Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Creating an Energy Intelligent Campus: Data Integration Challenges and Solutions at a Large Research Campus

Rich, well-organized building performance and energy consumption data enable a host of analytic capabilities for building owners and operators, from basic energy benchmarking to detailed fault detection and system optimization. Unfortunately, data integration for building control systems is challenging and costly in any setting. Large portfolios of buildings--campuses, cities, and corporate portfolios--experience these integration challenges most acutely. These large portfolios often have a wide array of control systems, including multiple vendors and nonstandard communication protocols. They typically have complex information technology (IT) networks and cybersecurity requirements and may integrate distributed energy resources into their infrastructure. Although the challenges are significant, the integration of control system data has the potential to provide proportionally greater value for these organizations through portfolio-scale analytics, comprehensive demand management, and asset performance visibility. As a large research campus, the National Renewable Energy Laboratory (NREL) experiences significant data integration challenges. To meet them, NREL has developed an architecture for effective data collection, integration, and analysis, providing a comprehensive view of data integration based on functional layers. The architecture is being evaluated on the NREL campus through deployment of three pilot implementations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building ControlScore: Research Laboratory Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore tool which captures operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ctrl-flow v0.0.1

ctrl-flow is a software that assists users in selecting a building control sequence from a library of control sequences that are implemented in the Modelica Buildings Library. The software allows selecting, configuring and editing the control sequences. It also allows exporting the sequence for use in building project design documents in Modelica-based simulations. The export will be in a json intermediate format, in the Modelica Language, in the Control Description Language and in English language format, such as in a Word document. The software functions as a web based application that includes a graphical user interface.

Wetter, Michael↗

Communication breakdown: Energy efficiency recommendations to address the disconnect between building operators and occupants

As technology advances, progressive building performance goals are met with ease and occupant behavior plays an increasingly significant role in preventing building operators from achieving those goals. However, removing occupants from participating in building control and operation is counterintuitive to the purpose of building operation. Occupant-centric control (OCC) has been suggested as a means of incorporating the occupant while simultaneously reducing the negative impact their behavior can have on building performance. As a result, operators are now tasked with incorporating OCC into their daily operation. The relationship between building occupants and operators is a critical component to OCC, and balancing occupant comfort and building performance. In this paper, we present findings from an international qualitative study of building operators with a focus on the operator and occupant relationship. This paper identifies the role operators play in OCC, how these relationships develop, and how these relationships impact building operation through two key research questions: What factors influence the quality of relationships between occupants and operators? How can the relationships between operators and occupants be improved? Subsequently, these questions revealed this relationship becomes strained when building performance is prioritized over comfort, occupants are ignored or uneducated, and feedback is negative or sparse. In short: there is a disconnection between operators and occupants. Here we propose several solutions including modifying job requirements to prioritize occupant comfort, educating occupants to make autonomous decisions that are not detrimental to operation, and creating effective communication channels for instances where operator intervention is required.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multitarget control models for building thermal comfort and indoor air quality - A critical review

The control techniques in buildings contribute significantly to thermal comfort and indoor air quality (IAQ). However, the gaps are existing for multitarget controls considering both thermal comfort and IAQ. They are: (1) both experimental and modeling control studies were conducted for thermal comfort, focusing on temperature and humidity. (2) All three (physical, grey-box, black-box) modeling approaches were investigated for temperature control. (3) Physical and grey-box modeling approach were adopted for humidity control. (4) physical models were developed for VOCs and CO2 control. (5) grey-box and black-box models were lacking for VOCs and CO2. (6) Multi-target controls were lacking for temperature, humidity and CO2s. (7) Limited studies are available for multi-target controls for temperature, humidity, and VOCs. (8) Multi-target controls are not available yet for temperature, humidity, VOCs, and CO2.

