Search NASA⌕ Search

SEARCH · Search NASA

Results for “COGENERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

UNC Chapel Hill

This is a combined heat and power (CHP) project profile on a 32 MW cogeneration plant at UNC Chapel Hill in North Carolina.

AMO↗

Establishing a Common Definition for Zero Energy Buildings: Time to Move the Market

To change the current paradigm from buildings being consumers of energy to producers of energy requires a common language to facilitate market transformation. Common definitions help create market movement by sharing concepts across market actors. While the term 'zero energy buildings' has been in the marketplace for over 20 years, no common definition had been established. US DOE, last year, embarked on a process to evaluate current definitions and solicit industry input to formulate a common definition and nomenclature for zero energy buildings. This definition uses commonly available site measurements and national conversion factors to define zero energy buildings on a source energy basis for a variety of boundary conditions including building, portfolio, campus, and community. Issues addressed include multiple fuel types, cogeneration, and renewable energy certificates. This paper describes the process used to arrive at the definition, looks at methods of calculating site to source energy conversions, and how boundary decisions affect a robust and stable definition that can be used to direct programs and policies for many years to come. This stability is critical to move building investments towards buildings that produce as much energy as they consume.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Introducing GEOPHIRES v2.0: Updated Geothermal Techno-Economic Simulation Tool: Preprint

This paper presents an updated version of the geothermal techno-economic simulation tool GEOPHIRES (GEOthermal Energy for Production of Heat and electricity (IR) Economically Simulated). GEOPHIRES combines reservoir, wellbore, surface plant and economic models to estimate the capital, and operation and maintenance costs, lifetime energy production, and overall levelized cost of energy of a geothermal plant. The available end-use options are electricity, direct-use heat and cogeneration. The main updates in the new version include conversion of the source code from FORTRAN to Python, the option to couple to an external reservoir simulator, updated cost correlations, and more flexibility in selecting the time step and number of injection and production wells. An overview of all the updates and two case-studies to illustrate the tool's new capabilities are provided in this paper.

15 GEOTHERMAL ENERGY↗

Introducing GEOPHIRES v2.0: Updated Geothermal Techno-Economic Simulation Tool

This paper presents an updated version of the geothermal techno-economic simulation tool GEOPHIRES (GEOthermal energy for Production of Heat and electricity ('IR') Economically Simulated). GEOPHIRES combines engineering models of the reservoir, wellbores, and surface plant facilities of a geothermal plant with an economic model to estimate the capital and operation and maintenance costs, lifetime energy production, and overall levelized cost of energy. The available end-use options are electricity, direct-use heat, and cogeneration. The main updates in the new version include conversion of the source code from FORTRAN to Python, the option to import temperature data (e.g., measured or from stand-alone reservoir simulator), updated cost correlations, and more flexibility in selecting the time step and number of injection and production wells. In this paper, we provide an overview of all the updates and two case studies to illustrate the tool's new capabilities.

