Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Expert system terms and building tools

The characteristics of an Expert System Building Tool (ESBT) capable of inference and hypothetical reasoning are discussed. The inference capabilities of ESBTs allow such functions as classification, design-synthesis, forecasting, decision-aiding, scheduling and planning, real-time monitoring, situation assessment, the discovery of novel relations, and debugging. ESBTs are noted to have made possible order-of-magnitude improvements in expert system construction. Higher-end ESBTs are moving from LISP machines to less expensive workstations, and lower-end ones are appearing on PCs.

Gevarter, William B.↗

Cascaded Control for Building HVAC Systems in Practice

Actuator hunting is a widespread and often neglected problem in the HVAC field. Hunting is typically characterized by sustained or intermittent oscillations, and can result in decreased efficiency, increased actuator wear, and poor setpoint tracking. Cascaded control loops have been shown to effectively linearize system dynamics and reduce the prevalence of hunting. This paper details the implementation of cascaded control architectures for Air Handling Unit chilled water valves at three university campus buildings. A framework for implementation the control in existing Building Automation software is developed that requires only a single line of additional code. Results gathered for more than a year show that cascaded control not only eliminates hunting in control loops with documented hunting issues, but provides better tracking and more consistent performance during all seasons. A discussion of efficiency losses due to hunting behavior is presented and illustrated with comparative data. Furthermore, an analysis of cost savings from implementing cascaded chilled water valve control is presented. Field tests show 2.2–4.4% energy savings, with additional potential savings from reduced operational costs (i.e., maintenance and controller retuning).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Systems as Behind-the-Meter Resources for Grid Services: Intelligent load control and transactive control and coordination

To mitigate the impacts of climate change, significant reductions in emissions from all sectors of the economy are needed. The electricity generation sector has embarked on an ambitious plan to include renewable generation as part of its decarbonization efforts, and many cities and states are mandating all-electric buildings. While renewable resources will reduce emissions, they are not dispatchable, they vary temporally, and their generation is uncertain. Under these conditions, traditional approaches to managing grid reliability, where supply follows demand, will not be efficient and may not be cost-effective. Further, there is a more efficient alternative for balancing the supply–demand imbalance and for absorbing variability and uncertainty of renewable energy using distributed energy resources (DERs) as opposed to reserve generation. Because buildings consume more than 75% of total U.S. annual electricity consumption, behind-the-meter (BTM) DERs have a load flexibility of 77 GW of power and 90 GWh of virtual energy storage capacity nationwide (Kalsi, 2017). Therefore, some portion of the supply–demand imbalance can be met by these DERs at a lower cost compared to business-as-usual solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Framework to select robust energy retrofit measures for residential communities

Residential building energy retrofits are essential for enhancing environmental sustainability and reducing energy costs. The selection of retrofit measures is influenced by factors such as building systems, occupant behavior, government policy, weather variability, and climate change, all of which can significantly impact energy performance. Compared to retrofitting individual homes, evaluating and selecting optimal retrofit solutions for an entire community is challenging due to diverse residential compositions and variability present. Therefore, engineering robustness is crucial for ensuring consistent energy performance and resilience across different conditions. In this context, robustness refers to the ability of a retrofit measure to maintain its functionality and remain an optimal choice despite external disturbances or changes in inputs and conditions. This study presents a framework for evaluating the robustness of multiple retrofit measures across various building systems, occupant behaviors, and environmental scenarios at the community level. The framework comprises five key steps: scenario model development, integration of the National Residential Efficiency Measures database, energy performance simulation, cost-benefit aggregation, and retrofit solution selection. Each step enhances the framework’s robustness by incorporating the diversity of building characteristics, occupant behaviors, environmental conditions, retrofit options, and evaluation criteria. The framework’s effectiveness is demonstrated through a case study in southern Michigan in the United States, which includes 63 one-story single-family houses, 121 two-story single-family houses, and 8 townhouses. The study identifies furnace retrofits as the most robust solution for the entire community, consistently achieving source energy reductions of 4.7 %–8.0 % and payback period of 10–20 years across various scenarios. These findings are consistent with previous research, indicating the framework’s potential for broader applications in optimizing community-scale residential energy retrofits.

