Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Risk of Late Toxicity in Men Receiving Dose-Escalated Hypofractionated Intensity Modulated Prostate Radiation Therapy: Results From a Randomized Trial

Objective: To report late toxicity outcomes from a randomized trial comparing conventional and hypofractionated prostate radiation therapy and to identify dosimetric and clinical parameters associated with late toxicity after hypofractionated treatment. Methods and Materials: Men with localized prostate cancer were enrolled in a trial that randomized men to either conventionally fractionated intensity modulated radiation therapy (CIMRT, 75.6 Gy in 1.8-Gy fractions) or to dose-escalated hypofractionated IMRT (HIMRT, 72 Gy in 2.4-Gy fractions). Late (≥90 days after completion of radiation therapy) genitourinary (GU) and gastrointestinal (GI) toxicity were prospectively evaluated and scored according to modified Radiation Therapy Oncology Group criteria. Results: 101 men received CIMRT and 102 men received HIMRT. The median age was 68, and the median follow-up time was 6.0 years. Twenty-eight percent had low-risk, 71% had intermediate-risk, and 1% had high-risk disease. There was no difference in late GU toxicity in men treated with CIMRT and HIMRT. The actuarial 5-year grade ≥2 GU toxicity was 16.5% after CIMRT and 15.8% after HIMRT (P=.97). There was a nonsignificant numeric increase in late GI toxicity in men treated with HIMRT compared with men treated with CIMRT. The actuarial 5-year grade ≥2 GI toxicity was 5.1% after CIMRT and 10.0% after HIMRT (P=.11). In men receiving HIMRT, the proportion of rectum receiving 36.9 Gy, 46.2 Gy, 64.6 Gy, and 73.9 Gy was associated with the development of late GI toxicity (P<.05). The 5-year actuarial grade ≥2 GI toxicity was 27.3% in men with R64.6Gy ≥ 20% but only 6.0% in men with R64.6Gy < 20% (P=.016). Conclusions: Dose-escalated IMRT using a moderate hypofractionation regimen (72 Gy in 2.4-Gy fractions) can be delivered safely with limited grade 2 or 3 late toxicity. Minimizing the proportion of rectum that receives moderate and high dose decreases the risk of late rectal toxicity after this hypofractionation regimen.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Effects in Innovative Structural Materials

