Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building codes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The EGS Collab Project: Learnings from Experiment 1

The primary objective of the EGS Collab Project sponsored by DOE is to increase the understanding needed to efficiently implement enhanced geothermal systems (EGS). One goal of the EGS Collab project is to create a collaborative research environment in which to study stimulation of crystalline rock at the 10 meter scale. Key to this effort is the collection of high quality data to allow comparison to numerical coupled process models in an effort to build confidence in the codes and modeling techniques used. In response to this, the EGS Collab team has created an underground test bed at the Sanford Underground Research Facility (SURF) in Lead SD at a depth of approximately 1.5 km to examine hydraulic fracturing (Experiment 1). We are currently designing a second test bed aimed at investigating shear stimulation (Experiment 2). At the Experiment 1 location, we have characterized our host rock using laboratory testing and numerous field-based geophysical and geological techniques, and created a well-instrumented test bed to allow us to carefully monitor stimulation events and flow tests. In addition to the installed geophysical sensors, we have used tracer tests, differences in the ambient microbial communities at flow collection locations, and cold water injection to inform us about dynamic flow pathways. In Experiment 1, we have hydraulically stimulated the host rock in a number times at several locations in one well, creating new fractures that connect to existing fractures between the injection and production boreholes. We have performed long-term ambient and chilled water injection tests as an analog to EGS, and have monitored system changes resulting from these water injections through geophysical monitoring, flow and pressure measurements, tracer tests, and microbiology. Here, we summarize the tests performed, issues identified including poroelastic and thermoelastic effects, Joule-Thomson effects, restarting effects, indications of flow channeling, and the primary learnings from Experiment 1.

Enhanced Geothermal Systems, EGS Collab, stimulati↗

Hands-on with OWL: the Oak–Ridge Wang–Landau Monte Carlo software suite

The Oak–Ridge Wang–Landau (OWL) package is an open-source scientific software specialized for large-scale, Monte Carlo simulations for the study of materials properties at finite temperature. In this paper, we discuss the main features and capabilities of OWL, followed by detailed descriptions of building and running the code. The readers will be guided through the usage and functionality of the code with a few hands-on examples. This paper is based on a tutorial on OWL given at the 32nd Center for Simulational Physics Workshop on Recent Developments in Computer Simulation Studies in Condensed Matter Physics.

Li, Ying Wai↗

Modeled Results of Four Residential Energy Efficiency Measure Packages for Deriving Advanced Building Construction Research Targets

The Advanced Building Construction (ABC) Initiative from the U.S. Department of Energy Building Technologies Office is working to accelerate industrialized construction innovations for decarbonizing buildings. To inform performance and cost targets for research under the ABC Initiative, this analysis used the ResStock™ tool to evaluate the energy savings, utility bill impacts, and carbon emissions impacts of four simulated upgrade packages with specific target performance levels on a large sample of residential dwelling units (approximately 550,000) representative of the U.S. housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Multi-family Construction: A Field Study of Energy Code Compliance and Performance through Offsite Prefabrication

Prefabrication in a controlled, factory setting may improve the energy code compliance and energy performance of modular buildings compared to traditional site-built buildings. To test this premise, the work detailed in this DOE-funded commercial field study (EE0009082) compares the energy code compliance of 25 modular and 30 site-built multifamily buildings under construction in Los Angeles, San Francisco, Philadelphia and Seattle representing climate zones 3B, 3C, 4A and 4C respectively. This dataset includes full data on 20 modular and site-built buildings and partial data on 35 modular and site-built buildings that had started prior to or were completed after the 18-month data collection period. This study also compares the post-occupancy energy performance or energy use intensity (EUI) of an additional 23 modular multifamily buildings and 128 site-built multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

Electric Readiness in Residential Energy Code: Technical Brief

This technical brief provides requirements for electric readiness that could be incorporated into model residential energy codes. It provides background on the basis and benefits of the provisions, and model code language that can be plugged into the IECC or adapted into other energy codes. This brief has been updated to reflect changes in the 2024 IECC.

2021 IECC↗

National Cost-Effectiveness of the Residential Provisions of the 2024 IECC

This analysis focuses on single-family and low-rise multifamily residential buildings based on the International Energy Conservation Code (IECC). The IECC is developed by the International Code Council (ICC) on a 3-year cycle through a public development and consensus process. While proponents of code changes often include the energy and cost-effectiveness criteria for their respective code change, the IECC process does not include an energy or cost-effectiveness analysis of the entire edition of the code. PNNL evaluated the cost effectiveness of the changes in the prescriptive and mandatory residential provisions of the 2024 edition of the IECC, hereafter referred as the 2024 IECC, compared to those in the prior edition, the 2021 IECC. The simulated performance path and the Energy Rating Index (ERI) path (introduced in the 2015 IECC) are not considered in this analysis due to the wide variation in building construction characteristics that are allowed.

