Search NASA⌕ Search

SEARCH · Search NASA

Results for “CO2 Storage Costs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

CO 2 to Fuels Through Novel Electrochemical Catalysis (Final Report)

Electrochemical upgrading of CO 2 into hydrocarbon fuels via CO 2 –H 2 O co-electrolysis using solid oxide electrolysis cells (SOECs) presents an encouraging approach to cost-effective storage of renewable power. In this study, we harness the unique property of protonic ceramic electrolysis cells (PCEC) and demonstrate direct electro-catalytic production of CH 4 from CO 2 –H 2 O in a unit-cell stack configuration. The unit-cell stack was developed to evaluate the scalability and the applicability of PCECs from a broader system-level viewpoint. Tradeoffs between operating conditions and performance metrics were explored and thoroughly characterized. An exceptional CH 4 -yield ratio of 34.6% from only CO 2 –H 2 O reactants was achieved under an electrolysis current of 1 A cm –2 at 450 °C. With exhaust-H 2 recycle, this value was boosted to greater than 70%. In addition, the electrochemical co-conversion of CO 2 –H 2 O offers a higher CH 4 -yield ratio compared to traditional thermo-catalytic conversion of CO 2 –H 2 under certain operating conditions, indicating possible electrochemical promotion of catalytic CO 2 methanation. The demonstrated good performance is a promising result for further scale-up and for the practical utilization of electrochemical CO 2 upgrade using PCECs. Techno-economic analyses reveal operating conditions that yield cost-competitive levelized cost of fuel production.

01 COAL, LIGNITE, AND PEAT↗

Hydraulic fracturing to enhance injectivity and storage capacity of CO 2 storage reservoirs: Benefits and risks

Several potential CO 2 storage reservoirs have been found to have insufficient porosity and permeability to support cost effective commercial-scale injection. As a result, the use of hydraulic fracturing to enhance injectivity and storage capacity of CO 2 storage reservoirs was explored. Previous modeling studies indicate that fracturing can increase storage capacity by modest to significant amounts (10%–35%), depending on model assumptions. Simulations completed as part of this study confirm that for a range of horizontal well lengths, number of fractures, fracture geometries, and fracture properties, injectivity is improved and capacity increases by 13%–71% over the base case unfractured vertical well. Intuitively, increasing the well length and number of fractures had a corresponding impact on increased capacity. Here, fracture area (i.e., the fracture height multiplied by its width) was an important parameter for increasing capacity but the specific geometry (e.g., the ratio of height-to-width) was unimportant. The most important aspect that affected capacity was the ability of a fracture to connect high permeability horizontal zones in the reservoir. This would allow a single well to access both layers, thereby maximizing total storage capacity of the reservoir while likely leading to an overall increase of the CO 2 footprint, which is an important consideration for Class VI UIC permitting. The results of this work demonstrate that hydraulic fracturing is an attractive option to consider when faced with an underperforming geologic carbon storage site that is at risk of causing a project to fail.

03 NATURAL GAS↗

Carbon management technology pathways for reaching a U.S. Economy-Wide net-Zero emissions goal

The Carbon Management Study Group of the 37 th Energy Modeling Forum (EMF 37) designed seven scenarios to explore the role of three potentially key technology suites – point source carbon dioxide capture and storage (PSCCS), direct air capture of carbon dioxide (DACCS), and hydrogen systems (H 2 ) – in shaping the broader technology pathways to reaching net-zero carbon dioxide (CO 2 ) emissions in United States by 2050. Each scenario was run by up to 13 models participating in the EMF 37 study. Results show that carbon dioxide removal technologies were consistently a major part of successful pathways to net-zero U.S. CO 2 emissions in 2050. Achieving this net-zero CO 2 goal without any form of carbon dioxide capture and storage was found to be impossible for most models; some models also found it impossible to reach net-zero without DACCS. The marginal cost of achieving net-zero CO 2 emissions in 2050 was between two and 10 times higher without PSCCS and/or DACCS available. The carbon price at which DACCS was deployed as a backstop technology depended upon the assumed cost at which DACCS was available at scale. Carbon prices were between $\$$250 and $\$$500 per ton CO 2 when DACCS deployed as a backstop. The average CO 2 capture rate across all models in 2050 in the central net-zero scenario was 1.3 GtCO 2 /year, which implies a substantial upscaling of capacity to move and store CO 2 . Finally, hydrogen sensitivity scenarios showed that H 2 typically constituted a relatively small share of the overall U.S. energy system; however, H 2 deployed in applications that are considered hard to decarbonize, facilitating transition towards net-zero emissions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermal and solubility effects on fault leakage during geologic carbon storage