15 GEOTHERMAL ENERGY↗

A Dual Stage Sodium Thermo-Electro-Chemical Converter

The need for reliable and distributable energy sources is evident given the current forecasting of the world’s energy demand [1]. One prominent obstacle is the lack of an efficient direct heat-to-electricity conversion technology. The sodium thermo-electro-chemical converter (Na-TECC) is a highly efficient thermally regenerative electrochemical system (TRES) that can fill this void. The advantage of the Na-TECC over other direct conversion technologies is that it is a closed device (unlike fuel cells) requiring nothing more than a heat input (similar to thermoelectrics). It also has a high power density (> 1 W/cm2) and specific power up to 0.5 kW/kg , with the potential to achieve > 45% heat to electricity conversion efficiencies [2]. Furthermore, the converter rejects heat at a temperature hot enough to make it amenable for cogeneration, potentially under air-cooled operation. This electrochemical technology uses a special ion-selective solid-electrolyte called beta-alumina (Na2O•11Al2O3), that is highly conductive to sodium cations. A more conducting variation of this compound is beta”-alumina (Na2O•MgO•5Al2O3), where the magnesium acts as a stabilizer [3]. In the device, liquid sodium enters an evaporator where it is heated isobarically and vaporizes. The vapor is then oxidized at the interface between the anode and the solid-electrolyte. The Na-TECC generates electric power by allowing the high pressure oxidized sodium vapor ions to expand isothermally through the solid-electrolyte from the anode to the cathode. The liberated electrons are simultaneously conducted through an external load and recombine with the cations at the cathode. The low pressure sodium vapor is subsequently condensed and a wick pumps the liquid into the high pressure plenum to complete the cycle. Previous Na-TECCs have achieved efficiencies of 18% due to practical losses, whereas the potential efficiencies are above 45% [4]. Thermodynamic limitations and design constraints have limited previous devices from attaining these record efficiencies. Specifically, the maximum potential voltage in these previous devices was substantially reduced by the kinetic limitations of the charge transfer in the cathode (referred to as the overpotential) and by Joule heating losses due to the solid-electrolyte resistance, electrode resistance, and current collector resistance. Moreover, previous devices experienced a steady loss in performance throughout their lifetime. The drop in performance has been attributed to the electrolyte undergoing thermal and chemical breakdown due to crack propagation, loss of sodium oxide, and the formation of molten dendrites that create electrical shorts [5]. Finally, previous designs have also had a substantial problem with proper thermal management, with some showing thermal losses as great as 50% of the heat input. To improve the efficiency, a dual stage conversion process is being explored. Rather than using one isothermal expansion step, the dual cycle will employ two separate electrolytes to allow two separate expansion steps: one at the high temperature, and another at an intermediate temperature. This new cycle is thermodynamically favorable as it allows for regeneration from the isobaric cooling of the first expansion step, and reheat to complete the expansion in the second step. This allows the engine to reach a lower condenser temperature than its single stage counterpart, thus increasing the overall efficiency. The temperature drop across each electrolyte in the dual stage device (e.g., ~ 400 K) is smaller than the temperature drop across a comparable single stage device (e.g., ~ 800 K). This is amenable for better thermal management and allows for less heat loss. This will also mitigate the thermal shock across the very thin (< 1 mm) solid electrolytes, reduce crack propagation and limit the percolation of the molten dendrites, and ultimately increase the lifetime of the device. As an additional benefit the dual stage can be designed using planer geometries, rather than tubular geometries used in previous single stage models, which can be manufactured less expensively. This modified geometry can be tailored to improve the thermal management by reducing the radiation losses, which has been the biggest source of thermal losses [2]. A dual stage concept for the Na-TECC has never been demonstrated in literature. In this presentation, the operation of a single stage device will be revisited and, by adopting concepts used for similar converters, the thermodynamic operation of the dual stage will be developed [6]. Using the dual stage approach, the efficiency and power equations have been redefined to include regeneration and reheat. Questions such as what current densities optimize the power output or which intermediate temperature maximizes the efficiency will also be answered. Initial calculations of the dual stage show that the thermal management is the most sensitive parameter. Although the ideal voltage produced by the dual stage can be higher, there are potential drawbacks. For example, by using a lower condenser temperature the dual stage device will have a higher open circuit voltage, but it will also have a larger overpotential due to the limited cathodic kinetics that occur at a lower temperature. In short, there are several trade-offs in this device that need to be balanced. It will be demonstrated that the dual stage device must have lower thermal losses than a single stage device if it is to have a higher efficiency.

14 SOLAR ENERGY↗

Energy Efficient, Cost-Effective Power and Co-Generation Technologies: Techno-Environmental Analysis

Development of energy solutions for addressing grid resiliency and energy efficiency while lowering greenhouse gas emissions is critical in today’s energy scenario. Chemical energy provides on demand power. Cogeneration technologies offer numerous benefits in meeting the growing energy demand while lowering the impact on environment. Utilization of waste heat from prime movers in conjunction with energy efficient heat pumps and renewable photovoltaics is an attractive approach. Efficient utilization of available resources to support current and future building energy needs targeting grid resiliency, energy and environmental security via co-generation approaches is the focus of this study. A detailed techno-environmental analysis of hybrid system configurations consisting of conventional and emerging technologies utilizing natural gas, electric grid, and renewable power resources along with heat recovery systems and heat pump technologies are analyzed and presented. The key objective is to present integrated system configurations and thermodynamic analysis of various co-generation systems suitable for providing building energy. Design solutions targeting low carbon footprint and high energy efficiency are presented.