2024 IECC↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

End-Use Analysis of ASHRAE Standard 90.1-2019

This article summarizes the analysis conducted by Pacific Northwest National Laboratory (PNNL), assessing expected end-use energy consumption in commercial buildings, based on recent editions of the model energy code for the commercial sector, ANSI/ASHRAE/IES Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings. The results represent simulated energy use based on) Commercial Prototype Building Models1 across representative climate zones in the United States, as defined by Standard 90.1. PNNL examined the resulting simulation outputs to assess how energy is used across primary systems within prominent U.S. commercial building types to understand how energy is used in each building type at the end-use level and to identify areas for improvements in future code cycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating Health and Energy Efficiency in Healthcare Facilities

This report presents a review of literature and current best practices along the intersection of energy efficiency and occupant health at U.S. healthcare facilities, including federally owned buildings. It also includes a review of minimum code requirements for healthcare indoor environmental quality (IEQ) and research on building measures that optimize occupant health and energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exascale models of stellar explosions: Quintessential multi-physics simulation

The ExaStar project aims to deliver an efficient, versatile, and portable software ecosystem for multi-physics astrophysics simulations run on exascale machines. The code suite is a component-based multi-physics toolkit, built on the capabilities of current simulation codes (in particular Flash-X and Castro), and based on the massively parallel adaptive mesh refinement framework AMReX. It includes modules for hydrodynamics, advanced radiation transport, thermonuclear kinetics, and nuclear microphysics. The code will reach exascale efficiency by building upon current multi- and many-core packages integrated into an orchestration system that uses a combination of configuration tools, code translators, and a domain-specific asynchronous runtime to manage performance across a range of platform architectures. The target science includes multi-physics simulations of astrophysical explosions (such as supernovae and neutron star mergers) to understand the cosmic origin of the elements and the fundamental physics of matter and neutrinos under extreme conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

Field Demonstration of the Brick Ontology to Scale up the Deployment of ASHRAE Guideline 36 Control Sequences

Many commercial buildings have a vast network of sensors as part of their building automation systems (BAS) that allows opportunities for energy consumption and cost savings by deploying advanced control sequences. However, this resource is often underutilized since BAS are typically programmed with simple control sequences with limited potential to deliver on these opportunities. The recent availability of ASHRAE Guideline 36 (G36) with advanced HVAC control sequences supports control retrofits in existing buildings to unlock much of the savings potential. However, barriers such as the lack of standard naming convention of building assets and data points, proprietary equipment and BAS, and the inherent uniqueness of buildings and their systems prevent building stakeholders from adopting any “plug-and-play” implementation of G36. Instead, control vendors must often undertake the manual and labor-intensive point mapping process to identify a data stream’s functional and spatial relationship within the HVAC system along with other relevant contexts and map it to the new control sequences. The vendor must carry out the point mapping process in each individual building since the mapping is unlikely to port over to another building. Even for the same building, the point mapping process can occur multiple times if various control vendors implement different control retrofits and/or multiple control retrofits happen over the lifecycle of the building. Then, there is the likelihood that G36 control sequences are programmed uniquely to the building, preventing the same implementation from being reused in another. Therefore, this paper presents a field demonstration of how we leveraged the Brick ontology with BACnet, OpenBuildingControl’s Control Description Language (CDL), and open-source support tools to implement scalable and portable advanced building controls. These tools provide standardized semantic descriptions and relationships of the building’s assets and data points (Brick), standardized communication protocol to read from and write to the building’s BAS (BACnet), and standardized code implementations (CDL) of standardized advanced control strategies (G36). We implemented G36’s hot water supply temperature setpoint reset in a Berkeley, CA building for this field demonstration. This field demonstration aims to show how integrating these tools may streamline the deployment of advanced control sequences such as G36 in a consistent manner regardless of differences found across buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Skewering the silos: using Brick to enable portable analytics, modeling and controls in buildings