Geologic carbon storage (GCS) is a promising method for reducing anthropogenic CO 2 emissions to the atmosphere. To safely deploy GCS in the field, it is necessary to assess risks and the effect of uncertainty on safe storage. The effect of uncertainty can be quantified using batches of simulations, but the high computational costs of high-resolution simulations necessitate use of reduced-order models (ROMs). Previous work involves ROMs for quantifying the risk of different potential leakage paths from storage reservoirs to shallow formations. However, previous studies on development of fault-leakage ROMs have limited numbers of uncertain parameters and do not explicitly examine impacts of CO 2 solubility and thermal stresses on fault reactivation, which can generate high-permeability pathways and compromise CO 2 storage. Here, we analyze an ensemble of simulations considering CO 2 leakage from a storage reservoir to a shallow aquifer through a fault while varying a number of uncertain parameters related to thermo-hydro-mechanical properties and CO 2 injection. We show the effects of solubility on: free-phase CO 2 -leakage rates, brine-leakage rates, and poroelastic fault destabilization. We find that CO 2 solubility is more important for estimating free-phase CO 2 -leakage rates compared to brine-leakage rates or poroelastic fault destabilization. We also find that thermal stresses and overpressures have different spatial distributions within the fault, indicating that the spatial variability of overpressures due to variation in flow parameters does not necessarily make the spatial variability of thermal stresses negligible. We suggest the use of the CO 2 phase-change path as a variable in future fault-leakage ROMs.

03 NATURAL GAS↗

A study on computational fluid dynamics modeling of a refrigerated container for COVID-19 vaccine distribution with experimental validation

A key issue with the distribution of vaccines to prevent COVID-19 is the temperature level required during transport, storage, and distribution. Typical refrigerated transport containers can provide a temperature-controlled environment down to -30 °C. However, the Pfizer vaccine must be carefully transported and stored under a lower temperature between -80 °C and -60 °C. One way to provide the required temperature is to pack the vaccine vials into small packages containing dry ice. Dry ice sublimates from a solid to a gas, which limits the allowable transport duration. This can be mitigated by transporting in a -30 °C refrigerated container. Moreover, because the dry ice will sublimate and thereby release CO 2 gas into the transport container, monitoring the CO 2 concentration within the refrigerated container is also essential. In the present work, a 3D computational fluid dynamics model was developed based on a commercially available refrigerated container and validated with experimental data. The airflow, temperature distribution, and CO 2 concentration within the container were obtained from the simulations. The modeling results can provide guidance on preparing experimental setups, thus saving time and lowering cost, and also provide insight into safety precautions needed to avoid hazardous conditions associated with the release of CO 2 during vaccine distribution.