The extreme radiation environments and demanding structural conditions of next-generation fission and proposed fusion reactors will require high performance materials with very high radiation resistance. Although conventional structural materials such as ferritic/ martensitic steels offer several attractive features, there is value in exploring alternative materials systems that may offer unprecedented radiation stability while also offering good thermomechanical properties. As noted elsewhere, options for designing radiation resistance include (a) the traditional approach of introducing a very high sink strength for recombination of radiation-induced vacancies and interstitials (e.g., Ti-modified stainless steels or 'nano-cluster-strengthened ferritic alloys', (b) utilizing materials with immobile vacancies at the operating temperature (e.g., silicon carbide), and (c) utilizing certain classes of materials that inherently exhibit superior resistance to radiation defect retention and accumulation (e.g., ferritic steels). Three relatively new but promising structural materials systems were selected for investigation, based on their favorable unirradiated mechanical properties and potential for good stability under irradiation: High entropy alloys (HEAs), bulk metallic glass (BMG), and MAX phase ceramics. The high configurational entropy in HEAs might alter point defect (solute and radiation defects) diffusion processes, thus potentially enhancing the recombination of radiation-produced damage. Therefore, HEAs offer the potential of a new class of materials for radiation resistance category (c) mentioned previously. A variety of BMGs such as Zr{sub 52.5}Cu{sub 17.9}Ni{sub 14.6}Al{sub 10}Ti{sub 5} offer good mechanical properties including fracture toughness values that may exceed 100 MPa-m{sup 1/2} and near net shape fabrication potential. The lack of crystallinity in BMGs prohibits the formation of conventional Frenkel pair defects under irradiation and therefore offer the possibility of another new material system for radiation resistance category (c). MAX phase ceramics (e.g., Ti{sub 3}SiC{sub 2}, Ti{sub 3}AlC{sub 2}, Ti{sub 2}AlC) have good mechanical properties and contain a nano-laminate structure that could provide a very high point defect sink strength. Due to their refractory nature, many of the MAX phase ceramics may exhibit negligible vacancy mobility up to high temperatures. Therefore, MAX phase ceramics offer the potential to provide radiation resistance in either categories (a) and (b), depending on the operating temperature. For this study, a novel 27%Fe-27%Mn-28%Ni-18%Cr single phase face centered cubic high entropy alloy was synthesized that exhibited good strength and ductility over a wide temperature range. Zr{sub 52.5}Cu{sub 17.9}Ni{sub 14.6}Al{sub 10}Ti{sub 5} (BAM-11) was selected as a prototypic advanced BMG. Several MAX phase ceramics (e.g., Ti{sub 3}SiC{sub 2}, Ti{sub 3}AlC{sub 2}, Ti{sub 2}AlC) that have good unirradiated thermal and mechanical properties were also investigated. The irradiation damage behaviors of these three novel materials systems have been studied after fission neutron at ∼75 deg. C up to 1 dpa and Ni ion irradiation at 25- 700 deg. C up to 30 dpa (lower temperatures and doses for the BMGs). All three sets of materials generally exhibited good radiation stability within certain temperature regimes. For example, the BMG exhibited only minor (<10%) change in strength that appeared to saturate after a dose of ∼1 dpa. A key shortcoming of current BMGs are that they can not be used at temperatures >>300 deg. C due to glass to crystalline transition at elevated temperature. The MAX phase ceramics irradiated at 400-700 deg. C appeared to be in the 'low temperature' regime where vacancies are immobile and therefore the radiation hardening saturated at relatively low doses. The Ti{sub 3}SiC{sub 2} MAX phase exhibited the best overall radiation stability over a wide temperature range. The HEA exhibited fine scale dislocation loop formation, no observable cavity swelling and reduced amounts of Cr depletion compared to traditional austenitic Fe-Cr-Ni alloys after ion irradiation, which suggests suppressed point defect and solute diffusion behavior. (authors)

36 MATERIALS SCIENCE↗

Updated Results and Patterns of Failure in a Randomized Hypofractionation Trial for High-risk Prostate Cancer

Purpose: To report long-term results and patterns of failure after conventional and hypofractionated radiation therapy in high-risk prostate cancer. Methods and Materials: This randomized phase III trial compared conventional fractionation (80 Gy at 2 Gy per fraction in 8 weeks) vs hypofractionation (62 Gy at 3.1 Gy per fraction in 5 weeks) in combination with 9-month androgen deprivation therapy in 168 patients with high-risk prostate cancer. Freedom from biochemical failure (FFBF), freedom from local failure (FFLF), and freedom from distant failure (FFDF) were analyzed. Results: In a median follow-up of 70 months, biochemical failure (BF) occurred in 35 of the 168 patients (21%) in the study. Among these 35 patients, local failure (LF) only was detected in 11 (31%), distant failure (DF) only in 16 (46%), and both LF and DF in 6 (17%). In 2 patients (6%) BF has not yet been clinically detected. The risk reduction by hypofractionation was significant in BF (10.3%) but not in LF and DF. We found that hypofractionation, with respect to conventional fractionation, determined only an insignificant increase in the actuarial FFBF but no difference in FFLF and FFDF, when considering the entire group of patients. However, an increase in the 5-year rates in all 3 endpoints-FFBF, FFLF, and FFDF-was observed in the subgroup of patients with a pretreatment prostate-specific antigen (iPSA) level of 20 ng/mL or less. On multivariate analysis, the type of fractionation, iPSA level, Gleason score of 4+3 or higher, and T stage of 2c or higher have been confirmed as independent prognostic factors for BF. High iPSA levels and Gleason score of 4+3 or higher were also significantly associated with an increased risk of DF, whereas T stage of 2c or higher was the only independent variable for LF. Conclusion: Our results confirm the isoeffectiveness of the 2 fractionation schedules used in this study, although a benefit in favor of hypofractionation cannot be excluded in the subgroup of patients with an iPSA level of 20 ng/mL or less. The {alpha}/{beta} ratio might be more appropriately evaluated by FFLF than FFBF results, at least in high-risk disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-resilient InAs quantum dot lasers