42 ENGINEERING↗

Online Verification of Transactive Control for Commercial Buildings

Commercial buildings account for a significant portion of electrical energy demand in the United States. Thus, they serve as an ideal target for energy efficiency improvements, which can reduce congestion on the electrical grid and result in lower payments for building owners. One of the proposed approaches to improving energy efficiency in commercial buildings is transactive control, which allows system components to negotiate for resources within a market. The market is designed so that the control objective is met when components consume their allocation of energy. In this paper, a method is proposed to verify that the consumption of market participants matches their allocation. The method regards energy allocations at the beginning of market periods as predictions. Using collected measurements, actual consumption is then estimated at the end of the market period. Agreement between the predicted and estimated use indicates that the system component is behaving as expected. Initial results from the deployment of this verification method in a commercial building are reported, demonstrating the practicality and utility of the method.

Follum, James D.↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (a five-lab demonstration) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, photovoltaics, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactors, control centers, and gas turbines, across five U.S. Department of Energy (DOE) national laboratories: National Laboratory of the Rockies (NLR), Idaho National Laboratory, National Energy Technology Laboratory, Lawrence Berkeley National Laboratory, and Sandia National Laboratories. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance DOE network, and are controlled via a centralized energy controller hosted at NLR's Advanced Research on Integrated Energy Systems facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Human Reliability Analysis for Digital Human-Machine Interfaces

This paper addresses the fact that existing human reliability analysis (HRA) methods do not provide guidance on digital human-machine interfaces (HMIs). Digital HMIs are becoming ubiquitous in nuclear power operations, whether through control room modernization or new-build control rooms. Legacy analog technologies like instrumentation and control (I&C) systems are costly to support, and vendors no longer develop or support analog technology, which is considered technologically obsolete. Yet, despite the inevitability of digital HMI, no current HRA method provides guidance on how to treat human reliability considerations for digital technologies.

99 GENERAL AND MISCELLANEOUS↗

Dynamic Decarbonization through Autonomous Physics-Centric Deep Learning and Optimization of Building Operations (Abstract only)

This project directly addresses the primary goal of Area of Interest 2 in the CRADA call: to advance optimization-based integrated energy management systems in commercial and residential buildings. Pacific Northwest National Laboratory (PNNL) and its industry partner PassiveLogic aim to accomplish this by reaching three key objectives. First, to ensure a broad impact in the building controls industry, PNNL will extend its open-source library for predictive control synthesis by augmenting its capabilities with data-driven self-learning of building models and auto-calibration of predictive controllers. The effort will focus on building use cases selected in collaboration with PassiveLogic. The team will specifically address the development of methods for data-driven adaptation of building models, investigation of model architectures that best address specific building types, and automated synthesis of differentiable predictive controllers that optimize diverse objectives. Second, PNNL will collaborate with PassiveLogic to integrate the aforementioned methods with PasiveLogic’s advanced controls platform. The collaborative integration effort will inform the developments under the first objective by providing specific data on the attainable performance of model learning on resource-constrained edge computing platforms. This software integration effort will increase the technical maturity of the developed libraries by exploring the use of software integration tools and methods. Third, PNNL and PassiveLogic will work to improve the technology readiness of the developed predictive controllers by testing their performance in relevant test environments, such as high-fidelity simulation, hardware in the loop, and actual test buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model-based data center cooling controls comparative co-design

This article presents a comparative simulation-based control logic design process. It uses the Control Description Language (CDL) and the ASHRAE Guideline 36 high-performing building control sequences with the Modelica Buildings Library (MBL) to demonstrate a comparative analysis of two control designs for a data center chilled water plant. Details include a description of the closed-loop plant and control design methodology, including sizing and parameterization, base and alternative (Guideline 36) control logic with software implementation structure, and outline of the simulation experimentation process. The selected control designs are paired with comparable chilled water plant configurations. The models include a chiller, a water-side economizer, and an evaporative cooling tower. The plant provides cooling at 27ºC zone supply air temperature to a data center in Sacramento, CA. The comparative simulation results examined the impacts of a selected control logic detail, and present an example model-based design application. Overall, the simulation results showed a 25% annual and a 18% summer energy use reduction for alternative controls. This shows that simulation-based control logic design performance evaluation can improve energy efficiency and resilience aspects of system controls at large.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Open Automated Demand Response Technologies for Dynamic Pricing and Smart Grid

