Science on the Space Shuttle

On the Space Shuttle's third flight, scientific instruments will study the electromagnetic environment with charging and electron beams. Beam plasma discharge will be studied. The plasma diagnostics package contains electromagnetic and particle sensors to study the ionosphere. An attempt will be made to establish a more accurate base of solar UV irradiance measurements with an absolute error of 10 percent or less over the wavelength region 120-400 nm. The solar flare X-ray polarimeter will observe flare X-rays emitted between 5 and 30 keV and measure their polarization as a function of time and photon energy. A photopolarimeter will help study zodiacal light, and interplanetary dust will be sampled by a section of thick aluminum foil. Plant seedlings will be grown to research the effect of near-zero gravity on lignification. A thermal canister experiment will help determine whether instruments can be maintained at a fixed temperature under varying thermal loads.

Neupert, W. M.↗

Opportunities for Space Station wave experiments

The solar terrestrial observatory (STO) concept is discussed as well as Space Station accommodations for STO. Instruments for the initial STO which can be used to excite and detect waves include the electrodynamic tether, waves in space plasmas, space experiments with particle accelerators, vehicle charge and potential experiments, recoverable plasma diagnostics package, magnetospheric multiprobes, and theoretical and experimental beam plasma physics. An example is given of a typical campaign mode of operation which is appropriate for active experiments.

Shawhan, Stanley D.↗

Real-time sensing of optical alignment

The Large Deployable Reflector and other future segmented optical systems may require autonomous, real-time alignment of their optical surfaces. Researchers have developed gratings located directly on a mirror surface to provide interferometric sensing of the location and figure of the mirror. The grating diffracts a small portion of the incident beam to a diffractive focus where the designed diagnostics can be performed. Mirrors with diffraction gratings were fabricated in two separate ways. The formation of a holographic grating over the entire surface of a mirror, thereby forming a Zone Plate Mirror (ZPM) is described. Researchers have also used computer-generated hologram (CGH) patches for alignment and figure sensing of mirrors. When appropriately illuminated, a grid of patches spread over a mirror segment will yield a grid of point images at a wavefront sensor, with the relative location of the points providing information on the figure and location of the mirror. A particular advantage of using the CGH approach is that the holographic patches can be computed, fabricated, and replicated on a mirror segment in a mass production 1-g clean room environment.

Stier, Mark T.↗

Self-driven ion deflectometry measurements using MeV fusion-driven protons and accelerated deuterons in the deuterated hybrid x-pinch on the MAIZE LTD generator

Abstract We report on the results of point-projection ion deflectometry measurements from a mid-size university z-pinch experiment. A 1 MA 8 kJ LTD generator at the University of Michigan (called MAIZE) drove a hybrid x-pinch (HXP) with a deuterated polyethylene fiber load to produce a point-like source of MeV ions for backlighting. In these experiments, 2.7 MeV protons were generated by DD beam-target fusion reactions. Due to the kinematics of beam-target fusion, the proton energies were down-shifted from the more standard 3.02 MeV proton energy that is released from the center-of-mass rest frame of a DD reaction. In addition to the 2.7 MeV protons, strongly anisotropic beams of 3 MeV accelerated deuterons were detected by ion diagnostics placed at a radial distance of 90 mm from the x-pinch. Numerical reconstruction of experimental data generated by deflected hydrogen ion trajectories evaluated the total current in the vacuum load region. Numerical ion-tracking simulations show that accelerated deuteron beams exited the ion source region at large angles with respect to the pinch current direction.

Physics↗

Emittance Measurements with Wire Scanners in the Fermilab Side-Coupled Linac

The Fermilab Side-Coupled Linac accelerates H- beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster synchrotron ring. These wire scanners act as important diagnostic instru-ments to directly collect information on the beam s transverse distribution. The manipulation of the condi-tions of wire scanner data collection enables further characterization of the beamline, such as calculating emittance and the Twiss parameters of the beam at select regions. Here we present the results of these studies and characterization of the non-Gaussian transverse beam distribution observed.