Displacement damage from particle radiation increases the threshold current of semiconductor lasers, impeding the deployment of photonic systems in harsh radiation environments. Replacing conventional quantum well (QW) gain regions with quantum dots (QDs) has been shown to suppress the radiation-induced increase in threshold current owing to three-dimensional carrier confinement, which effectively segregates charge carriers away from radiation-induced defects. However, radiation-induced change in threshold current is also affected by extrinsic design elements of a laser, such as photon lifetime, and therefore provides only a partial assessment of the radiation hardness. In this work, we advance the understanding of the radiation resiliency of InAs QD lasers by extracting the change in the nonradiative recombination rate after radiation exposure, which provides a more fundamental assessment of the intrinsic radiation hardness of InAs QD gain regions. We find that carriers that populate InAs QD states have a nonradiative recombination rate that is over an order-of-magnitude less sensitive to neutron radiation relative to carriers in InGaAsP QWs. InAs QD lasers must be designed such that carriers primarily occupy QD states, preventing carrier spillover into surrounding barrier layers to obtain the maximum benefit. Furthermore, we show that enhanced radiation hardness is observed in InAs QD lasers grown on both highly lattice-mismatched silicon substrates and native GaAs substrates, further broadening the appeal of InAs QD lasers as reliable light sources for photonic systems operating in harsh radiation environments.

47 OTHER INSTRUMENTATION↗

Small-Scale Drop Size Variability: Impact on Estimation of Cloud Optical Properties

Most cloud radiation models and conventional data processing techniques assume that the mean number of drops of a given radius is proportional to volume. The analysis of microphysical data on liquid water drop sizes shows that, for sufficiently small volumes, this proportionality breaks down; the number of cloud drops of a given radius is instead proportional to the volume raised to a drop size-dependent nonunit power. The coefficient of proportionality, a generalized drop concentration, is a function of the drop size. For abundant small drops the power is unity as assumed in the conventional approach. However, for rarer large drops, it falls increasingly below unity. This empirical fact leads to drop clustering, with the larger drops exhibiting a greater degree of clustering. The generalized drop concentration shows the mean number of drops per cluster, while the power characterizes the occurrence frequency of clusters. With a fixed total number of drops in a cloud, a decrease in frequency of clusters is accompanied by a corresponding increase in the generalized concentration. This initiates a competing process missed in the conventional models: an increase in the number of drops per cluster enhances the impact of rarer large drops on cloud radiation while a decrease in the frequency suppresses it. Because of the nonlinear relationship between the number of clustered drops and the volume, these two opposite tendencies do not necessarily compensate each other. The data analysis suggests that clustered drops likely have a stronger radiative impact compared to their unclustered counterpart; ignoring it results in underestimation of the contribution from large drops to cloud horizontal optical path.

Knyazikhin, Y.↗

WE-FG-BRA-05: Potential Clinical Benefit of LINAC Flattening-Filter-Free (FFF) Mode - Improvement of Treatment Therapeutic Ratio

