition $\lambda < 1.0$ within the statistical uncertainty, showing a trend similar to that predicted by NNLO perturbative QCD. However, for $1.0 < P_T < 2.0 \, \text{GeV}/c$, the extracted $\lambda$ value from SeaQuest is smaller than that predicted by perturbative QCD at NNLO.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Techniques for removing non-uniform background in coded-aperture imaging on the energetic X-ray imaging telescope experiment

It is found that the subtractive flat field technique for nonuniform background illumination is generally effective at removing background systematics for stationary mask experiments such as the Energetic X-ray Imaging Experiment. The time dependence of intensity and the two-dimensional shape of the background detector image during the flight are explored. A flat field image is constructed from observations where X-ray sources were absent from the field of view. It is shown that this technique can successfully reduce rms fluctuations to within a few percent of ideal Poisson statistics. The quality of the flat field does not appear to be a strong function of radius and can be used effectively out to the edge of the detector to remove the strong background ring.

Covault, C. E.↗

Effect of color coding and subtraction on the accuracy of contrast echocardiography

BACKGROUND: Contrast echocardiography may be used to assess myocardial perfusion. However, gray scale assessment of myocardial contrast echocardiography (MCE) is difficult because of variations in regional backscatter intensity, difficulties in distinguishing varying shades of gray, and artifacts or attenuation. We sought to determine whether the assessment of rest myocardial perfusion by MCE could be improved with subtraction and color coding. METHODS AND RESULTS: MCE was performed in 31 patients with previous myocardial infarction with a 2nd generation agent (NC100100, Nycomed AS), using harmonic triggered or continuous imaging and gain settings were kept constant throughout the study. Digitized images were post processed by subtraction of baseline from contrast data and colorized to reflect the intensity of myocardial contrast. Gray scale MCE alone, MCE images combined with baseline and subtracted colorized images were scored independently using a 16 segment model. The presence and severity of myocardial contrast abnormalities were compared with perfusion defined by rest MIBI-SPECT. Segments that were not visualized by continuous (17%) or triggered imaging (14%) after color processing were excluded from further analysis. The specificity of gray scale MCE alone (56%) or MCE combined with baseline 2D (47%) was significantly enhanced by subtraction and color coding (76%, p<0.001) of triggered images. The accuracy of the gray scale approaches (respectively 52% and 47%) was increased to 70% (p<0.001). Similarly, for continuous images, the specificity of gray scale MCE with and without baseline comparison was 23% and 42% respectively, compared with 60% after post processing (p<0.001). The accuracy of colorized images (59%) was also significantly greater than gray scale MCE (43% and 29%, p<0.001). The sensitivity of MCE for both acquisitions was not altered by subtraction. CONCLUSION: Post-processing with subtraction and color coding significantly improves the accuracy and specificity of MCE for detection of perfusion defects.

Multicenter Study↗

Observations of interstellar helium with a gas absorption cell - Limits on the bulk velocity of the interstellar medium

Results are reported for observations of solar 584-A flux resonantly scattered by the 1s(2)-1s2p transition of neutral interstellar helium. A photometer equipped with a helium gas-absorption cell and flown aboard a sounding rocket to a peak altitude of 185 km was employed to observe the sky in Perseus. The data reduction procedure is described, including subtraction of the terrestrial atmospheric background, calculation of the solar flux, and reduction of the number density of scatters to a function of phase-space parameters of the local interstellar medium. The ratio of 584-A fluxes observed with the gas cell full and empty is computed and compared with numerical models of the interstellar-helium flow through the solar system. The results show that the bulk speed of the distant interstellar medium with respect to the sun is unlikely to be less than 10 to 15 km/s, at the 2-sigma level. Since this value is inconsistent with results obtained from Lyman-alpha observations, it is suggested that either the total ionization rate for helium is variable or present models of the behavior of the local interstellar medium need further refinement.

Freeman, J.↗

Exospheric temperatures deduced from 7320- to 7330-A /O/+//2P/ - O/+//2D// twilight observations

A technique developed to deduce exospheric temperatures from the 7320- to 7330-A emission measured by the visible airglow experiment on board the AE-E satellite is considered. An excess emission in the measured 7320- to 7330-A brightness is noticed as a result of the interaction between the spacecraft and the atmosphere. The observed brightnesses are corrected for this effect. The galactic background emission is also carefully subtracted. The deduced temperatures exhibit a positive correlation with solar activity. It varies from approximately 700 K in late 1976 to approximately 1700 K at the peak of this solar cycle. The presence of a nonthermal oxygen corona is considered inconclusive.

