Search NASA⌕ Search

SEARCH · Search NASA

Results for “Board”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Liquid hydrogen storage system for heavy duty trucks: Configuration, performance, cost, and safety

In this work, we investigate the potential of liquid hydrogen storage (LH 2 ) on-board Class-8 heavy duty trucks to resolve many of the range, weight, volume, refueling time and cost issues associated with 350 or 700-bar compressed H 2 storage in Type-3 or Type-4 composite tanks. We present and discuss conceptual storage system configurations capable of supplying H 2 to fuel cells at 5-bar with or without on-board LH 2 pumps. Structural aspects of storing LH 2 in double walled, vacuum insulated, and low-pressure Type-1 tanks are investigated. Structural materials and insulation methods are discussed for service at cryogenic temperatures and mitigation of heat leak to prevent LH 2 boiloff. Failure modes of the liner and shell are identified and analyzed using the regulatory codes and detailed finite element (FE) methods. The conceptual systems are subjected to a Failure modes and effects analysis (FMEA) and a safety, codes, and standards (SCS) review to rank failures and identify safety gaps. The results indicate that the conceptual systems can reach 19.6% usable gravimetric capacity, 40.9 g-H 2 /L usable volumetric capacity and $174-183/kg-H 2 cost (2016 USD) when manufactured 100,000 systems annually.

08 HYDROGEN↗

Cradle-to-gate life cycle assessment of advanced composite panels incorporating CO 2 -derived multi-walled carbon nanotubes and hemp fiber for sustainable building applications

Advanced composite panels represent a promising pathway to reducing carbon emissions in the construction industry, yet comprehensive environmental impact assessments remain limited. Here, in this study, we conduct a life cycle assessment (LCA) to evaluate the environmental impacts of innovative composite panels produced from multi-walled carbon nanotubes (MWCNTs), hemp fiber (HF), recycled carbon fiber (rCF), and recycled polypropylene (PP), exploring their potential as baseline structural equivalents to conventional gypsum board. MWCNTs and HF play a critical role in sequestering carbon during raw material production, while the recycling processes for CF and PP generally require less energy compared to virgin material production. The LCA evaluates environmental performance using the TRACI 2.1 method, covering global warming potential (GWP), ozone depletion, smog formation, acidification, eutrophication, carcinogenic and non-carcinogenic effects, respiratory impacts, ecotoxicity, and fossil fuel depletion. Compositional variations—resin type (virgin vs. recycled), rCF content (9–29 wt%), and HF content (10–30 wt%)—are introduced for sensitivity and hotspot analyses. Results demonstrate that, when compared on the basis of preliminary structural equivalence, increasing recycled PP, rCF, and HF content can significantly reduce global warming potential compared to gypsum board. Beyond carbon reduction, the composite panels show trade-offs across other environmental categories. With the growing demand for composite materials in interior panels, ceiling systems, and exterior claddings, these findings highlight the environmental benefits and potential trade-offs of the proposed composites, establishing a foundational framework to support their continued development toward full building-system integration.

Advanced composite manufacturing↗

Differences in the response of two light guide technologies and two readout technologies after an exchange of liquid argon in the dewar

In this investigation the response to the scintillation light generated by through-going cosmic muons in liquid argon (LAr) was measured by two light guide technologies and two readout technologies after five weeks of running in the TallBo dewar at Fermilab. The response was remeasured after the dewar was drained of LAr, refilled, and then run again for an additional four weeks. After the dewar was refilled, there was clear evidence that the scintillation signal had dropped significantly. The two light guide technologies were developed at Indiana University and MIT/Fermilab. The two readout technologies were boards that passively or actively ganged 12 Hamamatsu MPPCs. Two possible explanations were identified for the degraded signal: the response of the two light guide technologies degraded due to damage caused by thermal cycling, and/or unknown differences in the trace residual Xe contamination in the fills of LAr led to the observed drop in scintillation light. Neither absorption nor quenching by N 2 , O 2 , and H 2 O contamination can account for the degradation. Neither the individual Hamamatsu MPPCs nor the passive/active ganging boards appear to have been affected by the thermal cycling. The path length distributions of the cosmics traversing the dewar appear quite similar in both event samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplicity trigger detector for the S π RIT experiment