Purpose: Ultrahigh dose-rate radiation at >40Gy/s has demonstrated astonishing normal-tissue sparing and tumor control in recent preclinical naive and tumor-bearing rodent studies when compared to the same radiation dose at a conventional dose-rate. The working mechanism of this fascinating dose-rate effect is currently under investigation. The aims of this work include investigating 1) whether LINAC FFF mode radiation at approximately 1Gy/s also has an improved therapeutic ratio compared to the same radiation dose at the conventional dose-rate of 0.05Gy/s, and 2) the dose-rate effect’s potential working mechanism by studying the expression of the P53 gene, linked to tumor suppression and cell regulation after radiation damage. Methods: We used mouse model C57BL/6J, the same as that used in the ultrahigh dose-rate studies, and exposed them to total body irradiation (TBI) using the Elekta Versa accelerator 10MV photons. Mice (N=20) were given a total dose of 12Gy in both the high dose-rate group (n=10) using the FFF-mode and the conventional dose-rate group (n=10) using the conventional does rate mode. The FFF-mode treatment setup consisted of a 15cm×15cm field size setting at 53.2cm SSD while the conventional-mode set-up consisted of a 10cm×10cm field size at 100SSD. Post-radiation, animals were monitored daily for survival analysis and signs of moribundity requiring euthanasia. In addition, mouse spleens were harvested for P53 analysis at different time points. Results: For 12Gy TBI, the 1.3Gy/s FFF-mode high dose-rate produced a statistically significant (p=0.02) improvement in mouse survival compared to the 0.05Gy/s conventional dose-rate. An initial P53 study at the time of death time-point indicates that high dose-rate radiation induced a stronger expression of P53 than conventional dose-rate radiation. Conclusion: Our pilot study indicates that the FFF-mode high dose-rate radiation, which has been used largely to improve clinical throughput, may provide the added clinical benefit of improving treatment therapeutic ratio. Animal Studies were performed within the LCCC Animal Studies Core Facility at the University of North Carolina at Chapel Hill. The LCCC Animal Studies Core is supported in part by an NCI Center Core Support Grant (CA16086) to the UNC Lineberger Comprehensive Cancer Center.

60 APPLIED LIFE SCIENCES↗

Radiological health risks for exploratory class missions in space

The radiation risks to crewmembers on missions to the moon and Mars are studied. A graph is presented of the cross section as a function of linear energy transfer (LET) for cell inactivation and neoplastic cell transformation. Alternatives to conventional approaches to radiation protection using dose and Q are presented with attention given to a hybrid of the conventional system for particles with LET less than 100 keV/micron.

Nachtwey, D. Stuart↗

Dynamic volume vs respiratory correlated 4DCT for motion assessment in radiation therapy simulation

Purpose: Conventional (i.e., respiratory-correlated) 4DCT exploits the repetitive nature of breathing to provide an estimate of motion; however, it has limitations due to binning artifacts and irregular breathing in actual patient breathing patterns. The aim of this work was to evaluate the accuracy and image quality of a dynamic volume, CT approach (4D{sub vol}) using a 320-slice CT scanner to minimize these limitations, wherein entire image volumes are acquired dynamically without couch movement. This will be compared to the conventional respiratory-correlated 4DCT approach (RCCT). Methods: 4D{sub vol} CT was performed and characterized on an in-house, programmable respiratory motion phantom containing multiple geometric and morphological ''tumor'' objects over a range of regular and irregular patient breathing traces obtained from 3D fluoroscopy and compared to RCCT. The accuracy of volumetric capture and breathing displacement were evaluated and compared with the ground truth values and with the results reported using RCCT. A motion model was investigated to validate the number of motion samples needed to obtain accurate motion probability density functions (PDF). The impact of 4D image quality on this accuracy was then investigated. Dose measurements using volumetric and conventional scan techniques were also performed and compared. Results: Both conventional and dynamic volume 4DCT methods were capable of estimating the programmed displacement of sinusoidal motion, but patient breathing is known to not be regular, and obvious differences were seen for realistic, irregular motion. The mean RCCT amplitude error averaged at 4 mm (max. 7.8 mm) whereas the 4D{sub vol} CT error stayed below 0.5 mm. Similarly, the average absolute volume error was lower with 4D{sub vol} CT. Under irregular breathing, the 4D{sub vol} CT method provides a close description of the motion PDF (cross-correlation 0.99) and is able to track each object, whereas the RCCT method results in a significantly different PDF from the ground truth, especially for smaller tumors (cross-correlation ranging between 0.04 and 0.69). For the protocols studied, the dose measurements were higher in the 4D{sub vol} CT method (40%), but it was shown that significant mAs reductions can be achieved by a factor of 4-5 while maintaining image quality and accuracy. Conclusions: 4D{sub vol} CT using a scanner with a large cone-angle is a promising alternative for improving the accuracy with which respiration-induced motion can be characterized, particularly for patients with irregular breathing motion. This approach also generates 4DCT image data with a reduced total scan time compared to a RCCT scan, without the need for image binning or external respiration signals within the 16 cm scan length. Scan dose can be made comparable to RCCT by optimization of the scan parameters. In addition, it provides the possibility of measuring breathing motion for more than one breathing cycle to assess stability and obtain a more accurate motion PDF, which is currently not feasible with the conventional RCCT approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators

Purpose: Accurate dosimetry is essential when irradiating mice to ensure that functional and molecular endpoints are well understood for the radiation dose delivered. Conventional methods of prescribing dose in mice involve the use of a single dose rate measurement and assume a uniform average dose throughout all organs of the entire mouse. Here, the authors report the individual average organ dose values for the irradiation of a 12, 23, and 33 g mouse on a 320 kVp x-ray irradiator and calculate the resulting error from using conventional dose prescription methods. Methods: Organ doses were simulated in the Geant4 application for tomographic emission toolkit using the MOBY mouse whole-body phantom. Dosimetry was performed for three beams utilizing filters A (1.65 mm Al), B (2.0 mm Al), and C (0.1 mm Cu + 2.5 mm Al), respectively. In addition, simulated x-ray spectra were validated with physical half-value layer measurements. Results: Average doses in soft-tissue organs were found to vary by as much as 23%–32% depending on the filter. Compared to filters A and B, filter C provided the hardest beam and had the lowest variation in soft-tissue average organ doses across all mouse sizes, with a difference of 23% for the median mouse size of 23 g. Conclusions: This work suggests a new dose prescription method in small animal dosimetry: it presents a departure from the conventional approach of assigninga single dose value for irradiation of mice to a more comprehensive approach of characterizing individual organ doses to minimize the error and uncertainty. In human radiation therapy, clinical treatment planning establishes the target dose as well as the dose distribution, however, this has generally not been done in small animal research. These results suggest that organ dose errors will be minimized by calibrating the dose rates for all filters, and using different dose rates for different organs.

54 ENVIRONMENTAL SCIENCES↗

The Adoption of New Adjuvant Radiation Therapy Modalities Among Medicare Beneficiaries With Breast Cancer: Clinical Correlates and Cost Implications

Purpose: New radiation therapy modalities have broadened treatment options for older women with breast cancer, but it is unclear how clinical factors, geographic region, and physician preference affect the choice of radiation therapy modality. Methods and Materials: We used the Surveillance, Epidemiology, and End Results-Medicare database to identify women diagnosed with stage I-III breast cancer from 1998 to 2007 who underwent breast-conserving surgery. We assessed the temporal trends in, and costs of, the adoption of intensity modulated radiation therapy (IMRT) and brachytherapy. Using hierarchical logistic regression, we evaluated the relationship between the use of these new modalities and patient and regional characteristics. Results: Of 35,060 patients, 69.9% received conventional external beam radiation therapy (EBRT). Although overall radiation therapy use remained constant, the use of IMRT increased from 0.0% to 12.6% from 1998 to 2007, and brachytherapy increased from 0.7% to 9.0%. The statistical variation in brachytherapy use attributable to the radiation oncologist and geographic region was 41.4% and 9.5%, respectively (for IMRT: 23.8% and 22.1%, respectively). Women undergoing treatment at a free-standing radiation facility were significantly more likely to receive IMRT than were women treated at a hospital-based facility (odds ratio for IMRT vs EBRT: 3.89 [95% confidence interval, 2.78-5.45]). No such association was seen for brachytherapy. The median radiation therapy cost per treated patient increased from $5389 in 2001 to $8539 in 2007. Conclusions: IMRT and brachytherapy use increased substantially from 1998 to 2007; overall, radiation therapy costs increased by more than 50%. Radiation oncologists played an important role in treatment choice for both types of radiation therapy, whereas geographic region played a bigger role in the use of IMRT than brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential for Higher Treatment Failure in Obese Patients: Correlation of Elevated Body Mass Index and Increased Daily Prostate Deviations From the Radiation Beam Isocenters in an Analysis of 1,465 Computed Tomographic Images