Yee, J. H.↗

X-Raying Molecular Clouds

Dense interstellar clouds are known to consist almost entirely of molecular hydrogen gas which is, however, normally not observable directly. We have developed a new method for measuring gas column density through its X-ray absorption. The latest data analysis software has been implemented to correct for both exposure and flat- fielding and to subtract various non-cosmic background from individual images. The ROSAT PSPC observations on the R CrA cloud have been merged into maps in three broad energy bands, with corrections for residual differential background between the observations. Individual sources have been detected and removed from these maps. We have then applied the shadowing technique to derive the first column density map based on X-ray data alone. We have conducted various tests to access systematic errors, including possible background intensity variations. We have also proposed a NRAO 12m telescope mapping of the CO distribution in the R CrA cloud. This mapping will supplement our X-ray measurement to allow for a direct calibration of the Co-to-H2 conversion ratio. We use a multi-energy band X-ray shadowing technique to measure the total column density distribution of molecular clouds.

Wang, Q. Daniel↗

Isokinetic TWC Evaporator Probe: Development of the IKP2 and Performance Testing for the HAIC-HIWC Darwin 2014 and Cayenne-2015 Field Campaigns

A new Isokinetic Total Water Content Evaporator (IKP2) was downsized from a prototype instrument, specifically to make airborne measurements of hydrometeor total water content (TWC) in deep tropical convective clouds to assess the new ice crystal Appendix D icing envelope. The probe underwent numerous laboratory and wind tunnel investigations to ensure reliable operation under the difficult high altitude/speed/TWC conditions under which other TWC instruments have been known to either fail, or have unknown performance characteristics. The article tracks the testing and modifications of the IKP2 probe to ensure its readiness for three flight campaigns in 2014 and 2015. Comparisons are made between the IKP2 and the NASA Icing Research Tunnel reference values in liquid conditions, and to an exploratory technique estimating ice water content from a bulk ice capture cylinder method in glaciated conditions. These comparisons suggest that the initial target of 20 percent accuracy in TWC has been achieved and likely exceeded for tested TWC values in excess of about 0.5 gm (exp -3). Uncertainties in the ice water content reference method have been identified. Complications are introduced in the necessary subtraction of an independently measured background water vapour concentration, errors of which are small at the colder flight temperatures, but increase rapidly with increasing temperature, and ultimately limit the practical use of the instrument in a tropical convective atmosphere to conditions colder than about 0 degrees C. A companion article in this conference traces the accuracy of the components of the IKP2 to derive estimated system accuracy.

Meteorological Instruments↗

Isokinetic TWC Evaporator Probe: Development of the IKP2 and Performance Testing for the HAIC-HIWC Darwin 2014 and Cayenne 2015 Field Campaigns

A new Isokinetic Total Water Content Evaporator (IKP2) was downsized from a prototype instrument, specifically to make airborne measurements of hydrometeor total water content (TWC) in deep tropical convective clouds to assess the new ice crystal Appendix D icing envelope. The probe underwent numerous laboratory and wind tunnel investigations to ensure reliable operation under the difficult high altitude/speed/TWC conditions under which other TWC instruments have been known to either fail, or have unknown performance characteristics. The article tracks the testing and modifications of the IKP2 probe to ensure its readiness for three flight campaigns in 2014 and 2015. Comparisons are made between the IKP2 and the NASA Icing Research Tunnel reference values in liquid conditions, and to an exploratory technique estimating ice water content from a bulk ice capture cylinder method in glaciated conditions. These comparisons suggest that the initial target of 20% accuracy in TWC has been achieved and likely exceeded for tested TWC values in excess of about 0.5/cu gm. Uncertainties in the ice water content reference method have been identified. Complications are introduced in the necessary subtraction of an independently measured background water vapor concentration, errors of which are small at the colder flight temperatures, but increase rapidly with increasing temperature, and ultimately limit the practical use of the instrument in a tropical convective atmosphere to conditions colder than about 0 C. A companion article in this conference traces the accuracy of the components of the IKP2 to derive estimated system accuracy.

Meteorological Instruments↗

1024 x 1024 pixel mid-wavelength and long-wavelength infrared QWIP focal plane arrays for imaging applications

Mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) 10(24) x 10(24) pixel quantum well infrared photodetector (QWIP) focal planes have been demonstrated with excellent imaging performance. The MWIR QWIP detector array has demonstrated a noise equivalent differential temperature (NEAT) of 17 mK at a 95 K operating temperature with f/2.5 optics at 300 K background and the LWIR detector array has demonstrated a NEAT of 13 mK at a 70 K operating temperature with the same optical and background conditions as the MWIR detector array after the subtraction of system noise. Both MWIR and LWIR focal planes have shown background limited performance (BLIP) at 90 K and 70 K operating temperatures respectively, with similar optical and background conditions. In this paper, we will discuss the performance in terms of quantum efficiency, NE(delta)T, uniformity, operability and modulation transfer functions.

