Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONCRETES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Investigating the Depth of Penetration of Radionuclides in Concrete - 16292

This paper focuses on some chemical and structural aspects for mature concrete structural substrate that functions as a barrier to radioactive material migration. Exposure to radioactive material may be a consequence of surface contact, such as resulting from exposure by spills or leaks. In properly-prepared waste storage areas, undamaged paint and sealant helps to protect the structural cement. However, damaged surfaces, cracks, and relatively porous slab seams can offer a preferred migration pathway for spilled contaminates, including radionuclides. The cost of remediation of concrete structures is directly related to the amount of concrete that must be removed and subsequently disposed. A carefully implemented investigative plan can be utilized to determine how much concrete must be removed and the approximate level of volumetric radiological contamination can be used to estimate disposal costs. Normal concrete pore solution is saturated with calcium hydroxide and also contains sodium and potassium hydroxide; the pH is typically 13 to 14. Contaminants (such as uranium) that hydrolyze in alkaline media that form precipitant phases and tend to deposit at the near-surface. However, more soluble contaminants, such as Cs-137 (as Cs{sup +}) and Tc-99 (as the pertechnetate anion TcO{sub 4}{sup -}) diffuse more rapidly (and deeply) into the porous substrate. Profiling the migration of the water-soluble radionuclides into a cure (hardened) cement surface is a challenge, since water-cooled saws, borers and similar implements are often used to excise and/or slice the core. Alternately, dry mechanical fracturing for excavation of cement may introduce the possibility of material cross-contamination and uncertainty for the average sampling depth for the sample collection event, potentially yielding non-representative samples, and may preclude determination of crack formation that may have been present in the native (non-fractured) substrate. Structural concrete is comprised of cement and pozzolan paste, relatively impervious aggregate (typically stone and/or sand), and rebar (iron reinforcement). Near-surface aggregate may act as a hydrolytic barrier, causing contaminants leached into the pore water to by-pass the impervious grains, causing deeper-than expected penetration, especially if there are grain boundary cracks also present to facilitate migration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of Chemical Wastes on Concrete through Spectroscopic and Computational Models - 18405

Liquid mercury was used as a coolant for early fast reactors, as catalyst in the dissolution of uranium alloy fuels, lithium isotope separation and other processes. Cesium is produced during nuclear fission reactions within the reactor. The interaction between chemical contaminants and solid structures can cause structural damages (e.g. dislocations) and consequently modify the material's mechanical properties. Another problem associated with the interaction of chemical contaminants and metal structures is corrosion pitting. Mercury intrusion porosimetry (MIP) has been utilized to investigate the pore structure of the cement material. The overall goal of this project is to determine the physiochemical interactions of Hg and Cs to steel and concrete using spectroscopic analysis: - Evaluate the physicochemical interactions of Hg and Cs to steel and concrete using spectroscopic techniques under standard conditions; - Evaluate the impact of environmental conditions (temp., salt content, pH, and time) on the physicochemical interactions of Hg and Cs to steel and concrete using spectroscopic techniques. Conclusion and Future Work: Adsorption process depends on the surface morphology. Surface morphology analysis demonstrated that concrete samples had a heterogenous surface. Adsorption of Mercury and Cesium are more favorable onto heterogeneous regions such as edges, grooves, and wrinkles. The mechanism for cation removal by concrete includes surface complexation and ion exchange. Overall adsorption of Mercury was more favorable than Cesium onto concrete. Continuing investigations will be focusing on application considerations such as multicomponent interactions and desorption studies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Concrete structural health monitoring in nuclear power plants - 212

Assessment and management of aging concrete structures in nuclear power plants require a more systematic approach than simple reliance on existing code margins of safety. Health monitoring of concrete structures is performed in order to understand the current condition of a structure based on heterogeneous measurements and produce high-confidence actionable information regarding structural integrity. This information can be used to support operational and maintenance decisions. This paper describes a framework of research activities for health monitoring of nuclear power plant concrete structures. The proposed framework consists of four elements: (1) health monitoring, (2) data analytics, (3) uncertainty quantification, and (4) prognosis. The goal of this framework is to enable plant operators to make risk-informed decisions about structural integrity, remaining useful life, and performance of concrete structures across the nuclear fleet. Among several concrete degradations, research focuses on degradation caused by the alkali-silica reaction (ASR). ASR is a chemical reaction that, in the presence of sufficient moisture, forms a gel that increases in volume and exerts an expansive pressure inside the material, thus causing micro to macro-cracks. This paper also presents development of controlled concrete samples with reactive aggregates to cause ASR degradation and application of different non-destructive evaluation techniques to detect the damage caused by ASR. Initial results are presented in the paper along with a potential path forward. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nondestructive Evaluation of Concrete: Elastic Property Imaging Through Full-Waveform Inversion

