Search NASA⌕ Search

SEARCH · Search NASA

Results for “CARRIER MODULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Decentralized Interleaving of Parallel-Connected Buck Converters

We present a decentralized control strategy that yields switch interleaving for parallel-connected dc-dc buck converters. Compared to state-of-the-art methods that are distributed at best, the proposed architecture requires no communication, and hence, presents a variety of advantages with regard to reliability, modularity, and cost. The method is based on the digital implementation of the dynamics of a Lienard-type oscillator circuit as the controller for the converters. Each controller only requires the locally measured output current to synthesize the pulsewidth modulation (PWM) carrier waveform. The intrinsic electrical coupling between converters drives the nonlinear-oscillator-based controllers to converge to an interleaved state with uniform phase spacing across PWM carriers, independent of the number of converters, the load, and initial conditions. We provide analytical guarantees for existence and stability of the interleaved state as well as extensive hardware results for a system of five 120 W 48 V-to-12 V dc-dc buck converters that demonstrate convergence to the interleaved state in the face of a variety of large-signal disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Band Structure-Driven Design of a α-CsPbI 3 Ammonia Sensor for Industrial Applications

We investigate the defect-dependent electronic structure and gas-sensing potential of cubic α-CsPbI 3 using first-principles density functional theory and nonadiabatic molecular dynamics. Among the intrinsic defects, interstitials, vacancies, antisites, and switches studied, the I Pb and Pb I antisite defects exhibit transition energy levels near the middle of the band gap, thus functioning as deep traps. Short-term adsorption of ammonia selectively modifies the electronic structure, coordinating with Pb at Pb I sites and Cs at I Pb sites, significantly altering recombination pathways. Detailed analysis reveals that NH 3 reduces anharmonicity at I Pb defects, enabling enhanced recombination at elevated temperatures, while trap-assisted recombination dominates at room temperature. Other analytes, including CH 3 NH 2 and NO 2 , show negligible impact on the band gap or recombination dynamics, highlighting the potential selectivity of NH 3 interactions. Ab initio nonadiabatic molecular dynamics simulations at 300 K and 600 K further demonstrate temperature-dependent modulation of carrier lifetimes, with NH 3 accelerating recombination at ambient conditions and suppressing certain pathways at higher temperatures. These findings suggest that α-CsPbI 3 can serve as a selective and sensitive ammonia sensor over a broad temperature range and offer insights for ammonia detection under industrially relevant conditions.

ammonia sensor↗

Improved S/N meter

Signal-to-noise ratios /S/N/ meter containing a variable-frequency notch filter measures noise plus interference in the presence of carrier or modulation signals. A noise source and calibration signal source are included in the instrument for calibration purposes.

Windett, C. B.↗

Facsimile video enhancement device

Video remodulation unit enhances facsimile transmission using an amplitude-modulated 2400 Hz carrier. The unit demodulates the signal and then remodulates it, using the same carrier. By using the unit controls, modulation can be set to levels that compensate for picture in-transit degradation.

Vermillion, C. H.↗

EEG monitoring of a free-swimming diver at a working depth of 15 meters.

Feasibility has been shown for underwater transmission of physiological signals, using frequency modulation of carriers transmitted by return-current-density methods, as part of a personal biotelemetry system. In the prototype system, a standard IRIG subcarrier frequency (2300 Hz) was used. Power requirements, antenna design, and signal attenuation are compatible with free-ranging diving activity at distances up to 15 meters from the receiver. Extrapolation from this study and further developments are expected to substantially increase the range. Advantages of this system include subcarrier compatibility with standard IRIG demodulators using channels 1 through 10, the absence of highly specialized antenna requirements, and reasonable attenuation characteristics for transmission through the turbidity of typical seawater. Moreover, the system would not appear to be depth limited, and to be compatible with use of high-powered transponders of the same type for long-distance transmission, with or without further encoding.

Zweizig, J. R.↗

Multichannel telemetry system

A two-channel telemetry system is described in which one channel is used for high-rate data and the other channel for low-rate data communication. In the transmitter a signal, which subsequently phase modulates a carrier, is produced which is a function of at least the high-rate data, the low-rate data and the frequency of the subcarrier of the low-rate channel. In the receiver which includes a phase-locked loop, the high-rate data is detected off the receiver inphase channel output and the low-rate off the quadrature channel output.

Butman, S.↗

Bi-directional four quadrant (BDQ4) power converter development

The feasibility for implementation of a concept for direct ac/dc multikilowatt power conversion with bidirectional transfer of energy was investigated. A 10 kHz current carrier was derived directly from a common 60 Hz three phase power system. This carrier was modulated to remove the 360 Hz ripple, inherent in the three phase power supply and then demodulated and processed by a high frequency filter. The resulting dc power was then supplied to a load. The process was implemented without the use of low frequency transformers and filters. This power conversion processes was reversible and can operate in the four quadrants as viewed from any of the two of the converter's ports. Areas of application include: power systems on air and spacecraft; terrestrial traction; integration of solar and wind powered systems with utility networks; HVDC; asynchronous coupling of polyphase networks; heat treatment; industrial machine drives; and power supplies for any use including instrumentation.

