Search NASA⌕ Search

SEARCH · Search NASA

Results for “Builders Challenge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The Readout Electronics of the Mu2e Electromagnetic Calorimeter

The Mu2e electromagnetic calorimeter has been designed to measure ~100 MeV electrons with energy resolution σE/E <10%, time resolution σt < 500ps and position resolution σx < 1cm. The detector is composed of 1348 un-doped CsI crystals coupled to two large area Silicon Photomultipliers (SiPMs). Each SiPM is connected to a Front End Electronics (FEE) chip which hosts the shaping amplifier and the high voltage linear regulator. A group of 20 FEE is controlled by one Mezzanine Board (MB) which transmits the amplified signals to one Digitizer ReAdout Controller board (DiRAC). The DiRAC samples the waveforms at 200 MHz with 12-bit ADCs, packs the data according to the Mu2e custom format and transmits them to the event builder through an optical transceiver. To limit the number of pass-through connectors and the length of the cables, the readout and digitization electronics is located inside the detector cryostat and close to the interaction target. The boards will have to sustain a neutron fluence of about 5x10 10 n/cm 2 @ 1 MeVeq (Si)/y and a Total Ionizing Dose of about 12 krad, while working into a 1T magnetic field and a vacuum of 10 (-4) Torr. This harsh operational environment has made the electronics design challenging and required an extended campaign of tests to select and qualify the employed electronic components. In this paper we report on the board architecture and design, on the qualification of the prototypes, as well as on the results of the first vertical slice test of the Mu2e calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Developing Flexible Discrete Event Simulation Models in an Uncertain Policy Environment

On February 1st, 2010 U.S. President Barack Obama submitted to Congress his proposed budget request for Fiscal Year 2011. This budget included significant changes to the National Aeronautics and Space Administration (NASA), including the proposed cancellation of the Constellation Program. This change proved to be controversial and Congressional approval of the program's official cancellation would take many months to complete. During this same period an end-to-end discrete event simulation (DES) model of Constellation operations was being built through the joint efforts of Productivity Apex Inc. (PAl) and Science Applications International Corporation (SAIC) teams under the guidance of NASA. The uncertainty in regards to the Constellation program presented a major challenge to the DES team, as to: continue the development of this program-of-record simulation, while at the same time remain prepared for possible changes to the program. This required the team to rethink how it would develop it's model and make it flexible enough to support possible future vehicles while at the same time be specific enough to support the program-of-record. This challenge was compounded by the fact that this model was being developed through the traditional DES process-orientation which lacked the flexibility of object-oriented approaches. The team met this challenge through significant pre-planning that led to the "modularization" of the model's structure by identifying what was generic, finding natural logic break points, and the standardization of interlogic numbering system. The outcome of this work resulted in a model that not only was ready to be easily modified to support any future rocket programs, but also a model that was extremely structured and organized in a way that facilitated rapid verification. This paper discusses in detail the process the team followed to build this model and the many advantages this method provides builders of traditional process-oriented discrete event simulations.

Miranda, David J.↗

A Multi-State Model for Catalyzing the National Home Energy Retrofit Market (Final Technical Report)

In the fall of 2010, the Alabama Department of Economic and Community Affairs (ADECA) launched the Multi-State Model for Catalyzing the National Home Energy Retrofit Market Project (Multi-State Project). This residential energy efficiency pilot program was a collaborative effort among the states of Alabama, Massachusetts, Virginia, and Washington, and was funded by competitive State Energy Program (SEP) awards through the U.S. Department of Energy (DOE). The objective of this project was to catalyze the home energy efficiency retrofit market in select areas within the state of Alabama. To achieve this goal, the project addressed a variety of marketplace elements that did not exist, or were underdeveloped, at the outset of the effort. These included establishing minimum standards and credentials for marketplace suppliers, educating and engaging homeowners on the benefits of energy efficiency and addressing real or perceived financial barriers to investments in whole-home energy efficiency, among others. The anticipated effect of the activities would be increased market demand for retrofits, improved audit to retrofit conversion rates and growth in overall community understanding of energy efficiency. The four-state collaborative was created with the intent of accelerating market transformation by allowing each state to learn from their peers, each of whom possessed different starting points, resources, and strategies for achieving the overall objective. The four partner states engaged the National Association of State Energy Officials (NASEO) to oversee a project steering committee and to manage the project evaluation for all four states. The steering committee, comprised of key program partners, met on a regular basis to provide overall project coordination, guidance, and progress assessment. While there were variances in program design among the states, there were several common elements: use of the Energy Performance Score (EPS) platform; an audit and home energy rating tool; emphasis on community based coordination and partnerships; marketing and outreach to increase homeowner participation; training for market actors; access to financing options including rebates, incentives, and loan products; and an in depth process evaluation to support continual program improvement and analysis. In Alabama, Nexus Energy Center operated energy efficiency retrofit programs in Huntsville and Birmingham. In the Huntsville community the AlabamaWISE program was available in five Alabama counties: Cullman, Lawrence, Limestone, Madison, and Morgan. In Birmingham, the program was available to residents in Jefferson and Shelby Counties. In both communities, the program was similar in terms of program design but tailored marketing and partnerships to address the unique local conditions and population of each community. ADECA and the Southeast Energy Efficiency Alliance (SEEA) provided overall project management services and common resources to the local program administrator Nexus Energy Center, including contracted services for contractor training, quality assurance testing, data collection and reporting, and compliance. The fundamental components of the AlabamaWISE program included a vertical contractor-based business model; comprehensive energy assessments; third-party quality assurance; rebates for installation of energy saving measures; accessible, low-interest financing; targeted and inbound marketing; Energy Performance Score (EPS) tool to engage and educate homeowners; training for auditors, contractors, and real estate professionals; and online resources for education and program enrollment. Program participants were eligible to receive rebates or financing toward the assessments and upgrades to their home provided they reached at least 20 percent deemed or modeled energy savings. The design of each program focused on addressing several known barriers including: limited homeowner knowledge on the benefits of energy efficiency, lack of financing options, lack of community support for energy efficiency programs, and lack of trained market actors including contractors and real estate professionals. The programs were able to make progress on addressing all of these barriers and were most successful in offering financing options and training market actors. The most challenging barriers proved to be the act of building a market for energy efficiency where none previously existed, convincing homeowners of the value in investing in energy efficiency (and therefore completing retrofits), engaging electric and natural gas utilities to partner on delivery, and achieving the overall project target of 1,365 completed retrofits. The components that proved to be the most valuable to program success were engaged contractor networks that could promote and endorse the program, partnerships with local business and organizations, and the access to rebates, incentives and financing mechanisms. The programs were successful in building relationships with a variety of community participants including: local contractors, Associations of REALTORS, home builders associations, universities, utilities, local and state governments, and other non-profit organizations. Throughout this program, 933 building audits and 795 building retrofits were completed making homes in Alabama more comfortable, less expensive to operate, more valuable to the marketplace, and safer and healthier for families. Continuing on this momentum, Nexus Energy Center plans to continue operating and expanding operations in Alabama as a Home Performance with ENERGY STAR sponsor and will continue to provide energy services and education to communities in Alabama.

