Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bagging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Self-Healing Polymer-Modified Cements for Ambient-Temperature Applications

We present two novel polymer-modified cement formulations which can self-heal cement microfractures at ambient temperature. The polymers used are either commercially available boric acid gel (BAG) or a synthesized polymer MBA-BDA. This report summarizes the progress of developing polymer-modified cement formulations. The polymers used are either commercially available or synthesized in house. Results show two formulations (commercial boric acid gel BAG and as-synthesized polymer MBA-BDA), both with potential to bring about room-temperature self-healing to conventional cement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lifetime extension drop-test of real-world corroded 5 Quart Hagan nuclear material storage container

A 5Qt Hagan container with a 20-year history of nuclear material storage was challenged with three successive drop tests at a height of 3.7 meters. The total mass of the test package was 12.1 kg. The 1st and 2nd drop tests (center of gravity over the container bottom corner but 180 degrees apart on the container bottom face) passed the pre- and post- impact helium leak criterion at less than 1.00E-6 atm-cc/sec (ambient cubic centimeters per second). The 3rd and final test (center of gravity over top corner) failed with a post-impact gross leak of 1.1E-1 atmcc/sec. The RRFMC (Respirable Release Fraction Measurement Chamber) is a drop tower test system that is critical for the sustainability of the SAVY-4000™ series and Hagan-type (NFT Inc. Golden CO) nuclear material storage containers. These are the primary in-use nuclear material storage container types at the Los Alamos National Laboratory TA-55 facility. Results are presented to expand the technical knowledge basis for container lifetime, regarding actual exposure to corrosive gas species on the container inner surfaces. The primary source of general corrosion throughout the container is gaseous hydrogen chloride (HCl). This gas is generated by the degradation of the polyvinylchloride (PVC) bag-out bag. Additionally, in most cases, the nuclear material itself also releases HCl gas (due to residual chemical components associated with the material formation). The RRFMC drop tower gives the end-user the ability record and analyze high-speed video and photography and if needed aerosol mass release measurements. In this report the principal issue is the physical deformation of the 5Qt Hagan container. There were no mass release experiments of test aerosol mass in the present study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Analysis of 121103072 (SAVY-4000)

A surveillance feedlist for fiscal year (FY) 2022 was developed with the intent to target containers with contents known to generate corrosive gasses. One SAVY-4000 (hereafter “SAVY”) container with a serial number 121103072 was selected due to the reasonable wattage and known molten salt extraction (MSE) material corrosive behavior. The material was measured at 3.08 W with approximately 200 g of material placed inside of the SAVY for 6.07 years. The inner packaging configuration included a ¼ Qt stainless steel slip top inner container and a sPVC bag-out bag enclosing the inner container. Visual observations of the container during retrieval revealed several concerning features on the exterior of the container, notably on the lid. Fig. 1 shows the container lid along with an inset image further magnifying the features of interest. The corroded tamper indicating device (TID) wire and the corroded radioactive material tag wire indicated that corrosive gas species for steel were produced during storage. Although the TID wire and rad tag wire are not the same composition as the SAVY body and lid, these are often used as an indicator of potential corrosion inside of the SAVY container. The oxide residing inside of the filter holes and significant buildup around one hole provided further evidence supporting the presence of corrosive species inside of the container.

