Search NASA⌕ Search

SEARCH · Search NASA

Results for “CIRCULAR TUBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Subcooled freon-11 flow boiling in top-heated finned coolant channels with and without a twisted tape

An experimental study was conducted in top-heated finned horizontal tubes to study the effect of enhancement devices on flow boiling heat transfer in coolant channels. The objectives are to examine the variations in both the mean and local (axial and circumferential) heat transfer coefficients for circular coolant channels with spiral finned walls and/or spiral fins with a twisted tape, and improve the data reduction technique of a previous investigator. The working fluid is freon-11 with an inlet temperature of 22.2 C (approximately 21 C subcooling). The coolant channel's exit pressure and mass velocity are 0.19 M Pa (absolute) and 0.21 Mg/sq. ms, respectively. Two tube configurations were examined; i.e., tubes had either 6.52 (small pitch) or 4.0 (large pitch) fins/cm of the circumferential length (26 and 16 fins, respectively). The large pitch fins were also examined with a twisted tape insert. The inside nominal diameter of the copper channels at the root of the fins was 1.0 cm. The results show that by adding enhancement devices, boiling occurs almost simultaneously at all axial locations. The case of spiral fins with large pitch resulted in larger mean (circumferentially averaged) heat transfer coefficients, h sub m, at all axial locations. Finally, when twisted tape is added to the tube with large-pitched fins, the power required for the onset of boiling is reduced at all axial and circumferential locations.

Smith, Alvin↗

Microscopic tubes in igneous rocks

Microscopic tubes have been observed in several igneous rocks and may be quite common. They occur in single crystals and have either elliptical or circular cross-sections 1 to 5 microns in diameter and are ten to hundreds of microns long. Microtubes may be hollow or partially or completely filled with another phase, but are distinct from acicular crystals of accessory minerals such as rutile. Microtubes can form by at least three processes: (1) the partial annealing of microcracks, (2) the natural etching of dislocations, or (3) the primary inclusion of fluid material during crystal growth.

Richter, D.↗

A magnetic suspension system with a large angular range

The paper describes a small-scale laboratory system, called the Large-Angle Magnetic Suspension Test Fixture (LAMSTF), constructed at NASA Langley Research Center in order to explore and develop technology required for the magnetic suspension of objects over large ranges of orientation. The LAMSTF hardware comprises five electromagnets in a circular arrangement, each driven from a separate bipolar power amplifier. The suspended element is a cylindrical axially magnetized permanent magnet core, within an aluminum tube. The element, which is 'levitated' by repulsive forces, is stabilized in five degrees-of-freedom, with rotation about the cylinder axis not controlled. The controller accommodates the changes in magnetic coupling between the electromagnets and the suspended element by real-time adaptation of a decoupling matrix. The paper presents performance measurements demonstrating that the major design objective of the 360 deg rotation was accomplished.

Britcher, Colin P.↗

Integrated structure vacuum tube: A Concept

Cathode emission is made to occur by heating entire structure to 600 C, and positive potential is applied to anode with negative potential on grids. Electron flow takes place from ring to circular anode through electric field produced by grids.

Dimeff, J.↗

The UCR gamma ray telescope data acquisition system

A description is given of an electronics system based on the DEC Falcon SBC-11/23+, which has been designed and built to support a balloon-borne double Compton gamma-ray telescope. The system provides support for commands, data acquisition, data routing and compression, and photomultiplier tube gain control. The software consists of a number of interrupt-driven routines of differing priorities to handle each system task. This includes two circular buffers for onboard processing and bit encoding before transmission of the information to the ground computer. Acquisition of gamma-ray events at rates above the 200-Hz telemetry constraint is easily achieved.

