Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMMERCIAL SECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The Role of Energy Storage in Commercial Building

Motivation and Background of Study This project was motivated by the need to understand the full value of energy storage (thermal and electric energy storage) in commercial buildings, the opportunity of benefits for building operations and the potential interactions between a building and a smart grid infrastructure. On-site or local energy storage systems are not new to the commercial building sector; they have been in place in US buildings for decades. Most building-scale storage technologies are based on thermal or electrochemical storage mechanisms. Energy storage technologies are not designed to conserve energy, and losses associated with energy conversion are inevitable. Instead, storage provides flexibility to manage load in a building or to balance load and generation in the power grid. From the building owner's perspective, storage enables load shifting to optimize energy costs while maintaining comfort. From a grid operations perspective, building storage at scale could provide additional flexibility to grid operators in managing the generation variability from intermittent renewable energy resources (wind and solar). To characterize the set of benefits, technical opportunities and challenges, and potential economic values of storage in a commercial building from both the building operation's and the grid operation's view-points is the key point of this project. The research effort was initiated in early 2010 involving Argonne National Laboratory (ANL), the National Renewable Energy Laboratory (NREL), and Pacific Northwest National Laboratory (PNNL) to quantify these opportunities from a commercial buildings perspective. This report summarizes the early discussions, literature reviews, stakeholder engagements, and initial results of analyses related to the overall role of energy storage in commercial buildings. Beyond the summary of roughly eight months of effort by the laboratories, the report attempts to substantiate the importance of active DOE/BTP R&D activities in this space.

14 SOLAR ENERGY↗

Software-Defined Solutions for Managing Energy Use in Small to Medium Sized Commercial Buildings

The Project uses state-of-the-art computer science to extend the benefits of Building Automation Systems (BAS) typically found in large buildings (>100,000 square foot) to medium-sized commercial buildings (<50,000 sq ft). The BAS developed in this project, termed OpenBAS, uses an open-source and open software architecture platform, user interface, and plug-and-play control devices to facilitate adoption of energy efficiency strategies in the commercial building sector throughout the United States. At the heart of this “turn key” BAS is the platform with three types of controllers—thermostat, lighting controller, and general controller—that are easily “discovered” by the platform in a plug-and-play fashion. The user interface showcases the platform and provides the control system set-up, system status display and means of automatically mapping the control points in the system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Building Energy Asset Rating Program -- Market Research

Under contract to Pacific Northwest National Laboratory, HaydenTanner, LLC conducted an in-depth analysis of the potential market value of a commercial building energy asset rating program for the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy. The market research objectives were to: (1) Evaluate market interest and need for a program and tool to offer asset rating and rapidly identify potential energy efficiency measures for the commercial building sector. (2) Identify key input variables and asset rating outputs that would facilitate increased investment in energy efficiency. (3) Assess best practices and lessons learned from existing national and international energy rating programs. (4) Identify core messaging to motivate owners, investors, financiers, and others in the real estate sector to adopt a voluntary asset rating program and, as a consequence, deploy high-performance strategies and technologies across new and existing buildings. (5) Identify leverage factors and incentives that facilitate increased investment in these buildings. To meet these objectives, work consisted of a review of the relevant literature, examination of existing and emergent asset and operational rating systems, interviews with industry stakeholders, and an evaluation of the value implication of an asset label on asset valuation. This report documents the analysis methodology and findings, conclusion, and recommendations. Its intent is to support and inform the DOE Office of Energy Efficiency and Renewable Energy on the market need and potential value impacts of an asset labeling and diagnostic tool to encourage high-performance new buildings and building efficiency retrofit projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Impact Illinois (Final Technical Report)

Energy Impact Illinois (EI2) is an alliance of government organizations, nonprofits, and regional utility companies led by the Chicago Metropolitan Agency for Planning (CMAP) that is dedicated to helping communities in the Chicago metropolitan area become more energy efficient. Originally organized as the Chicago Region Retrofit Ramp-Up (CR3), EI2 became part of the nationwide Better Buildings Neighborhood Program (BBNP) in May 2010 after receiving a $25 million award from the U.S. Department of Energy (DOE) authorized through the American Recovery and Reinvestment Act of 2009 (ARRA). The program’s primary goal was to fund initiatives that mitigate barriers to energy efficiency retrofitting activities across residential, multifamily, and commercial building sectors in the seven-county CMAP region and to help to build a sustainable energy efficiency marketplace. The EI2 Final Technical Report provides a detailed review of the strategies, implementation methods, challenges, lessons learned, and final results of the EI2 program during the initial grant period from 2010-2013. During the program period, EI2 successfully increased direct retrofit activity in the region and was able to make a broader impact on the energy efficiency market in the Chicago region. As the period of performance for the initial grant comes to an end, EI2’s legacy raises the bar for the region in terms of helping homeowners and building owners to take action on the continually complex issue of energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative study of plutonium burning in heavy and light water reactors.