Grimes, Elizabeth M.↗

Building America Case Study: Zero Energy Ready Home and the Challenge of Hot Water on Demand, Denver, Colorado

"This report outlines the steps a developer can use when looking to create and implement higher performance standards such as the U.S. Department of Energy (DOE) Zero Energy Ready Home (ZERH) standards in a community. The report also describes the specific examples of how this process was followed by a developer, Forest City, in the Stapleton community in Denver, Colorado. IBACOS described the steps used to begin to bring the DOE ZERH standard to the Forest City Stapleton community based on 15 years of community-scale development work done by IBACOS. As a result of this prior IBACOS work, the team gained an understanding of the various components that a master developer needs to consider and created strategies for incorporating those components in the initial phases of development to achieve higher performance buildings in the community. An automated scoring system can be used to perform an internal audit that provides a detailed and consistent evaluation of how several homes under construction or builders' floor plans compare with the requirements of the DOE Zero Energy Ready Home program. This audit can be performed multiple times at specific milestones during construction to allow the builder to make changes as needed throughout construction for the project to meet Zero Energy Ready Home standards. This scoring system also can be used to analyze a builder's current construction practices and design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Zero Energy Ready Home Case Study: Transformations, Inc., Production House, Devens, Massachusetts

A collaboration with Building America team Building Science Corporation helped this builder win a 2013 Housing Innovation Award in 2013—a 2,508-ft2 home built on speculation in the Devens, MA, subdivision. For the above-grade walls, the super-insulated building shell starts with 12 inch thick double walls composed of two 2x4 16-inch on-center walls spaced 5 inches apart. The space between the walls is filled with low-density (open-cell) spray foam for an insulation value of R-45.

advanced framing↗

Investigating Low-Altitude Constellations of Ad-Hoc Lunar PNT System for Distributed Spacecraft Autonomy

