Measurement of Carbon Dioxide Column via Space Borne Laser Absorption

In order to better understand the budget of carbon dioxide in the Earth's atmosphere it is necessary to develop a global high precision understanding of the carbon dioxide column. In order to uncover the 'missing sink that is responsible for the large discrepancies in the budget as we presently understand it calculation has indicated that measurement accuracy on the order of 1 ppm is necessary. Because typical column average CO2 has now reached 380 ppm this represents a precision on the order of .25% for these column measurements. No species has ever been measured from space at such a precision. In recognition of the importance of understanding the CO2 budget in order to evaluate its impact on global warming the National Research Council in its decadal survey report to NASA recommended planning for a laser based total CO2 mapping mission in the near future. The extreme measurement accuracy requirements on this mission places very strong requirements on the laser system used for the measurement. This work presents an analysis of the characteristics necessary in a laser system used to make this measurement. Consideration is given to the temperature dependence, pressure broadening, and pressure shift of the CO2 lines themselves and how these impact the laser system characteristics Several systems for meeting these requirements that are under investigation at various institutions in the US as well as Europe will be discussed.

Heaps, WIlliam S.↗

Progress on Passive Sensor for Ultra-Precise Measurement of Carbon Dioxide from Space

Global measurements of atmospheric carbon dioxides (CO2) are needed to resolve significant discrepancies that exist in our understanding of the global carbon budget and, therefore, man's role in global climate change. The science measurement requirements for CO2 are extremely demanding (precision c .3%) No atmospheric chemical species has ever been measured from space with this precision. We are developing a novel application of a Fabry-Perot interferometer to detect spectral absorption of reflected sunlight by CO2 and O2 in the atmosphere. Preliminary design studies indicate that the method will be able to achieve the sensitivity and signal-to-noise required to measure column CO2 at the target specification. We are presently engaged in the construction of a prototype instrument for deployment on an aircraft to test the instrument performance and our ability to retrieve the data in the real atmosphere. In the first 6 months we have assembled a laboratory bench system to begin testing the optical and electronic components. We are also undertaking some measurements of signal and noise levels for actual sunlight reflecting from the ground. We shall present results from some of these ground based studies and discuss their implications for a space based system.

Heaps, William S.↗

Carbon dioxide hydrate and floods on Mars

Ground ice on Mars probably consists largely of carbon dioxide hydrate. This hydrate dissociates upon release of pressure at temperatures between 0 and 10 C. The heat capacity of the ground would be sufficient to produce up to 4% (by volume) of water at a rate equal to that at which it can be drained away. Catastrophic dissociation of carbon dioxide hydrate during some past epoch when the near-surface temperature was in this range would have produced chaotic terrain and flood channels.

Milton, D. J.↗

The effect of increased carbon dioxide concentrations on stratospheric ozone

Consideration is given to the influence on ozone of an increased carbon dioxide concentration, for which a measurable growth has been observed in the recent past. Increased carbon dioxide can indirectly affect ozone by perturbing atmospheric temperatures, which will alter ozone production, whose rate displays a fairly strong temperature dependence. This paper presents one-dimensional model results for the steady state ozone behavior when the CO2 concentration is twice its ambient level; the results account for coupling between chemistry and temperature. When the CO2 level doubled, the total ozone burden increased in relation to the ambient burden by 1.2-2.5%, depending on the vertical diffusion coefficient used. Above 30 km, ozone concentrations were larger than the ambient values, a maximum increase of 16% being reached at 43 km. In this region the relative variations were insensitive to the choice of diffusion coefficient. Below 30 km, ozone concentrations were smaller than the unperturbed values and were sensitive to the vertical diffusion profile in this region (10-30 km).

Boughner, R. E.↗

Theoretical constraints on oxygen and carbon dioxide concentrations in the Precambrian atmosphere

Simple (one-dimensional) climate models suggest that carbon dioxide concentrations during the Archean must have been at least 100-1000 times the present level to keep the Earth's surface temperature above freezing in the face of decreased solar luminosity. Such models provide only lower bounds on CO2, so it is possible that CO2 levels were substantially higher than this and that the Archean climate was much warmer than today. Periods of extensive glaciation during the early and late Proterozoic, on the other hand, indicate that the climate at these times was relatively cool. To be consistent with climate models CO2 partial pressures must have declined from approximately 0.03 to 0.3 bar around 2.5 Ga ago to between 10(-3) and 10(-2) bar at 0.8 Ga ago. This steep decrease in carbon dioxide concentrations may be inconsistent with paleosol data, which implies that pCO2 did not change appreciably during that time. Oxygen was essentially absent from the Earth's atmosphere and oceans prior to the emergence of a photosynthetic source, probably during the late Archean. During the early Proterozoic the atmosphere and surface ocean were apparently oxidizing, while the deep ocean remained reducing. An upper limit of 6 x 10(-3) bar for pO2 at this time can be derived by balancing the burial rate of organic carbon with the rate of oxidation of ferrous iron in the deep ocean. The establishment of oxidizing conditions in the deep ocean, marked by the disappearance of banded iron formations approximately 1.7 Ga ago, permitted atmospheric oxygen to climb to its present level. O2 concentrations may have remained substantially lower than today, however, until well into the Phanerozoic.

Review, Tutorial↗

Precise Measurement of Carbon Dioxide Column by Passive Ground Based Sensor

Over the past four years we have developed a family of differential radiometers based upon the Fabry-Perot interferometers that exhibit very great sensitivity to changes in the atmospheric column of carbon dioxide, oxygen, and water vapor. Our instruments employ a solid Fabry-Perot etalon that is tuned to the proper wavelength by changing its temperature. The thickness of the etalon has been selected so that its multiple pass bands align with regularly space absorption features of the molecule under investigation. Using multiple absorption features improves the optical throughput of the instrument and improves the stability of the instrument response with respect to environmental changes. We are presently working to extend this technique to the carbon 13 isotope of carbon dioxide and to methane. Our instruments are intrinsically rugged and can be fabricated in a small package at relatively low cost.. As such they hold promise for widespread use in ground based networks for calibration and validation of satellite instruments such as OCO and GOSAT. Results will be presented for long term ground based operations of these systems. The effects of atmospheric scattering, pointing errors, pressure broadening and temperature effects will be discussed with regard to achieving precision better than .5% required for validation of carbon dioxide column measured from space. Finally we will outline the approach for extension of this methodology to additional molecular species of interest.

Heaps, William S.↗

Carbon dioxide concentrator

Passed exhaled air through electrochemical cell containing alkali metal carbonate aqueous solution, and utilizes platinized electrodes causing reaction of oxygen at cathode with water in electrolyte, producing hydroxyl ions which react with carbon dioxide to form carbonate ions.

Williams, C. F.↗

Radiative decay in carbon dioxide.

Thermal disturbance radiative decay time in carbon dioxide at low pressures and for nonzero vibrational relaxation times

Hodges, R. R., Jr.↗