Search NASA⌕ Search

SEARCH · Search NASA

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Measurements of the atmospheric neutron leakage rate

The atmospheric neutron leakage rate in the energy range from 0.01 to 10,000,000 eV has been measured as a function of latitude, altitude, and time with a neutron detector on board the Ogo 6 satellite. The latitude dependence of the neutron leakage is in reasonable agreement with that predicted by Lingenfelter (1963) and Light et al. (1973) if the neutron energy spectrum has the shape calculated by Newkirk (1963). The change in the neutron latitude dependence with the cosmic ray modulation agrees with the predictions of Lingenfelter and Light et al. For several solar proton events enhancements were observed in the neutron counting rates at lambda greater than or equal to 70 deg. Such events, however, provide an insignificant injection of protons at E less than or equal to 20 MeV into the radiation belts. An isotropic angular distribution of the neutron leakage in the energy range from 0.1 keV to 10 MeV best fits the observed altitude dependence of the neutron leakage flux.

Lockwood, J. A.↗

Hubble Space Telescope far-ultraviolet imaging of M31, M32, and NGC 205

Hubble Space Telescope (HST) Faint Object Camera (FOC) f/48 images of M31, M32, and NGC 205 (field of view 23 sec x 23 sec with 0.45 sec pixel size) are analyzed as observed through the combined UV filters F150W and F130LP. The absolute calibration of the data and the internal disagreement between observed and expected count rates in the UV region lead us to suggest that the filter combination F150W+F130LP suffers from a 5 times degraded UV sensitivity. A corrected efficiency curve is construced using the UV/optical spectral energy distributions of these three galaxies, which is consistent with all of the data analyzed here. Eighty-one individual stars are detected in M31, 10 stars in M32, and 78 stars in NGC 205. Comparisons with other UV images and optical images indicates that these stars are hot, UV-bright stars, even though our corrected efficiency curve suggests that flux from 1200-2450 A contributes only 7% of the counts in M32, 19% in M31, and 60% in NGC 205. The complex nucleus of M31 as seen by Lauer et al. (1993) is confirmed; M32 has a generally smooth appearance and NGC 205 is dominated by a UV-bright, somewhat resolved nucleus. Analysis of these data is done through the new, extensive stellar isochrones of Bertelli et al. (1994) and the population synthesis models of Bressan, Chiosi, and Fagotto (1994). This analysis shows that high-metal stars (Z greater than 0.05) evolve into UV-bright stars (P-EAGB, H-HB, and AGB-manque stars) that are less luminous and cooler but are significantly longer lived than the P-AGB stars produced by stars with Z less than 0.05. Moreover, the proportion of P-EAGB, H-HB, and AGB-manque stars is also a function of age, with older stars of fixed mean metallicity having a higher proportion than younger stars. Hence, with either metallicity or age differences as an interpretation of the line-strength luminosity correlation for ellipticals, the high-metallicity 'tail' of the stellar content of a galaxy can produce far-UV flux in much greater proportion than its actual proportion of galaxy mass. The resulting model of the sources of far-UV flux is inherently composite, with the total UV flux from a stellar population both rapidly increasing and changing its mean spectrum with increasing mean metallicity (or mean age). This model is consistent with several pieces of observational evidence.

Bertola, F.↗

Development of microchannel plates in advanced wind-tunnel instrumentation

Microchannel plate (MCP) electron multiplier dynamic range has been increased 3 to 4 orders of magnitude at ambient temperatures, through enhanced input count rate capability and reduced background or 'dark' noise. The previous upper limit of roughly 10(exp 7) - 10(exp 8) cm(exp -2)s(exp -1) at ambient has been extended to levels approach 10(exp 10) cm(exp -2)s(exp -1) under continuous dc operation. The lower limit, previously set by an irreducible background component (approximately 0.6 cm(exp -2)s(exp -1)), has been lowered to the cosmic ray limit of .01 cm(exp -2)s(exp -1). The high end improvement was achieved by conductively cooling a very low resistance MCP by bonding it to a heat sink, while maintaining pulse-counting operation with multianode readouts. The low-end improvement was achieved by removing all radioisotopes from the MCP matrix glass. The detectors will benefit optical and mass spectrometry, flow visualization, plasma diagnostics, magnetometry, and other high signal flux applications. Very low MCP background noise will benefit X-ray and UV astronomy, medical imaging, trace isotope mass spectrometry, and other applications where the signal flux is often extremely low.