Schwarz, F. C.↗

Pulsed Phase Shifter Improves Doppler Radar

Ability of microwave Doppler radar to measure velocity of slow moving nearby target is enhanced by pulsed 90 degrees phase shifter in radar transmission line between circulator and antenna. Because of phase shifting, Doppler frequency is detected as modulation on carrier instead of baseband signal. Carrier is amplified and filtered before demodulation, resulting in strong, clean demodulated Doppler for measurement and display.

Kobayashi, H. S.↗

Development and fabrication of a solar cell junction processing system

Modifications to the ground plane, to insure a good electrical return path during the pulse discharge, were made using a ring of beryllium copper finger stock attached to the underside of the aluminum ground plate. Experiments on annealing of wafers with ion implantation damage continued. The entire surface of 100 mm diameter wafers were annealed by one pulse for the standard implant (10 keV, phosphorus, 2x10 to the 15th power ions/sq cm). While samples are being fabricated into solar cells for electrical characterization, work is continuing on improvement of the electron beam uniformity and the optimization of the diode parameters. The engineering design was completed and the manufacturing detail drawings were released for fabrication. Assembly of the subcomponents for the exit and entrance locks is almost complete. These components include the cassettes, the indexing mechanisms, main doors, and wafer carrier transfer modules. The 'Y' track and three phase transition track sections are under final assembly and test.

Giesling, R.↗

60-GHz integrated-circuit high data rate quadriphase shift keying exciter and modulator

An integrated-circuit quadriphase shift keying (QPSK) exciter and modulator have demonstrated excellent performance directly modulating a carrier frequency of 60 GHz with an output phase error of less than 3 degrees and maximum amplitude error of 0.5 dB. The circuit consists of a 60-GHz Gunn VCO phase-locked to a low-frequency reference source, a 4th subharmonic mixer, and a QPSK modlator packaged into a small volume of 1.8 x 2.5 x 0.35 in. The use of microstrip has the advantages of small size, light-weight, and low-cost fabrication. The unit has the potential for multigigabit data rate applications.

Grote, A.↗

Behavior Of Costas Loop In Reception Of Telemetry

Report presents theoretical study of behavior of Costas loop in reception of radio carrier signal modulated in phase by sinusoidal or square-wave subcarrier, further modulated in phase by nonreturn-to-zero binary data signal. Phase and frequency of received signal affected by Doppler shift, and instantaneous amplitude of received signal corrupted by additive white Gaussian noise. Signals of this type ordinarily used in spacecraft telemetry, sine-wave subcarrier being preferred for shorter signal paths and square-wave subcarrier for longer signal paths.

Nguyen, Tien M.↗

Behavior Of Costas Loop In Reception Of Telemetry

Report presents study of behavior of Costas loop in reception of binary non-return-to-zero telemetry signal phase-shift-modulated onto sinusoidal or square-wave subcarrier signal in turn phase-modulated onto carrier signal. Equations describe degradation of performance of Costas loop in terms of phase jitter, conditions causing loss of lock, and other effects. Costas loop used to track telemetry signal with residual carrier in presence of Doppler shift. Performance optimized by suitable choice of bit rate, waveform and frequency of subcarrier, and noise bandwidth of filters in arms of Costas loop.

Nguyen, Tien Manh↗

Optimum Detection Of Slow-Frequency-Hopping Signals

Two papers present theoretical analyses of various schemes for coherent and noncoherent detection of M-ary-frequency-shift-keyed (MFSK) signals with slow frequency hopping. Special attention focused on continuous-phase-modulation (CPM) subset of SFH/MFSK signals, for which frequency modulation such carrier phase remains continuous (albeit unknown) during each hop.

Levitt, Barry K.↗

Integrated Cryogenic Satellite Communications Cross-Link Receiver Experiment

An experiment has been devised which will validate, in space, a miniature, high-performance receiver. The receiver blends three complementary technologies; high temperature superconductivity (HTS), pseudomorphic high electron mobility transistor (PHEMT) monolithic microwave integrated circuits (MMIC), and a miniature pulse tube cryogenic cooler. Specifically, an HTS band pass filter, InP MMIC low noise amplifier, HTS-sapphire resonator stabilized local oscillator (LO), and a miniature pulse tube cooler will be integrated into a complete 20 GHz receiver downconverter. This cooled downconverter will be interfaced with customized signal processing electronics and integrated onto the space shuttle's 'HitchHiker' carrier. A pseudorandom data sequence will be transmitted to the receiver, which is in low Earth orbit (LEO), via the Advanced Communication Technology Satellite (ACTS) on a 20 GHz carrier. The modulation format is QPSK and the data rate is 2.048 Mbps. The bit error rate (BER) will be measured in situ. The receiver is also equipped with a radiometer mode so that experiment success is not totally contingent upon the BER measurement. In this mode, the receiver uses the Earth and deep space as a hot and cold calibration source, respectively. The experiment closely simulates an actual cross-link scenario. Since the receiver performance depends on channel conditions, its true characteristics would be masked in a terrestrial measurement by atmospheric absorption and background radiation. Furthermore, the receiver's performance depends on its physical temperature, which is a sensitive function of platform environment, thermal design, and cryocooler performance. This empirical data is important for building confidence in the technology.

Romanofsky, R. R.↗