Post-Transient Examination Results of RIA Commissioning Teats at the Transient Reactor Test Facility
Six reactivity-initiated-accident (RIA) commissioning tests have been performed at Idaho National Laboratory’s (INL) Transient Reactor Test Facility. Five of these tests were performed using fresh fuel rodlets, and the sixth test was performed using a previously irradiated rodlet from the ATF-2 irradiation experiment. These experiments demonstrate the ability to perform RIA testing including the ability to perform experiments using previously irradiated materials. Post-transient examinations revealed pellet cladding interactions and cladding ballooning depending on the initial boundary conditions of the test. Increased thickness of both zirconium oxide and alpha-zirconium were found in the cladding with tests performed at higher levels of total energy deposition. No oxide or alpha-zirconium was found in the test with the greatest amount of ballooning, which was also the test with the highest initial rod internal pressure. The highest energy deposition test (1110 J/g) resulted in failure of the rodlet. Fragmentation of the fuel pellets occurred in this test with the size of the fragments decreasing inversely to the pellet radius.