O'Neill, T. J.↗

Invariant Manifolds, the Spatial Three-Body Problem and Space Mission Design

The invariant manifold structures of the collinear libration points for the spatial restricted three-body problem provide the framework for understanding complex dynamical phenomena from a geometric point of view. In particular, the stable and unstable invariant manifold 'tubes' associated to libration point orbits are the phase space structures that provide a conduit for orbits between primary bodies for separate three-body systems. These invariant manifold tubes can be used to construct new spacecraft trajectories, such as 'Petit Grand Tour' of the moons of Jupiter. Previous work focused on the planar circular restricted three-body problem. The current work extends the results to the spatial case.

three body problem↗

Thermal conduction in a composite circular cylinder: A new technique for thermal conductivity measurements of lunar core samples

The core sample is heated from the outside at a known rate and the rise in temperature at the surface of the core tube is measured. Because the temperature at the surface, increasing with time, is a function of the thermal properties of both the core tube and the sample, the thermal properties of the sample can be estimated by comparing the measured temperature with the theory, provided that the thermal properties of the core tube are known. Thus it is not necessary to extract the sample from the core tube to make the measurements. Neither is it necessary to insert a heater, or temperature sensor, into the sample within the core tube, as would be required if another method were applied. The sample remains intact after the measurements. The temperature change in the sample can be kept to a minimum as long as the thermal conductivity determination is possible with a reasonable precision. If the radiative method of heat transfer is chosen, the core tube will only be in mechanical contact with the sample holder and a sensor attached to the core tube to measure the surface temperature, thereby greatly reducing the possibility of disturbing the sample.

Horai, K.↗

Kinetic-ballooning-mode turbulence in low-average-magnetic-shear equilibria

In this work, kinetic-ballooning-mode (KBM) turbulence is studied via gyrokinetic flux-tube simulations in three magnetic equilibria that exhibit small average magnetic shear: the Helically Symmetric eXperiment (HSX), the helical-axis Heliotron-J and a circular tokamak geometry. For HSX, the onset of KBM being the dominant instability at low wavenumber occurs at a critical value of normalized plasma pressure $\beta ^{\rm KBM}_{\rm crit}$ that is an order of magnitude smaller than the magnetohydrodynamic (MHD) ballooning limit $\beta ^{\rm MHD}_{\rm crit}$ when a strong ion temperature gradient (ITG) is present. However, $\beta ^{\rm KBM}_{\rm crit}$ increases and approaches the MHD ballooning limit as the ITG tends to zero. For these configurations, $\beta ^{\rm KBM}_{\rm crit}$ also increases as the magnitude of the average magnetic shear increases, regardless of the sign of the normalized magnetic shear. Simulations of Heliotron-J and a circular axisymmetric geometry display behaviour similar to HSX with respect to $\beta ^{\rm KBM}_{\rm crit}$ . Despite large KBM growth rates at long wavelengths in HSX, saturation of KBM turbulence with $\beta > \beta _{\rm crit}^{\rm KBM}$ is achievable in HSX and results in lower heat transport relative to the electrostatic limit by a factor of roughly five. Nonlinear simulations also show that KBM transport dominates the dynamics when KBMs are destabilized linearly, even if KBM growth rates are subdominant to ITG growth rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A true-field magnetogram in a solar plage region

The Near-Infrared Magnetograph is used to make the first 2D image of true magnetic field strength in the solar photosphere. The magnitude of the magnetic field vector is derived with a typical formal precision of + or - 75 G (2 sigma) from circularly polarized spectra of a highly Zeeman-sensitive iron line at 6388.6/cm. The true-field map demonstrates that the properties of 'kilogauss' flux tubes vary coherently on a variety of spatial scales within the 1-arcmin field of view. The measured fields span the range 1000-1700 G. The amplitude of the polarized signal implies that the spatial filling factor of the flux tubes can approach 0.3 at the seeing-limited resolution of 2 arcsec. Magnetic field strength and magnetic flux are statistically related in the sense that weak-field areas are weak-flux areas, but strong fields are present in both strong-flux and weak-flux areas. This implies a degree of independence in the relationship between the filling factor of flux tubes and their individual properties, such as field strength, pressure, and temperature.

Rabin, Douglas↗

Standards for discharge measurement with standardized nozzles and orifices

The following standards give the standardized forms for two throttling devices, standard nozzles and standard orifices, and enable them to be used in circular pipes without calibration. The definition of the standards are applicable in principle to the calibration and use of nonstandardized throttling devices, such as the venturi tube. The standards are valid, likewise, as a basis for discharge measurements in the German acceptance standards.