Nearly all large commercial buildings have heating, ventilation and air conditioning (HVAC) systems, lighting systems, safety and other systems controlled by a computer—a dedicated server with a building energy management system (BMS). However, these BMSs are proprietary with each building’s assets (that is, fans, valves, pumps, and their setpoints) named and coded uniquely by the BMS vendor or engineer; building analytics and control algorithms are written specific to the assets and the building. Thus, any control updates or analytics to improve building performance—especially critical to reduce greenhouse emissions or improve load flexibility—are labor intensive and costly. The Brick schema was developed so the same analysis or control algorithms can work on a variety of buildings if each is digitally represented in a Brick data model. The goal of this project was to further the development of Brick to extend it beyond an academic project with demonstrated success in a small field study, to a practical choice for industrial and commercial stakeholders seeking to realize value from building data. To do this, we executed four objectives: (1) expand the Brick schema including its modeling capabilities and vocabulary, (2) develop tools for integrating Brick with existing digital technologies and representations in buildings, (3) develop an open-source analytics platform to facilitate use of Brick in delivering data value, and (4) demonstrate Brick-driven analytics and controls in real settings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensorium: commissioning abundant sensors with augmented reality and QR codes

In the future, it will be possible to build high-quality models of building interiors based on data from a dense fleet of sensors reporting on air volumes much smaller than a room or zone. To enable such models, we are creating technologies that allow a fleet of sensors to be commissioned quickly at low cost. Our sensor commissioning process builds a 3D model of each building interior that includes sensor positions and sensor networking information such as sensor MAC addresses. It employs multiple technologies, including augmented reality, LiDAR, QR codes, and computer vision. Sensors can be commissioned at more than 10x the speed and at less than one tenth the cost of traditional approaches.

Bier, Eric A.↗

Scoreboard

Emerging HPC machines have given rise to enhanced compute power that far outstrips the machine's ability to save large scale results for post-processing. To combat this, in situ data analysis techniques are slowly being adopted. With in situ data management favoring workflows composed of multiple simulations and analyses connected in transit on heterogeneous machines, scientists and engineers need a tool that enables them to create data extracts, visualizations, and interactively monitor and steer their simulations. Scoreboard Phase II is a next generation analysis software that supports composite in transit workflows on heterogeneous architectures and restores interactivity to in situ data analysis through simulation monitoring and computational steering. Scoreboard provides a simulation dashboard with graphs of metrics over time, controls for setting custom simulation steering parameters, controls for managing the set of data extracts being produced in the simulation, as well as the ability to explore data extracts, all from a web browser. Realizing the vision outlined in this project required research into making a system that integrates end to end from simulations all the way to the user. In situ tools generally suffer from complexity and excessive software dependencies. Scoreboard, by contrast, is easy to build and integrate into simulation codes and it provides first class FORTRAN support. The Scoreboard library is capable of in situ and in transit data analysis that can produce data extracts commonly needed for Computational Fluid Dynamics (CFD) analysis. Simulations can transparently stage data in transit to a Scoreboard Endpoint program, which can accept their data and produce the requested data extracts. This lets simulations return to their work while the Endpoint works on the analysis. Efficiently staging the data at scale was a topic of this research. Scoreboard provides the means to let the user manage data extracts and monitor/steer many simulations from a web browser. This area of the research focused on discovery of in transit network components to expose and control their steering parameters within an interactive browser-based user interface that includes: system topology, gathered metrics, notifications, dynamically-generated steering controls, and exploration of visualization data products.

Whitlock, BradJoseph [Intelligent Light] (00000001↗

PETSc/TAO developments for GPU-based early exascale systems

The Portable Extensible Toolkit for Scientific Computation (PETSc) library provides scalable solvers for nonlinear time-dependent differential and algebraic equations and for numerical optimization via the Toolkit for Advanced Optimization (TAO). PETSc is used in dozens of scientific fields and is an important building block for many simulation codes. During the U.S. Department of Energy’s Exascale Computing Project, the PETSc team has made substantial efforts to enable efficient utilization of the massive fine-grain parallelism present within exascale compute nodes and to enable performance portability across exascale architectures. We recap some of the challenges that designers of numerical libraries face in such an endeavor, and then discuss the many developments we have made, which include the addition of new GPU backends, features supporting efficient on-device matrix assembly, better support for asynchronicity and GPU kernel concurrency, and new communication infrastructure. In conclusion, we evaluate the performance of these developments on some pre-exascale systems as well as the early exascale systems Frontier and Aurora, using compute kernel, communication layer, solver, and mini-application benchmark studies, and then close with a few observations drawn from our experiences on the tension between portable performance and other goals of numerical libraries.

Exascale Computing Project (ECP)↗