In this study, we examine a low-altitude Lunar Position, Navigation, and Timing (LPNT) constellations and the localization performance of Centralized Extended Kalman Filter (CEKF) and Decentralized Extended Kalman Filter (DEKF) algorithms. The primary investigation involves a 100-node swarm operating at a 100 km altitude, in contrast to previous studies that examined a 21-node asset in a frozen-orbit at 5,500 km. The autonomous operation of large-scale swarm is based on two-way Inter-Satellite Link (ISL) measurements, which involve pseudoranges and relative velocities among swarm nodes. We perform a numerical assessment of the two filtering approaches, utilizing ‘fully sampled’ measurements from all available assets as well as ‘two ISL’ measurements where each spacecraft is restricted to only two antennas. This research includes an analysis of CEKF under 2-ISL constraints and evaluates the performance of DEKF in a 100-node swarm, which has not been explored in previous studies. In addition, we examine the impact of increasing the sampling frequency for DEKF, showing that the update cycle can be shortened from a 10-minute interval. A novel approach for ‘2-ISL limited’ DEKF will also be introduced, using a matching formulation that exhaustively enumerates all potential matches. This study provides valuable insights into large-scale distributed swarm operations, considering various filter configurations, sampling frequencies, matching strategies, and scalability of CEKF and DEKF for low-altitude LPNT applications. The Lunar PNT technology plays a key role in providing reliable and robust navigation services on the Moon's surface and the South pole, where the primary Lunar missions are planned. To support upcoming Lunar missions, including small satellites from NASA's Commercial Lunar Payload Services program, the Lunar PNT system must be adaptable to smaller platforms like CubeSats. Driven by the growing involvement of public and private exploration partnerships, the traditional low Earth orbit missions are shifting to beyond geosynchronous orbit [1]. These upcoming missions aim to foster a sustainable and innovative exploration program, in collaboration with commercial and international partners, to facilitate human expansion throughout the solar system and return new knowledge and opportunities to Earth [2]. As part of this trend, there are increasing efforts to utilize science missions in Lunar orbit to develop a non-dedicated and ad-hoc PNT network system. Two traditional approaches, the Deep Space Network (DSN) and the weak signal Global Positioning System (GPS), are established deep-space navigation technologies for missions beyond the geosynchronous orbit. Beginning in 1958, the DSN was developed to communicate with the Explorer 1 spacecraft based on the use of radiometric tracking in spacecraft navigation [3]. The DSN is capable of providing nearly unfettered coverage to spacecraft beyond low-Earth orbit (LEO), however, increased space mission volume has created concerns about future expectations of DSN usage for spacecraft navigation [4]. For cislunar mission applications, the position accuracy using DSN achieves 100 m (3σ) with at least three geometrically diverse ground stations when using radiometric tracking alone [5]. The DSN's dependence on Earth-based ground stations restricts its operational capabilities to periods of Earth visibility. This limitation, coupled with its poor localization performance, renders the DSN unsuitable for future lunar missions that demand continuous tracking and precise positioning. To satisfy the increasing requirements of DSN in Lunar applications, spacecrafts are also required to improve their onboard antenna power and efficiency of the transmission. However, there is an important aggregate cost trade between adding capabilities to every spacecraft and adding to a capacity on the ground that serves multiple spacecraft [6]. A weak GPS system can provide PNT service while the user spacecraft is bound to the Moon, leveraging a single, steerable high gain antenna with the relatively narrow beam which includes all the sources in its field of view [7]. However, the higher the altitude the receiver is above the GPS constellations, the poorer and the weaker are the relative geometry and the received signal powers, respectively, leading to a significant navigation accuracy reduction [8]. The transmitted power becomes weaker with increasing distance from the Earth as well as signals tracked from one of the side lobes of the GPS antenna pattern. As a results, the number of visible satellites and relative geometric condition of the GPS satellites at very high altitude drops dramatically and reduces the navigation solution accuracy. Therefore, the weak GPS system is also not an ideal way to provide PNT service to upcoming Lunar missions when considering its limited geometric condition and the recued navigation accuracy. Another navigation approach on the Moon is being developed, similar to the Global Navigation Satellite System (GNSS) on Earth, aiming to offer navigation service with continuous 24/7 coverage across the entire Lunar surface. For example, lunar communications relay and navigation systems (LCRNS) by NASA and Lunar navigation satellite systems (LNSS) by JAXA are designed to serve as dedicated Position, Navigation, and Timing (PNT) systems for the Moon. However, designing a dedicated LNSS and PNT service involves additional challenges, which are unique to the lunar environment, including limited payload capacity for the CubeSat platform, i.e., the size, weight, and power (SWaP) of the onboard clock, limited lunar ground monitoring stations, and limited financial investment as compared to the legacy Earth-GPS [9]. NASA’s focus on utilizing CubeSat platforms on the Moon leads to an alternative Lunar navigation platform that leverages the existing Lunar science and exploration assets. The small satellites used in Lunar missions can be used to create a low-cost, autonomous, ad-hoc, and on-demand mission-centric Lunar PNT swarm capable of providing PNT services to these low-cost lunar missions [10]. As upcoming Lunar missions will often operate at low-altitude about 30 km to 100 km for scientific observations and mapping purposes, the low-altitude orbital constellations could be employed to create an ad-hoc Lunar PNT system. However, several issues must be addressed, such as the instability of these orbits, which often require maintenance or are only suitable for short-duration missions, operating for fewer than 90 days. Additionally, at an altitude of 100 km, the satellites have a limited period during which they are above the horizon and capable of providing PNT service to users. The implementation of a non-dedicated, ad-hoc Lunar navigation constellation facilitates on-demand PNT services. A preliminary study of ad-hoc Lunar PNT system was conducted using 21 spacecraft in 5,5000 km altitude frozen orbits to test its feasibility and a basic performance of orbital asset localization among ad-hoc Lunar constellations in small satellites format [10]. These swarm assets are designed for autonomous localization with minimal Earth interaction, reducing dependency on bandwidth and ground resources. The design in [10] demonstrated the feasibility of a decentralized PNT approach, specifically employing a DEKF approach for state estimation, which helps minimize onboard operating costs. The DEKF method distributes computation across individual satellites, which lightens the computational load while maintaining accuracy in orbit ephemeris and clock offsets, similar to centralized systems [11]. In a follow-on study [12], each spacecraft was limited to 2 communications antennae, forcing the selection of measurements and scheduling spacecraft activities to perform the measurements. A matching algorithm is implemented to select the best measurements and schedule position estimation updates. The decentralized localization performance is also investigated with increasing levels of network degradation for swarm assets considering the impact of intermittent and permanent communication failure, to demonstrate the robustness and fidelity of the decentralized Lunar PNT service [13]. This study confirmed that the ad-hoc PNT constellations in frozen orbit are highly robust and resilient to communication failures. However, unlike frozen orbit swarm assets, the low-altitude satellites have a limited ground view at an altitude of 100 km, where the ad-hoc Lunar constellation consists of 98 low-altitude satellites, evenly distributed across seven circular polar orbital planes, alongside two satellites in a frozen orbit at an altitude of 5,500 km (Figure 1). Therefore, the number of satellites visible to ground users is significantly limited in low-altitude orbit constellations. As each visibility of a spacecraft remains intact for only a few ticks before it moves out of the field of view, the ground user encounters challenges in maintaining continuous navigation service, resulting in sparse availability and provision of Lunar PNT system. Consequently, service availability is primarily restricted to the Lunar South Pole region (Figure 2). Given these limitations and concerns, the localization performance of low-altitude swarm assets will be assessed in this study. We focus on the investigation of the localization performance of low-altitude swarm assets and ground users near the Lunar South Pole. The overall flow of the Lunar PNT simulation incorporates the DEKF approach of asset localization and the weighted least-squares approach in user localization (Figure 3). The autonomous Lunar PNT simulation is primarily implemented in MATLAB, where the DEKF based on the matching scheduler is implemented with Google’s OR-tools as a model builder and Gurobi optimization tool as a backend solver. The General Mission Analysis Tool (GMAT) is utilized to generate ephemeris data for swarm assets, and accounts for satellite orbital details, mass, and perturbations like solar radiation pressure and drag coefficients. Each ephemeris dataset is produced in the Moon International Celestial Reference Frame (ICRF) inertial coordinate system. For state estimation, the distributed swarm assets rely on two-way Inter-Satellite Link (ISL) measurements, which involve tracking pseudoranges and relative velocities between visible satellites and anchor nodes during each observation. Numerical evaluations of the decentralized localization process are conducted to demonstrate the feasibility of the low-altitude PNT system in providing reliable navigation services. The main approach involves using DEKF and CEKF to localize 100 satellites in low-altitude constellations, where the CEKF is implemented to serve as a baseline for comparing the performance of distributed algorithms. In both cases, we evaluate ‘fully sampled’ measurements from all available assets, and ‘two ISL’ measurements when spacecraft are constrained to have only two antennas. We test four estimation techniques: CEKF fully sampled, CEKF two ISL, DEKF fully sampled, and DEKF two ISL filters. As the DEKF update cycle is comprised of network setup, communication, and computations, a global broadcast network and 2-way ISL network setup will take from 4 to 6 minutes as maximum [12]. In this simulation, the DEKF update cycle is set to 10 minutes, including a 4-minute latency for obtaining and computing the actual measurement updates. We experiment an increased update cycle to demonstrate the feasibility and evaluate the impact on localization performance using various tuning values for measurement noise covariances (Figures 4 and 5). By comparing centralized and decentralized approaches using a matching algorithm, we analyze the influence of cross-correlation factors in the covariance matrix, assuming 100% reliability of all assets and measurements. The increased frequency and the adjustments of tuning parameters reveal distinct error patterns between the two scenarios. The localization accuracy of the swarm assets and ground users is assessed by taking the median error across 100 assets and one ground user (84.9°S, 137.5°E) over 7-day simulation period (Table 1). Since the user localization accuracy is significantly affected by the performance of the swarm assets, it is crucial to maintain high localization accuracy within the swarm. This study will continue to explore decentralized filtering for autonomous LPNT operations, with further investigation of an 'iterative' matching approach which enumerates every valid matching pair, planned for the following month.