Shu, Lei↗

Design Requirements and Software Specification for the Autonomous Energy Management Software System for Small Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems. Many of these buildings are small (<50,000 square feet), underserved, and use rooftop units for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the rooftop units heating and cooling set points, schedules, setbacks, and optimal start can result in 20 to 25 percent reduction in electricity consumption in small commercial buildings. In addition, improving demand flexibility of these buildings will result additional cost savings for the building owner. Therefore, the Department of Energy’s Building Technologies Office approved a project to address the needs for small commercial buildings. The project is led by Pacific Northwest National Laboratory (PNNL) with Intellimation LLC as the cooperative research and development agreement partner. The primary goal of the project is to develop and validate an autonomous energy management software (AEMS) system that will continuously optimize small commercial building operations by minimizing energy consumption and cost, while providing a solution for maximizing decarbonization benefits from electrification of buildings. The work will leverage the vast experience of PNNL research and development staff who have over two decades of experience in developing and successfully transferring software technologies to the private sector. This solution will be jointly developed with Intellimation, a company that plans to use it to scale their building energy efficiency (EE) and grid services offering. Widespread deployment of the AEMS system will improve the EE and demand flexibility of the building commercial building stock. It should also support cities and states in meeting their climate change mitigation goals. This document describes the various EE and grid service features of the AEMS system, infrastructure and data required to implement those features, and how the features should be automated. It also details how the various features will be tested and validated, including field validation. The document also details what flexibility the users have and how they will be able to leverage those capabilities exercise those. The intent is to create an AEMS system that would support scalable deployment, requires minimal configuration, and is easy to maintain over its expected lifespan. The initial alpha release of AEMS system is planned for March 2023, and the beta release is planned for the summer of 2023. The final release is planned for March 2024. Section 2 of the report documents the relevant building types that AEMS is suitable for. Section 3 documents EE features that will be supported. It will also include the data requirements, hardware requirements, implementation details, and how EE features will be tested and validated. Grid service features will be documented in section 4, including data requirements, hardware requirements, implementation details, and how the services will be tested and validated. Planned next steps are described in section 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Role of Sensitivity Analysis in the Building Performance Analysis: A Critical Review

A building system is highly nonlinear and commonly includes a variety of parameters ranging from the architectural design to the building mechanical and energy system. Serving as a powerful tool to understand the complicated building system, sensitivity analysis (SA) has been receiving increasing attention in the recent decade. This review paper focused on the application of SA in the building performance analysis (BPA). First, the existing review papers on the application of SA for BPA were briefly reviewed and summarized. Then, a large amount of recent SA case studies in BPA were reviewed. The critical information regarding the implementation of a SA, such as the sampling method, the SA method, etc., were extracted and summarized. Next, an extensive analysis was performed to evaluate the role of the SA in the BPA. This includes: 1) The typical selection of the input and output parameters for the SA were visualized; 2) The uncertainty level and sampling strategies for the input parameters were investigated; 3) The principles, benefits, and drawbacks of the SA methods were analyzed and summarized; and 4) The various tools used in the SA, including the simulation software, sampling tools, and SA tools were introduced to facilitate the practitioners. Lastly, several conclusions were summarized on the role of the SA in the BPA. Suggestions were also provided to offer practical solutions to the current challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation on Aggregate Flexibility from Residential Air Conditioning Systems for Building-to-Grid Integration

To facilitate the integration of buildings to the power grid, battery-equivalent models have been proposed to characterize and quantify aggregate flexibility from building loads. An analytical method has been proposed to construct such a flexibility model for thermostatically controlled loads. Since this analytical method is derived from a simplified representation of building thermal dynamics, it is necessary to evaluate the resulting flexibility model in a more realistic context. This paper focuses on the validation of this analytical method for estimating aggregate flexibility from residential air conditioning (ACs) systems. A high-fidelity model is first developed to mimic thermal behaviors of a residential AC system through a co-simulation between Modelica and EnergyPlus. A population of virtual residential AC systems is then generated by randomizing parameters of the high-fidelity model. Finally, an aggregate flexibility model is constructed for the residential AC population using the analytical method and validated using results from simulation of the high-fidelity model. It is found that the flexibility estimated using the analytical method is with reasonable accuracy, but can be improved by explicitly incorporating heat gains into the method.