59 BASIC BIOLOGICAL SCIENCES↗

NRAP-Open-IAM: NRAP Open Source Integrated Assessment Model

Note: This is the last version (a2.6.1) of NRAP-Open-IAM released during NRAP Phase II in 2022. The latest version of NRAP-Open-IAM is available here: https://edx.netl.doe.gov/dataset/phase-iii-nrap-open-iam NRAP-Open-IAM is an open-source software product that enables quantification of containment effectiveness and leakage risk at storage sites in the context of system uncertainties and variability. NRAP-Open-IAM represents the next-generation in a line of systems-based computational models developed for quantitative geological carbon storage (GCS) risk assessment. The model comprises a set of reduced-order and analytical models of various components of the GCS system, potential leakage pathways, receptors of concern including impact to groundwater resources and the atmosphere, a framework to support stochastic simulation, time stepping, uncertainty quantification, other analytical functionality for scenario and risk-performance evaluation, and a basic graphical user interface to support scenario development, data input simulation definition, and basic post-processing and results display. As the NRAP Open-IAM functionality continues to evolve, we continue to add to its capability to develop quantitative, probabilistic, and time-dependent profiles of the evolution of risk at a GCS site and evaluate the influence of uncertain parameters on uncertainty in predicted risk. It can be used to quantify the dynamics of reservoir saturation plume and pressure-affected area, for evaluation of the area of potential groundwater impact (i.e., Area of Review) and monitoring requirements to support cost and regulatory analysis, and for consideration of different post-injection site care and closure scenarios. This submission contains the current version of NRAP-Open-IAM available for evaluation and testing. To use the NRAP-Open-IAM, download the source code (https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/4c24a3da-3b40-4ffe-9892-c807ae9f8760) then open the NRAP-Open-IAM user's guide (https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/8b27335a-343c-4836-b8a3-3ad0bdc9e669) to read more about the tool. Installation instructions for Windows, Mac, and Linux can be found in the "installers" folder of the extracted NRAP-Open-IAM folder and describe setup of environment (e.g., Python libraries) needed for proper work of the tool. Test of installation can be done by running "python openiam_setup_tests.py" in the "setup" folder. The installation test also runs a test suite to see if the NRAP-Open-IAM has been installed correctly. To run the test suite separately, run "python iam_test.py" in the "test" folder. User's guide: https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/8b27335a-343c-4836-b8a3-3ad0bdc9e669 Developer's guide: https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/3bc6ee7d-609d-4eb6-80ba-fa6130ee0313 Reservoir simulation data used in some examples distributed with NRAP-Open-IAM: - Kimberlina: https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/eb62cece-61b2-4037-9b6d-32407dde2ab8 - Kimberlina (compartmentalized): https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/366f9530-3b32-4b84-affe-ab2df1d9a8b5 - FutureGen 2.0: https://edx.netl.doe.gov/dataset/futuregen-2-0-1008-simulation-reservoir-lookup-table NRAP-Open-IAM GitLab repository: https://gitlab.com/NRAP/OpenIAM Related publications: - Bacon, D., Yonkofski, C., Brown, C., Demirkanli, D. and Whiting, J., 2019. Risk-based post injection site care and monitoring for commercial-scale carbon storage: Reevaluation of the FutureGen 2.0 site using NRAP-Open-IAM and DREAM. International Journal of Greenhouse Gas Control 90: 102784. - Bacon, D. Demirkanli, D., and White, S., 2020. Probabilistic risk-based Area of Review (AoR) determination for a deep-saline carbon storage site. International Journal of Greenhouse Gas Control 102: 103153. - Harp, D., Oldenburg, C., and Pawar, R., 2019. A metric for evaluating conformance robustness during geologic CO2 sequestration operations. International Journal of Greenhouse Gas Control 85: 100-108. - Lackey, G., Vasylkivska, V., Huerta, N., King, S., and Dilmore, R., 2019. Managing well leakage risks at a geologic carbon storage site with many wells, International Journal of Greenhouse Gas Control, 88 :182-194. - Vasylkivska, V., Dilmore, R., Lackey, G., Zhang, Y., King, S., Bacon, D., Chen, B., Mansoor, K., and Harp, D., 2021. NRAP-Open-IAM: A flexible open-source integrated assessment model for geologic carbon storage risk assessment and management, Environmental Modelling & Software, 143: 105114. Presentations: - Chen, B., Harp, D., and Pawar, R., A data assimilation approach (ES-MDA) coupling with NRAP-Open-IAM for quantifying uncertainty reduction in geological CO2 sequestration. AGUFM 2019: T44A-02. - Chen, B., and Harp, D., Improving risk analysis precision for geologic CO2 sequestration by quantifying the uncertainty reduction before and after acquiring monitoring data. 14th Greenhouse Gas Control Technologies Conference, Melbourne, Australia, 2018, pp. 21-26. - Harp, D., National Risk Assessment Partnership Task 2: Containment Assurance. No. LA-UR-19-28654, Los Alamos National Laboratory (LANL), Los Alamos, NM (United States), 2019. - Vasylkivska, V., King, S., Bacon, D., Harp, D., Chen, B., Mansoor, K., Onishi, T., Yang, Y., Zhang, Y., and Keating, E., NRAP-Open-IAM: An open-source integrated assessment model, poster, Mastering the Subsurface Through Technology Innovation, Partnerships and Collaboration: Carbon Storage and Oil and Natural Gas Technologies Review Meeting, Pittsburgh, PA, August 13-16, 2018. - Vasylkivska, V., Lackey, G., King, S., Wentworth, A., Huerta, N., Creason, C., DiGiulio, J., Yang, Y., and Dilmore, R., Long-term risk analysis of a geologic CO2 storage project during the post-injection period, SIAM Conference on Computational Science and Engineering, Spokane, WA, February 25-March 1, 2019. - Vasylkivska, V., Overview of the NRAP-Open-IAM tool for carbon storage (beta release), 2019 Annual NRAP Tool Users Meeting, Pittsburgh, PA, August 27, 2019. - Vasylkivska, V., Bacon, D., Chen, B., Dilmore, R., Harp, D., King, S., Lackey, G., Lindner, E., Liu, G., Mansoor, K. and Zhang, Y., NRAP-Open-IAM: A new, open-source code for integrated assessment of geologic carbon storage containment effectiveness and leakage risk, poster, American Geophysical Union Fall Meeting 2020 (virtual meeting), December 2020. - Vasylkivska, V., NRAP open-source integrated assessment model and relevant application, oral presentation, NRAP workshop "NRAP Tools for Geologic Carbon Storage Risk-Based Decision Making" held in conjunction with Groundwater Protection Council (GWPC) 2021 Annual Forum (virtual meeting), Salt Lake City, UT, September 2021. - Vasylkivska, V., NRAP-Open-IAM: open-source integrated assessment model, digital poster/demonstration, software demonstration session, 2022 Carbon Management Project Review Meeting, August 16, 2022