Yeji Kim↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

​While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

&#8203↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Consortium for Advanced Residential Building's (CARB’s) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

2012 IECC↗

Web-Based Computational Model Builder For Nuclear Energy Advanced Modeling and Simulation (Final Report)

According to the World Nuclear Association, the U.S. is the largest producer of nuclear power worldwide. In fact, the U.S. provides over 30 percent of the world's nuclear generation of electricity. Although few new reactors have been built in the past 30 years, the association anticipates that four to six reactors may be built by 2020. The first of the reactors will be built in response to 16 license applications, which have been completed since 2007, to build 24 additional nuclear reactors. Currently, both government and industry are working to accelerate approval for the construction and design of new nuclear energy plants. The U.S. nuclear industry has already achieved significant developments in the implementation of nuclear power plants due to advancements in refueling, maintenance, and safety systems at current power plants. Meanwhile, changes in government policy, which have occurred since the late 1990s, have provided for noteworthy expansion in nuclear capacity. For example, the Energy Policy Act of 2005 evoked investment in electricity infrastructure such as nuclear power. To design future systems and continue operational improvements at existing U.S. plants, advanced modeling and simulation of nuclear reactors are crucial. We developed a Cloud/Web-based tool, HPCCloud, that enables nuclear energy firms, or other manufacturing and engineering companies, to innovate using advanced modeling and simulation. Through the Web-Based Computational Model Builder for Nuclear Energy Advanced Modeling and Simulation grant, we develop HPCCloud to simplify and democratize advanced modeling and simulation in the nuclear energy industry on a range of nuclear engineering applications. It leverages millions of investment dollars from the Department of Energy's Consortium for Advanced Simulation of Light Water Reactors (CASL) and the Office of Nuclear Energy's research and development in Nuclear Energy Advanced Modeling and Simulation (NEAMS). Our approach simplifies the workflow, alleviates the need for in-house computational science and engineering experts, and lowers the capital investments required for advanced modeling and simulation. The Cloud/Web-based simulation environment guides end-users and developers through the advanced modeling and simulation lifecycle. In addition to providing significantly improved, intuitive software, the environment offers reproducible workflows where one can save, share, and even publish the full path of data from input to final analyzed results. HPCCloud addresses identified challenges to the nuclear energy industry's use of advanced modeling and simulation. With this unique Cloud/Web-based environment, we enable an ecosystem of synergistic activities, fueling new research and development for nuclear energy. HPCCloud lays the groundwork for commercialization, through customization, technology integration, and advanced research and development services.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

New Whole-House Solutions Case Study: Singer Village - A Cold Climate Zero Energy Ready Home, Derby, Connecticut

After progressively incorporating ENERGY STAR for Homes Versions 1, 2, and 3 into its standard practices over the years, builder Brookside Development was seeking to build an even more sustainable product that would further increase energy efficiency, while also addressing indoor air quality, water conservation, renewable-ready, and resiliency. These objectives align with the framework of the U.S. Department of Energy Zero Energy Ready Home program, which builds upon the comprehensive building science requirements of ENERGY STAR for Homes Version 3 and proven Building America innovations and best practices. To meet this goal, Consortium for Advanced Residential Buildings partnered with Brookside Development to design and construct the first zero energy ready home in a development of seven new homes on the old Singer Estate in Derby, Connecticut.

AIR SEALING CEILING PLANE↗

A New Appraisal- Lessons from the History of Efforts to Value Green and High-Performance Home Attributes in the United States