Concrete is a vital material in construction—especially in the nuclear industry, where it is used in critical structures such as containment vessels. Over time, concrete can degrade due to harsh operational and environmental conditions, necessitating that its elastic properties be accurately evaluated to ensure structural integrity and safety. Traditional nondestructive evaluation methods such as ultrasound-based techniques often rely on simplifying assumptions that may not hold true for concrete. This paper presents an advanced ultrasound-based method that uses elastic full-waveform inversion (EFWI) to create detailed images of concrete’s mechanical properties. By accurately modeling wave behaviors such as scattering and reflection, we aim to overcome the limitations of conventional ultrasonic-based methods. In this work, the imaging problem involved reconstructing the various elastic properties of a heterogenous concrete block with three steel rebars embedded in it. The ultrasonic measurements were synthetically generated from multiple sources and receivers, and the reconstruction process was performed using a gradient-based optimization algorithm. Our approach leveraged EFWI to reconstruct high-resolution images of the pressure wave speed, shear wave speed, and density. Multiple misfit functions—including L2-norm, cross-correlation (CC), and L1-norm—combined with total variation (TV) regularization and parameter constraints using a Sigmoid function—were explored for the reconstruction. The results demonstrated that using the L1-norm misfit function in conjunction with TV regularization and Sigmoid constraints significantly improved the reconstruction quality in comparison to traditional methods. This approach provided clearer images with fewer artifacts and better captured background heterogeneity. Our findings highlight that, when properly designed, EFWI carries great potential for providing comprehensive, more accurate, and more reliable assessments of concrete conditions, as is crucial for the maintenance and safety of nuclear power plant structures.

97 - MATHEMATICS AND COMPUTING↗

Characterization of Laboratory Prepared Concrete Pastes Exposed to High Alkaline and High Sodium Salt Solutions

The objective of this study was to identify potential chemical degradation mechanisms for the Saltstone Disposal Unit (SDU) concretes, which over the performance life of the structures may be exposed to highly alkaline sodium salt solutions containing sulfate, hydroxide, and other potentially corrosive chemicals in salt solution and saltstone flush water, drain water, leachate and / or pore solution. The samples analyzed in this study were cement pastes prepared in the SIMCO Technologies, Inc. concrete laboratory. They were based on the paste fractions of the concretes used to construct the Saltstone Disposal Units (SDUs). SDU 1 and 4 concrete pastes were represented by the PV1 test specimens. The paste in the SDU 2, 3, 5, and 6 concrete was represented by the PV2 test specimens. SIMCO Technologies, Inc. selected the chemicals and proportions in the aggressive solutions to approximate proportions in the saltstone pore solution [2, 3, 5, and 6]. These test specimens were cured for 56 days in curing chamber before being immersed in aggressive solutions. After exposure, the samples were frozen to prevent additional chemical transport and reaction. Selected archived (retrieved from the freezer) samples were sent to the Savannah River National Laboratory (SRNL) for additional characterization using x-ray diffraction (XRD), scanning electron microscopy (SEM), and energy dispersive x-ray (EDX) spectroscopy. Characterization results are summarized in this report. In addition, a correlation between the oxide composition of the pastes and their chemical durability in the alkaline salt solutions is provided.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nonlinear Impact-Echo Test for Quantitative Evaluation of ASR Damage in Concrete

