At least 199 records · Page 11

Xe Concentration Activity

INL conducted extensive studies to understand how the Xe capacity of AgZ-PAN changes under various conditions including flowrate, temperature, concentration, carrier gas, and irradiation of the sorbent. Therefore, it is well understood that AgZ-PAN can capture Xe under a wide range of conditions. While these studies were performed to prove that Xe can be completely desorbed from the column, the ability to concentrate Xe during desorption was not studied. Concentrating Xe during desorption would be ideal so as to produce Xe that can be used for commercial and research applications. This report investigates the Xe concentrating potential of AgZ-PAN by running multiple Xe adsorption-desorption cycles, collecting the desorbed effluent from a saturated AgZ-PAN column, and then loading it onto a fresh column.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis and Optimization of a Novel Hexagonal Waveguide Concentrator for Solar Thermal Applications

This paper analyzes a novel, cost-effective planar waveguide solar concentrator design that is inspired by cellular hexagonal structures in nature with the benefits of facile installation and low operation and maintenance cost. A coupled thermal and optical analysis of solar irradiation through an ideal hexagonal waveguide concentrator integrated with a linear receiver is presented, along with a cost analysis methodology, to establish the upper limit of performance. The techno-economic model, coupled with numerical optimization, is used to determine designs that maximized power density and minimized the cost of heat in the temperature range of 100–250 °C, which constitutes more than half of the industrial process heat demand. Depending on the incident solar irradiation and the application temperature, the cost of heat for the optimal design configuration ranged between 0.1–0.27 $/W and 0.075–0.18 $/W for waveguide made of ZK7 glass and polycarbonate, respectively. A techno-economic analysis showed the potential of the technology to achieve cost as low as 80 $/m2 and 61 $/m2 for waveguide made of ZK7 glass and polycarbonate material, respectively, which is less than half the cost of state-of-the-art parabolic trough concentrators. Overall, the hexagonal waveguide solar concentrator technology shows immense potential for decarbonizing the industrial process heat and thermal desalination sectors.

14 SOLAR ENERGY↗

Ice nucleating particle concentrations measured by the CSU-CFDC during the AGINSGP field experiment

Real-time, immersion mode ambient ice nucleating particle (INP) concentrations were measured at ARM&rsquo;s Southern Great Plains (SGP) site during the AGINSGP field experiment using a continuous flow diffusion chamber (CFDC) from Colorado State University (CSU). The CSU-CFDC is an ice-thermal gradient diffusion chamber that optically detects the freezing of single aerosol particles (Rogers 1988; Rogers et al. 2001; and Eidhammer et al. 2010). The instrument was located in the guest instrument facility (GIF) and measured INP concentrations from April 8th to April 29th. Air was drawn into the GIF through custom aluminum stack inlets (6&rdquo; inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8&rdquo; or 1/4" copper lines, depending on sample flow of the instrument. Rogers, D. C., Development of a continuous flow thermal gradient diffusion chamber for ice nucleation studies, Atmospheric Research, 22(2), 149-181, doi:10.1016/0169-8095(88)90005-1, 1988. Rogers, D. C., P. J. DeMott, S. M. Kreidenweis and Y. Chen, A continuous flow diffusion chamber for airborne measurements of ice nuclei, J. Atmos. Oceanic Technol., 18, 725-741, doi:10.1175/1520-0426(2001)018<0725:ACFDCF>2.0.CO;2, 2001. Eidhammer, T., DeMott, P. J., Prenni, A. J., Petters, M. D., Twohy, C. H., Rogers, D. C., Stith, J., Heymsfield, A., Wang, Z., Haimov, S., French, J., Pratt, K., Prather, K., Murphy, S., Seinfeld, J., Subramanian, R., and Kreidenweis, S. M., Ice initiation by aerosol particles: Measured and predicted ice nuclei concentrations versus measured ice crystal concentrations in an orographic wave cloud, J. Atmos. Sci., 67, 2417-2436, doi:10.1175/2010JAS3266.1, 2010

54 ENVIRONMENTAL SCIENCES↗

Electrochemical Impedance Spectroscopy and Cyclic Voltammetry Methods for Monitoring SmCl 3 Concentration in Molten Eutectic LiCl-KCl