Rigorous consideration of green and high-performance (“green/HP”) features is rarely included in the property valuation process._ To help illuminate why this is the case, this report takes stock of the history of efforts to improve practices, and identifies barriers that have emerged and opportunities for overcoming them. Particular emphasis is placed on what energy and environmental policymakers and other stakeholders outside the appraisal community can contribute to the broader effort to advance professional practices. The history has unfolded in parallel with turbulent periods in the housing market for which appraisers and their customers are deemed to share responsibility, followed by cycles of regulations, siloing of appraisers in the name of professional integrity, and commoditization of the valuation process itself. This pattern has important ramifications for aspirations that appraisers engage more fully in identifying and valuing the green/HP characteristics of homes. On the one hand, it is legally and ethically incumbent on appraisers to do so, yet on the other hand it is perceived as a risky avenue to follow. Risks arise where findings can be challenged as either over- or under-stating value, together with a market environment in which the complexity of their assignments increases despite downward pressure on appraiser fees. While efforts to address green/HP considerations date back to the early 1980s, the vast majority of activity has taken place within the past five years. Many players have engaged in the efforts to promote improved valuation practices. These include the Appraisal Foundation, The Appraisal Institute, Colorado Energy Office, Earth Advantage, EcoBroker, Elevate Energy, Fannie Mae, Federal Housing Administration, Home Innovation Research Labs, The Institute for Market Transformation, Northwest Energy Efficiency Alliance, National Association of Homebuilders, National Association of State Energy Officials, National Association of Appraisers, RESNET, USEPA, USDOE and its National Laboratories, the U.S. Green Buildings Council, and the Vermont Green Homes Alliance. Many activities have resulted, ranging from trainings, to data-gathering instruments, and the emergence of a literature attempting to statistically isolate the effects of green/HP characteristics on home values. In some cases, the results of studies have been overgeneralized and oversold, and embodied flawed methods. Although the green/HP community has encouraged appraisers to focus on exemplary buildings (e.g., LEED or ENERGY STAR Certified), any level of green or energy performance can in fact influence value, including below-average performance (a.k.a. “brown discount”), irrespective of whether or not the building has been formally rated. This overly narrow focus represents a significant missed opportunity. Other surmountable challenges include limitations to non-appraisers’ understanding of the appraisal process (and practical constraints therein). A byproduct of this can be unrealistic expectations of what appraisers can and will do in the marketplace. These challenges notwithstanding, the environment for moving forward has improved. There is better data today (a critical need); expanded efforts to disclose energy use information (characteristics, consumption, bills); improved and more pervasive building energy codes, building rating and labeling initiatives; and a host of federal, state, and local policies that have collectively brought green/HP practices much more into the mainstream. Meanwhile, a renewed focus on professional standards of care and competency for assessing green/HP homes make it increasingly important for appraisers to consider these factors in their assignments. Despite the past four decades of studies, there is little if any discernible uptake of these practices by the appraisal practice at large. It would behoove interested parties to step back and consider what new strategies might be productive. A key element of any new plan should be to reset the nature of interactions with the industry, with the goal a more collaborative, two-way discussion to help improve outsiders’ understanding of the valuation process. It is not only the appraiser that needs to be engaged and could benefit from awareness raising. Homeowners, builders, lenders, utilities, insurance companies should also provide input on how green/HP factors impact property valuations and ways to accurately reflect these considerations in appraisals and real estate transactions more broadly. Given extensive inertia within the appraisal industry and a mixed history of interactions with the non-appraisal stakeholders, it is unlikely that the status quo will achieve much unless followed with more coordinated and persistent efforts. Workshops, studies, and memoranda of understanding will not on their own have much impact, and do not address deeper structural issues. Expectations are often unrealistic and not attentive to real-world constraints faced by appraisers. The report identifies key barriers impeding more thorough consideration of green/HP factors in residential real estate appraisals, and solutions for mitigating them. Barriers • Although industry standards of practice caution against bias of any sort, a skeptical predisposition towards “green” is reinforced by information deficiencies. • Information deficiencies result from the lack or difficulty of obtaining usable data on green/HP features in subject properties as well as valid sales comparisons or cashflow analyses. • Competency deficiencies, such as lack of conversancy in relevant technical topics, leads to oversights, and disjointed treatment of relevant information. • Time/cost pressure and process commoditization (e.g., template-based approaches) result from highly constrained budgets, quick turn-around times expected of appraisers, and standardized practices that were not developed with green/HP considerations in mind. • Professional differences between appraisers and sustainability professionals include divergent objectives, the former being market observers and the latter market influencers. • Risk aversion arises from multiple concerns including veracity, accuracy, and persistence of energy data, impacts of operational choices, new sources of appraiser liability associated with green/HP assessments, industry pressures not to over-value buildings or suggestion of bias, and concern about spending non-billable time on complex assignments. • A public policy vacuum has been created by disjointed and uncoordinated efforts from public-sector stakeholders, insufficient efforts to discuss and understand the appraisal industry and process, and a perception by some valuation professionals that green/HP is oversold. Opportunities • Elevating the competency of appraisers can be achieved through a combination of improved industry standards of care and equal-access training and professional development offerings. • Development of better information resources must focus on building-level information that provides robust documentation as well as aggregate sales-comparison data and other contextual information such as local codes, typical upgrade costs, energy prices, etc. • Improved energy benchmarking and rating tools could provide appraisers with information more well-adapted to their particular needs, which differ from those of typical audiences such as energy managers. • Better characterizing and managing risk will enable appraisers to cope with uncertainties in performance information, and help identify where risks may be introduced or mitigated by green/HP features, including higher costs or obsolescence of poorly-performing buildings. • Integrating disaster resilience and sustainability in appraisals would recognize important synergisms among these features, including durability and ability of green/HP buildings to better withstand external hazards. • Mitigating the problem of additional time/cost for performing assignments is an essential need that can be addressed by providing easier access to information and analytic procedures, perhaps coupled with new resources to defray the associated costs. • Enhancing demand for improved appraisals is a fundamental need, and depends on owners, developers, lenders, and others soliciting competent appraisers to perform scopes that expressly call out green/HP considerations, and to critically review the work product for compliance before acceptance. • Engaging new market participants, such as energy utilities and insurance companies can ensure fuller representation and participation of market stakeholders already engaged in green/HP activities and capable of furnishing valuable data and managing associated risks. Cutting across these individual activities, there is a need for outside stakeholders to formulate and follow a roadmap instead of piecemeal initiatives, bridging the professional/cultural divide between appraisers and green/HP communities, and tracking progress in order to know what is working. A more coherent communication and training strategy is needed, as the appraisal industry is highly fragmented, with two-thirds of appraisers opting out of membership in trade associations. In sum, while there is no silver bullet for advancing the practice of valuing green/HP features, there are concrete opportunities. Parties seeking solutions must identify barriers they wish to address and select from among potential initiatives that map to those barriers. Close collaboration with the appraisal community is critical, as non-appraisers have historically obtained limited traction with this industry due to lack of understanding of the nuances involved in the valuation profession. Large organizations and agencies should have a united approach; the perception or reality of a fragmented and uncoordinated strategy is unsettling for prospective partners in the appraisal industry. This requires improved communication and education within and among these communities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Energy Efficient Roof System