A multiplicity trigger detector (MTD) was developed for the SπRIT experiment that aims to probe the high- density symmetry energy via heavy-ion collisions (HICs). The MTD is designed to measure the charged-particle multiplicity in HICs to provide a trigger signal that can be used to select high-multiplicity events induced by central collisions. The MTD consists of two side-walls segmented into 30 plastic scintillation paddles, each equipped with a multi-pixel photon counter. A custom board with EASIROC front-end ASIC is used as readout electronics. A multiplicity logic signal is generated by an on-board FPGA that processes the discriminated signals from EASIROCs. The overall latency of the whole detector system for outputting the trigger is less than 100 ns, including 52 ns of electronics latency for processing the signals. During the measurement of 112 Sn + 124 Sn reactions at an incident energy of 270 MeV/nucleon, the minimum multiplicity threshold of the MTD was set to 4, where the overall trigger efficiency was obtained to be about 39 % for inclusive nuclear reactions. Furthermore, a simulation study with a numerical calculation of HICs found that the central collisions of impact parameters of less than 4 fm can be triggered with a high efficiency of more than 95 % by the experimental trigger condition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal

Here we are reporting on a new readout circuit developed for the lead tungstate (PbWO4) scintillation detectors for the Electron Ion Collider (EIC) Electron Endcap Electromagnetic Calorimeter EEEMCal. The high magnetic field region precludes the use of photomultiplier tubes while the detector requirements specify good spectral resolution performance and fast pulse integration over a large dynamic range. We selected a silicon photomultiplier (SiPM) from Hamamatsu and produced a matrix of 4 x 4 sensors to cover the 20 mm x 20 mm scintillator coupling surface. Signal acquisition and amplification electronics boards were designed and integrated with the sensor board to produce a compact high performance readout package. A prototype detector was built and tested at Jefferson Lab with encouraging resolution and timing performance results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single channel PICOSEC Micromegas detector with improved time resolution

This paper presents design guidelines and the experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving the stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of the detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitic capacitance and inductance on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. Detectors were initially tested in the laboratory. Finally, the timing performance of the detectors with different pad sizes was verified using 150 GeV muons. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5 ± 0.8 ps was achieved for a detector with 10 mm diameter readout pad size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The STAR Forward Silicon Tracker

The Forward Silicon Tracker (FST) is a pivotal component of the forward upgrade of the Solenoidal Tracker at RHIC (STAR), designed to discern hadron charge signs with a momentum resolution better than 30% for 0.2 < p T < 2GeV/c in the 2.5 < η < 4 pseudorapidity range. Its compact design features three disks along the beam direction, minimized material budget, and scattering effects. The FST uses Hamamatsu’s p-in-n silicon strip sensors with a double metal layer that enables efficient signal routing to the readout electronics, enhancing overall detector performance. The flexible hybrid boards, essential for the readout system, are constructed with Kapton and copper layers to optimize signal handling and power distribution. These boards connect silicon strips to analogue pipeline ASIC APV25-S1 chips, which read up to 128 channels each. A cooling system with nonconducting, volatile NOVEC 7200 coolant at 22.2 °C mitigates ASIC-generated heat. Furthermore, the FST enhances forward tracking performance at STAR as an integral part of the forward upgrade.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Identifying mitigation strategies for $\mathrm{COVID}$-$\mathrm{19}$ superspreading on flights using models that account for passenger movement