AoR↗

Performance and cost analysis of liquid fuel production from H 2 and CO 2 based on the Fischer-Tropsch process

Electro-fuels can be produced from concentrated sources of carbon dioxide and hydrogen using electricity generated from renewable sources; this process enables energy storage at high volumetric energy density. Among the electro-fuels options, FT (Fischer-Tropsch) fuel is attractive for heavy-duty trucks and non-road transportation applications. This study conducts a techno-economic analysis of FT liquid fuel production from H 2 and CO 2 using a detailed performance analysis. Minimum fuel selling price is estimated for a broad range of H 2 and CO 2 prices and for a range of potential CO 2 credits. The analysis indicates that H 2 price has the largest impact on the minimum selling price of FT fuel. FT fuel production with a CO 2 price of $17.3/metric ton requires an H 2 price of $0.8/kg to be cost-competitive with the pre-tax petroleum diesel price of $3.1/gal in 2050 (before the application of any CO 2 credits). When the H 2 price is $2.0/kg from central water electrolysis (2020 target), the minimum selling price of the FT fuel is $5.4–5.9/gal. A sensitivity analysis shows that future system optimization of FT fuel production could focus on improving the H 2 and CO 2 recycle contributions and FT fuel conversion ratio. The analysis results can be combined with various upstream systems for H 2 and CO 2 production.

08 HYDROGEN↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗

Deep learning model for fast, science-based forecasting of fluid migration along faults in geologic carbon storage scenarios

Effective long-term geologic storage depends on robust site selection and credible, science-based forecasting of subsurface behavior to ensure storage integrity. For this work, we develop a deep learning–based reduced-order model (ROM) to quantify potential carbon dioxide (CO₂) and brine migration through geological faults. The ROM combines a Transformer model for binary classification and a Stacked Ensemble for regression, trained on a comprehensive dataset generated from 1400 physics-based reservoir simulations. Key geologic and operational parameters—including fault geometry, reservoir structure, and injection conditions—were systematically varied to capture a wide range of fluid migration scenarios. The ROM accurately predicts the onset of migration, cumulative migration volumes of both CO₂ and brine, and associated migration rates, as compared to an independent set of validation simulations, while significantly reducing computational cost compared to traditional simulation methods. Model performance was evaluated across diverse fault configurations, revealing that shallow reservoir geometry and fault angle are among the most influential factors governing migration behavior. Sensitivity analysis using SHapley Additive exPlanations (SHAP) provided interpretability, revealing distinct patterns in how geological and operational features drive transient versus cumulative migration outcomes. The ROM’s ability to rapidly simulate fault migration scenarios enables efficient sensitivity analyses, scenario evaluations, and decision support for site selection and monitoring design. This approach enhances the safety, scalability, and long-term operational performance of geologic carbon storage (GCS) systems by providing a robust, interpretable tool for predicting subsurface fluid migration and assessing fault-related migration potential.