There is interest in the U.S. and world-wide in reducing the burden on geological nuclear fuel disposal sites. In some disposal scenarios, the decay heat loading of the surrounding rock limits the commercial spent fuel capacity of the sites. In the long term (100 to 1,500 years), this decay heat is generated primarily by actinides, particularly {sup 241}Am and {sup 241}Pu. One possible approach to reducing this decay-heat burden would be to reprocess commercial spent nuclear fuel and use intermediate-tier thermal reactors to 'burn' these actinides and other transuranics (plutonium and higher actinides). The viability of this approach is dependent on the detailed changes in chemical and isotopic compositions of actinide-bearing fuels after irradiation in thermal reactor spectra. The intermediate-tier thermal burners could bridge the commercial water-cooled reactors and fast reactors required for ultimate consumption of the transuranics generated in the commercial reactors. This would reduce the number of such fast reactors required to complete the mission of burning transuranics. If thermal systems are to be used for the transmutation mission, it is likely that they would be similar to or are advanced versions of the systems currently used for power generation. In both the U.S. and Canada, light- and heavy-water-cooled thermal reactors are used for power generation in the commercial nuclear sector. About 103 pressurized- and boiling- light water reactors (PWRs and BRWs) are deployed in the U.S. nuclear industry while about 18 CANDU (heavy-water-cooled) reactors are used in the Canadian industry. There are substantial differences between light and heavy water-cooled reactors that might affect transmutation potential. These arise from differences in neutron balance of the reactors, in neutron energy spectra, in operational approaches (e.g., continuous refueling enhancing fuel burnup), and so on. A systematic study has been conducted to compare the transmutation potentials of CANDU and PWR systems using (U,Pu)O{sub 2} mixed oxide fuels. First, we examine and compare the isotopic evolution of plutonium-containing fuel under irradiation in these reactor types to understand the physics processes involved. The core-physics parameters to be compared for these systems are generated using two-dimensional lattice physics models for a single fuel assembly that is representative of the whole-core (e.g., using the linear reactivity model). Results from a parametric study of the discharge burnup as a function of the Pu fraction in the initial heavy metal are presented for each system. The Pu consumption level, minor actinides buildup level, and the masses destroyed per unit energy generation are summarized and compared. In addition, assessment results for a simple plutonium recycling concept in realistic CANDU and PWR cores are presented. In these cases, plutonium from commercial spent PWR fuel will be separated and burned in realistic intermediate thermal burner reactors using (U,Pu)O{sub 2} mixed oxide fuel. The spent fuel from this thermal burner will be separated and the resulting Pu will be burned in a second pass through the thermal burner reactor. The resulting transuranics are assumed to then be burned in a fast burner reactor. The impact of using the spent fuels of these systems on the core performance of the fast burner reactor and the required numbers of the various reactor types will be discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Financial and economic determinants of collective action: The case of wastewater management

Where public environmental funds support development of wastewater infrastructure, funding institutions ensure the economic use of funds, while the beneficiaries minimize their own costs. In rural areas, there is often a choice between decentralized or centralized (multi-village) systems: if the centralized system is most economic, then only this system is eligible for public funding. However, its implementation requires a voluntary cooperation of the concerned communities, who need to organize themselves to develop and run the infrastructure. The paper analyzes the social determinants of collaboration in a generic case study, using the following variables: method of (economic) assessment, modeled by the social discount rate, funding policy, modeled by the funding rate, and users' self-organization, modeled by cost sharing. In a borderline situation, where the centralized system turns out to be most economic, but this assessment is contingent on the assessment method, collective action may fail: the advantages of collective action from funding are too small to outweigh organizational deficiencies. Considering in this situation sanitation as a human right, authors recommend using innovative forms of organization and, if these fail, reassessing either the amount of funding or the eligibility for funding of more acceptable alternatives. - Highlights: Black-Right-Pointing-Pointer A generic case study models collective action and funding in wastewater management. Black-Right-Pointing-Pointer Determinants of success: economic assessment, funding policy and self-organization. Black-Right-Pointing-Pointer Success indicators: conflict rate, funds needed to make cost shares fair. Black-Right-Pointing-Pointer Method for analyzing centralized vs. decentralized disputes. Black-Right-Pointing-Pointer If collective action has less benefits, innovative cost sharing may ensure success.