We present an Open Automated Demand Response Communications Specifications (OpenADR) data model capable of communicating real-time prices to electricity customers. We also show how the same data model could be used to for other types of dynamic pricing tariffs (including peak pricing tariffs, which are common throughout the United States). Customers participating in automated demand response programs with building control systems can respond to dynamic prices by using the actual prices as inputs to their control systems. Alternatively, prices can be mapped into"building operation modes," which can act as inputs to control systems. We present several different strategies customers could use to map prices to operation modes. Our results show that OpenADR can be used to communicate dynamic pricing within the Smart Grid and that OpenADR allows for interoperability with existing and future systems, technologies, and electricity markets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building thermal model development of typical house in U.S. for virtual storage control of aggregated building loads based on limited available information

A building thermal model is an essential component for achieving optimal control of a building’s heating, ventilation, and air conditioning (HVAC). A self-learning grey-box model has been developed by implementing data-driven techniques and utilizing limited available information about the building. In previous research, detailed foreknown knowledge/information, e.g. physical and thermal properties of building materials, as well as sufficient number of observation points, e.g. indoor temperature sensors in different zones, are available for making the decision of model structure and parameters searching range easier. The availability of measured data and a narrowed searching range of model parameters, e.g. resistance and capacity for each wall, made the adopted algorithms quickly achieve near optimal values, which closely approximate the actual heat transfer of a building. Meanwhile, the details of pre-processing of the key inputs were seldom explained. Compared to the previous research, in this study, the available information is assumed to be limited which can fill the requirement for large scale virtual storage control of real residential community in near future, where it may be impractically or over time-consuming to acquire the detailed information for each single house. The developed model is validated by comparing the results to measured data in a recently-built home typical of the southeastern United States.

Cui, Borui↗

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems

Many studies have shown that energy savings of five to fifteen percent are achievable in commercial buildings by detecting and correcting building faults, and optimizing building control systems. However, in spite of good progress in developing tools for determining HVAC diagnostics, methods to detect faults in HVAC systems are still generally undeveloped. Most approaches use numerical filtering or parameter estimation methods to compare data from energy meters and building sensors to predictions from mathematical or statistical models. They are effective when models are relatively accurate and data contain few errors. In this paper, we address the case where models are imperfect and data are variable, uncertain, and can contain error. We apply a Bayesian updating approach that is systematic in managing and accounting for most forms of model and data errors. The proposed method uses both knowledge of first principle modeling and empirical results to analyze the system performance within the boundaries defined by practical constraints. We demonstrate the approach by detecting faults in commercial building air handling units. We find that the limitations that exist in air handling unit diagnostics due to practical constraints can generally be effectively addressed through the proposed approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupancy-Based Controls for an All-Electric Residential Community in a Cold Climate

In residential buildings, rapid improvements in sensors, communication, and information technology have enabled occupancy-based building controls. These controls utilize occupancy information and modify the operation of the heating, ventilation, and air-conditioning (HVAC) system to minimize excess HVAC energy use, especially when the building is unoccupied. This reduces the total building energy consumption and utility bills while maintaining thermal comfort. In this paper, we present two novel occupancy-driven controls - reactive control and predictive control - and compare their performance. We model an all-electric residential community based on a 27- home community in Basalt, Colorado, in the United States. We simulated various scenarios, considering different temperature setback and control algorithms, to analyze the community-scale impact of these occupancy-based controls. The results show that total HVAC energy savings in a building ranges from 1%- 20% compared to the baseline scenario without occupancy-based controls. The energy-saving potential is highly correlated with the occupancy pattern and temperature setback in the building.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Measuring Impact: Evaluating Thermal Zoning Simplification on Energy Efficiency Measures Analysis