42 ENGINEERING↗

Catalytic Oxygen Reduction for Deep O 2 Removal from CO 2 Streams

Streams of CO 2 from various capture processes may contain several impurities of which O 2 is often overlooked as a problematic impurity. Because of its reactivity, the National Energy Technology Laboratory has recommended a stringent limit, less than 10 ppm, for the O 2 level in treated CO 2 products for safe transport, storage, and utilization. Here, in this study, a variety of catalytic oxygen reduction approaches using commercial automotive exhaust emission catalysts are evaluated for O 2 removal from CO 2 streams using different reducing agents, including H 2 , CO, CH 3 OH, and CH 4 . When the amount of reductant added into the feed is carefully controlled, H 2 , CO, or CH 3 OH can effectively remove O 2 from 1.5% to below 10 ppm with a single-reactor design (>99.93% removal efficiency), while simultaneously meeting the impurity limits for other species. With CH 4 as a reductant, it is challenging to simultaneously meet the the O 2 and CO specifications in a single-reactor design because CH 4 also reacts with CO 2 to produce high levels of CO in the stream (at several hundred ppm). A dual-reactor design is developed to enable the use of CH 4 , a readily available and low-cost reductant, for the purification of CO 2 streams to meet the specifications for O 2 and other impurities.

CO2 purification↗

Offshore Oil and Gas Infrastructure Reuse for CCS: Opportunities and Challenges in the U.S. Gulf of Mexico

The United States Gulf of Mexico has historically been a significant oil and gas producing region and continues to produce hydrocarbons today. As such, significant investments have been made to install oil and gas infrastructure such as pipelines, platforms, and wells. As these assets reach the end of their useful life or production associated with the assets is curtailed, the assets become a liability for both the owner/operators and the U.S. and state governments responsible for regulating the assets. There are costs and risks associated with safely decommissioning the assets, and in some cases, the assets may be abandoned (e.g., the owner is no longer a going concern). In parallel, carbon capture and storage (CCS) technology has developed in the United States and interest and incentives for CCS projects have accelerated in recent years, with many public announcements of CCS projects in development in the U.S. Gulf of Mexico region. The region is particularly well-suited to CCS due to the high density of industry on the coastline (i.e., CO 2 sources) and favorable geology in the near-offshore region. CCS also requires the use of many of the same assets required for oil and gas production (pipelines, platforms, wells) and the oil and gas industry has direct experience with CO 2 transport and injection (i.e., EOR). Therefore, the combination of existing infrastructure in close proximity to potential CCS project sites appears to provide a potential “win-win” solution for re-use of existing oil and gas assets. This paper presents a high-level evaluation of oil and gas infrastructure in the Gulf of Mexico with the goals of identifying the scale of the opportunity (e.g., how much existing infrastructure is realistically re-usable), identifying gaps in knowledge/policy/information required to evaluate existing infrastructure for re-use, and proposing key actions that could be pursued to further the assessment of existing infrastructure re-use for CCS.