54 ENVIRONMENTAL SCIENCES↗

Predicting the quantifiable impacts of ISO 50001 on climate change mitigation

The ISO 50001-Energy management standard provides a continual improvement framework for organizations to reduce their energy consumption, which in the industrial and commercial (service) sectors, accounts for nearly 40% of global greenhouse gas emissions. Reducing this energy consumption will be critical for countries to achieve their national greenhouse gas reduction commitments. Several national policies already support ISO 50001; however, there is no transparent, consistent process to estimate the potential impacts of its implementation. This paper presents the ISO 50001 Impacts Methodology, an internationally-developed methodology to calculate these impacts at a national, regional, or global scale suitable for use by policymakers. The recently-formed ISO 50001 Global Impacts Research Network provides a forum for policymakers to refine and encourage use of the methodology. Using this methodology, a scenario with 50% of projected global industrial and service sector energy consumption under ISO 50001 management by 2030 would generate cumulative primary energy savings of approximately 105 EJ, cost savings of nearly US $700 billion (discounted to 2016 net present value), and 6500 million metric tons (Mt) of avoided CO 2 emissions. The avoided annual CO 2 emissions in 2030 alone are equivalent to removing 210 million passenger vehicles from the road.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The human dimensions of energy use in buildings: A review

The “human dimensions” of energy use in buildings refer to the energy-related behaviors of key stakeholders that affect energy use over the building life cycle. Stakeholders include building designers, operators, managers, engineers, occupants, industry, vendors, and policymakers, who directly or indirectly influence the acts of designing, constructing, living, operating, managing, and regulating the built environments, from individual building up to the urban scale. Among factors driving high-performance buildings, human dimensions play a role that is as significant as that of technological advances. However, this factor is not well understood, and, as a result, human dimensions are often ignored or simplified by stakeholders. This work presents a review of the literature on human dimensions of building energy use to assess the state-of-the-art in this topic area. The paper highlights research needs for fully integrating human dimensions into the building design and operation processes with the goal of reducing energy use in buildings while enhancing occupant comfort and productivity. This research focuses on identifying key needs for each stakeholder involved in a building's life cycle and takes an interdisciplinary focus that spans the fields of architecture and engineering design, sociology, data science, energy policy, codes, and standards to provide targeted insights. Greater understanding of the human dimensions of energy use has several potential benefits including reductions in operating cost for building owners; enhanced comfort conditions and productivity for building occupants; more effective building energy management and automation systems for building operators and energy managers; and the integration of more accurate control logic into the next generation of human-in-the-loop technologies. The review concludes by summarizing recommendations for policy makers and industry stakeholders for developing codes, standards, and technologies that can leverage the human dimensions of energy use to reliably predict and achieve energy use reductions in the residential and commercial buildings sectors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The practical equity implications of advanced metering infrastructure

Reductions in advanced metering costs and the efficiency benefits of dynamic pricing make a compelling case to adopt both, particularly for industrial and commercial facilities. Regulators should seriously consider such policies for residential households as well. Regulators can take meaningful steps to mitigate, if not entirely offset, the possibility that some low-income ratepayers may have higher electricity bills with AM and DP. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Delivering energy savings through community-based Organizations

To achieve greater energy savings through energy efficiency programs, participation in those programs must increase. Community-based organizations provide a potentially effective way to reach more residential and small commercial consumers and increase the adoption of energy efficiency measures. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Estimating the Benefits of Sustainable Aviation Fuel Usage at Chicago O’Hare International Airport on Ultrafine Particle Exposure and Mortalities Reductions