Purpose: Recent clinical outcome studies on prostate cancer have reported the influence of patient's obesity on the biochemical failure rates after various treatment modalities. In this study, we investigated the effect of patient's physical characteristics on prostate shift in external beam radiotherapy (EBRT) and hypothesized that there maybe a correlation between patient physique and tumor shift. Methods and Materials: A retrospective analysis was performed using data for 117 patients who received image-guided radiation therapy (IGRT) for prostate cancer between January 2005 and April 2007. A total of 1,465 CT scans were analyzed. The standard deviations (SDs) of prostate shifts for all patients, along with patient weight, body mass index (BMI), and subcutaneous adipose-tissue thickness (SAT), were determined. Spearman rank correlation analysis was performed. Results: Of the 117 patients, 26.5% were considered normal weight, 48.7% were overweight, 17.9% were mildly obese, and 6.9% were moderately to severely obese. Notably 1.3%, 1.5%, 2.0%, and 21.2% of the respective shifts were greater than 10 mm in the left-right (LR) direction for the four patient groups, whereas in the anterior-posterior direction the shifts are 18.2%, 12.6%, 6.7%, and 21.0%, respectively. Strong correlations were observed between SAT, BMI, patient weight, and SDs of daily shifts in the LR direction (p < 0.01). Conclusions: The strong correlation between obesity and shift indicates that without image-guided radiation therapy, the target volume (prostate with or without seminal vesicles) may not receive the intended dose for patients who are moderate to severely obese. This may explain the higher recurrence rate with conventional external beam radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cosmetic Outcome and Seroma Formation After Breast-Conserving Surgery With Intraoperative Radiation Therapy Boost for Early Breast Cancer

Purpose: To evaluate cosmetic outcome and its association with breast wound seroma after breast-conserving surgery (BCS) with targeted intraoperative radiation therapy (tIORT) boost for early breast cancer. Methods and Materials: An analysis of a single-arm prospective study of 55 patients with early breast cancer treated with BCS and tIORT boost followed by conventional whole breast radiation therapy (WBRT) between August 2003 and January 2006 was performed. A seroma was defined as a fluid collection at the primary tumor resection site identified clinically or radiologically. Cosmetic assessments using the European Organization for Research and Treatment of Cancer rating system were performed at baseline before BCS and 30 months after WBRT was completed. Results: Twenty-eight patients (51%) developed a seroma, with 18 patients (33%) requiring at least 1 aspiration. Tumor location was significantly associated with seroma formation (P=.001). Ten of 11 patients with an upper inner quadrant tumor developed a seroma. Excellent or good overall cosmetic outcome at 30 months was observed in 34 patients (62%, 95% confidence interval 53%-80%). Seroma formation was not associated with the overall cosmetic result (P=.54). Conclusion: BCS with tIORT boost followed by WBRT was associated with an acceptable cosmetic outcome. Seroma formation was not significantly associated with an adverse cosmetic outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulating 3-D radiative transfer effects over the Sierra Nevada Mountains using WRF