Infrastructure, reuse, re-purpose, oil and gas, pi↗

Techno-economic analysis and network design for CO 2 conversion to jet fuels in the United States

The conversion of carbon dioxide (CO 2 ) into jet fuel holds significant potential for reducing CO 2 emissions, providing an alternative to carbon-based resources, and offering a renewable means of energy storage. The objective of this study is to conduct a techno-economic analysis and optimize the supply chain network for converting CO 2 to jet fuel in the United States, aiming to minimize total costs while assessing the environmental and economic feasibility of two CO 2 conversion pathways. This first pathway is based on Fischer-Tropsch synthesis (FTS), and the other one is based on the valorization and upgrading of light methanol (MeOH). Incorporating spatial and techno-economic data, a mixed-integer linear programming model was developed to select source plants and conversion pathways, locations of conversion refinery sites, and the amount of captured CO 2 across the United States. The optimal results indicate that the FTS pathway is adopted at all selected refineries when the hydrogen price is 1000 dollars/t and the operating cost, mainly electricity used in conversion, is reduced to 5 % of its current level. Under this scenario, the total annual profit is 8 billion dollars, and the net carbon emissions are -88,783,284 tons. The sensitivity analyses reveal that the prices of electricity and hydrogen significantly contribute to total production costs. The CO 2 recycle percentage of the FTS pathway influences the choice of applied pathways at refineries. Additionally, a higher conversion rate holds a substantial promise for reducing the total production cost and can make the MeOH pathway a viable choice.

10 SYNTHETIC FUELS↗

Real-Time Monitoring of Gas-Phase and Dissolved CO 2 Using a Mixed-Matrix Composite Integrated Fiber Optic Sensor for Carbon Storage Application

Novel chemical sensors that improve detection and quantification of CO 2 are critical to ensuring safe and cost-effective monitoring of carbon storage sites. Fiber optic (FO) based chemical sensor systems are promising field-deployable systems for real-time monitoring of CO 2 in geological formations for long-range distributed sensing. Here, a mixed-matrix composite integrated FO sensor system was developed with a purely optical readout that reliably operates as a detector for gas-phase and dissolved CO 2 . A mixed-matrix composite sensor coating consisting of plasmonic nanocrystals and hydrophobic zeolite embedded in a polymer matrix was integrated on the FO sensor. The mixed-matrix composite FO sensor showed excellent reversibility/stability in a high humidity environment and sensitivity to gas-phase CO 2 over a large concentration range. This remarkable sensing performance was enabled by using plasmonic nanocrystals to significantly enhance the sensitivity and a hydrophobic zeolite to effectively mitigate interference from water vapor. The sensor exhibited the ability to sense CO 2 in the presence of other geologically relevant gases, which is of importance for applications in geological formations. A prototype FO sensor configuration which possesses a robust sensing capability for monitoring dissolved CO 2 in natural water was demonstrated. Reproducibility was confirmed over many cycles, both in a laboratory setting and in the field. More importantly, we demonstrated on-line monitoring capabilities with a wireless telemetry system, which transferred the data from the field to a website. The combination of outstanding CO 2 sensing properties and facile coating processability makes this mixed-matrix composite FO sensor a good candidate suitable for practical carbon storage applications.

54 ENVIRONMENTAL SCIENCES↗

Near-Term Electricity Requirement and Emission Implications for Sustainable Aviation Fuel Production with CO 2 -to-Fuels Technologies

Aviation contributed approximately 10% of the U.S. transportation sector's greenhouse gas (GHG) emissions and about 3% of the nation's total GHG production before the coronavirus disease (COVID-19) pandemic (EPA 2022). Unlike the ground transportation sector, which can be decarbonized by using batteries and hydrogen fuel cell powertrain technologies, the technical and economic challenges of aviation electrification open the opportunity for CO 2 utilization (CO2U) using clean power sources. The U.S. government set a goal to produce 3 billion gallons per year of sustainable aviation fuels (SAF) by 2030 and scale up the production to 35 billion gallons per year by 2050 (Bioenergy Technologies Office 2022). In this report, we examine three potential locations, in California, Iowa, and Louisiana, for SAF production using two production pathways that are expected to be available by 2030. We analyze the electricity cost to satisfy 10% of the SAF production potential for the select locations. Specifically, we consider (1) retail electricity cost from the default local utility in each location; (2) physical power purchase agreement (PPA) for renewable power and battery storage hybrid systems with preset prices; (3) financial PPA from a dedicated renewable plant; and (4) estimated real-time pricing (RTP) from the wholesale power market with utility delivery adders. Retail rates are available for the three potential locations; however, the developer should negotiate with the local utility in Iowa for new tariff riders, because the load of the proposed SAF plant (1.4 GW) is significantly higher than the current industrial tariff structure requirement (200 kW). The developers are not able to claim federal credits (i.e., the Inflation Reduction Act of 2022) when sourcing electricity from local utilities. Developers could consider prioritizing physical and financial PPAs as purchase options. While physical PPAs can be imported out of state, this structure imposes availability issues as developers must locate in the same electricity grid regions. Financial PPAs do not have the same location restrictions and provide the same cost savings as physical PPAs, but financial PPAs impose financial risks in the event of system curtailment and grid interruption. RTPs are available for customers in California with flexible load and hourly load management capability; however, utilities in our studied regions in Louisiana and Iowa only offer time-of-use and curtailment programs to incentivize lower energy usage in peak hours. These utilities do not currently offer RTP programs, and the developer may need to have further negotiations with the local utilities to access RTP programs. The results show that purchased electricity prices may range from 2.6 cents/kWh to 7.1 cents/kWh for the three studied plants.