Molten salt solutions consisting of eutectic LiCl-KCl and concentrations of samarium chloride (0.5 to 3.0 wt%) at 500 C were analyzed using both cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The CV technique gave the average diffusion coefficient for Sm 3+ over the concentration range. Equipped with Sm 3+ diffusion coefficient, the Randles-Sevcik equation predicted Sm 3+ concentration values that agree with the given experimental values. From CV measurements; the anodic, cathodic, and half-peak potentials were identified and subsequently used as a parameter to acquire EIS spectra. A six-element Voigt model was used to model the EIS data in terms of resistance-time constant pairs. The lowest resistances were observed at the half-peak potential with the associated resistance-time constant pairs characterizing the reversible reaction between Sm 3+ and Sm 2+ . By extrapolation, the Voigt model estimated the polarization resistance and established a polarization resistance-concentration relationship.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

VENTSAR V3.0: A Python GUI for Estimating Contaminant Concentrations on or Near Buildings Due to Building Effects and Plume Rise and For Calculating Inhalation and Plume Shine Doses

VENTSAR: Originated as VENTAX (Smith and Weber 1983) on the IBM Mainframe at the Savannah River Site (SRS) as a Fortran program. Updated to VENTSAR XL V1.0 (Simpkins 1997) as a spreadsheet version using macros created in Microsoft Excel. Later updated to VENTSAR XL V2.0 (Dixon 2018) as a spreadsheet executing a modified version of the original VENTAX Fortran code. Estimates contaminant concentrations on or near a building from a release at a nearby location. Calculates concentrations for a given meteorological exceedance probability or for a given stability and wind speed combination. Can model a single building with or without a penthouse on top or a ground location from either a stack or ground release. Plume rise can be considered. Contaminant releases can be chemical or radioactive with downwind concentrations determined at user-specified distances. Wind passing over and around buildings creates a complicated dispersion pattern. Air-intake vents may be located on building roofs or near the ground downwind of a release source. An estimation of pollutant concentrations on or near a structure is important in determining expected pollutant levels. Meteorological data are selected based on a specific area of the site. Fortran-based VENTAX able to make fast, complex mathematical calculations. Not user-friendly VENTSAR XL V1.0 no longer supported due to obsolete Excel macros. VENTSAR XL V2.0 an interim solution using an Excel spreadsheet to interface with the modified VENTAX Fortran code. Requires user to have Microsoft Excel. Not an intuitive interface for someone unfamiliar with VENTSAR. Does not perform dose calculations. VENTSAR V3.0 goal to combine the strengths of previous versions of VENTSAR into a single, powerful yet user-friendly program with a Graphical User Interface (GUI). Not dependent upon a specific program or plug-ins. Self-contained package to be used on any computer running Microsoft Windows. User-friendly, intuitive GUI created in Python for parameter input. Executes same modified VENTAX Fortran code as VENTSAR XL V2.0. Outputs formatted text file of completed calculations for easy review and dissemination. Performs inhalation and plume shine dose calculations for up to 11 user-selected nuclides from a nuclide dose factor library of almost 500 nuclides. 12 test cases were created for verification of V1.0 and V2.0. Same test cases run in V3.0 to verify correct performance. V3.0 produced similar results to V1.0. Confirmed GUI did not alter calculations in any way. Comparisons of the test case results confirm the V3.0 GUI does not influence the VENTSAR calculations. Simply passes same input parameters to VENTAX Fortran code for execution. Provides end user an easy-to-use, intuitive tool to quickly make building effect and plume rise calculations, as well as, inhalation and plume shine dose calculations. No experience with or working knowledge of Fortran, Excel, command line, or macros required. Self-contained package allows VENTSAR be deployed to any Windows computer without the need for specific programs or plug-ins.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low Level Radon Concentration and Radon Daughter Dose Monitoring in an Arid-zone Waste Store - 20081

