Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biofouling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

194 records · Page 11

Moving Toward More Efficient Wastewater Recycling

Berkeley Lab researcher Emily Tow talks about her project to treat municipal wastewater in an energy efficient way and bring it up to drinking water standard. Using the Molecular Foundry, she is looking at biofouling of membranes used to treat wastewater.

LBNL, Berkeley Lab↗

Moving Toward More Efficient Wastewater Recycling

Berkeley Lab researcher Emily Tow talks about her project to treat municipal wastewater in an energy efficient way and bring it up to drinking water standard. Using the Molecular Foundry, she is looking at biofouling of membranes used to treat wastewater.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Zero-Valent Iron Permeable Reactive Barrier to Remediate Volatile Organic Compounds in Groundwater - 20209

The US DOE-SRS, the US EPA, and the South Carolina Department of Health and Environmental Control determined it was appropriate to perform a non-time critical removal action at the P-Area Groundwater Operable Unit at the SRS to reduce the mass and downgradient transport of trichloroethylene in the P-Area groundwater plume. Contaminated groundwater discharges to a nearby stream, Steel Creek, within the SRS boundaries, resulting in trichloroethylene concentrations above the maximum contaminant level. Impact to surface water is limited in areal extent and supported by recently collected characterization data. The P-Area Groundwater Operable Unit encompasses the groundwater beneath an industrial area within SRS, P Area, where the P-Reactor once operated. The boundaries of the P-Area Groundwater Operable Unit extend northwest to Steel Creek, northeast toward PAR Pond, and southeast to Meyers Branch. Groundwater in the Upper Three Runs Aquifer of the P-Area Groundwater Operable Unit has been impacted by reactor and facility operations between 1954 and 1991, including tritium and volatile organic compounds. The P-Area surface units contributing to groundwater contamination were remediated as part of the P-Area Operable Unit in 2011. The P-Reactor closure is one of the first of its kind in the DOE Complex and is one of only a few full-sized production reactors in the US to undergo completion of final closure activities. The nature and extent of groundwater contamination was determined using a variety of investigative approaches such as groundwater monitoring wells, direct-push technology, and surface water samples. Groundwater contamination associated with trichloroethylene is primarily exhibited in a narrow plume that extends from the source area at P-Reactor and west to Steel Creek. Maximum contaminant level exceedances in groundwater occur over an area of ∼6.9 hectares for trichloroethylene with concentrations as high as 7.7 milligrams per liter. To the west of the P-Area facility area, the trichloroethylene groundwater plume is controlled by a buried geologic feature, assumed to be an old stream bed, that further narrows the groundwater plume in what has been designated as the 'neck area.' This narrowing of the groundwater plume provides an ideal location for a treatment barrier. The non-time critical removal action alternative chosen is to install a zero-valent iron permeable reactive barrier within the neck area of the trichloroethylene groundwater plume, perpendicular to groundwater flow direction. This technology will provide a treatment barrier that will reduce trichloroethylene groundwater concentrations by 90% and has an anticipated useful life of at least 25 years. A pre-design investigation was performed in the neck area to confirm site lithology, hydrogeology, geochemistry, and extent of trichloroethylene contamination prior to a final design. A treatability study, conducted as part of the pre-design investigation, indicated that the subsurface and groundwater in the PArea Groundwater Operable Unit is compatible with the zero-valent iron and will not lead to excessive buildup from mineralization/precipitation or biofouling. Probabilistic modeling was conducted using field and laboratory data to determine the expected performance of the zero-valent iron permeable reactive barrier. The model simulations indicated that a 3.81-centimeter thick barrier would provide greater than 90% reduction of trichloroethylene groundwater concentration. The final design of the zero-valent iron permeable reactive barrier is a barrier that will extend 80.5 linear meters in a 'zigzag' orientation to best transect the trichloroethylene plume and account for varying groundwater flow. The barrier will be installed from 13.7 meters below ground surface to 41.1 meters below ground surface for 65.8 linear meters and from 13.7 meters below ground surface to 36.6 meters below ground surface for 14.6 linear meters, the base of which is 'keyed' into a low permeability zone. The barrier is designed to a thickness of 10.2 centimeters, which was determined to reduce the trichloroethylene groundwater concentrations by greater than 90% with a safety factor of 2.67. A total of approximately 689 metric tons of zero-valent iron will be injected through 22 injection wells spaced 3.66 meters apart, using guar to suspend the zero-valent iron. Zero-valent iron permeable reactive barrier construction will be monitored through 23 installed resistivity receivers offset 7.32 meters from the zerovalent iron permeable reactive barrier. The zero-valent iron will be energized with a low-voltage 100 Hertz signal during injection and will be monitored using the resistivity receivers to ensure complete coalescence of the zero-valent iron permeable reactive barrier. The zero-valent iron was sized to have a hydraulic conductivity greater than the natural subsurface, thus promoting groundwater flow through the barrier. As contaminated groundwater contacts the zero-valent iron, volatile organic compounds, including trichloroethylene, are immediately degraded to harmless compounds such as ethylene. The performance of the zero-valent iron permeable reactive barrier will be monitored using three upgradient monitoring well clusters, six downgradient monitoring well clusters, and four in-wall monitoring wells. The in-wall monitoring wells will indicate immediate reduction of trichloroethylene mass in the groundwater and allow analyses of the zero-valent iron permeable reactive barrier health. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of NAA to Detect Uptake of Uranium and other Elements in Adsorbents