Energy consumption in buildings represents 40 percent of primary U.S. energy consumption, split almost equally between residential (22%) and commercial (18%) buildings.1 Space heating (31%) and cooling (12%) account for approximately 9 quadrillion Btu. Improvements in the building envelope can have a significant impact on reducing energy consumption. Thermal losses (or gains) from the roof make up 14 percent of the building component energy load. Infiltration through the building envelope, including the roof, accounts for an additional 28 percent of the heating loads and 16 percent of the cooling loads. These figures provide a strong incentive to develop and implement more energy efficient roof systems. The roof is perhaps the most challenging component of the building envelope to change for many reasons. The engineered roof truss, which has been around since 1956, is relatively low cost and is the industry standard. The roof has multiple functions. A typical wood frame home lasts a long time. Building codes vary across the country. Customer and trade acceptance of new building products and materials may impede market penetration. The energy savings of a new roof system must be balanced with other requirements such as first and life-cycle costs, durability, appearance, and ease of construction. Conventional residential roof construction utilizes closely spaced roof trusses supporting a layer of sheathing and roofing materials. Gypsum board is typically attached to the lower chord of the trusses forming the finished ceiling for the occupied space. Often in warmer climates, the HVAC system and ducts are placed in the unconditioned and otherwise unusable attic. High temperature differentials and leaky ducts result in thermal losses. Penetrations through the ceilings are notoriously difficult to seal and lead to moisture and air infiltration. These issues all contribute to greater energy use and have led builders to consider construction of a conditioned attic. The options considered to date are not ideal. One approach is to insulate between the trusses at the roof plane. The construction process is time consuming and costs more than conventional attic construction. Moreover, the problems of air infiltration and thermal bridges across the insulation remain. Another approach is to use structurally insulated panels (SIPs), but conventional SIPs are unlikely to be the ultimate solution because an additional underlying support structure is required except for short spans. In addition, wood spline and metal locking joints can result in thermal bridges and gaps in the foam. This study undertook a more innovative approach to roof construction. The goal was to design and evaluate a modular energy efficient panelized roof system with the following attributes: (1) a conditioned and clear attic space for HVAC equipment and additional finished area in the attic; (2) manufactured panels that provide structure, insulation, and accommodate a variety of roofing materials; (3) panels that require support only at the ends; (4) optimal energy performance by minimizing thermal bridging and air infiltration; (5) minimal risk of moisture problems; (6) minimum 50-year life; (7) applicable to a range of house styles, climates and conditions; (8) easy erection in the field; (9) the option to incorporate factory-installed solar systems into the panel; and (10) lowest possible cost. A nationwide market study shows there is a defined market opportunity for such a panelized roof system with production and semi-custom builders in the United States. Senior personnel at top builders expressed interest in the performance attributes and indicate long-term opportunity exists if the system can deliver a clear value proposition. Specifically, builders are interested in (1) reducing construction cycle time (cost) and (2) offering increased energy efficiency to the homebuyer. Additional living space under the roof panels is another low-cost asset identified as part of the study. The market potential is enhanced through construction activity levels in target markets. Southern markets, from Florida to Texas account for 50 percent of the total new construction angled-roof volume. California contributes an additional 13 percent share of market volume. These states account for 28 to 30 million squares (2.8 to 3 billion square feet) of new construction angled roof opportunity. The major risk to implementation is the uncertainty of incorporating new design and construction elements into the construction process. By coordinating efforts to enhance the drivers for adoption and minimize the barriers, the panelized roof system stands to capitalize on a growing market demand for energy efficient building alternatives and create a compelling case for market adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Energy Efficiency of Air Separation via Hollow Fiber Sorbents

This report summarizes the work performed under the Department of Energy’s National Energy Technology Laboratory (DOE-NETL) Advanced Energy Systems Program award number DE-FE0026163 Improving Energy Efficiency of Air Separation via Hollow Fiber Sorbents. The overall objective of the project was to develop technology to produce oxygen for use in coal gasification processes at a significantly lower cost than that of the commercial state-of-the-art technology. The focus of the project was development and optimization of hollow fiber sorbents for use in a pressure swing adsorption (PSA) process for producing oxygen from air. The key technical advancement under this program was the development of a hollow fiber sorbent capable of producing oxygen in a PSA process. PSAs produce oxygen by using a beaded zeolite material (typically lithium exchanged zeolites or LiX) that selectively adsorb nitrogen over oxygen. For a fiber to adsorb nitrogen, LiX needed to be integrated into a polymer fiber and then activated at over 350C to remove residual moisture. After screening multiple materials and process techniques, Matrimid/LiX hollow fibers were produced that were able to withstand the activation and had crystalline nitrogen capacity close to pure LiX crystals. The fibers were dual layer fibers with a barrier layer isolating the hollow bore from the LiX embedded layer. The barrier layer was formed from an Ultem® based solution. The hollow bore was intended for encapsulating phase change materials to ensure isothermal PSA operation. Modeling work from the project suggested that the benefits of this additional complexity were marginal, thus the team fabricated non-hollow fibers comprised of Matrimid and LiX. The Matrimid/LiX fibers were loaded into a module and tested on a bench scale PSA unit. The fibers were able to separate oxygen from air, but the purity and recovery were lower than expected and lower than traditional beaded LiX zeolites, although modeling results suggested that the bed sizes for fiber sorbents could be half the size of a beaded LiX bed. Additional work will be needed to understand the shortfall and to produce fiber sorbent modules with performance equal to the targets set for this program. In addition to producing fibers, modeling work was carried out at both the fiber level and process level to guide both fiber sorbent development and to determine the optimal process conditions for a PSA using fiber sorbents. A 2D hollow fiber model was developed in gPROMS Model Builder. This model was based on literature data for mass transfer and other parameters. This model used a basic single bed PSA process to determine important fiber properties and process conditions for achieving high oxygen recovery. The preliminary 2D fiber model was a valuable tool, however, for step-out technologies, such as a PSA process with fiber sorbents, intelligent optimization and plant control was needed to effectively determine minimum power designs. Therefore, a gPROMS Process Builder-based optimization tool was developed with an “Automated Cycle Optimizer” model that was able to determine optimal cycle conditions for a fiber sorbent PSA. The results from the optimizer were used in the final power analysis. Flow sheet analysis and techno-economic analysis (TEA) was carried out to determine a lower power solution versus the baseline case. The original project scope suggested that the fiber sorbent PSA could be used to debottleneck a cryogenic air separation plant (cryo-ASU) with the combined plant having lower power than a standalone cryo-ASU. However, early flowsheet analysis showed that the PSA/cryo-ASU concept would not lead to a lower power solution. However, further flowsheet analysis suggested that an oxygen PSA combined with a nitrogen PSA could have lower power versus state-of-the-art air separation technology. Work concluded with the TEA showing a fiber sorbent oxygen PSA combined with an advanced nitrogen PSA could be up to 8% lower power versus the base case cryo-ASU. Overall, there is significant potential remaining for the zeolite hollow fiber sorbent concept, and this project successfully identified -- and ultimately remedied -- many technical challenges associated with scale-up.