43 PARTICLE ACCELERATORS↗

Diagnostic for Plasma Enhanced Chemical Vapor Deposition and Etch Systems

In order to meet NASA's requirements for the rapid development and validation of future generation electronic devices as well as associated materials and processes, enabling technologies ion the processing of semiconductor materials arising from understanding etch chemistries are being developed through a research collaboration between Stanford University and NASA-Ames Research Center, Although a great deal of laboratory-scale research has been performed on many of materials processing plasmas, little is known about the gas-phase and surface chemical reactions that are critical in many etch and deposition processes, and how these reactions are influenced by the variation in operating conditions. In addition, many plasma-based processes suffer from stability and reliability problems leading to a compromise in performance and a potentially increased cost for the semiconductor manufacturing industry. Such a lack of understanding has hindered the development of process models that can aid in the scaling and improvement of plasma etch and deposition systems. The research described involves the study of plasmas used in semiconductor processes. An inductively coupled plasma (ICP) source in place of the standard upper electrode assembly of the Gaseous Electronics Conference (GEC) radio-frequency (RF) Reference Cell is used to investigate the discharge characteristics and chemistries. This ICP source generates plasmas with higher electron densities (approximately 10(exp 12)/cu cm) and lower operating pressures (approximately 7 mTorr) than obtainable with the original parallel-plate version of the GEC Cell. This expanded operating regime is more relevant to new generations of industrial plasma systems being used by the microelectronics industry. The motivation for this study is to develop an understanding of the physical phenomena involved in plasma processing and to measure much needed fundamental parameters, such as gas-phase and surface reaction rates. species concentration, temperature, ion energy distribution, and electron number density. A wide variety of diagnostic techniques are under development through this consortium grant to measure these parameters. including molecular beam mass spectrometry (MBMS). Fourier transform infrared (FTIR) spectroscopy, broadband ultraviolet (UV) absorption spectroscopy, a compensated Langmuir probe. Additional diagnostics. Such as microwave interferometry and microwave absorption for measurements of plasma density and radical concentrations are also planned.

Cappelli, Mark A.↗

Space Experiments with Particle Accelerators (SEPAC)

The purpose of Space Experiments with Particle Accelerators (SEPAC) on the Atmospheric Laboratory for Applications and Science (ATLAS 1) mission, is to carry out active and interactive experiments on and in the earth's ionosphere, atmosphere, and magnetosphere. The instruments to be used are an electron beam accelerator (EBA), plasma contactor, and associated instruments the purpose of which is to perform diagnostic, monitoring, and general data taking functions. Four major classes of investigations are to be performed by SEPAC. They are: beam plasma physics, beam-atmosphere interactions, the use of modulated electron beams as transmitting antennas, and the use of electron beams for remote sensing of electric and magnetic fields. The first class consists mainly of onboard plasma physics experiments to measure the effects of phenomena in the vicinity of the shuttle. The last three are concerned with remote effects and are supported by other ATLAS 1 investigations as well as by ground-based observations.

Obayashi, Tatsuzo↗

Electromagnetic fields from pulsed electron beam experiments in space - Spacelab-2 results

During the Spacelab-2 mission a small satellite carrying various plasma diagnostic instruments was released from the Shuttle to coorbit at distances up to 300 m. During a magnetic conjunction of the Shuttle and the satellite an electron beam modulated at 1.22 kHz was emitted from the Shuttle during a 7 min period. The spatial structure of the electromagnetic fields generated by the beam was observed from the satellite out to a distance of 153 m perpendicular to the beam. The magnetic field amplitude of the strongest harmonics were comparable to the amplitude of simultaneously observed whistlers, while the electric field amplitudes were estimated to 1-10 mV/m.