Radioactive waste containing predominantly soil and rubble from the clean-up of a former uranium and thorium minerals processing research facility is currently stored at the Woomera Test Range in South Australia awaiting final disposal. Prior to commencing any manipulation of the nearly 10,000 waste drums (205 L or 55 gallon each), radon concentration monitoring and radon daughter dosimetry has been undertaken to (i) gain understanding of the temporal and spatial variation of radon and its daughters within the storage facility, which could provide insights into the radiological source term and (ii) confirm that radiological risks to workers are below the guideline values. A time series of nearly 12 months of detailed observations shows low level radon concentrations with annual average values that are slightly above the average radon concentrations in Australian homes. Peak values in summer are about three times higher than the annual average based on the CRM measurements. Both radon concentrations and annual effective dose are well below the regulatory limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Meteorological Conditions and Atmospheric Components Concentration in Urban Sites in Knoxville, USA. 2024

This dataset, which contains five csv files, reports several meteorological conditions such as temperature, wind speed, solar radiation, and net radiation measured in Cumberland Estates Park (CEP) and Socially Equal Energy Efficient Development (SEEED) sites in Knoxville, Tennessee, USA. Also, hourly concentration of particulate matter (PM) with different aerodynamic diameter and inorganic gases such as ozone and nitrogen dioxide measured in the two are included in this dataset. The concentrations of PM and inorganic gases were monitored using the MODULAIR, a low-cost sensor equipped with a solar power module. The measurement of the concentration of biogenic and anthropogenic volatile organic compounds (VOCs) of the two sites was determined using a High-Resolution Proton Transfer Reaction Time of Flight Mass Spectrometer (PTR-ToF-MS). The VOCs were collected using miniature canister (400 mL) equipped with female RAVEqc valve to 1/4” male compression fitting and an integrated passive air sampling kit. This work is a part of a larger study which investigates the impact of soil moisture and plant evapotranspiration on ambient temperature and relative humidity in several city parks in Knoxville, Tennessee.

54 ENVIRONMENTAL SCIENCES↗

Concentration‐dependent Cycling of Phenothiazine‐based Electrolytes in Nonaqueous Redox Flow Cells

Increasing redox-active species concentrations can improve viability for organic redox flow batteries by enabling higher energy densities, but the required concentrated solutions can become viscous and less conductive, leading to inefficient electrochemical cycling and low material utilization at higher current densities. To better understand these tradeoffs in a model system, we study a highly soluble and stable redox-active couple, N-(2-(2-methoxyethoxy)ethyl)phenothiazine (MEEPT), and its bis(trifluoromethanesulfonyl)imide radical cation salt (MEEPT-TFSI). We measure the physicochemical properties of electrolytes containing 0.2–1 M active species and connect these to symmetric cell cycling behavior, achieving robust cycling performance. Specifically, for a 1 M electrolyte concentration, we demonstrate 94% materials utilization, 89% capacity retention, and 99.8% average coulombic efficiency over 435 h (100 full cycles). This demonstration helps to establish potential for high-performing, concentrated nonaqueous electrolytes and highlights possible failure modes in such systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of gel concentration on filter fluxes in microfiltration of Hanford tank wastes and simulants

Abstract Treatment processes have been proposed that will utilize crossflow filtration to concentrate sludge waste streams at the Department of Energy's Hanford Site. Challenges associated with solid–liquid separation of the waste streams drive a necessary evaluation of available Hanford high level waste (HLW) filtration data. Limiting flux conditions during crossflow filtration are elucidated with the formation of a cake layer on the membrane surface. A mass transfer coefficient between the gel and bulk concentrations plays a critical role in determining filter flux. A correlation between the gel concentration and mass transfer coefficient is made to assist in determining filter performance of select HLW streams. As a process alternative to crossflow filtration, gravity settling of waste streams may be deployed as a solid–liquid separation technique. However, this results in a contrasting performance with the centrifuged solids concentration. A method was developed to estimate expected filtration and settling performance based on physical characterization data for Hanford tank waste samples. By assessing the estimated processing performance of HLW, technical support can be provided during flowsheet planning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrating Mercury Concentrations in American Alligators ( Alligator mississippiensis ) with Hunter Consumption Surveys to Estimate Exposure Risk