Cheekatamarla, Praveen↗

Generation IV Benchmarking of TRISO Fuel Performance Models Under Accident Conditions Final Report

The Generation IV International Forum (GIF) is a co-operative international endeavor of fourteen members organized to carry out the research and development needed to establish the feasibility and performance capabilities of the next generation nuclear energy systems. GIF selected six reactor technologies, amongst which is the Very High Temperature Reactor (VHTR) that is primarily dedicated to the cogeneration of electricity and hydrogen. The technical basis for VHTR is the tristructural isotropic (TRISO)-coated particle fuel, the graphite as the core structure, helium coolant, as well as the dedicated core layout and lower power density to removal decay heat in a natural way. At the heart of safety features of the VHTR concept lie the TRISO fuel particles that are designed to keep their structural integrity and retain fission products at temperatures up to 1600°C. As part as the design and future operation of VHTRs, a key aspect is the accurate prediction of fuel performance under irradiation and accident conditions. Modeling and simulation allow prediction of TRISO fuel behavior when subject to neutron flux and in high temperature accident scenarios. The refinement of the fuel performance models and codes is performed by comparison to in-pile and out-of-pile experimental data that reproduce the expected irradiation conditions in high temperature gas-cooled reactors (HTGRs). Historically, the International Atomic Energy Agency (IAEA) developed a benchmark dedicated to the validation of predictive methods for fuel and fission product behavior through the Coordinated Research Program CRP-2 (IAEA, 1997). CRP-2 was later updated to cover fuel fabrication, quality assurance, irradiation performance, safety testing, and spent fuel. The scope of the resulting CRP-6 benchmarks focused on HTGR fuel performance and fission product release (IAEA, 2012). Taking advantage of additional TRISO fuel fabrication, irradiation, and safety testing campaigns, GIF launched a Generation IV Benchmarking of TRISO Fuel Performance Models under Accident Conditions in late 2015. This GIF benchmark is a three-year program steered by Idaho National Laboratory (INL, USA). The other participants include the Japan Atomic Energy Agency (JAEA, Japan) and the Korea Atomic Energy Research Institute (KAERI, Korea). The objectives of the benchmark are to: follow on the IAEA CRP benchmarks, (2) model fission product release under accident conditions, (3) compare results obtained by the fuel performance modeling codes of the benchmark participants, and (4) compare these code predictions to experimental data. Safety tests chosen for modeling include the first and second experiments of the Advanced Gas Reactor program (AGR-1 and AGR-2) and the High Flux Reactor (HFR) EU1bis experiment. This report presents the results obtained by the three research institutions using their respective fuel performance modeling codes. Comparisons of the corresponding fission product release predictions are made with experimental data from AGR-1, AGR-2, and HFR-EU1bis. The benchmark results show good agreements between all participants but also show a general trend of over-prediction of the experimental release data, which is mainly attributed to the use of over-estimated diffusion coefficients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modular High Temperature Gas-Cooled Reactor: Safety Design Approach

Deployment Objectives Flexibly co-locate with new industry users of nuclear energy Steam and electric cogeneration applications Direct process heat with temperature ranges from 700°C to 950°C Enabling Requirements Meet regulatory dose limits at the Exclusion Area Boundary (EAB) 25 rem Total Effective Dose Equivalent (TEDE) for duration of the release from 10 CFR 50.34 (10 CFR 52.79) at Exclusion Area Boundary (EAB) for design basis accidents EAB is estimated approximately 400 meters from the modular HTGR plant (to support co-location with industrial facilities) Meet safety goals for cumulative individual risk for normal and off-normal operation Design goal: meet EPA Protective Action Guides (PAGs) at EAB 1 rem TEDE for sheltering Design basis and beyond design basis events are considered Realistically evaluated at the EAB Emergency planning and protection

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Role of Heat-to-Power Technologies in Building Decarbonization

This paper presents the energy, economic, and environmental benefits associated with different heat-to-power technologies such as Thermoelectrics, Thermophotovoltaics, and Thermionics. Hybrid configurations consisting of heat pumps, heat-to-power systems, and renewable PV in cogeneration and trigeneration modes of operation will be presented. The role of such technologies in lowering the primary energy consumption, carbon dioxide emissions while improving the energy resiliency and serving the needs of underprivileged communities will be discussed. The key barriers of affordability and potential solutions for large scale implementation of these promising technologies are presented.