02 PETROLEUM↗

Technoeconomic analysis and life cycle assessment of purification processes for captured CO 2 streams

Captured carbon dioxide (CO 2 ) streams contain impurities that must be removed to meet specifications for safe transport, storage, and utilization. Among these impurities, oxygen poses challenges due to its high reactivity and potential to cause corrosion, motivating stringent purity limits below 10 ppmv. Building on recent experimental demonstrations of catalytic oxygen removal using hydrogen (H 2 ), carbon monoxide (CO), methanol (CH 3 OH), and methane (CH 4 ) as reducing agents, this study presents a technoeconomic (TEA) and life cycle assessment (LCA) of these four catalytic purification pathways. Process flowsheets were developed and simulated in Aspen Plus for CO 2 streams representative of both low-temperature and high-temperature capture processes, with integrated heat recovery and energy optimization. Results showed that total purification costs were dominated by feedstock procurement and electricity consumption. Among the studied reducing agents, the CH 4 -assisted route achieved the lowest purification cost and highest CO 2 recovery. Sensitivity analyses showed that the H 2 route became competitive at H 2 prices below $\$$0.56/kg to $\$$0.84/kg, depending on the CO 2 feed temperature conditions. In conclusion, environmental impacts were primarily driven by indirect CO 2 emissions from raw material production and utility consumption.

CO2 pipeline specifications↗

MgO Nanostructures on Cu(111): Understanding Size- and Morphology-Dependent CO 2 Binding and Hydrogenation

To design and optimize cost-effective technologies for the capture, utilization, and storage of carbon dioxide (CO 2 ), we need a fundamental knowledge and control of chemical interactions associated with the capture and conversion of the molecule into high-value chemicals, minerals, and all kinds of materials. Bulk magnesium oxide (MgO) is frequently used for the trapping and storage of CO 2 by generation of magnesium carbonates. In this study, the growth and reactivity of MgO nanostructures on a Cu 2 O/Cu(111) substrate were investigated using scanning tunneling microscopy (STM) and synchrotron-based ambient-pressure X-ray photoelectron spectroscopy (AP-XPS). For extremely small concentrations of Mg (~ 0.01 monolayer (ML)), a well-ordered film of copper oxide with small clusters (0.2-0.5 nm in width, 0.4-0.6 Å in height) of embedded MgO was seen. At a coverage of 0.1 ML, MgO nanoparticles with a width of 0.4 to 1 nm and a height of ~ 1.5 Å were randomly distributed on the copper oxide. Further, random distribution was also observed when the MgO coverage was raised to 0.25 ML, with the width of the MgO particles increasing to 2-2.5 nm and the height reaching 2 Å. These oxide nanostructures displayed a high reactivity towards CO 2 and H 2 that is not seen for bulk MgO. Dissociation of H 2 was observed at room temperature with reaction of the H adatoms with CuO x and C-containing groups. On the small MgO nanostructures (< 1 nm in width), instead of plain carbonate formation, there was dissociation of CO 2 into CO and C species, opening reaction channels for the conversion of this harmful molecule into oxygenates and light alkanes.