Building Energy Modeling (BEM) is a versatile tool for designing, retrofitting, ensuring code compliance, obtaining certifications, qualifying for incentives, and enabling real-time building control. However, capturing all the details of building geometry for thermal zoning can be time-consuming, costly, and sometimes computationally challenging. As a result, modelers have been applying zoning simplification based on factors such as space functions and internal loads, as well as relying on their experience and judgment while adhering to zoning rules outlined in industry standards. Despite the prevalence of this common practice, a notable gap exists in the literature regarding studies quantifying the influence of simplified thermal zoning on the evaluation of Energy Efficiency Measures (EEMs). Recognizing this gap, this paper seeks to contribute to the field by enhancing the understanding of how the simplification of thermal zoning influences the evaluation of EEMs against a baseline design. The study utilized a medium office prototype model with a detailed floor plan featuring over 20 zones per floor covering diverse functional spaces with varying internal loads and occupancy schedules. A standard thermal zoning strategy outlined in ASHRAE Standard 90.1 Appendix G was employed as the simplified zoning method. This strategy condenses the zoning into a core zone and four perimeter zones per floor. It was compared with the detailed zoning approach, which involves one zone per space. Common Energy EEMs, such as enhanced envelope, high-efficiency appliances and equipment, and HVAC controls, were individually implemented and evaluated. The results indicate that the performance comparison between the two zoning methods varies depending on the type of measures considered. Basic measures, such as adding wall insulation, demonstrate similar energy impacts, while advanced HVAC control measures, such as static pressure reset, exhibit a more substantial difference that cannot be overlooked.

Xie, Jiarong↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Aircraft Simulation Role in Improving Flight Safety Through Control Room Training

NASA Dryden Flight Research Center uses its six-degrees-of-freedom (6-DOF) fixed-base simulations for mission control room training to improve flight safety and operations. This concept is applied to numerous flight projects such as the F-18 High Alpha Research Vehicle (HARV), the F-15 Intelligent Flight Control System (IFCS), the X-38 Actuator Control Test (XACT), and X-43A (Hyper-X). The Dryden 6-DOF simulations are typically used through various stages of a project, from design to ground tests. The roles of these simulations have expanded to support control room training, reinforcing flight safety by building control room staff proficiency. Real-time telemetry, radar, and video data are generated from flight vehicle simulation models. These data are used to drive the control room displays. Nominal static values are used to complete information where appropriate. Audio communication is also an integral part of training sessions. This simulation capability is used to train control room personnel and flight crew for nominal missions and emergency situations. Such training sessions are also opportunities to refine flight cards and control room display pages, exercise emergency procedures, and practice control room setup for the day of flight. This paper describes this technology as it is used in the X-43A and F-15 IFCS and XACT projects.

Shy, Karla S.↗

Robotic Scaffolds for Tissue Engineering and Organ Growth

The aim of tissue engineering (TE) is to restore tissue and organ functions with minimal host rejection. TE is seen as a future solution to solve the crisis of donor organs for transplant, which faces a shortage expected only to increase in the future. In this innovation, a flexible and configurable scaffold has been conceived that mechanically stresses cells that are seeded on it, stimulating them to increased growth. The influence of mechanical stress/ loading on cell growth has been observed on all forms of cells. For example, for cartilages, studies in animals, tissue explants, and engineered tissue scaffolds have all shown that cartilage cells (chondrocytes) modify their extracellular matrix in response to loading. The chondrocyte EMC production response to dynamics of the physical environment (in vivo cartilage development) illustrates a clear benefit (better growth) when stressed. It has been shown that static and dynamic compression regulates PRG4 biosynthesis by cartilage explants. Mechanical tissue stimulation is beneficial and (flexible) scaffolds with movable components, which are able to induce mechanical stimulation, offer advantages over the fixed, rigid scaffold design. In addition to improved cell growth from physical/mechanical stimulation, additional benefits include the ability to increase in size while preserving shape, or changing shape. By making scaffolds flexible, allowing relative movement between their components, adding sensing (e.g., for detecting response of cells to drug release and to mechanical actions), building controls for drug release and movement, and building even simple algorithms for mapping sensing to action, these structures can actually be made into biocompatible and biodegradable robots. Treating them as robots is a perspective shift that may offer advantages in the design and exploitation of these structures of the future.

Stoica, Adrian↗