The expanding commercial aviation sector necessitates diverse energy sources, and sustainable aviation fuels (SAFs) have emerged as a promising option. Widespread SAF adoption can help meet transportation fuel demand and offer health benefits for people residing near airports or along airport landing and takeoff (LTO) pathways, where elevated levels of aircraft-derived air pollution often exist. Blending SAF with traditional jet fuels can reduce ultrafine particle (UFP) emissions, which may improve health of near airport population. We analyzed a population of about 8 million people in 1925 census tracts around the Chicago O’Hare International Airport (ORD). We conducted a risk assessment to estimate anticipated UFP reductions for three adoption scenarios using blends of traditional jet fuels with 5, 25, and 50% SAF across all flights landing and taking off from ORD. We calculated baseline estimates of UFP emissions using ORD flight data, a dispersion model, and a calibration function derived from mobile monitoring data. We used this baseline UFP emission profile across the study area to estimate population-weighted UFP, as well as the attributable case reductions (ACRs) and attributable mortality rate reductions (AMRRs) across the demographic distribution around the airport, based on the SAF blending scenarios. We found a positive association of SAF blending with UFP reductions, particularly near the airport and along LTO flight pathways. Our study showed that the population-weighted UFP across different demographics was similar. ACRs were largely dependent on individual demographic populations, while AMRRs for all populations were relatively similar, with an estimated 0.3 (95% range: 0.2−0.3), 1.1 (0.9−1.4), and 1.8 (1.5−2.2) fewer mortalities per 100,000 people per year expected with the adoption of 5, 25, and 50% SAF blends, respectively. This study indicates that communities near ORD, across a range of demographics, may benefit similarly from SAF adoption, thus highlighting how SAF adoption may offer an opportunity to improve health outcomes like aviation UFP-related mortalities around airports.

10 SYNTHETIC FUELS↗

Future Roles for Nuclear Energy

An introduction to the operation of nuclear fission reactors, current status of the commercial nuclear sector, expansion opportunities, and research and development priorities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Updated U.S. Low-Temperature Heating and Cooling Demand by County and Sector

This dataset includes U.S. low-temperature heating and cooling demand at the county level in major end-use sectors: residential, commercial, manufacturing, agricultural, and data centers. Census division-level end-use energy consumption, expenditure, and commissioned power database were dis-aggregated to the county level. The county-level database was incorporated with climate zone, numbers of housing units and farms, farm size, and coefficient of performance (COP) for heating and cooling demand analysis. This dataset also includes a paper containing a full explanation of the methodologies used and maps. Residential data were updated from the latest Residential Energy Consumption Survey (RECS) dataset (2015) using 2020 census data. Commercial data were baselined off the latest Commercial Building Energy Consumption Survey (CBECS) dataset (2012). Manufacturing data were baselined off the latest Manufacturing Energy Consumption Survey (MECS) dataset (2021).

15 GEOTHERMAL ENERGY↗

Pathways for Disposal of Commercially-Generated Tritiated Waste

From a waste disposal standpoint, tritium is a major challenge. Because it behaves like hydrogen, tritium exchanges readily with hydrogen in the ground water and moves easily through the ground. Land disposal sites must control the tritium activity and mobility of incoming wastes to protect human health and the environment. Consequently, disposal of tritiated low-level wastes is highly regulated and disposal options are limited. The United States has had eight operating commercial facilities licensed for low-level radioactive waste disposal, only four of which are currently receiving waste. Each of these is licensed and regulated by its state. Only two of these sites accept waste from states outside of their specified regional compact. For waste streams that cannot be disposed directly at one of the four active commercial low-level waste disposal facilities, processing facilities offer various forms of tritiated low-level waste processing and treatment, and then transport and dispose of the residuals at a disposal facility. These processing facilities may remove and recycle tritium, reduce waste volume, solidify liquid waste, remove hazardous constituents, or perform a number of additional treatments. Waste brokers also offer many low-level and mixed waste management and transportation services. These services can be especially helpful for small-quantity tritiated-waste generators, such as universities, research institutions, medical facilities, and some industries. The information contained in this report covers general capabilities and requirements for the various disposal/processing facilities and brokerage companies, but is not considered exhaustive. Typically, each facility has extensive waste acceptance criteria and will require a generator to thoroughly characterize their wastes. Then a contractual agreement between the waste generator and the disposal/processing/broker entity must be in place before waste is accepted. Costs for tritiated waste transportation, processing and disposal vary based a number of factors. In many cases, wastes with very low radioactivity are priced primarily based on weight or volume. For higher activities, costs are based on both volume and activity, with the activity-based charges usually being much larger than volume-based charges. Other factors affecting cost include location, waste classification and form, other hazards in the waste, etc. Costs may be based on general guidelines used by an individual disposal or processing site, but final costs are established by specific contract with each generator. For this report, seven hypothetical waste streams intended to represent commercially-generated tritiated waste were defined in order to calculate comparative costs. Ballpark costs for disposition of these hypothetical waste streams were calculated. These costs ranged from thousands to millions of dollars. Due to the complexity of the cost-determining factors mentioned above, the costs calculated in this report should be understood to represent very rough cost estimates for the various hypothetical wastes. Actual costs could be higher or could be lower due to quantity discounts or other factors.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration of Micro-Combined Heat and Power for Light Commercial Applications (Final Report)