Nonlinear acoustic methods demonstrate high sensitivity for concrete damage evaluation. Among these methods, nonlinear resonance acoustic methods have been widely used in laboratory tests on small scale test samples. In this study, a nonlinear impact-echo (IE) method for concrete damage evaluation was introduced, in which the IE frequency shift was measured at different impact force levels. The nonlinear IE test and the nonlinear impact resonance acoustic spectroscopy (NIRAS) test share similarities in the experimental setup and analysis method. However, the nonlinear IE test excites a local thickness resonance mode of a member instead of the global resonance vibration. Therefore, the analyzed mode is unaffected by member boundary conditions and is applicable to large concrete structural members. To identify the fundamental IE frequencies, multiple impacts were applied along the members. Once the fundamental IE frequencies were determined, the effectiveness of the nonlinear IE method was evaluated by testing seven concrete beam specimens with varying levels of alkali-silica reaction (ASR) damage. In conclusion, the nonlinear IE test demonstrates high sensitivity to concrete damage and allows for quantitative assessment of the damage state of concrete without a baseline measurement.

36 MATERIALS SCIENCE↗

Deterioration of concrete due to ASR: Experiments and multiscale modeling

The process of ASR (Alkali-Silica Reaction) induced expansion and damage in pavement concrete specimens is investigated using laboratory experiments and computational modeling. In the experimental program, the concrete specimens are subject to CS-CPT (climate simulation concrete prism test) to obtain ASR induced expansion with and without external supply of alkali. The dissolution rates of the granodiorite used in the concrete mix and the gel formation rates are determined under concrete-like conditions (pH 13.8, with/without Ca(OH){sub 2} and NaCl) at different temperatures. A micromechanics based computational model with aggregate-scale diffusion and reaction kinetics coupled to an Eigenstrain based micromechanics damage model is developed for the simulation of ASR induced expansion and damage. Data from the experimental program are used to calibrate and validate the computational model. Model predictions show that for the given concrete mixture, ASR induced expansion in the specimen exposed to water is predominantly governed by microcracking in the aggregate, while the expansion in the specimen subjected to external alkali supply is governed by microcracking in both the aggregates and the cement paste.

36 MATERIALS SCIENCE↗

Microstructure homogenization of concrete used in nuclear power plants

Almost all nuclear power plants in the United States are operating past their intended lifetimes or are requesting lifetime extensions. Therefore, understanding changes to the concrete containment structure over time is crucial to evaluate the structure’s continued viability. Concrete materials are heterogeneous particulate composites that exhibit viscoelastic material properties, which can lead to slow deformation over time, causing stress redistribution and the potential for creep cracking. A code to generate random, three dimensional (3D) concrete microstructures has been developed and paired with finite element analysis to predict the long-term viscoelastic properties of concrete. Data from these simulations are used to develop constitutive equations for the viscoelastic behavior of the homogenized concrete. The codes in this work are used to virtualize laboratory experiments, to obtain long-term creep data in a faster, cheaper manner. To validate this work, the simulated creep behavior of concrete is compared to 800 d of experimental data that has been extended to 27 y of data using the Time-Temperature superposition (TTS) principal. Excellent agreement between the simulation results and experimental data is seen.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Irradiated recycled plastic as a concrete additive for improved chemo-mechanical properties and lower carbon footprint

Concrete production contributes heavily to greenhouse gas emissions, thus a need exists for the development of durable and sustainable concrete with a lower carbon footprint. This can be achieved when cement is partially replaced with another material, such as waste plastic, though normally with a tradeoff in compressive strength. This study discusses progress toward a high/medium strength concrete with a dense, cementitious matrix that contains an irradiated plastic additive, recovering the compressive strength while displacing concrete with waste materials to reduce greenhouse gas generation. Compressive strength tests showed that the addition of high dose (100 kGy) irradiated plastic in multiple concretes resulted in increased compressive strength as compared to samples containing regular, nonirradiated plastic. This suggests that irradiating plastic at a high dose is a viable potential solution for regaining some of the strength that is lost when plastic is added to cement paste. X-ray Diffraction (XRD), Backscattered Electron Microscopy (BSE), and X-ray microtomography explain the mechanisms for strength retention when using irradiated plastic as a filler for cement paste. By partially replacing Portland cement with a recycled waste plastic, this design may have a potential to contribute to reduced carbon emissions when scaled to the level of mass concrete production.