01 COAL, LIGNITE, AND PEAT↗

The Energy in Modular (EMOD) Buildings Method: A Guide to Energy-Efficient Design for Industrialized Construction of Modular Buildings

Industrialized construction has immense potential to address the growing need globally to build and upgrade the building stock to be affordable, energy-efficient, and resilient. It can also help achieve the United States' goal of a 50% reduction in U.S. greenhouse gas (GHG) emissions by 2030. Despite this potential, and the ever-increasing push for electrification and decarbonization of households in the United States, industrialized construction has not yet been leveraged specifically to help address these challenges and accelerate the pathway to meet these goals. The National Renewable Energy Laboratory (NREL) aims to claim this missed opportunity by focusing on delivering affordable, grid-efficient net-zero energy (NZE) modular buildings for underserved communities to ensure an equitable transition to the future of clean energy, accelerate decarbonization of the built environment, and support the development of a high-productivity construction and energy efficiency workforce. The Energy in Modular (EMOD) method is our approach to designing, producing, and delivering affordable, net-zero energy, low-carbon, and healthier buildings at scale. The following energy efficiency strategies are part of the scope of this guide: envelope thermal control, envelope infiltration control, mechanical, electrical, and plumbing systems, smart controls, and solar plus storage. We draw synergies between design for manufacturing and assembly, process optimization, retrofit technologies, and digitization. Our goal is to influence the improvement and production of buildings to increase performance, enhance energy efficiency, and reduce GHG emissions. This guide documents the research and development efforts initiated by a set of design objectives to "modularize" a set of energy efficiency and low-carbon strategies into a housing unit while preserving and enhancing energy efficiency benefits and decarbonization pathways. This guide is intended to serve as a framework for housing developers, housing agencies, architects, energy experts, and process engineers or factory operator personnel who are critical to today's modular builder teams. This guide focuses on specific energy efficiency strategies, decarbonization pathways, and associated processes as part of NREL's research efforts. Stakeholders may substitute other means, methods, and technologies for the ones evaluated in this study.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MOOSE Framework Meshing Enhancements to Support Reactor Analysis

MOOSE-based physics codes require an input finite element mesh on which the physics solution is calculated, reported, and transferred to other physics codes. The use of difficult-touse, external licensed software is often required to generate high quality meshes for reactor geometries. High-fidelity geometry modeling also requires elaborate tracking of groups of elements for material property assignment and output reporting which can be considerably complex for the user to identify and maintain. Under the U.S. Department of Energy Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, several meshingrelated enhancements have been developed for the MOOSE framework to address user challenges in creating finite element meshes for advanced reactor geometries. MOOSE mesh generators have been developed to mesh hexagonal geometries (pins, ducted assemblies, and cores) commonly found in liquid-metal cooled fast reactor concepts. The mesh generator used for hexagonal pin cells is generic for regular polygons and therefore may also be used for Cartesian pin cells. Hexagonal pin cells can be stitched into ducted assemblies, and assemblies can be stitched together into a core. The user may specify region ids, region names, and other preferences on the mesh. This control is useful for later material mapping in the MOOSE-based physics codes input. A capability was also developed for meshing rotating control drums including determination of material volume fractions in each mesh element as a function of time. Control drum meshes may be stitched to other hexagonal assemblies to create a core configuration. Additional mesh generators were developed that wrap around the hexagonal meshing capabilities and utilize “extra element integer” ID values on each element. In regular Cartesian or hexagonal assemblies or cores, the bookkeeping of element groups for both material assignment and output reporting can now be automated through assignment of pin, assembly, core, axial and depletion id values stored as extra element integers. The extra element tags on the mesh greatly speed the reactor analyst’s efforts to map materials to meshes, track depletion zones, and parse output such as axial pin power distributions. At the highest level, pin, assembly, and core mesh generators (with this reactor terminology) have also been developed to easily generate regular Cartesian and hexagonal cores, including axial extrusion. These reactor geometry builders call upon the previously mentioned capabilities to produce analysis-ready 3D meshes including material assignments. Open source mesh triangulation capabilities were also investigated for integration into the MOOSE framework to address the need for meshing the core periphery region which extends from the irregular outer assembly border to a cylindrical boundary. Options are limited due to licensing constraints, and the recommendation is pursue building a native MOOSE Delaunay triangulator routine with full functionality. Finally, a series of verification problems were performed with NEAMS physics tools. All developed capabilities will be available in the new open-source “Reactor” module of the MOOSE framework, which is accessible to any MOOSE-based NEAMS physics tool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantifying microbial roles in environmental iron oxidation via an integrated kinetics, `omics and metabolic modeling study (Final Report)