In 2014 the United States Department of Energy (DOE) Building Technologies Office (BTO) funded a technology assessment of micro Combined Heat and Power (µCHP) systems for light commercial applications. The technology assessment was part of the BTO High Impact Technology (HIT) Catalyst program. The HIT Catalyst program supports research and development into technologies that will yield cost-effective, efficient buildings. It is estimated µCHP in US has the potential to save 10.5 GW of primary energy in the commercial building sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Air- and Water-Resistive Barriers -– Technology Verification

Infiltration and exfiltration are among the largest envelope-related contributors to the heating, ventilation, and air conditioning (HVAC) loads in commercial buildings. Air leakage is responsible for about 6% of the total energy used by the commercial building sector. New air sealing technologies have recently emerged that aim to improve the performance of air barrier systems by simplifying their installation procedure. These include the 3M 3015 primer-less self-adhered membrane, 3M 3015VP vapor permeable primer-less self-adhered membrane, and 3M 2085VP vapor permeable fluid-applied air barrier membrane. ORNL verified the performance of the 3M 3015, 3015VP and 2085VP air- and water- resistive barriers by conducting two field studies. The first one involved side-by-side evaluations in eight unoccupied test facilities in Cottage Grove, MN, that included the 3M membranes and commonly used air barrier materials such as a self-adhered membrane with primer and a mechanically-fastened membrane with taped joints. The facilities were monitored for 24 months and the collected data were used to calibrate simulation models that in turn were employed to calculate energy consumption and savings because of improvements in airtightness. After two years, results indicate that the test facilities with the new 3M technologies had leakage rates that were slightly lower than the buildings with traditional air barrier materials. The calibrated model for the test facility with the 3M 3015 membrane was used to calculate energy savings due to improved airtightness when compared to a building without an air barrier. Findings suggest that a building in Minneapolis, MN, or Fairbanks, AK, that has a properly installed air barrier system can have annual HVAC electricity use that is about 36% lower than if the building did not have an air barrier. Similarly, decreases in natural gas use can be about 25%. The second field evaluation involved the LifeSource building in Minneapolis, MN, and the Sierra Trading Post building in Woodbury, MN. Both of these were recently completed and use the 3M 3015 and 3015VP membranes as their air- and water- resistive barriers, respectively. Blower door test results show that LifeSource has an average air leakage rate of 0.06 cfm/ft 2 at 75 Pa, or 85% lower than the 0.4 cfm/ft 2 at 75 Pa specified in the 2015 International Energy Conservation Code (IECC). The leakage rate in the Sierra building is 0.15 cfm/ft 2 at 75 Pa or 63% than the IECC value. According to simulation results, LifeSource lowered its annual heating and cooling cost by about $\$$4600 or 10% when compared to a similar building that lacked an air barrier system. In the case of the Sierra building, savings were $5,900 or 41%. These field evaluations serve as examples of the level of building envelope airtightness that can be achieved by using air barrier materials that are properly installed, and illustrate the energy and financial savings that building envelopes with low air leakage rates could attain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Business Case Analysis for Digital Safety-Related Instrumentation & Control System Modernizations

The commercial nuclear sector faces unprecedented financial challenges driven by low natural gas prices and subsidized renewables in a marketplace that does not reward carbon-free baseload capacity. These circumstances, along with increasingly antiquated labor-centric operating models and analog technology, have forced the premature closure of multiple nuclear facilities and placed a much larger population of nuclear power stations at risk. Nuclear plant economic survival in current and forecasted market conditions requires an efficient and technology-centric operating model that harvests the native efficiencies of advanced technology. This is analogous to transformations in nearly every other industry. In light of previous industry experience in modernizing safety Instrumentation and Controls (I&C) systems, nuclear utilities are reluctant to pursue these upgrades due to uncertainty in licensing and cost.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Direct Air Capture of CO2 (DAC) [Tech Snapshot]

Researchers at Los Alamos have extensive capabilities in design, testing and optimization of: (1) new capture materials based on membrane separation, amine and other solvent and sorbent separation, and porous materials; (2) biological capture methods, particularly algae and plants; (3) full-scale systems using science-based virtual learning; and (4) system performance under specific meteorological conditions, impacts of CO2 capture via atmospheric data and simulations, and availability of energy and storage capacity. The goal for Los Alamos is advancing our physical technologies and engineered systems approaches from the development phase to a minimal viable product in the energy sector for commercial purposes. Los Alamos is seeking strategic commercialization partners to work with us in advancing these capabilities and technologies for commercial viability.

54 ENVIRONMENTAL SCIENCES↗