Despite commercial airlines mandating masks, there have been multiple documented events of COVID-19 superspreading on flights. Conventional models do not adequately explain superspreading patterns on flights, with infection spread wider than expected from proximity based on passenger seating. An important reason for this is that models typically do not consider the movement of passengers during the flight, boarding, or deplaning. Understanding the risks for each of these aspects could provide insight into effective mitigation measures. We modeled infection risk from seating and fine-grained movement patterns – boarding, deplaning, and inflight movement. We estimated infection model parameters from a prior superspreading event. We validated the model and the impact of interventions using available data from three flights, including cabin layout and seat locations of infected and uninfected passengers, to suggest interventions to mitigate COVID-19 superspreading events during air travel. Specifically, we studied: 1) London to Hanoi with 201 passengers, including 13 secondary infections among passengers; 2) Singapore to Hangzhou with 321 passengers, including 12 to 14 secondary infections; 3) a non-superspreading event on a private jet in Japan with 9 passengers and no secondary infections. Here our results show that the inclusion of passenger movement better explains the infection spread patterns than conventional models do. We also found that FFP2/N95 mask usage would have reduced infection by 95–100%, while cloth masks would have reduced it by only 40–80%. Results indicate that leaving the middle seat vacant is effective in reducing infection, and the effectiveness increases when combined with good quality masks. However, with a good mask, the risk is quite low even without the middle seats being empty. Our results suggest the need for more stringent guidelines to reduce aviation-related superspreading events of COVID-19.

54 ENVIRONMENTAL SCIENCES↗

A Miniature Multilevel Structures for Lossless Ion Manipulations Ion Mobility Spectrometer with Wide Mobility Range Separation Capabilities

Here, ion mobility spectrometry employing structures for lossless ion manipulations (SLIM-IMS) is an attractive gas-phase separation technique due to its ability to achieve unprecedented effective ion path lengths (>1 km) and IMS resolving powers in a small footprint. The emergence of multilevel SLIM technology, where ions are transferred between vertically stacked SLIM electrode surfaces, has subsequently allowed for ultralong single pass path lengths (>40 m) to be achieved, enabling ultrahigh resolution IMS measurements to be performed over the entire mobility range in a single experiment. The implementation of multiple SLIM levels requires very little additional space for the SLIM system, and we developed a miniature SLIM module (miniSLIM) based on multilevel SLIM technology and report the performance here. The module is 11.1 cm x 6.7 cm x 1.4 cm (L x W x H) and consists of three SLIM levels totaling 1-meter path length. Ion trajectory simulations were used to optimize the SLIM board spacings and SLIM board thicknesses of the miniSLIM IMS system. Methods of efficiently transferring ions between SLIM levels were examined and a new approach using asymmetric traveling waves (TWs) was developed and implemented in the miniSLIM. We experimentally characterized the performance of the --meter multilevel miniSLIM IMS-MS relative to a drift tube IM--MS using an Agilent tuning mixture and tetraalkylammonium cations. The 1-meter miniSLIM achieved a resolving power of up to 131 (CCS/ΔCCS), ~1.5x higher than achievable with a 78 cm path length drift tube IMS, and successfully transmitted the entire ion mobility range in a single separation. We also demonstrated the miniSLIM’s performance as a standalone IMS system (i.e., without MS), showing baseline separation between Agilent tuning mixture cations with the full mobility range observed, and a standard peptide mixture with different charge states readily differentiated. Overall the miniSLIM provides a compact alternative to high performance IMS instruments possessing similar path lengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cyclable Variable Path Length Multilevel Structures for Lossless Ion Manipulations (SLIM) Platform for Enhanced Ion Mobility Separations