36 MATERIALS SCIENCE↗

Development of Scalable Coastal and Offshore Macroalgal Farming

The US DOE/ARPA-E MARINER program funded a four-year project to determine an optimal way to grow kelps in large, nearshore and offshore arrays for the eventual purpose of biofuel production with the goal of keeping the cost below $\$$80 USD per dry metric ton of kelp. This project specifically looked at how Saccharina latissima can be grown in the Gulf of Alaska to reach that goal. There were three major aspects of the research: 1) optimizing nursery production and seeding lines for outplanting, 2) designing an economical, modular outplanting structure and 3) developing methods to efficiently harvest the product. Farm designs were based on catenary structures and the use of spreader bars with variable spacing of grow lines and line types. The spacing of the grow lines makes a difference in the yield. Grow line spacing of ≥1.5m showed about a 50% increase in kg/m. There was no statistical difference in the growth of Saccharina latissima whether in the middle or the outside of the array, but the line type and perhaps line thickness can make a difference in yield. Sagging caused by the weight of the mature fronds resulted in lower growth at depth. Various harvesting approaches for mature kelps were tested by collaborating farmers. One promising innovation is the use of large bags for holding the freshly harvested fronds. Although the weight of the fronds on the growlines causes the lines to sink, the bags packed with the harvested fronds float, allowing for easy loading to the transfer vessel. Another advance in harvesting is a specially built harvest vessel, the Harvest Buddy, allowing a more mechanized and faster way to harvest. A significant aspect of this project was the TTO/T2M. Several different outreach activities were performed by the Alaska Fisheries Development Foundation and GreenWave. A techno-economic assessment (TEA) using our data has pointed to solutions to reach the $\$$80 goal. A second phase of this project involved the co-culture of two different species of kelps. Interest in farming kelps has grown beyond using kelp for food, feed or biofuels. There is considerable interest in generating biomass from seaweed for use in bioplastics and other products that would substitute for petroleum-derived products. For these uses to be viable, large amounts of biomass are needed. Very large kelp farms can be expensive to build and maintain, leading to the need to optimize the biomass per unit area. Although close spacing of growlines can lead to poor growth, a viable approach may be to grow two species of kelps together: one that hangs down and one that is buoyant, growing up. This system would increase the spacing in three dimensions. In Alaska, Saccharina latissima is commonly grown hanging down from longlines. One of the buoyant Alaskan kelps is Nereocystis luetkeana. Because there are commercial uses for wild-harvested Nereocystis in Alaska, we undertook a preliminary trial in Kodiak, Alaska that grew both Saccharina and Nereocystis in the same longline array. Closely spaced lines were seeded the first week of February 2023 and set at 3m below the surface. The arrays were harvested in late June 2023. Despite having 45% fewer grow-lines, the total yield of the Nereocystis on the combined arrays was statistically similar to the Nereocystis only arrays. Total yields were greatest on the combined arrays, followed by the Nereocystis only and Saccharina only arrays. These results may have significance for large scale macroalgal production.

09 BIOMASS FUELS↗

Laser Confocal Microscopy Uncertainty Quantification Study

At Los Alamos National Laboratory (LANL), the Storage Safety and Engineering (SSE) team completes annual surveillance on a subset of in-use interim nuclear material storage containers in fulfilment of requirements outlined in DOE Manual M 441.1-1. The containers are selected through several methods, such as subject matter expert judgement, random selection, and trending items. Following these selections, the SSE team has the capacity to complete surveillance on 15-20 containers each fiscal year, composed of a combination of SAVY-4000 and Hagan storage containers. Through previous work, the stainless-steel components of the containers have been identified as life limiting components, with an emphasis on the thin-walled bodies. The team is focused on understanding the extent of general and pitting corrosion, due to observations of extensive corrosion from stored contents and bag-out-bag degradation. Quantifying corrosion effects on the thin-walled stainless steel container bodies, and understanding potential impacts to the respective design release rates and design qualification release rates is paramount to the team. To date, destructive examination (DE) has proven to be the most insightful method for developing an understanding on the extent of corrosion on used containers. To standardize this process, the SSE team developed a destructive examination guide for analyzing stainless steel components of the containers. Corroded containers of interest are identified during surveillance activities and set aside for sectioning and characterization. Following sectioning, a major step in the DE workflow is the utilization of laser confocal microscopy for scanning corroded samples of interest and extracting data on pits, such as count, depth, and equivalent diameter. Adhering to the techniques outlined in the DE guide, analysis has been completed on two Hagans and one SAVY-4000 container, with the maximum pit depth recorded as 139.1 ± 22.82 μm on a 17.5 year old Hagan. The findings from the completed destructive examinations will be utilized to support lifetime extension efforts of the SAVY-4000 as the team can better estimate corrosion rates and effects over time based on stored contents and age. Due to the implications of observing extreme pit depths that approach the nominal container body thickness of .0299 inches (0.759 mm) or minimum container thickness of 0.236” (0.6 mm), high confidence in the LCM measurements is desired. Through testing outlined in, it was concluded that the total error ascribed to the 20x objective when conducting large image mapping on the Keyence VK-X3050 laser confocal microscope (LCM) relative to a 50x objective (reference) is 16.4% (± 8.73%). For shallow features on the order of pristine SAVY surface defects (i.e. 5 μm), this uncertainty is appropriate. However, this conservative estimate of total error poses a fundamental concern for pit depths that approach the thickness of the measured samples. That is, with the measurement uncertainty currently employed on all measurements, the LCM would be unable to resolve if a pit with a depth of 515 μm is through wall. Standard step height samples were procured and used in the present study to assess the resolution and repeatability of height measurements. Understanding the resolution and repeatability of height measurements was the first focus of the team as it relates directly to pit depth, which is of primary concern. Calibration gratings were procured to evaluate the resolution and repeatability of measurements in the X and Y axes of the LCM stage. The results of the depth uncertainty study were conducted first and presented in the subsequent sections. The planar uncertainty study is appended to the depth study with conclusions from both summarized at the end of the report.