Cheekatamarla, Praveen↗

High Fidelity Simulations of Air-Cooled Reactor Cavity Cooling System

Nuclear energy is increasingly acknowledged as pivotal in the global shift towards cleaner energy solutions. Advanced nuclear technologies, including High Temperature Gas-cooled Reactors (HTGRs), stand out as appealing options among Generation IV reactors due to their high temperature heat output and potential for cogeneration. HTGR designs incorporate passive safety systems, such as the Reactor Cavity Cooling System (RCCS), which utilize natural principles to manage heat dissipation from the reactor pressure vessel (RPV) during accidents or routine shutdowns. Regulatory bodies require thorough validation of safety systems like the RCCS to ensure they meet specified standards. Consequently, there is a pressing need within the industry for advanced simulation tools capable of assessing these systems’ performance accurately. There is a knowladge gap in the literature concerning high-fidelity data for the RCCS, which motivates the focus of this study. This research focuses on a specific RCCS designed for the Modular High-Temperature Gas Reactor developed by General Atomics (GA- MHTGR). Experimental studies on a scaled version of the air-cooled RCCS of GA-MHTGR were conducted by the University of Wisconsin-Madison. This work contributes to a broader initiative aimed at establishing a numerical benchmark based on the UW-Madison experiments. As first step we performed high fidelity simulations of the experimental facility setup, to analyze flow physics in such systems and validate NekRS and the MOOSE heat transfer and radiation modules.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Cost-Performance Analysis of a Sodium Heat Engine for Distributed Concentrating Solar Power

We present that a sodium thermal electrochemical converter (Na-TEC) generates electricity directly from heat through isothermal expansion of sodium ions across a beta"-alumina solid-electrolyte. This heat engine has been considered for use with conventional concentrating solar power (CSP) systems before. However, unlike previous single-stage devices, the improved design uses two stages with an interstage reheat, allowing more economical and efficient conversion up to 29% at a hot side temperature of 850 °C. Herein, a cost-performance analysis for this improved design assesses opportunities for distributed-CSP in the context of micro-combined heat and power systems. A high-level techno-economic analysis (TEA) is presented that explores four scenarios where a Na-TEC is used as the heat engine for a distributed-CSP system. Overnight capital cost and levelized cost of electricity (LCOE) are estimated for a system lifetime of 30 years, revealing that overnight capital costs in a range from $3.57 to $17.71 per W e are feasible, which equate to LCOEs from 6.9 to 17.2 cents kWh e -1 . This analysis makes a significant contribution by concurrently quantifying the efficiency and unit costs for a range of multistage configurations, and demonstrating that a Na-TEC may be a promising alternative to Stirling engines for distributed-CSP systems at residential scale of 1–5 kW e .

14 SOLAR ENERGY↗

Integrating Solar Energy, Desalination, and Electrolysis

Solar electricity enables the advancement and deployment of technologies that are strongly influenced by clean energy availability and cost. The economics of both desalination and hydrogen production from water electrolysis are dominated by the cost of energy, and the availability of inexpensive solar energy creates markets and offers incentives to the desalination and electrolyzer industries. In this report the production of high-purity water and hydrogen from seawater is focused on. Current electrolyzers require deionized water so they need to be coupled with desalination units. It is shown that such coupling is cost effective in hydrogen generation, and it also offers benefits to thermal desalination, which can utilize waste heat from electrolysis. Furthermore, such coupling can be optimized when electrolyzers operate at high current density, using low-cost solar and/or wind electricity, as such operation increases both hydrogen production and heat generation. Results of technoeconomic modeling of polymer electrolyte membrane electrolyzers define thresholds of electricity pricing, current density, and operating temperature that make clean electrolytic hydrogen cost competitive with hydrogen from steam methane reforming (SMR). By using 2020 hourly electricity pricing in California and Texas, it is estimated that hydrogen can be produced from seawater in coupled desalination-electrolyzer systems at prices near $2 kg -1 H 2 , reaching cost parity with hydrogen produced from SMR.

14 SOLAR ENERGY↗

Detailed thermodynamic investigation of an ICE-driven, natural gas-fueled, 1 kWe micro-CHP generator

Here, the purpose of this work is to record the baseline performance of a state-of-the-art micro-combined heat and power (mCHP) system. A second goal of this work is to provide detailed thermodynamic first and second law performance measurements of the internal combustion engine and generator subsystems. A global technology survey was conducted to identify the leading mCHP systems in the 1 kW electric range. The Honda ECOWILL was identified as the state-of-the-art system in the United States, and an unused unit was procured. The ECOWILL underwent round-robin performance testing at three independent laboratories. First law (energy) and second law (exergy) analyses were conducted on the steady state data. Analysis revealed the ECOWILL operated at a first law electrical efficiency of 23.5 ± 0.4% and a utilization factor of 74.5 ± 3.2%. The primary energy loss was heat transfer from the device, followed by chemical and thermal energy in the exhaust stack. The second law analysis showed the ECOWILL operated at a second law electrical efficiency of 23.1 ± 0.4% and total (including exergy in both the electrical and recovered waste heat streams) second law efficiency of 30.2 ± 2.3%. Key areas of exergy destruction were, in decreasing magnitude, heat transfer, combustion irreversibility, and generator and friction losses.