Mercury is a naturally occurring element but is also considered a widespread contaminant due to global anthropogenic activity. Even in moderate amounts, mercury (Hg) is an established neurotoxin and is associated with a range of adverse outcomes both in humans and wildlife. Humans in the United States are most commonly exposed to Hg through contaminated food or drinking water, and the consumption of game species, particularly those occupying higher trophic levels, has the potential to expose hunters to high concentrations of Hg. In the present study, we determined Hg concentrations in tail muscle and blood from American alligators (Alligator mississippiensis) inhabiting a region (Savannah River Site, SC, USA) with known Hg contamination. We then integrated these data with alligator harvest records and previously published surveys of alligator meat consumption patterns to estimate potential exposure risk. We found that the average Hg concentrations in tail muscle (1.34 mg/kg, wet wt) from sampled alligators exceeded the recommended threshold for Hg exposure based on the World Health Organization's guidelines (0.5mg/kg, wet wt). In addition, based on regional consumption patterns reported for both adults and children, we estimated Hg exposures (x¯ Adult = 0.419 μg/kg/day, x¯ Child = 2.24 μg/kg/day) occurring well above the US Environmental Protection Agency methylmercury reference dose of 0.1 μg/kg/day. Although the two reservoirs sampled in the present study are not currently open to alligator hunting, they are connected to waters that are publicly accessible, and the extent of alligator mobility across these sites is not known. Together, the findings reported in the present study further demonstrate the need for active monitoring of Hg concentrations in game species, which can convey substantial exposure risks to the public.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molar Absorptivities of U(VI), U(IV), and Pu(III) in Nitric Acid Solutions of Various Concentrations Relevant to Developing Nuclear Fuel Recycling Flowsheets

Testing of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet is being performed to optimize conditions for achieving a target U/Pu ratio in the Pu-containing product. The flowsheet is designed to directly produce a mixture of U and Pu with a U/Pu mass ratio of 7/3. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio in the aqueous U/Pu nitrate product. On-line spectrophotometric monitoring of the aqueous stream at the reductive stripping step involves determination of U(VI), U(IV) and Pu(III) concentrations and relies on molar absorptivities of these species in nitric acid at a number of wavelengths corresponding to their peaks’ maxima. The magnitudes of these molar absorptivities are a sensitive function of nitric acid concentration and have to be determined as precisely as possible using an off-line spectrophotometry under well controlled conditions. This step (called training set acquisition) is typically performed not in a high contamination area of radiological glovebox where flow-through cells and other on-line equipment are installed but in a less aggressive environment of a radiological fume hood with much better control of stock solutions quality, dilution factors, optical absorbance scale calibration, etc. This is followed by the calibration transfer between the off-line instrument and the instrument deployed during extraction and stripping runs. This paper reports values of molar absorptivities of U(VI), U(IV), and Pu(III) in nitric acid solution of 0.5 M to 4 M concentration and compares them with available technical literature data. Results of off-line spectrophotometric analysis of selected aqueous grab samples from one of CoDCon runs show satisfactory agreement with total uranium and plutonium concentrations determined in the same samples by ICP-MS.

Sinkov, Sergey I.↗

Variation of the Passive Film on Compositionally Concentrated Dual-Phase Al 0.3 Cr 0.5 Fe 2 Mn 0.25 Mo 0.15 Ni 1.5 Ti 0.3 and Implications for Corrosion

The passive film on a dual-phase Al 0.3 Cr 0.5 Fe 2 Mn 0.25 Mo 0.15 Ni 1.5 Ti 0.3 FCC + Heusler (L2 1 ) compositionally concentrated alloy formed during extended exposure to an applied potential in the passive range in dilute chloride solution was characterized. Each phase, with its own distinct composition of passivating elements, formed unique passive films separated by a heterophase interface. High-resolution, surface sensitive characterization enabled chemical analysis of the passive film formed over individual phases. The film formed over the L2 1 phase had a higher concentration of Al, Ni, and Ti, while the film formed over FCC phase was of similar thickness but contained comparatively higher Cr, Fe, and Mo concentrations, consistent with the differences in bulk microstructure composition. The passive film was continuous across phase boundaries and the distribution of passivating elements (Al, Cr, and Ti) indicated both phases were independently passivated. Spatially resolved analysis of the surface chemistry of the dual-phase CCA revealed that the cation with the highest composition in passive film formed on the FCC phase was Cr (52.4 at. pct) and for the L2 1 phase was Ti (53.1 at. pct) despite the bulk concentration of each element being below 20 at. pct in their respective phases. Al, Cr, and Ti were enriched in both phases within the passive film relative to their respective bulk compositions. In parallel studies, single-phase alloys with compositions representative of the FCC and L2 1 phases were synthesized to evaluate the corrosion behavior of each phase in isolation. The corrosion behavior of the dual-phase alloy showed passivity evidenced by a pitting potential of 0.615 V SCE in 0.01 M NaCl. The pitting potential and other electrochemical parameters suggested a combination of behaviors of both single-phase samples, suggesting that the global corrosion behavior may be represented by a composite theory applied to phases, their area fractions, and interphase length. However, the interphase in the dual-phase CCA was a local corrosion initiation site and may limit localized corrosion protectiveness. The alloy design implications for optimization of second phase structure and morphology are discussed.