A surface solar radiation parameterization based on deviations between 3-D and conventional plane-parallel radiative transfer models has been incorporated into the Weather Research and Forecasting (WRF) model to understand the solar insolation over mountain/snow areas and to investigate the impact of the spatial and temporal distribution and variation of surface solar fluxes on land-surface processes. Using the Sierra-Nevada in the western United States as a testbed, we show that mountain effect could produce up to -50 to + 50 W m -2 deviations in the surface solar fluxes over the mountain areas, resulting in a temperature increase of up to 1 °C on the sunny side. Upward surface sensible and latent heat fluxes are modulated accordingly to compensate for the change in surface solar fluxes. Snow water equivalent and surface albedo both show decreases on the sunny side of the mountains, indicating more snowmelt and hence reduced snow albedo associated with more solar insolation due to mountain effect. Soil moisture increases on the sunny side of the mountains due to enhanced snowmelt, while decreases on the shaded side. Substantial differences are found in the morning hours from 8–10 a.m. and in the afternoon around 3–5 p.m., while differences around noon and in the early morning and late afternoon are comparatively smaller. Variation in the surface energy balance can also affect atmospheric processes, such as cloud fields, through the modulation of vertical thermal structure. Negative changes of up to -40 g m -2 are found in the cloud water path, associated with reductions in the surface insolation over the cloud region. The day-averaged deviations in the surface solar flux are positive over the mountain areas and negative in the valleys, with a range between -12~12 W m -2 . Changes in sensible and latent heat fluxes and surface skin temperature follow the solar insolation pattern. Differences in the domain-averaged diurnal variation over the Sierras show that the mountain area receives more solar insolation during early morning and late afternoon, resulting in enhanced upward sensible heat and latent heat fluxes from the surface and a corresponding increase in surface skin temperature. During the middle of the day, however, the surface insolation and heat fluxes show negative changes, indicating a cooling effect. Hence overall, the diurnal variations of surface temperature and surface fluxes in the Sierra-Nevada are reduced through the interactions of radiative transfer and mountains. Finally, the hourly differences of the surface solar insolation in higher elevated regions, however, show smaller magnitude in negative changes during the middle of the day and possibly more solar fluxes received during the whole day.

3-D↗

Radiative Smoothing in Clouds at Transparent and Absorbing Wavelengths

For absorbing and transparent wavelengths, we discuss the effect of horizontal solar radiative fluxes in clouds on the accuracy of a conventional plane-parallel radiative transfer calculations for a single pixel, known as the Independent Pixel Approximation (IPA). We address the question of correlations between horizontal fluxes, IPA accuracies and radiative smoothing. By smoothing we understand a radiative transfer process whereby radiation does not follow the small-scale fluctuations of cloud structure, producing much smoother radiation fields. The scale eta that characterizes this process is called "radiative smoothing scale." We relate radiative smoothing to the photon's horizontal displacement that characterizes a "spot" of reflected light associated with a point source. We generalize the "spot-size" estimate derived for conservative scattering using the diffusion theory to the case of non-conservative scattering. For reflected light, theoretical results are confirmed with numerical simulations. The radiative smoothing scale eta is a critical value where IPA effectively breaks down; for scales smaller than TI, real radiation field are much smoother than their IPA counterparts for the same cloud structure. In addition to the estimate of il for absorbing wavelengths, we show that: (1) with more absorption, the scale break determined by eta in a log-log plot of wavenumber spectra moves towards smaller scales and (2) the smaller eta the flatter the small-scale slope which means less radiative smoothing, thus more accuracy in the IPA reflection.

Marshak, A.↗

Boundary Layer Transition on Slender Cones in Conventional and Low Disturbance Mach 6 Wind Tunnels

An experimental investigation was conducted on a 5-degree half-angle cone and a 5-degree half-angle flared cone in a conventional Mach 6 wind tunnel to examine the effects of facility noise on boundary layer transition. The influence of tunnel noise was inferred by comparing transition onset locations determined from the present test to that previously obtained in a Mach 6 low disturbance quiet tunnel. Together, the two sets of experiments are believed to represent the first direct comparison of transition onset between a conventional and a low disturbance wind tunnel using a common test model and transition detection technique. In the present conventional hypersonic tunnel experiment, separate measurements of heat transfer and adiabatic wall temperatures were obtained on the conical models at small angles of attack over a range of Reynolds numbers, which resulted in laminar, transitional, and turbulent flow. Smooth model turbulent heating distributions are compared to that obtained with transition forced via discrete surface roughness. The model nosetip radius was varied to examine the effects of bluntness on transition onset. Despite wall to total temperature differences between the transient heating measurements and the adiabatic wall temperature measurement, the two methods for determining sharp cone transition onset generally yielded equivalent locations. In the 'noisy' mode of the hypersonic low disturbance tunnel, transition onset occurred earlier than that measured in the conventional hypersonic tunnel, suggesting higher levels of freestream acoustic radiation relative to the conventional tunnel. At comparable freestream conditions, the transition onset Reynolds number under low disturbance conditions was a factor of 1.3 greater than that measured on flared cone in the LaRC conventional hypersonic tunnel and a factor of 1.6 greater that the flared cone run in the low disturbance tunnel run 'noisy'. Navier-Stokes mean flow computations and linear stability analysis were conducted to assess the experimental results and have indicated N factors associated with sharp flared cone transition onset to be approximately a factor of 2 lower than that inferred from the corresponding low disturbance tunnel measurements.