Huang, Sen↗

Minimizing the Electromechanical Stresses in Poloidal Field Coils by Optimizing their Numbers and Locations using FREDA Framework

Poloidal field (PF) and central solenoid (CS) coils play a crucial role in sustaining the equilibrium and preserving the shape of highly confined tokamak plasmas. Ensuring that PF coil current and mechanical stress stay within superconducting and structural limitations is an important check in the design assessment. Minimizing the PF coil currents and mechanical stresses influences reliability, cost, and performance. A free-boundary MHD equilibrium code—FreeGS is employed within the fusion reactor design and assessment (FREDA) whole facility modeling (WFM) framework to construct the plasma equilibrium based on the configuration and currents in the PF coils. Here, we present the capability of the FreeGS code to minimize the currents, forces, and electromagnetic stresses on the PF coils by optimizing their number, sizes, structures, and locations while maintaining an MHD stable plasma configuration with a large confinement factor. The workflow is initialized with a configuration of plasma parameters and coils’ locations from the 0-D tokamak build systems code in the FREDA framework. Then, FreeGS is called to calculate the initial equilibrium at the minimum total current in PF coils. Thereafter, FreeGS’s internal optimizer minimizes the currents and hoop and central forces on the PF coils while maintaining the reference equilibrium. Finally, the input configuration is updated with the optimized parameters for equilibria over the ramp-up phase of a burning-plasma operation. FREDA’s whole facility optimization capability, which includes all magnetic field coil systems, blanket, vacuum vessel (VV), first wall, divertor, etc., is under development and out of the scope for this study.

Hassan, Ehab [ORNL] (ORCID:0000000181060301)↗

Applications of explainable artificial intelligence in renewable energy research

Researchers in renewable energy are applying deep learning (DL) to a variety of problems from diverse renewable energy domains, such as biofuels, wind, solar, power systems, buildings, vehicles, and transportation systems. Improvements in accuracy may be demonstrated using DL in laboratory settings. However, the lack of interpretability of DL models poses a practical limitation to their utility in advancing scientific knowledge and in the deployment of DL models in safety-critical energy systems. In this article, we discuss explainable artificial intelligence (XAI) as one pathway toward more interpretable DL models. We explore a brief timeline of U.S. national laboratory interest in XAI, an overview and taxonomy of methods in the field of XAI, and a selection of applications across renewable energy research domains. We conclude by highlighting pivotal areas where XAI can accelerate innovation in artificial intelligence for renewable energy research and other essential future directions.

97 MATHEMATICS AND COMPUTING↗

IEA EBC annex 53: Total energy use in buildings—Analysis and evaluation methods

One of the most significant barriers to achieving deep building energy efficiency is a lack of knowledge about the factors determining energy use. In fact, there is often a significant discrepancy between designed and real energy use in buildings, which is poorly understood but are believed to have more to do with the role of human behavior than building design. Building energy use is mainly influenced by six factors: climate, building envelope, building services and energy systems, building operation and maintenance, occupants’ activities and behavior, and indoor environmental quality. In the past, much research focused on the first three factors. However, the next three human-related factors can have an influence as significant as the first three. Annex 53 employed an interdisciplinary approach, integrating building science, architectural engineering, computer modeling and simulation, and social and behavioral science to develop and apply methods to analyze and evaluate the real energy use in buildings considering the six influencing factors. Finally, outcomes from Annex 53 improved understanding and strengthen knowledge regarding the robust prediction of total energy use in buildings, enabling reliable quantitative assessment of energy-savings measures, policies, and techniques.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