42 ENGINEERING↗

Characterization of Radiation Fields for Assessing Concrete Degradation in Biological Shields of NPPs

Life extensions of nuclear power plants (NPPs) to 60 years of operation and the possibility of subsequent license renewal to 80 years have renewed interest in long-term material degradation in NPPs. Large irreplaceable sections of most nuclear generating stations are constructed from concrete, including safety-related structures such as biological shields and containment buildings; therefore, concrete degradation is being considered with particular focus on radiation-induced effects. Based on the projected neutron fluence values (E > 0.1 MeV) in the concrete biological shields of the US pressurized water reactor fleet and the currently available data on radiation effects on concrete, some decrease in mechanical properties of concrete cannot be ruled out during extended operation beyond 60 years. An expansion of the irradiated concrete database is desirable to ensure reliable risk assessment for extended operation of nuclear power plants.

Remec, Igor↗

A novel use of frequency-banded synthetic aperture focusing technique for reconstructions of alkali-silica reaction in thick-reinforced concrete structures

As they degrade and age, concrete structures are susceptible to the development of multiple defects, such as alkali-silica reaction (ASR). ASR forms a gel that occurs over time between alkaline cement paste and reactive, noncrystalline silica in aggregates [1]. With the continuing extension of the life span of nuclear power plants, it is important to monitor the structural integrity of concrete structures after 40+ years. Compression strength, modulus of elasticity, flexural stiffness, shear strength, and tensile strength are performance characteristics susceptible to the development of ASR. Current methods for monitoring for defects and degradation within thick concrete structures require damaging the concrete. Oak Ridge National Laboratory, in collaboration with the University of Pittsburgh, has developed a nondestructive evaluation (NDE) and reconstruction technique that enables deep-image reconstruction of damaged concrete. The frequency-banded synthetic aperture focusing technique (FB-SAFT) is an augmented SAFT reconstruction that segments the time-series data into different frequency bands using wavelets immediately before performing SAFT reconstructions [2]. This paper presents the NDE instrumentation and reconstruction techniques applied to thick-reinforced concrete structures and concludes with preliminary results.

Ezell, N Dianne↗

Mitigating CO 2 emissions of concrete manufacturing through CO 2 -enabled binder reduction

Abstract Past studies on CO 2 utilization in the concrete industry have primarily focused on maximizing sequestered CO 2 , while focusing less on CO 2 avoidance possible by reducing binder use through the addition of CO 2 to concrete formulations. In this paper, we study the net CO 2 reduction and cost benefits achievable by reducing binder loading while adding CO 2 via three approaches: carbonation during curing, carbonation during mixing, or carbonation with recycled concrete aggregate. These techniques are evaluated for a cohort of concrete formulations representing the diverse mixture designs found in the US ready-mixed and precast industries. Each formulation is optimized for reduced binder loading where the use of CO 2 directly in the formulation recovers the lost compressive strength from reduced binder. We show that over an order of magnitude more CO 2 can be avoided when binder reduction is jointly implemented with CO 2 utilization compared to utilizing CO 2 alone. As a result, nearly 40% of the annual CO 2 emissions from the US concrete industry could, in principle, be eliminated without relying on novel supplemental materials, alternative binder, or carbon capture and sequestration. The recently amended 45Q tax credit will not incentivize this strategy, as it only considers carbon sequestration. However, we find that the saved material cost from reduced binder use on its own may provide a significant economic incentive to promote the joint strategy in practice. We conclude that the real value of CO 2 utilization in concrete hinges on exploiting CO 2 -induced property changes to yield additional emission reduction, not by maximizing absorbed CO 2 .

54 ENVIRONMENTAL SCIENCES↗

NEUTRON-IRRADIATION–INDUCED DAMAGE ASSESSMENT IN CONCRETE USING COMBINED PHASE CHARACTERIZATION AND NONLINEAR FAST FOURIER TRANSFORM SIMULATION