36 MATERIALS SCIENCE↗

Data from "What regulates decomposition in agroecosystems? Insights from reading the tea leaves"

Litter decomposition is a critical Earth process, recycling nutrients and setting a portion of plant tissue on a path toward soil organic matter. Despite this importance, we still lack a good understanding of local factors that regulate decomposition, especially in agroecosystems where management plays an outsized role. To help understand these factors, 1308 tea bags containing green and rooibos tea leaves were buried in 109 plots being exposed to a variety of management practices. This dataset contains the decomposition measurements (mass) of those tea bags that were collected 6 times during the 2018 growing season at 9 long-term experimental farms in Iowa, USA. Additionally, the dataset contains a variety of soil and crop measurements to support the understanding of the soils and the decomposition measurements. Files are presented in .csv format.

Agricultural land management↗

Facile Synthesis of a Broad Range of Colloidal Nanocrystals by Membrane-Mediated pH Gradient under Ambient Conditions

We report a simple synthesis process for a wide variety of ultrasmall nanocrystals. Simply immersing a dialysis bag containing an aqueous solution of a metal salt mixed with citric acid in a NaOH solution reservoir for 10 min, nanocrystals measuring only a few nanometers in size are formed inside the dialysis bag. We demonstrated the synthesis of ultrasmall nanocrystals of Co, Ni, Cu, Ag, Au, Pd, Cu 2 O, FeO, and CeO 2 , and found that the gradual change in pH caused by the diffusion of OH – ions through the dialysis membrane played an essential role in the formation of these nanocrystals. This method can be readily adapted for almost all transition metal elements, providing researchers in the fields of catalysis and nanomedicine an easy access to a wide range of ultrasmall metal and oxide nanocrystals.

36 MATERIALS SCIENCE↗

Using Ultrasound Image Augmentation and Ensemble Predictions to Prevent Machine-Learning Model Overfitting

Deep learning predictive models have the potential to simplify and automate medical imaging diagnostics by lowering the skill threshold for image interpretation. However, this requires predictive models that are generalized to handle subject variability as seen clinically. Here, we highlight methods to improve test accuracy of an image classifier model for shrapnel identification using tissue phantom image sets. Using a previously developed image classifier neural network—termed ShrapML—blind test accuracy was less than 70% and was variable depending on the training/test data setup, as determined by a leave one subject out (LOSO) holdout methodology. Introduction of affine transformations for image augmentation or MixUp methodologies to generate additional training sets improved model performance and overall accuracy improved to 75%. Further improvements were made by aggregating predictions across five LOSO holdouts. This was done by bagging confidences or predictions from all LOSOs or the top-3 LOSO confidence models for each image prediction. Top-3 LOSO confidence bagging performed best, with test accuracy improved to greater than 85% accuracy for two different blind tissue phantoms. This was confirmed by gradient-weighted class activation mapping to highlight that the image classifier was tracking shrapnel in the image sets. Overall, data augmentation and ensemble prediction approaches were suitable for creating more generalized predictive models for ultrasound image analysis, a critical step for real-time diagnostic deployment.

60 APPLIED LIFE SCIENCES↗

Inert-gas welding and brazing enclosure fabricated from sheet plastic

Custom-fabricated plastic bag maintains an inert-gas atmosphere for welding and brazing certain metals. The bag fits over part of the workpieces and the welding and brazing tools. It is also used for metal brazing and fusion plating which require an inert-gas atmosphere.

Wisner, J. P.↗

Chemical Method of Urine Volume Measurement

A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

QUANTITATIVE ANALYSIS↗

Design and development of pressure and repressurization purge system for reusable space shuttle multilayer insulation system

The manufacturing tasks for the program included the fabrication and assembly of an epoxy fiberglass purge bag to encapsulate an insulated cryogenic propellant tank. Purge, repressurization and venting hardware were procured and installed on the purge bag assembly in preparation for performance testing. The fabrication and installation of the superfloc multilayer insulation (MLI) on the cryogenic tank was accomplished as part of a continuing program. An abstraction of the results of the MLI fabrication task is included to describe the complete fabrication requirements for a reusable cryogenic propellant space storage system.