Source record↗

Development of the PRSEUS Multi-Bay Pressure Box for a Hybrid Wing Body Vehicle

NASA has created the Environmentally Responsible Aviation Project to explore and document the feasibility, benefits, and technical risk of advanced vehicle configurations and enabling technologies that will reduce the impact of aviation on the environment. A critical aspect of this pursuit is the development of a lighter, more robust airframe that will enable the introduction of unconventional aircraft configurations that have higher lift-to-drag ratios, reduced drag, and lower community noise. Although such novel configurations like the Hybrid Wing Body (HWB) offer better aerodynamic performance as compared to traditional tube-and-wing aircraft, their blended wing shapes also pose significant new design challenges. Developing an improved structural concept that is capable of meeting the structural weight fraction allocated for these non-circular pressurized cabins is the primary obstacle in implementing large lifting-body designs. To address this challenge, researchers at NASA and The Boeing Company are working together to advance new structural concepts like the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS), which is an integrally stiffened panel design that is stitched together and designed to maintain residual load-carrying capabilities under a variety of damage scenarios. The large-scale multi-bay fuselage test article described in this paper is the final specimen in a building-block test program that was conceived to demonstrate the feasibility of meeting the structural weight goals established for the HWB pressure cabin.

Jegley, Dawn C.↗

Joule-heating power dissipation in a type-II superconductor tube.

The theoretical analysis of the Joule-heating power density in a specific hollow cylinder of a NbZr superconductor is presented. It is seen that the power density, which is the primary source of internal heating neglecting localized annihilation heating, can have a very complicated behavior, especially in the circular region. Rough estimates of the relative temperature changes are made, and the locations at which instabilities are more likely to initiate are considered.

Urban, E. W.↗

Development of a high current density, high temperature superconducting cable for pulsed magnets

Abstract A low AC loss Rare Earth Barium Copper Oxide (REBCO) cable, based on the VIPER cable technology has been developed by Commonwealth Fusion Systems for use in high field, REBCO based tokamaks. The new cable is composed of partitioned and transposed copper ‘petals’ shaped to fit together in a circular pattern with each petal containing a REBCO tape stack and insulated from each other to reduce AC losses. A stainless steel jacket adds mechanical robustness—also serving as a vessel for solder impregnation—while a tube runs through the middle for cooling purposes. Additionally, fiber optic sensors are placed under the tape stacks for quench detection. To qualify this design, a series of experiments were conducted as part of the SPARC tokamak Central Solenoid Model Coil program—to retire the risks associated with full scale, fast ramping, high flux HTS Central Solenoid (CS) and Poloidal Field (PF) coils for tokamak fusion power plants and net energy demonstrators. These risk study and risk reduction experiments include (1) AC loss measurement and model validation in the range of ~5 T/s, (2) an IxB electromagnetic loading of over 850 kN/m at the cable level and up to 300 kN/m at the stack level, (3) a transverse compression resilience of over 350 MPa, (4) manufacturability at tokamak relevant speeds and scales, (5) cable to cable joint performance, (6) fiber optic based quench detection speed, accuracy, and feasibility, and (7) overall winding pack integration and magnet assembly. The result is a cable technology, now referred to as PIT VIPER, with AC losses that measure fifteen times lower (at ~5 T/s) than its predecessor technology; a 2% or lower degradation of critical current (Ic) at high IxB electromagnetic loads; no detectable Ic degradation up to 570 MPa of transverse compression on the cable unit cell; end to end magnet manufacturing, consistently producing Ic values within 7% of the model prediction; cable to cable joint resistances at 20 K on the order of ~15 nΩ; and fast, functional quench detection capabilities that do not involve voltage taps. This cable technology will be tested comprehensively in a Central Solenoid Model Coil to prove its readiness for compact, high field tokamak operation.