36 MATERIALS SCIENCE↗

Change of Electrical and Transport Properties of Nickel Oxide by Carrier Concentration and Temperature through First-Principle Calculations

Abstract Nickel is typically used as one of the main components in electrical contact devices or connectors. Nickel oxide (NiO) is usually formed on the surfaces of electrodes and can negatively impact system performance by introducing electrical contact resistance. The thermal, electrical, and transport properties of NiO, as a Mott insulator or a p-type semiconductor, can be altered by operating and environmental conditions such as temperature and stress/strain by contact. In this study, we investigate the fundamental material properties of NiO through the first-principle calculations. First, we obtain and compare the lattice parameter, magnetic moment, and electronic structure for NiO via the WIEN2K simulations with four different potentials (i.e., GGA, GGA + U, LSDA, and LSDA + U). Then, using the WIEN2K simulation results with LSDA + U potential that produces a highly accurate bandgap for NiO, we calculate the electrical conductivity and electrical part of the thermal conductivity of nickel and NiO as a function of temperature and carrier concentration through the BoltzTraP simulations. Systematic simulation results revealed that the electrical conductivity relative to the relaxation time for NiO increases with the carrier concentration, while it shows a slightly decreasing trend with temperature under a fixed carrier concentration. By contrast, the electrical part of the thermal conductivity shows an increasing trend considering carrier concentration and temperature.

Shah, Nayem Md. Reza↗

Experimental and numerical study of the effects of solution concentration and temperature on concrete under external sulfate attack

The work reports on an experimental programme, conducted to validate comprehensively our previously proposed coupled chemo-transport model for external sulfate attack on concrete. Specifically, the effects of the concentration of sulfate solution and temperature on the distribution of sulfate ions in concrete are experimentally investigated and used to demonstrate the accuracy of the modeling framework. Further, the profile of aluminate depletion and the leaching depth numerically are investigated. For all cases the model predictions are in good agreement with the experimental results, showing increases of the concentration of sulfate ions in concrete with higher concentrations of sulfate solution and higher temperatures. It is concluded that higher sulfate solution concentration and temperature enhance the processes involved in the external sulfate attack on concrete, namely diffusion of sulfate ions and their chemical reactions with concrete. It is found that these parameters affect the external sulfate attack predominantly via the chemical reaction process.

36 MATERIALS SCIENCE↗

The apparent reversal of the Law of Mass Action in concentrated multicomponent aqueous solutions

Although it is well known that aqueous electrolyte solutions behave non-ideally, few are so non-ideal that adding an electrolyte to a saturated solution with a common ion enhances rather than depresses solubility. Nonetheless, this apparent reversal of the Law of Mass Action (LMA) has been observed in simple nitrate solutions at high concentrations. A leading hypothesis is that ion clusters are formed and stabilized by ions having different charge densities. We report the present study examines this concept, in part by reviewing relevant data from multicomponent aqueous solutions containing sodium nitrate (NaNO 3 ), sodium nitrite (NaNO 2 ), sodium hydroxide (NaOH), and sodium aluminate (NaAl(OH) 4 ) - the major constituents in alkaline nuclear waste. Here, NaOH and NaAl(OH) 4 did not enhance the solubility of NaNO 3 or NaNO 2 , whereas NaNO 2 and NaNO 3 enhanced rather than depressed the solubility of each other despite each having the sodium cation (Na + ) in common. Solutions evaluated in this study have more than 20 molal total Na + concentration, and most have less than one mole of water per mole of ion. Thus, this reversal of the LMA occurs in solutions where there is not enough water to fully hydrate the ions, pointing to the importance of ion cluster formation. Within the composition range of the solutions analyzed here, this reversal of the LMA occurs regardless of NaAl(OH) 4 and NaOH concentrations. Elevated temperatures also result in the reversal of the LMA in the subsystems NaNO 2 -NaNO 3 -H 2 O and NaOH-NaNO 3 -H 2 O, consistent with spectroscopic and computational studies showing enhanced interactions at higher temperatures. Although speciation in these highly concentrated electrolyte solutions is not well understood, the stabilization of ion clusters by: (i) optimizing charge density around the ions through different combinations of mixed cations and anions in solution; and (ii) high temperatures where ions experience prolonged contact, offers important clues for future research into how these species control solubility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methane and nitrous oxide porewater concentrations and surface fluxes of a regulated river