Bush, R. I.↗

Atomic oxygen beam source for erosion simulation

A device for production of low-energy (5-10 eV) neutral atomic beams for surface modification studies, which recreates the flux of atomic oxygen in LEO, is described. The beam is produced by acceleration of plasma ions onto a negatively biased plate of high-Z metal; the ions are neutralized and reflected by the surface, retaining a large fraction of their incident kinetic energy, forming a beam of atoms. The device is based on a magnetically confined (3-4 kG) coaxial plasma source and the atom energy can be varied by adjusting the bias voltage. The source provides a neutral flux of roughly 5 x 10 to the 16th/sq cm/s at a distance of 10 cm and a fluence of roughly 10 to the 21st/sq cm in five hours. The source has been characterized with plasma diagnostics and by measuring the energy of an atomic argon beam using a mass spectrometer. Samples of carbon film, carbon-based paint, Kapton, Mylar, and Teflon exposed to atomic O beams show erosion quite similar to those observed in orbit on the Space Shuttle.

Cuthbertson, J. W.↗

Optical Diagnostics with Undulator Radiation for EIC Hadron Ring

Optical diagnostics is widely used for measurement of the electron beam parameters such as bunch length, beam size, and emittance. Using undulator radiation extends these measurements to the beam energy and energy spread. In this paper, we will study the applicability of synchrotron radiation for protons.

43 PARTICLE ACCELERATORS↗

DOE SCGSR Final Report - Project Accomplishments and Additional Materials

The major accomplishments of my project were successfully developing and testing the laser interferometry diagnostic on the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). This diagnostic helped advance my research by providing a simpler way to obtain electron density measurements of magnetized plasmas compared to other electron density diagnostics such as triple Langmuir probes. The laser used was a 561 nm continuous wave (CW) diode-pumped solid state (DPSS) laser. The PLX laser interferometry diagnostic consists of two parts. These include the launching and receiving sides of the laser diagnostic. The launching side consists of the main laser beam from the DPSS laser being split into five chords(probe beams) and a reference beam which are then directed with fiber optic couplers into fiber optic cables which transmit the probe beamsto the PLX vacuum chamber. The probe beams then pass through the plasma in the chamber and into the receiving side optics where they are again directed through fiber optic cables to be combined with the reference beam. The combined beams are transmitted via multi-mode fiber optic cables to photodiodes to convert the light signals into electrical signals. Before the electrical signals get digitized, they pass through bandpass and low pass filters to eliminate electromagnetic noise and unwanted frequencies. The electrical signals are then processed by IQ demodulators to determine phase angle difference between the probe and reference beams for each chord in order to calculate line-integrated electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space experiments with particle accelerators

Electron and plasma beams and neutral gas plumes were injected into the space environment by instruuments on Spacelab 1, and various diagnostic measurements including television camera observations were performed. The results yield information on vehicle charging and neutralization, beam-plasma interactions, and ionization enhancement by neutral beam injection.

Obayashi, T.↗

Feasibility of non-intrusive optical diagnostic measurements in hypersonic boundary layers for flight experiments

The present investigation of possible methods for nonintrusive optical diagnostics of hypersonic vehicle boundary layers notes electron-beam fluorescence to be capable of obtaining measurements of density, temperature, and shock-front location, as well as of N2, O2, and NO concentrations. NO will be a key indicator of vehicle nose and leading edge chemistry. It is expected that laser-induced fluorescence will allow measurements of NO and O2 concentrations when compact and reliable UV lasers become available; the sensors and instrumentation for spectral resolution of fluorescence along a line emanating from the vehicle and passing through the shock front already exist.

Cattolica, R. J.↗

A high repetition rate millimeter wavelength accelerator for an X-ray free-electron laser

A compact collinear wakefield accelerator has been designed for an X-ray free-electron laser capable of operating at a pulse repetition rate in the tens of kilohertz. The maximum achievable accelerating gradient has been determined, with its limitation linked to beam breakup instability. The fabrication techniques for the principal components of the accelerator including wakefield generation, couplers for excess power extraction and diagnostics, focusing quadrupoles, and a novel undulator have been discussed. Results from various laboratory and beam-based tests on these components have been compared to their original design specifications and demonstrated very good agreement. A preliminary design for the XFEL has been presented, featuring a novel small-period, force-neutral, adjustable-phase undulator.