uniformity↗

1024x1024 Pixel MWIR and LWIR QWIP Focal Plane Arrays and 320x256 MWIR:LWIR Pixel Colocated Simultaneous Dualband QWIP Focal Plane Arrays

Mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) 1024x1024 pixel quantum well infrared photodetector (QWIP) focal planes have been demonstrated with excellent imaging performance. The MWIR QWIP detector array has demonstrated a noise equivalent differential temperature (NE(Delta)T) of 17 mK at a 95K operating temperature with f/2.5 optics at 300K background and the LWIR detector array has demonstrated a NE(Delta)T of 13 mK at a 70K operating temperature with the same optical and background conditions as the MWIR detector array after the subtraction of system noise. Both MWIR and LWIR focal planes have shown background limited performance (BLIP) at 90K and 70K operating-temperatures respectively, with similar optical and background conditions. In addition, we are in the process of developing MWIR and LWIR pixel collocated simultaneously readable dualband QWIP focal plane arrays.

quantum wells↗

Towards Dualband Megapixel QWIP Focal Plane Arrays

Mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) 1024 x 1024 pixel quantum well infrared photodetector (QWIP) focal planes have been demonstrated with excellent imaging performance. The MWIR QWIP detector array has demonstrated a noise equivalent differential temperature (NEDT) of 17 mK at a 95 K operating temperature with f/2.5 optics at 300 K background and the LWIR detector array has demonstrated a NEDT of 13 mK at a 70 K operating temperature with the same optical and background conditions as the MWIR detector array after the subtraction of system noise. Both MWIR and LWIR focal planes have shown background limited performance (BLIP) at 90 K and 70 K operating temperatures respectively, with similar optical and background conditions. In addition, we have demonstrated MWIR and LWIR pixel co-registered simultaneously readable dualband QWIP focal plane arrays. In this paper, we will discuss the performance in terms of quantum efficiency, NEDT, uniformity, operability, and modulation transfer functions of the 1024 x 1024 pixel arrays and the progress of dualband QWIP focal plane array development work.

Infrared detectors↗

Parafoveal Target Detectability Reversal Predicted by Local Luminance and Contrast Gain Control

This project is part of a program to develop image discrimination models for the prediction of the detectability of objects in a range of backgrounds. We wanted to see if the models could predict parafoveal object detection as well as they predict detection in foveal vision. We also wanted to make our simplified models more general by local computation of luminance and contrast gain control. A signal image (0.78 x 0.17 deg) was made by subtracting a simulated airport runway scene background image (2.7 deg square) from the same scene containing an obstructing aircraft. Signal visibility contrast thresholds were measured in a fully crossed factorial design with three factors: eccentricity (0 deg or 4 deg), background (uniform or runway scene background), and fixed-pattern white noise contrast (0%, 5%, or 10%). Three experienced observers responded to three repetitions of 60 2IFC trials in each condition and thresholds were estimated by maximum likelihood probit analysis. In the fovea the average detection contrast threshold was 4 dB lower for the runway background than for the uniform background, but in the parafovea, the average threshold was 6 dB higher for the runway background than for the uniform background. This interaction was similar across the different noise levels and for all three observers. A likely reason for the runway background giving a lower threshold in the fovea is the low luminance near the signal in that scene. In our model, the local luminance computation is controlled by a spatial spread parameter. When this parameter and a corresponding parameter for the spatial spread of contrast gain were increased for the parafoveal predictions, the model predicts the interaction of background with eccentricity.

Ahumada, Albert J., Jr.↗

Differential optical proximity detector

Updated detector can operate under ambient light and uses multiple detectors to locate objects in several different spacial volumes. Sensitivity is approved by scanning field-of-view twice: once with coherent light source turned on and once with background light only. Detector outputs for two cases are amplified and subtracted for each photodiode sensor in array, to eliminate effect of background light.

Johnston, A. R.↗

Analysis prcedures for ROSAT XRT/PSPC observations of extended objects and the diffuse background

Proper reduction of ROSAT observations of extended sources or the diffuse background requires techniques that are quite different from the standard point-source analysis. We describe in detail an appropriate set of procedures for this purpose for the X-ray Telescope (XRT), Position Sensitive Proportional Counter (PSPC). We define a standard set of pulse-height bands recommended for analyzing extended structure and describe the use of detector efficiency maps for proper flat-fielding of images. Sources of noncosmic background contamination and their modeling and subtraction are discussed and demonstrated. IDL routines for implementing these data reduction procedures are being made available to the community through the ROSAT IDL library maintained at Goddard Space Flight Center (GSFC).

Snowden, S. L.↗