Greenhouse gas (GHG) emissions from rivers are a critical missing component of current global GHG models. Their exclusion is mainly due to a lack of in-situ measurements and a poor understanding of the spatiotemporal dynamics of GHG production and emissions, which prevents optimal model parametrization. We combined simultaneous observations of porewater concentrations along different beach positions and depths, and surface fluxes of methane and nitrous oxide at a plot scale in a large regulated river during three water stages: rising, falling, and low. Our goal was to gain insights into the interactions between hydrological exchanges and GHG emissions and elucidate possible hypotheses that could guide future research on the mechanisms of GHG production, consumption, and transport in the hyporheic zone (HZ). Results indicate that the site functioned as a net source of methane. Surface fluxes of methane during river water stages at three beach positions (shallow intermediate and deep) correlated with porewater concentrations of methane. However, fluxes were significantly higher in the intermediate position during low water stage, suggesting that low residence time increased methane emissions. Vertical profiles of methane peaked at different depths, indicating an influence of the magnitude and direction of the hyporheic mixing during the different river water stages on methane production and consumption. The site acted as either a sink or a source of nitrous oxide depending on the elevation of the water column. Nitrous oxide porewater concentrations peaked at the upper layers of the sediment throughout the different water stages. River hydrological stages significantly influenced porewater concentrations and fluxes of GHG, probably by influencing heterotrophic respiration (production and consumption processes) and transport to and from the HZ. Our results highlight the importance of including dynamic hydrological exchanges when studying and modeling GHG production and consumption in the HZ of large rivers.

54 ENVIRONMENTAL SCIENCES↗

Process design for recovering rare-earth elements from mine tailings with low rare-earth concentrations via sequential leaching and solvent extraction

Rare earth elements (REEs) are essential for advanced technologies and yet face significant supply chain risks due to their concentrated global production and limited domestic availability. Addressing this challenge requires efficient processes capable of upgrading low-grade secondary resources such as mine tailings. In this study, we developed a novel separation flowsheet that integrates sequential leaching and 2-stage solvent extraction (SX) processes to recover high-purity heavy REEs (HREEs) and light REEs (LREEs) from a simulated mine-tailing concentrate containing 2.4 wt% total REEs (TREEs; 0.6 wt% LREEs and 1.8 wt% HREEs). Sequential leaching with controlled pH adjustment selectively precipitated REEs while retaining the large amount of impurities in the solution, producing an REE-enriched leachate by following leaching processes with roughly twice the REE concentration and half the impurity concentration compared to that of single-step leaching. The optimized SX flowsheet employed Cyanex 572 to extract HREEs and Fe over LREEs, followed by Fe removal using tributyl phosphate (TBP), while the raffinate stream was processed by SX with di(2-ethylhexyl)phosphoric acid (D2EHPA) to recover LREEs under optimized conditions balancing both extraction efficiency and purity. Although increased extractant availability in the organic phase improved LREE recovery, it also increased co-extraction of Ca, underscoring trade-offs in process optimization. Both HREE- and LREE-rich solutions were subsequently precipitated into solid products via oxalate precipitation, resulting in high-purity REE solids containing ∼92.0 wt% HREEs (∼95.7 wt% TREEs) and ∼92.8 wt% LREEs (∼94.0 wt% TREEs). In conclusion, this proof-of-concept study using simulated mine tailings demonstrates a promising approach for upgrading low-grade REE resources, while highlighting the need for future validation with real materials.

Mine tailings↗

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.