26 undulator↗

Tandem-Mirror Ion Source

Improved ion source produces beam of ions at any kinetic energy from 1 to 1,000 eV, with little spread in energy or angle. Such ion beams useful in studies of surface properties of materials, surface etching, deposition, and development of plasma-diagnostic instrumentation. Tandemmirror ion source uses electrostatic and magnetic fields to keep electrons in ionization chamber and assure uniform output ion beam having low divergence in energy and angle.

Biddle, A.↗

Structured light approaches in laser-based plasma diagnostics

There is a growing demand for plasma diagnostics suitable for industrial plasma reactors employed in semiconductor nanofabrication, especially relevant to microelectronics and quantum information systems. Such reactors typically have limited optical access and pose considerable diagnostic challenges, including intense background emission, significant thermal loads, and contamination of optical viewports. In this study, we outline research into structured light techniques (laser beams with tailored spatial, temporal, or phase characteristics) that effectively overcome these issues using laser-induced fluorescence (LIF) as an example. The focus of presented diagnostics is on ion kinetics analysis within an industrial plasma source, although this approach is broadly applicable to other plasma systems and diagnostic contexts. We present a confocal LIF implementation using an axicon-generated Bessel annular beam, achieving spatial resolutions of approximately 5 mm at a focal distance of 300 mm, with potential improvements to about 1 mm. This approach matches conventional orthogonal LIF performance but requires only one optical port. Wavelength-modulation LIF employs nonlinear laser wavelength tuning to measure spectral line derivatives, suppressing background emission and enhancing details of spectral line shape. Additionally, we present new results on applying vortex beams (laser beams carrying orbital angular momentum, OAM) for LIF measurements in an industrial plasma device. These measurements enable simultaneous axial and tangential velocity determination using a single laser beam and have been tested with xenon ion transition. Initial quantification of results was performed. Together, these structured-light approaches provide robust, background-resilient, multi-dimensional diagnostics for complex plasma environments.

Romadanov, Ivan [Princeton Plasma Physics Laborato↗

ELF wave production by an electron beam emitting rocket system and its suppression on auroral field lines - Evidence for Alfven and drift waves

Orthogonal probes on a free-flying plasma diagnostics payload are used to study ELF electric disturbances in the auroral ionosphere that are due to the injection of powerful electron beams. Frequency spectrograms are presented for various pitch angles, pulsing characteristics, and other properties of the injected beams; the large scale DC ionospheric convection electric field is measured, together with auroral particle precipitation, visual auroral forms, and ionospheric parameters. In view of the experimental results obtained, it is postulated that the observed ELF waves are in the Alfven and drift modes, and are generated by the positive vehicle potential during beam injection.

Winckler, J. R.↗

$Z$-Pinch Interferometry Analysis With the Fourier-Based TNT Code

Here, we present the analysis of interferometry diagnostics with the user-friendly Talbot Numerical Tool (TNT), a Fourier-based postprocessing code that enables real-time assessment of plasma systems. TNT performance was explored with visible and infrared interferometry in pulsed-power-driven Z -pinch configurations to expand its capabilities beyond Talbot X-ray interferometry in the high-intensity laser environment. TNT enabled accurate electron density characterization of magnetically driven plasma flows and shocks through phase-retrieval methods that did not require data modification or masking. TNT demonstrated enhanced resolution, detecting below 4 % fringe shift, which corresponds to 8.7 × 10 15 cm –2 within 28 μ m, approaching the laser probing system limit. TNT was tested against a well-known interferometry analysis software, delivering an average resolving power nearly ten times better (~28 μ m versus ~ 210 μ m) when resolving plasma ablation features. TNT demonstrated higher sensitivity when probing sharp electron density gradients in supersonic shocks. A maximum electron areal density of 4.1 × 10 17 cm –2 was measured in the shocked plasma region, and a minimum electron density detection of ~ 1.0 × 10 15 cm –2 was achieved. When probing colliding plasma flows, the calculations of the effective adiabatic index and the associated errors were improved from γ* = 2.6 ± 1.6 – 1.4 ± 0.2 with TNT postprocessing, contributing valuable data for the interpretation of radiative transport. Additional applications of TNT in the characterization of pulsed-power plasmas and beyond are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