Understanding irradiation effects in concrete cavities of light water reactors is critical to the long-term operation (60+ years) of US nuclear power plants. Susceptibility of concrete to neutron irradiation greatly varies as a function of its constituents: coarse aggregates, sand, and hardened cement paste (hcp). In particular, higher irradiation–susceptibility of aggregates was found to be a direct function of radiation-induced volumetric expansion (RIVE), or the propensity of aggregates to swell as a function of mineral contents, structures and textures. Irradiation-induced amorphization is accompanied by significant swelling, especially in silicates. For example, the maximum volumetric expansions of quartz and feldspars have been shown to be as large as ≈ 18% and ≈ 8%, respectively, while the change of density in calcite remains rather low (≈ 0.3–0.5%). High swelling is associated with a high number of covalent bonds (Si–O) and a high degree of polymerization of [SiO4] tetrahedrons. Differential RIVEs between rock-forming minerals cause high stresses and may potentially develop cracking within the aggregates at the interface between aggregates and the hcp and within the hcp. Modeling neutron-irradiation effects in concrete requires addressing the problem at a scale that captures both the details of the aggregates’ mineralogy and texture, which is <~ 100 μm, and the representative size of concrete, which is ~ 10 cm. This requires high-resolution, large mapping capabilities. To this end, the US Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program developed an original tool suite called Microstructure Oriented Scientific Analysis of Irradiated Concrete (MOSAIC) in which Nonlinear 2D-fast Fourier transform (FFT) techniques are employed to model mechanical or irradiation-induced cracking of high-resolution complex microstructures derived from combined mapping techniques, including micro x-ray fluorescence (m-XRF), energy-dispersive x-ray spectroscopy (EDS), electron backscatter diffraction (EBSD), ellipsometry, and scanning electron microscopy (SEM). Irradiated mineral properties are derived from the Irradiated Minerals, Aggregate and Concrete (IMAC) database, which includes available relevant literature data. Rigorous coupled damage-creep simulations are obtained through sequential linear analysis. Illustrations of actual accelerated irradiation-damage propagation in a complex microstructures are presented herein.

Le Pape, Yann↗

OECD MCCI Project: 2-D Core Concrete Interaction (CCI) Tests CCI-5 Data Report (Rev. 1)

Ex-vessel debris coolability is an important light water reactor (LWR) safety issue. For existing plants, resolution of this issue will confirm the technical basis for severe accident management guidelines (SAMGs). For new reactors, understanding this issue will help confirm the effectiveness of the design and implementation of new accident mitigation features and severe accident management design alternatives (SAMDAs). The first OECD-MCCI program conducted reactor material experiments focused on achieving the following technical objectives: i) provide confirmatory evidence for various cooling mechanisms through separate effect tests and data for severe accident code model development, and ii) provide longer-term two-dimensional core-concrete interaction data for code assessment and improvement. As one of the steps in satisfying these program objectives, the Management Board (MB) approved the conduct of a fifth longer-term 2-D Core-Concrete Interaction (CCI) experiment designed to provide information in several areas, including: i) lateral vs. axial power split during dry core-concrete interaction, ii) integral debris coolability data following late phase flooding, and iii) data regarding the nature and extent of the cooling transient following breach of the crust formed at the melt-water interface. The first three tests in this experiment series investigated the interaction of fully oxidized PWR core melt compositions with specially designed concrete test sections that were initially 50 cm x 50 cm in cross-sectional area. Both siliceous and limestone/common sand concrete types were addressed. The fourth test examined the interaction of a partially oxidized BWR melt composition with limestone/common sand concrete. The objective of this data report is to provide the thermalhydraulic results from this test. To this end, a summary description of the test apparatus is provided first, followed by descriptions of the test operating procedure and key experiment results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

OECD MCCI Project: Category 4 Integral Test to Validate Severe Accident Codes: Core-Concrete Interaction Test Six (CCI-6) Test Plan (Rev. 6)

Ex-vessel debris coolability is an important light water reactor (LWR) safety issue. For existing plants, resolution of this issue will confirm the technical basis for severe accident management guidelines (SAMGs). For new reactors, understanding this issue will help confirm the effectiveness of the design and implementation of new accident mitigation features and severe accident management design alternatives (SAMDAs). The first OECD-MCCI program conducted reactor material experiments focused on achieving the following technical objectives: i) provide confirmatory evidence and data for various cooling mechanisms through separate effect tests for severe accident model development, and ii) provide long-term 2-D core-concrete interaction data for code assessment and improvement. The PRG recommends that the OA design a 70 cm x 70 cm test, with two concrete side walls, using CEA siliceous concrete, 6 wt% concrete composition, early top flooding initiated when ablation is established and melt temperature has stabilized. The melt depth shall be 30 cm. The test will be designed for two specific phases. The first phase will provide for 30 cm for radial ablation and 25 cm for vertical ablation. In the event that the melt is not cooled down by top flooding during the first phase, a second and separate test phase will begin involving bottom flooding. This second phase will be initiated when axial ablation depth reaches 25 cm. The design should be mindful of the curing time of the concrete. The instrumentation should be refined to provide data on the water injection characteristics and melt temperature near the lateral walls. In response to this recommendation, the objective of this document is to provide a summary test plan for this sixth Core-Concrete Interaction (CCI-6) experiment for PRG review. Test specifications that were developed as part of the design work are provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