A consortium of national lab and university partners, led by Oak Ridge (ORNL) and Pacific Northwest (PNNL) National Laboratories, has been working on the development of fibers with the ability to passively adsorb uranium out of seawater. In experiments by PNNL, the adsorption capacity of these fibers was observed to decrease by up to 30% as an effect of marine biofouling. In order to increase the cost-effectiveness of the process, the project ultimately aims to mitigate the effect of fouling by adding antimicrobial agents such as Ag nanoparticles to the adsorbents. To work towards this goal, a method of producing fiber surrogates for the specialized uranium adsorbents was established. This enabled researcher to complete fouling trials at a faster rate and lower cost. Additionally, the project has proven Neutron Activation Analysis (NAA) to be a viable process for measuring the uptake in fibers. The technique stands out because of its ability to measure low concentrations of uranium and other elements with high sensitivity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Aluminum phosphate coatings

Aluminophosphate compounds and compositions as can be used for substrate or composite films and coating to provide or enhance, without limitation, planarization, anti-biofouling and/or anti-microbial properties.

Sambasivan, Sankar↗

In situ non-destructive measurement of biofilm thickness and topology in an interferometric optical microscope

Biofilms are ubiquitous and deleteriously impact a wide range of industrial processes, medical and dental health issues, and environmental problems such as transport of invasive species and the fuel efficiency of ocean going vessels. Biofilms are difficult to characterize when fully hydrated, especially in a non-destructive manner, because of their soft structure and water-like bulk properties. Herein we describe a non-destructive high resolution method of measuring and monitoring the thickness and topology of live biofilms of using white light interferometric optical microscopy. Using this technique, surface morphology, surface roughness, and biofilm thickness can be measured non-destructively and with high resolution as a function of time without disruption of the biofilm activity and processes. The thickness and surface topology of a P. putida biofilm were monitored growing from initial colonization to a mature biofilm. Typical bacterial growth curves were observed. Increase in surface roughness was a leading indicator of biofilm growth.

biofilm↗

Superhydrophobic materials and coatings: a review

Over the past few years, the scientific community, as well as the world's coatings industry has seen the introduction of oxide/polymer-based superhydrophobic surfaces and coatings with exceptional water repellency. We have captured the public's imagination, in online videos, by showing people walking through mud puddles without getting their tennis shoes wet or muddy, and water literally flying off coated surfaces. Our article attempts to explain the basics of this behavior and to discuss and explain the latest superhydrophobic technological breakthroughs. Since superhydrophobic surfaces and coatings can fundamentally change how water interacts with surfaces, and the fact that earth is a water world, it can legitimately be said that this technology has the potential to literally change the world.

36 MATERIALS SCIENCE↗

Evaluation of Soiling and Potential Mitigation Approaches on Photovoltaic Glass

The natural soiling of photovoltaic cover glass has recently been shown to include both an inorganic and organic particulate matter. Under favorable growth conditions, the latter can lead to the growth of dense colonies of filamentous fungi, which potentially leads to measurable performance losses over time. Herein, we report on a field study where glass coupon samples were deployed in soiling-prone locations, which focused on Dubai (United Arab Emirates) and Mumbai (India). For each site location, clear differences in the soiling were observed. The samples from Mumbai were contaminated with an abundance of filamentous fungi, whereas the samples from Dubai had primarily inorganic contamination. As a result, the effectiveness of soiling mitigation strategies, which include cleaning techniques and glass coatings, are discussed in detail.