Horvath, Thomas J.↗

SU-E-P-58: Dosimetric Study of Conventional Intensity-Modulated Radiotherapy and Knowledge-Based Radiation Therapy for Postoperation of Cervix Cancer

Purpose: To compare the dosimetric difference of the target volume and organs at risk(OARs) between conventional intensity-modulated radiotherapy(C-IMRT) and knowledge-based radiation therapy (KBRT) plans for cervix cancer. Methods: 39 patients with cervical cancer after surgery were randomly selected, 20 patient plans were used to create the model, the other 19 cases used for comparative evaluation. All plans were designed in Eclipse system. The prescription dose was 30.6Gy, 17 fractions, OARs dose satisfied to the clinical requirement. A paired t test was used to evaluate the differences of dose-volume histograms (DVH). Results: Comparaed to C-IMRT plan, the KBRT plan target can achieve the similar target dose coverage, D98,D95,D2,HI and CI had no difference (P≥0.05). The dose of rectum, bladder and femoral heads had no significant differences(P≥0.05). The time was used to design treatment plan was significant reduced. Conclusion: This study shows that postoperative radiotherapy of cervical KBRT plans can achieve the similar target and OARs dose, but the shorter designing time.

60 APPLIED LIFE SCIENCES↗

Early-Stage Radiation Safety Analysis for the Spallation Neutron Source Second Target Station Bunker Operations

The Second Target Station project at Oak Ridge National Laboratory will develop a cold neutron source to meet growing experimental needs. This paper describes calculations of the residual dose rates associated with the monolith shield plug and the beamline bunker, two key conventional operations and radiation safety features. While neutron production is active, the instrument hall outside the bunker must be generally accessible with dose rates of less than 0.25 mrem/h. When neutron production is halted, the bunker must be accessible for hands-on maintenance operations. Further, these two requirements form the cause for the assessments reported herein of residual dose rates caused by the monolith shield plug and residual dose rates in the bunker. The monolith shield plug was shown to not produce significant dose rates inside the bunker after a 20-year lifetime, and the residual dose rates inside the bunker for the case of an operating beamline were shown to reasonably allow for hands-on maintenance. These calculations are based on preliminary design models of the relevant systems. Additionally, an example showing the significance of considering neutron supermirror physics in transport calculations that track nuclide production and destruction rates to produce gamma sources for residual dose rate calculations is included. The example shows that if neutron supermirror physics is not considered, dose rate fields may be significantly underpredicted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Advanced radiator systems for space power

Space power systems generating powers of 1 MWe and higher will require new approaches in radiator design in order to reject large waste heat loads without the unmanageable weight burden of conventional pumped-loop radiator systems. This paper discusses recent design concepts for radiator systems which have the potential for reducing radiator mass by as much as an order of magnitude below the mass of conventional systems. These advanced concepts, including the heat pipe radiator, particle (dust and droplet) radiators, moving belt radiator, rotating membrane radiator, and several interesting variations of these, achieve low mass by reducing the armor requirement for protection against micrometeoroids. The design and performance of each of these concepts is discussed, along with technical issues which must be addressed to bring these concepts to fruition.

Mattick, A. T.↗