OECD MCCI Project: 2-D Core Concrete Interaction (CCI) Tests (CCI-4 Final Report)

Ex-vessel debris coolability is an important light water reactor (LWR) safety issue. For existing plants, resolution of this issue will confirm the technical basis for severe accident management guidelines (SAMGs). For new reactors, understanding this issue will help confirm the effectiveness of the design and implementation of new accident mitigation features and severe accident management design alternatives (SAMDAs). The first OECD-MCCI program conducted reactor material experiments focused on achieving the following technical objectives: i) provide confirmatory evidence for various cooling mechanisms through separate effect tests and data for severe accident code model development, and ii) provide longer-term two-dimensional core-concrete interaction data for code assessment and improvement. As one of the steps in satisfying these program objectives, the Management Board (MB) approved the conduct of a fourth longer-term 2-D Core-Concrete Interaction (CCI) experiment designed to provide information in several areas, including: i) lateral vs. axial power split during dry core-concrete interaction, ii) integral debris coolability data following late phase flooding, and iii) data regarding the nature and extent of the cooling transient following breach of the crust formed at the melt-water interface. The first three tests investigated the interaction of fully oxidized PWR core melt compositions with specially designed concrete test sections that were initially 50 cm x 50 cm in cross-sectional area. Both siliceous and limestone/common sand concrete types were addressed in the test matrix. The fourth test that is addressed in this report, CCI-4, utilized a similar test apparatus and experiment boundary conditions, including a limestone/common sand concrete test section. However, instead of a fully oxidized PWR melt, CCI-4 utilized a partially oxidized BWR core melt containing ~ 8 wt % structural steel constituents. Thus, this test evaluated the effect of elevated melt metal content on two-dimensional cavity erosion and debris cooling behavior. The experiment was conducted on May 26, 2007, and early experiment results were reported in a quick-look data report. The objective of this final report is to document both the thermalhydraulic and posttest debris examination results for this test. To this end, a summary description of the test apparatus is provided first, followed by descriptions of the test operating procedure and experimental results that include both thermalhydraulic data and the findings from the posttest examinations. Overall specifications for CCI-4 are provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Standard Operating Procedure (SOP) Repair Of Cracks And Spalls Within The Concrete Facade Covering The Runit Island Waste Containment Structure

The concrete repair shall be performed using a combination of pre-packaged cement-based mortar (Structural Concrete® V/O) supplied by Five Star Products, Inc., and CRACKBOND® products from Adhesive Technology Corp., Pompano Beach, Florida. Five Star Structural Concrete® V/O is a high strength, rapid setting, one component, permanent concrete repair material used primarily for vertical and overhead structural repairs. The material produces a repair which is dimensionally stable, develops an integral bond to existing concrete, and restores structural integrity within hours of placement (Five Star DESIGN-A-SPEC™ Guidelines). The CRACKBOND® family of products are two component, high strength structural epoxy formulations specifically designed to repair cracks in concrete.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Repair of Cracks and Spalls within the Concrete Façade Covering the Runit Island Waste Containment Structure (V.2.0)

The concrete repair shall be performed using a combination of pre-packaged cement-based mortar (Structural Concrete® V/O) supplied by Five Star Products, Inc., and CRACKBOND® products from Adhesive Technology Corp., Pompano Beach, Florida. Five Star Structural Concrete® V/O is a high strength, rapid setting, one component, permanent concrete repair material used primarily for vertical and overhead structural repairs. The material produces a repair which is dimensionally stable, develops an integral bond to existing concrete, and restores structural integrity within hours of placement (Five Star DESIGN-A-SPEC™ Guidelines). The CRACKBOND® family of products are two component, high strength structural epoxy formulations specifically designed to repair cracks in concrete.

54 ENVIRONMENTAL SCIENCES↗