Iron oxyhydroxides are extremely reactive components of environmental systems, and therefore exert a strong influence on biogeochemical cycles. These oxyhydroxides strongly adsorb many biologically-relevant elements, including organic carbon and phosphate, as well as a wide range of metals including uranium and actinide species. Thus, the formation mechanism of iron oxyhydroxides are key to understanding both nutrient and contaminant cycling. Microorganisms can catalyze iron oxidation and promote the formation of Fe biominerals and thus are increasingly recognized as important players in biogeochemical cycling. However, it is completely unknown how much of environmental iron oxidation is biologically mediated versus abiotic, and various challenges in studying microbial iron oxidation have hindered accurate incorporation into hydrobiogeochemical models. The overarching goal of our work was to quantify and constrain microbial iron oxidation rates and use ‘omics to gain insight into the controls on this process, while developing tools to enable integration of biotic iron oxidation into hydrobiogeochemical models. Our work focused on the Savannah River Site (SRS) in South Carolina, where extensive microbial iron oxidation has been observed. At Tims Branch, part of the Argonne National Laboratory Wetland Hydrobiogeochemistry Science Focus Area (Argonne SFA), where groundwater discharges into a stream, iron-oxidizing microbial mats form and appear to be a major sink of uranium. In the wetlands that surround Tims Branch, there are wide swaths of iron microbial mats and flocs (mobilized mat). We measured biotic and abiotic iron oxidation rates using mats and water sampled from these sites and found that iron oxidation is primarily carried out by chemolithotrophic microorganisms. The resulting rate constants can be incorporated into models. These mats were characterized by metagenomics and metatranscriptomics, which showed that aerobic chemolithotrophs were the dominant iron-oxidizing bacteria (FeOB), and these included Gallionellaceae and Leptothrix, and possibly Rhodoferax, which is known as an Fe-reducer but may also oxidize Fe(II). This demonstrated that diverse FeOB can coexist and suggests that there are a range of niches and therefore drivers of chemolithotrophic iron oxidation. Analysis of reconstructed genomes strongly suggests that a major factor in diversity is carbon source, as genomes contained varied pathways for autotrophy and heterotrophy. We performed an in-depth analysis of Leptothrix ochracea genomes, since this sheath-former is one of the primary mat builders, yet its physiology remained unresolved. A combination of genomics, transcriptomics, and metabolic modeling suggest that L. ochracea grows mixotrophically using a combination of Fe(II) and organics for energy and both inorganic and organic carbon to create biomass. This contrasts with the largely autotrophic Gallionellaceae (Gallionella, Sideroxydans, and Ferriphaselus) also present in the mats and flocs. Remarkably, multiple FeOB, both Leptothrix and Gallionellaceae, showed activity in response to Fe(II) in live mat incubations. We tracked the gene expression of individual MAGs to Fe(II) and found that various autotrophic and heterotrophic FeOB responded to Fe(II), increasing expression of both carbon fixation and organic utilization genes. The results of the integrated field, kinetics, and omics studies give detailed insight into 1) the taxa that oxidize Fe, and 2) how they connect Fe, C, and N cycles. Towards the goal of connecting omics data to hydrobiogeochemical models, we worked with the KBase team to create a template metabolic model for chemolithotrophic iron oxidation. We initially modeled the well-characterized isolate Gallionellaceae Sideroxydans lithotrophicus, and also applied the model to the mixotroph L. ochracea. In all, we have characterized diverse FeOB in a representative wetland system and solved key problems that enable better incorporation of iron-oxidizing microbes into hydrobiogeochemical models.

54 ENVIRONMENTAL SCIENCES↗

Comfort in High-Performance Homes in a Hot-Humid Climate

TO5 2.3.2: Large-Scale Temperature Study Although space-conditioning systems are required to meet standards such as those in the Air Conditioning Contractors of America (ACCA) Manual RS (Rutkowski 1997) and the ASHRAE Standard 55 (ASHRAE 2013) comfort criteria, little is known about how space-conditioning systems are actually operating in the field and if these systems are meeting those standards. Unconventional space-conditioning systems may be necessary for low-load homes in the future. It is important to know how current systems are functioning in existing homes and to what temperatures occupants typically set the thermostats in their homes. The U.S. Department of Energy's Building America research team IBACOS set out to find some answers. By using low-cost data loggers and occupant surveys to monitor 37 single-family homes that have standard heating, ventilating, and air-conditioning (HVAC) equipment, the team gained insight into how sensitive occupants are to comfort in their homes relative to the ACCA and ASHRAE standards. This study focused on one climate zone (hot-humid); however, future studies may find differences among occupants- ideas of thermal comfort in other climate zones. Data were collected from installed sensors during a 2-month period from late August 2014 through late October 2014. The final aspect of this project was to review the business metrics associated with builders involved in a comfort and performance guarantee program. The results of this study-taken as an aggregate-show that the homes provided room-to-room temperature differences less than 6 degrees F 95% of the time. Temperature differences were less than 4 degrees F 80% of the time. Some homes showed better or worse performance. On average, two-story homes had a 3.3 degrees F temperature difference between rooms; single-story homes had an average of a 2.2 degrees F temperature difference between rooms. Occupants who did not use programmable thermostats had an average set point of 75 degrees F. Homes in which the thermostats were programmed with a setback schedule showed a median baseline temperature value of 74 degrees F and had a median afternoon setback of 75 degrees F. System runtime was analyzed and showed that the room-to-room temperature uniformity in some homes worsened during an on cycle, whereas the uniformity improved in other homes. That is, when the system was running, some rooms were receiving too much or too little air relative to the rest of the house, and the temperatures in those rooms were moving away from the temperatures of the other rooms in the house. Finally, analysis of the thermostat data shows a wide degree of variability among homes in the study. Interpretation of the measured data suggests that 21 occupants made no regular adjustments to the thermostats in their homes, seven had regular setbacks, seven showed varying setbacks, and 10 appeared to follow no pattern (with random adjustments). Ultimately, the data show that current systems are maintaining expected levels of comfort. As expected, it is more challenging to maintain a uniform temperature in all rooms of two-story homes, and future systems should address this issue. Furthermore, the data show that the majority of homes maintained relative humidity levels below 60% without any supplemental dehumidification

ACCA Manual RS↗