42 ENGINEERING↗

Opportunities for installed combined heat and power (CHP) to increase grid flexibility in the U.S.

Increasing use of renewable energy requires sufficient grid flexibility to address uncertainty and variability in electricity generation. Previous studies suggest that combined heat and power (CHP) systems may support grid flexibility but they do not consider operating hours. In this paper, we used CHP operating data and determined annual and monthly availability of the installed CHP capacity from various sectors (e.g., utility, independent power producer, commercial, and industrial) in all seven U.S. independent system operators (ISOs) and regional transmission organizations (RTOs). Also, we estimated hourly CHP availability installed in five facility types (i.e., hospitals, universities, hotels, offices, and manufacturing) in the state of New York. The results show that regardless of ISO/RTO, sector, or season, more than 40% of the installed CHP capacity (0.7–8.7 GW) was not fully utilized in 2019; the results are similar for 2018. This available CHP capacity accounted for up to 9% of the ISO/RTO's peak electric demand, which may yield cost savings up to $16 billion by avoiding installation costs of new natural gas combustion or combined-cycle turbines. To exploit the available CHP capacity to enhance grid flexibility, we recommend different policy implications including flexible contract lengths between CHP owners and grid operators, improved market designs, and simplified interconnection standards.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance analysis of hybrid power configurations: Impact on primary energy intensity, carbon dioxide emissions, and life cycle costs

In this work, utilization of Natural gas and Hydrogen to support current and future building energy needs to offset the total electric demand while improving the grid resiliency and energy efficiency was investigated. Demand side energy management will play an important role in efficiently managing the available energy resources. Performance assessment of different power generation and energy management configurations is presented in this paper. Development of solutions in addressing grid resiliency by providing the ability to design suitable configurations for meeting individual building energy needs is discussed. Primary movers (PM) such as internal combustion engines (ICE) and fuel cells (FC) along with small scale auxiliary renewable energy source such as photovoltaics (PV) were considered. Key attributes of total carbon foot-print, life cycle costs including capital and operational expenditure, electric grid offset or peak shaving capability, thermal energy availability and its further potential to offset total electric demand, and primary energy intensity are analyzed and discussed in detail.

08 HYDROGEN↗

Simulation of a photovoltaic/thermal heat pump system having a modified collector/evaporator

A new photovoltaic/thermal heat pump (PV/T-HP) system having a modified collector/evaporator (C/E) has been developed and numerically studied. Multi-port flat extruded aluminum tubes were used in the modified C/E, as compared to round copper tubes used in a conventional C/E. Simulation results suggested that a better operating performance can be achieved for a PV/T-HP system having such a modified C/E. In addition, using the meteorological data in both Nanjing and Hong Kong, China, the simulation results showed that this new PV/T-HP system could efficiently generate electricity and thermal energy simultaneously in both cities all-year-round. Furthermore, improved operation by using variable speed compressor has been designed and discussed. (author)

14 SOLAR ENERGY↗

Energy and cost analysis of a solar-hydrogen combined heat and power system for remote power supply using a computer simulation

A simulation program, based on Visual Pascal, for sizing and techno-economic analysis of the performance of solar-hydrogen combined heat and power systems for remote applications is described. The accuracy of the submodels is checked by comparing the real performances of the system's components obtained from experimental measurements with model outputs. The use of the heat generated by the PEM fuel cell, and any unused excess hydrogen, is investigated for hot water production or space heating while the solar-hydrogen system is supplying electricity. A 5 kWh daily demand profile and the solar radiation profile of Melbourne have been used in a case study to investigate the typical techno-economic characteristics of the system to supply a remote household. The simulation shows that by harnessing both thermal load and excess hydrogen it is possible to increase the average yearly energy efficiency of the fuel cell in the solar-hydrogen system from just below 40% up to about 80% in both heat and power generation (based on the high heating value of hydrogen). The fuel cell in the system is conventionally sized to meet the peak of the demand profile. However, an economic optimisation analysis illustrates that installing a larger fuel cell could lead to up to a 15% reduction in the unit cost of the electricity to an average of just below 90 c/kWh over the assessment period of 30 years. Further, for an economically optimal size of the fuel cell, nearly a half the yearly energy demand for hot water of the remote household could be supplied by heat recovery from the fuel cell and utilising unused hydrogen in the exit stream. Such a system could then complement a conventional solar water heating system by providing the boosting energy (usually in the order of 40% of the total) normally obtained from gas or electricity. (author)

14 SOLAR ENERGY↗