Source record↗

Advances in modeling aerodynamic decelerator dynamics.

The Viking entry vehicle uses a lines-first type of deployment in which the parachute, packed in a deployment bag, gets ejected rearward from the vehicle by a mortar. As the bag moves rearward, first the lines are unfurled and then the canopy. An analysis of the unfurling process is conducted, giving attention to longitudinal and rotational dynamics. It is shown that analytical modeling of aerodynamic systems provides significant information for a better understanding of the physics of the deployment process.

Whitlock, C. H.↗

Battery activation system

Initiator is fired to set off gas generator; gas flows into manifold and as gas pressure increases, chlorotrifluoroethylene diaphragms transfer force to polyethylene bags filled with electrolyte. Small membrane at base of each bag is ruptured, allowing electrolyte to flow into cells.

Sollo, C.↗

Fluid infusion system

Development of a fluid infusion system was undertaken in response to a need for an intravenous infusion device operable under conditions of zero-g. The initial design approach, pursued in the construction of the first breadboard instrument, was to regulate the pressure of the motive gas to produce a similar regulated pressure in the infusion liquid. This scheme was not workable because of the varying bag contact area, and a major design iteration was made. A floating sensor plate in the center of the bag pressure plate was made to operate a pressure regulator built into the bellows assembly, effectively making liquid pressure the directly controlled variable. Other design changes were made as experience was gained with the breadboard. Extensive performance tests were conducted on both the breadboard and the prototype device; accurately regulated flows from 6 m1/min to 100 m1/min were achieved. All system functions were shown to operate satisfactorily.

Hammond, J. C.↗

Breather cloth for vacuum curing

Finely-woven nylon cloth that has been treated with Teflon improves vacuum adhesive bonding of coatings to substrates. Cloth is placed over coating; entire assembly, including substrate, coating, and cloth, is placed in plastic vacuum bag for curing. Cloth allows coating to "breathe" when bag is evacuated. Applications include bonding film coatings to solar concentrators and collectors.

Reed, M. W.↗

Environmental exposure effects on composite materials for commercial aircraft

Activities reported include completion of the program design tasks, resolution of a high fiber volume problem and resumption of specimen fabrication, fixture fabrication, and progress on the analysis methodology and definition of the typical aircraft environment. Program design activities including test specimens, specimen holding fixtures, flap-track fairing tailcones, and ground exposure racks were completed. The problem experienced in obtaining acceptable fiber volume fraction results on two of the selected graphite epoxy material systems was resolved with an alteration to the bagging procedure called out in BAC 5562. The revised bagging procedure, involving lower numbers of bleeder plies, produces acceptable results. All required laminates for the contract have now been laid up and cured. Progress in the area of analysis methodology has been centered about definition of the environment that a commercial transport aircraft undergoes. The selected methodology is analagous to fatigue life assessment.

Hoffman, D. J.↗

Changes in vegetation spectra with deterioration of leaves under two methods of preservation

An experiment to measure changes in leaf spectra under different methods of preservation over time was conducted. The spectral measurements were made by a three band hand held radiometer which simulated three Thematic Mapper (TM) bands: TM3, TM4, and TM5. Daily spectral measurements of white oak leaves under three preservation treatments were made. The spectral readings over three treatments (fresh, bottled, and bagged vegetation) were indistinguishable in bands TM3 and TM5 for up to 4 days after collection. After that time bagged and bottled samples showed significant increases in reflected energy caused by loss of chlorophyll from and dehydration of the vegetation. No significant variation in the reflectance values from TM4 over preservation type for the experimental period was observed.

Labovitz, M. L.↗

Development of 2 underseat energy absorbers for application to crashworthy passenger seats for general aviation aircraft

This report presents the methodology and results of a program conducted to develop two underseat energy absorber (E/A) concepts for application to nonadjustable crashworthy passenger seats for general aviation aircraft. One concept utilizes an inflated air bag, and the other, a convoluted sheet metal bellows. Prototypes of both were designed, built, and tested. Both concepts demonstrated the necessary features of an energy absorber (load-limiter); however, the air bag concept is particularly encouraging because of its light weight. Several seat frame concepts also were investigated as a means of resisting longitudinal and lateral loads and of guiding the primary vertical stroke of the underseat energy absorber. Further development of a seat system design using the underseat energy absorbers is recommended because they provide greatly enhanced crash survivability as compared with existing general aviation aircraft seats.

Warrick, J. C.↗