03 NATURAL GAS↗

Multiscale Electricity Modeling for Evaluating Carbon Capture and Sequestration Technologies (Final Report)

Carbon capture and sequestration (CCS) technologies that can operate with a high degree of operating flexibility could provide necessary electric grid flexibility in a system with high shares of variable renewables. This project examines the deployment and dispatch potential of twelve unique flexible CCS (FLECCS) technologies that encompass post-combustion carbon dioxide (CO 2 ) capture designs, concepts using a storage media to enable energy arbitrage, and hybrid processes that integrate CCS with direct air capture (DAC) for flexibility with net zero or negative CO 2 emissions. FLECCS technology potential is explored with a multi-model, multi-scale framework including the Regional Energy Deployment System (ReEDS) electric sector capacity expansion model (CEM) and the PLEXOS production cost model (PCM). Innovative methods were developed to represent FLECCS technology operating modes, performance, and cost in the two models. ReEDS was then used to simulate nine scenarios for each FLECCS technology, three CO 2 emissions price futures reaching $\$$150, $\$$225, and $\$$300/tCO 2 in 2050; and three scenarios for FLECCS technology deployment favorability relative to competing technologies. For each CO 2 price and reference FLECCS favorability, the 2050 infrastructures from ReEDS model are downscaled and implemented in PLEXOS to examine hourly dispatch under detailed operational constraints that are not included in ReEDS. FLECCS technologies exhibited a wide range of deployment potential ranging from none to several hundred gigawatts of capacity, with outcomes highly sensitive to input cost and performance parameters that are inherently highly uncertain. When deployed, FLECCS tended to displace a combination of wind, solar, and natural gas-based technologies rather than supporting increased renewable deployment. As a result, CO 2 emissions reductions facilitated by FLECCS deployment tended to come with higher overall system costs and electricity prices. When economically competitive, FLECCS technologies can contribute significant flexible generation and firm capacity to the grid, but continued technology development and an expanded analytical scope are necessary to fully understand FLECCS deployment potential its impact on the electric power sector. Follow-on analysis incorporating captured CO 2 tax credit value from the Inflation Reduction Act (IRA) and other potential policy scenarios could be particularly valuable, as this policy can substantially change the relative competitiveness of FLECCS technologies.

03 NATURAL GAS↗

Role of Intermolecular Interactions in Deep Eutectic Solvents for CO 2 Capture: Vibrational Spectroscopy and Quantum Chemical Studies

Recent research and reviews on CO 2 capture methods, along with advancements in industry, have highlighted high costs and energy-intensive nature as the primary limitations of conventional direct air capture and storage (DACS) methods. In response to these challenges, deep eutectic solvents (DESs) have emerged as promising absorbents due to their scalability, selectivity, and lower environmental impact compared to other absorbents. However, the molecular origins of their enhanced thermal stability and selectivity for DAC applications have not been explored before. Therefore, the current study focuses on a comprehensive investigation into the molecular interactions within an alkaline DES composed of potassium hydroxide (KOH) and ethylene glycol (EG). Combining Fourier transform infrared (FT-IR) and quantum chemical calculations, the study reports structural changes and intermolecular interactions induced in EG upon addition of KOH and its implications on CO 2 capture. Experimental and computational spectroscopic studies confirm the presence of noncovalent interactions (hydrogen bonds) within both EG and the KOH-EG system and point to the aggregation of ions at higher KOH concentrations. Additionally, molecular electrostatic potential (MESP) surface analysis, natural bond orbital (NBO) analysis, quantum theory of atoms-in-molecules (QTAIM) analysis, and reduced density gradient-noncovalent interaction (RDG-NCI) plot analysis elucidate changes in polarizability, charge distribution, hydrogen bond types, noncovalent interactions, and interaction strengths, respectively. Evaluation of explicit and hybrid models assesses their effectiveness in representing intermolecular interactions. This research enhances our understanding of molecular interactions in the KOH-EG system, which are essential for both the absorption and desorption of CO 2 . The study also aids in predicting and selecting DES components, optimizing their ratios with salts, and fine-tuning the properties of similar solvents and salts for enhanced CO 2 capture efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