Ion mobility-mass spectrometry (IMS-MS) is increasingly used to analyze complex samples and provide structural information of unknown compounds. As the complexity of samples increases, there is a need to improve the resolution of IMS-MS instruments to increase the rate of molecular identification. In this work, we evaluated a cyclable and variable-pathlength multilevel Structures for Lossless Ion Manipulations (SLIM) platform to achieve a higher resolving power than previously possible. This new multilevel SLIM platform has eight separation levels connected by ion escalators and a path length of ~88 meters (~11 meters per level). Our new multilevel SLIM can also be operated in an ‘ion cycling’ mode where a set of return ion escalators transport ions from the eighth back to the first level, allowing even longer path lengths (and higher IMS resolution). The platform has been improved to enhance the ion transmission and IMS separation quality by reducing the spacing between SLIM boards as well as board thickness, reducing the ions’ escalator residence time. Compared to the previous generation, the new multilevel SLIM demonstrated a better transmission for a set of phosphazene ions, especially for the low-mobility ions. The new multilevel SLIM achieved better resolving powers than our previous 4-level SLIM. The collision cross-section-based resolving power of the SLIM platform was tested using a pair of singly-charged reverse sequence peptides (SDGRG 1+ , GRGDS 1+ ). We achieved 1100 resolving power using 88 meters of path length (i.e., 8 levels) and 1400 following an additional pass through the eight levels (i.e., 16 levels or 173.5 m). The multilevel SLIM was further evaluated to demonstrate the enhanced separation for a positively and negatively charged brain total lipid extract sample. Finally, the new multilevel SLIM enables much higher resolving powers for a wide range of ion mobilities, improved transmission for low-mobility ions, and the ability to perform even higher resolving power for ions of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion Mobility Separations Using Cocentric Architecture

Ion mobility separations are usually performed in linear channels, which, when extended, can have a large footprint. In this work, we explored the performance of an ion mobility device with a curved architecture which can have a more compact form. The Co-centric Ion Mobility Spectrometer (CIMS) works by manipulating ions between two co-centric surfaces, each containing a serpentine track. The mobility separation inside CIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside CIMS, they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path in structures for lossless ion manipulations (SLIM). We then performed experimental validation of CIMS in conjunction with a TOF MS. The CIMS was made of 2 flexible printed circuit board materials folded into concentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter × 152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and 8 peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). For tetraalkylammonium ions, the average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW). For the peptide mixture ions, the resolving power was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TW CCS for the peptide mixture ions ranged was about 0.4%. In conclusion, the new device showed promising results for a device made of a flexible printed circuit board material, but improvements are needed to further increase the resolving power.

59 BASIC BIOLOGICAL SCIENCES↗

Calibration and Initial Results of Space Radiation Dosimetry Using the iMESA-R

The integrated Miniaturized Electrostatic Analyzer-Reflight (iMESA-R) is a space weather instrument designed to measure plasma density, temperature, and spacecraft charging, along with total ionizing dose and dose rate. A constellation consisting of five nearly identical instruments has been designed and developed to act as science payloads hosted on-board Department of Defense satellites operating in low-Earth orbit. To validate the dosimetry component of the iMESA-R, a radiation test study was performed to calibrate the dosimeter and ascertain the attenuation due to the instrument aluminum housing. An 80 curie Cobalt-60 radioisotope source emitting beta, X-ray, and gamma ray radiation decay products was used to calibrate the dosimeter response as a function of distance and instrument shielding. We present results of the calibration study along with initial on-orbit data presented from the first operational iMESA-R hosted on-board Space Test Program Satellite 5 in a polar Earth orbit. The initial on-orbit data demonstrate the ability to map the radiation environment, particularly the South Atlantic Anomaly and the auroral regions using total ionizing dose rate due to electrons of E > 1.5 MeV and protons of E > 25 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Emergent microrobotic oscillators via asymmetry-induced order

Abstract Spontaneous oscillations on the order of several hertz are the drivers of many crucial processes in nature. From bacterial swimming to mammal gaits, converting static energy inputs into slowly oscillating power is key to the autonomy of organisms across scales. However, the fabrication of slow micrometre-scale oscillators remains a major roadblock towards fully-autonomous microrobots. Here, we study a low-frequency oscillator that emerges from a collective of active microparticles at the air-liquid interface of a hydrogen peroxide drop. Their interactions transduce ambient chemical energy into periodic mechanical motion and on-board electrical currents. Surprisingly, these oscillations persist at larger ensemble sizes only when a particle with modified reactivity is added to intentionally break permutation symmetry. We explain such emergent order through the discovery of a thermodynamic mechanism for asymmetry-induced order. The on-board power harvested from the stabilised oscillations enables the use of electronic components, which we demonstrate by cyclically and synchronously driving a microrobotic arm. This work highlights a new strategy for achieving low-frequency oscillations at the microscale, paving the way for future microrobotic autonomy.