Sanabria, Charlie (ORCID:0000000150175309)↗

Unsteady loads due to propulsive lift configurations. Part C: Development of experimental techniques for investigation of unsteady pressures behind a cold model jet

As part of an overall study of the scaling laws for the fluctuating pressures induced on the wings and flaps of STOL aircraft by jet engine impingement, an experimental investigation was made of the near field fluctuating pressures behind a cold circular jet, both when it was free and when it was impinging on a flat plate. Miniature static pressure probes were developed for measurements in the free jet and on the flat plate which were connected by plastic tubing to 1/8 inch microphones and acted as pressure transducers. Using a digital correlator together with an FFT program on the CDC 6400 computer, spectral densities, relative amplitudes, phase lags, and coherences were also obtained for the signals from pairs of these probes, and were used to calibrate these probes directly against microphones. This system of instrumentation was employed to obtain single point rms and third octave surveys of the static pressures in the free jet and on the surface of the plate.

Haviland, J. K.↗

All-Optical Micro Motors Based on Moving Gratings in Photosensitive Media

An all-optical micro motor with a rotor driven by a traveling wave of surface deformation of a stator being in contact with the rotor is being studied. Instead of an ultrasonic wave produced by an electrically driven piezoelectric actuator as in ultrasonic motors, the wave is a result of a photo induced surface deformation of a photosensitive material produced by a traveling holographic grating. Two phase modulated coherent optical beams generate the grating. Several types of photosensitive materials are studied such as photorefractive crystals, photosensitive piezoelectric ceramics, and side-chain liquid crystalline polyesters. In order to be considered as a possible candidate for micro motors, the material should exhibit surface deformation produced by moving grating of the order of 10 micron. Deformations produced by static holographic gratings are studied in photorefractive crystals of LiNbO3 using high vertical resolution surface profilometer Dektak 3 and surface interferometer WYKO. An experimental set-up with moving grating has been developed. The set-up uses a two-beam interferometry configuration with one beam being reflected by a thin mirror mounted on a loud speaker. A ramp voltage signal generator drives the speaker. Changing voltage, polarity, and frequency of the signal can easily generate vibrating gratings or moving gratings in both directions. A vibrating grating has been applied to a photorefractive crystal of BSO controlled by an external electric field of the order of 104 V/cm. We have additionally studied effects of moving grating interaction with light absorbing fluids such as solutions of 2,9,16,23-Tetrakis(phenylthio)-29H, 31 Hphthalocyanine in chlorobenzene in capillary tubes. The purpose of using a liquid is to show that the moving gratings can force a liquid to shift. The interaction of a single low power focused laser beam at 633 nm with such fluid produced an intensive circular motion, which also might be applied to all-optical micro motors or actuators.

Curley, M.↗

All-Optical Micro Motors Based on Moving Gratings in Photosensitive Media

An all-optical micromotor with a rotor driven by a traveling wave of surface deformation of a stator being in contact with the rotor is being studied. Instead of an ultrasonic wave produced by an electrically driven piezoelectric actuator as in ultrasonic motors, the wave is a result of a photo-induced surface deformation of a photosensitive material produced by an incident radiation. A thin piezoelectric polymer will deform more easily LiNbO3 or metal when irradiated with light. The type of photosensitive material studied are piezoelectric polymers with and without coatings for connecting electrodes. In order to be considered as a possible candidate for micromotors, the material should exhibit surface deformation produced by a laser beam of the order of 10 microns. This is compared to the deformations produced by static holographic gratings studied in photorefractive crystals of LiNbO3 using high vertical resolution surface profilometer Dektak 3 and surface interferometer WYKO. An experimental setup showing the oscillations has been developed. The setup uses a chopped beam from an Argon ion laser to produce the deformation while a probe beam is reflected by the thin film into a fiber which is then detected on an oscilloscope. A ramp voltage signal generator will drive the piezoelectric film in another experiment to determine the resonance of the film. A current is generated when light is incident upon the film and this current can be measured. The reverse process has already been demonstrated in other piezoelectric actuators. Changing voltage, polarity, and frequency of the signal can easily generate vibrations similar to those when light is incident on the film. This can be compared to the effects of laser interaction with light absorbing fluids such as solutions of 2,9,16,23-Tetrakis(phenylthio)-29H, 31 H-phthalocyanine in chlorobenzene in capillary tubes, The possibility of using a liquid with the piezoelectric film would be a novel idea for a micromotor since the interaction of a single low power focused laser beam at 633 nm with such fluid produced an intensive circular motion.

Curley, M.↗