14 SOLAR ENERGY↗

Optical Microscopy Study of Soiling on Photovoltaic Glass: Evaluation of Mitigation Strategies

The natural soiling of photovoltaic cover glass has recently been shown to include both inorganic and organic particulate matter. Under favorable growth conditions, the latter can lead to the growth of dense colonies of filamentous fungi, potentially leading to measurable performance losses over time. Herein, we report on a field study where glass coupon samples were deployed in soiling-prone locations, focusing on Dubai (United Arab Emirates) and Mumbai (India). For each site location, clear differences in the soiling were observed. The samples from Mumbai were contaminated with an abundance of filamentous fungi whereas the samples from Dubai had primarily inorganic contamination. The effectiveness of soiling mitigation strategies, including cleaning techniques and glass coatings, are discussed in detail.

14 SOLAR ENERGY↗

Performance of three hydrophone flow shields in a tidal channel

Pseudosound caused by turbulent pressure fluctuations in fluid flow past a hydrophone, referred to as flow noise, can mask propagating sounds of interest. Flow shields can mitigate flow noise by reducing non-acoustic pressure fluctuations sensed by a hydrophone. We evaluate the performance of three hydrophone flow shields (two nylon fabrics and an oil-filled enclosure) in a tidal channel with peak current speed of 1.3 m s−1. All three flow shields reduced flow noise without attenuating propagating sound below 20 kHz. The oil-filled enclosure performed best, reducing flow noise by over 30 dB at frequencies below 40 Hz.

47 OTHER INSTRUMENTATION↗

ASU’s DAC polymer-enhanced cyanobacterial bioproductivity (AUDACity)

ASU’s DAC polymer-enhanced cyanobacterial bioproductivity (AUDACity) project aims to demonstrate a novel, scalable method for removing carbon dioxide (CO 2 ) directly from ambient air and delivering it to cyanobacterial cultures to produce commodity biofuel, mid-value protein for supplements, and high value phycocyanin (PC), a natural blue colorant (Figure A). This approach uses low-cost, reusable anion exchange polymers embedded in modular mesh packets, which capture CO 2 during drying cycles when exposed to ambient air, and release concentrated CO 2 into aqueous cultivation systems. The project addresses a critical challenge in energy research needed for developing sustainable, economically viable methods of Direct Air Capture (DAC) that can be integrated with bio-based systems for fuel and chemical production. AUDACity contributes to scientific understanding by integrating materials chemistry, cyanobacterial biology, and system engineering to create a distributed CO 2 delivery platform. Key insights have emerged around the design of biocompatible sorbents, optimization of CO 2 capture-release cycles, and durability of packet-based delivery systems under outdoor conditions. Notably, the team has synthesized and tested a range of polymer sorbents, identified mechanisms of material degradation and fouling, and advanced both lab- and pilot-scale cultivation systems to evaluate performance. From a technical and economic standpoint, AUDACity shows promise for achieving cost-effective CO 2 capture and delivery into aqueous media and biofuel production. Preliminary techno-economic analysis (TEA) indicates that the DAC system based on current performance can reach $\$$680/tonne CO 2 delivered into aqueous solution; with reasonable improvements to sorbent lifetime, sorbent capacity, reducing water uptake the approach could reach $\$$66/tonne by avoiding the need for energy-intensive sorbent regeneration and CO 2 compression, making it more feasible for decentralized deployment. With these costs for CO 2 and by extracting and selling high-value PC ($\$$50/kg) and mid-value protein supplement ($\$$6/kg), the remaining biomass can be hydrothermally treated into biofuel for $\$$2.50/gallon, and would support a small first-of-a-kind biorefinery capable of producing 500 barrels per day of biofuel. The project offers meaningful public benefits by advancing carbon removal technologies that are low-energy, modular, and adaptable to non-arable land and brackish water use. It aligns with national goals to develop advanced biotechnology and supports future pathways for bio-based fuels and products. By enabling direct coupling of CO 2 transfer into aqueous medium and biological carbon utilization, AUDACity lays the groundwork for effective algae cultivation without wasteful CO 2 delivery and is a promising and innovative solution for low-carbon fuel and bioproduct generation contributing to a vigorous bioeconomy.

09 BIOMASS FUELS↗