42 ENGINEERING↗

Travelling wave‐based fault detection and location in a real low‐voltage DC microgrid

Abstract This paper discusses a device‐level implementation of a travelling wave (TW) protection device (PD) designed for a real low‐voltage DC microgrid. The TWPD fault detection and location algorithm is executed on a commercial digital signal processor (DSP) board, involving signal sampling at 1 MHz via the DSP board's analog‐to‐digital converter (ADC). The analogue input card measures positive pole, negative pole and pole‐to‐pole voltages at the TWPD location. Upon a successful fault detection using a second‐order high‐pass filter, the voltage data is normalised and multi‐resolution analysis (MRA) is performed on a 128‐sample buffer around the TW arrival time. MRA employs the discrete wavelet transform (DWT) to capture high‐frequency voltage patterns, and then the Parseval's energy theorem quantifies these TW characteristics by computing the energy of reconstructed wavelet coefficients. These energy values per decomposed frequency band are the basis for training a random forest classifier that predicts fault location and type. The TWPD is fully implemented and connected to a real DC microgrid in Albuquerque, NM, USA, for validation, and results are shown for field tests verifying the performance under faults.

Paruthiyil, Sajay Krishnan [Department of Electric↗

The brighter-fatter effect in the JWST MIRI Si:As IBC detectors: I. Observations, impact on science, and modeling

Context.The Mid-Infrared Instrument (MIRI) on board theJames WebbSpace Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims.We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods.We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the publicPoisson_CCDcode. Results.We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of charge-coupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10–25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.

Astronomy & Astrophysics↗

Delving into the depths of NGC 3783 with XRISM II. Cross-calibration of X-ray instruments used in the large, multi-mission observational campaign

Context. Accurate X-ray spectroscopic measurements are fundamental for deriving basic physical parameters of the most abundant baryon components in the Universe. The plethora of X-ray observatories currently operational enables a panchromatic view of the high-energy emission of celestial sources. However, uncertainties in the energy-dependent calibration of the instrument transfer functions (e.g. the effective area, energy redistribution, or gain) can limit - and historically, did limit - the accuracy of X-ray spectroscopic measurements. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign.

Active Galactic Nuclei, individual: NGC 3783↗

Second Generation Readout For Large Format Photon Counting Microwave Kinetic Inductance Detectors

We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-infrared wavelength bands. Our system retains much of the core signal processing architecture from the first generation system but with a significantly higher bandwidth, enabling the readout of kilopixel MKID arrays. Each set of readout boards is capable of reading out 1024 MKID pixels multiplexed over 2 GHz of bandwidth; two such units can be placed in parallel to read out a full 2048 pixel microwave feedline over a 4 GHz–8 GHz band. As in the first generation readout, our system is capable of identifying, analyzing, and recording photon detection events in real time with a time resolution of order a few microseconds. Here, we describe the hardware and firmware, and present an analysis of the noise properties of the system. We also present a novel algorithm for efficiently suppressing IQ mixer sidebands to below −30 dBc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors

We introduce a Xilinx RF System-on-Chip (RFSoC)-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short), which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC field-programmable gate array, custom firmware, and software and an optional companion custom-designed analog front-end board. We characterize the analog performance of the system as well as its digital latency, important for quantum error correction and feedback protocols. We benchmark the controller by performing standard characterizations of a transmon qubit. We achieve an average gate fidelity of ℱ avg =99.93%. All of the schematics, firmware, and software are open-source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