Feller, W. Bruce↗

Observation of the Radiation Environment and Solar Energetic Particle Events in Mars Orbit in May 2018- June 2022

Epithermal Neutron Detector (FREND). Here we present results from measurements of the charged particle fluxes, dose rates and estimation of dose equivalent rates at ExoMars TGO Mars science orbit, provided by Liulin-MO from May 2018 to June 2022. The period of measurements covers the declining and minimum phases of the solar activity in 24th solar cycle and the rising phase of the 25th cycle. Compared are the radiation values of the galactic cosmic rays (GCR) obtained during the different phases of the solar activity. The highest values of the dose rate and flux from GCR are registered from March to August 2020. At the minimum of 24th and transition to 25th solar cycle the dose rate from GCR is 15.9 ± 1.6 µGy h−1, particle flux is 3.3 ± 0.17 cm−2 s−1, dose equivalent rate is 72.3 ± 14.4 µSv h−1. Since September 2020 the dose rate and flux of GCR decrease. Particular attention is drawn to the observation of the solar energetic particle (SEP) events in July, September and October 2021, February and March 2022 as well as their effects on the radiation environment on TGO during the corresponding periods. The SEP event during15–19 February 2022 is the most powerful event observed in our data. The SEP dose during this event is 13.8 ± 1.4 mGy (in Si), the SEP dose equivalent is 21.9 ± 4.4 mSv. SEP events recorded in Mars orbit are related to coronal mass ejections (CME) observed by SOHO and STEREO A coronagraphs. Compared are the time profiles of the count rates measured by Liulin-MO, the neutron detectors of FREND and neutron detectors of the High Energy Neutron Detector (HEND) aboard Mars Odyssey during 15–19 February 2022 event. The data obtained is important for the knowledge of the radiation environment around Mars, regarding future manned and robotic flights to the planet. The data for SEP events in Mars orbit during July 2021-March 2022 contribute to the details on the solar activity at a time when Mars is on the opposite side of the Sun from Earth.

Jordanka Semkova↗

Laboratory Investigation of the Effect of Venusian Weathering on Mineral Spectra

Introduction: The recent selection of two missions to Venus has renewed the importance of deter-mining weathering reactions between minerals and the Venusian atmosphere, and the spectral signatures of minerals before, during, and after these reactions. The rate at which weathering reactions progress also constrain show long unstable minerals will be present on the surface (e.g., [1]), and enables the use of mineralogy as a constraint on surface age(e.g., [2-3]).In order to gain an understanding of how mineral compositions and spectra change with weathering, we have begun conducting experiments in a 1 atm experimental setup at Wesleyan University. This setup exposes minerals to the temperature and most abundant gases of the Venus atmosphere (CO2, SO2, N2).We conducted initial experiments using biotite, calcite, and montmorillonite in order to test our methodology with minerals that may be relevant to recording the history of water on Venus. Methods: Experiments were conducted in Thermo Fisher Scientific Lindberg/Blue M Mini-Mite horizontal tube furnaces at Wesleyan University. Experiments used natural mineral chips and powders, and were conducted at 1 atmosphere and 460 °C under pre-mixed gases provided by Air Gas(Table 1). The furnaces are set up in a flow through configuration so that solid samples are exposed to a fixed gas composition, and quartz glass process tubes were used in all experiments (1/4” diameter for experiment V4, ½” diameter for all others). These conditions were maintained for the du-rations listed in Table 1, at which point the furnace was turned off with gas flowing until the sample was cool enough to extract under N2and be placed in a desiccator for storage. Run products were carbon coated and examined using a Hitachi SU5000 Field Emission Gun Scanning Electron Microscope (SEM) equipped with an EDAX Octane Pro EDS detector located at Wesley-an University. Visible-Near Infrared Spectroscopy (VNIR) analysis was performed on powdered samples under a nitrogen atmosphere using an ASD Fieldspec Proover the 350-2500 nm range. Powdered mineral samples were milled to a particle size of < 45μm and were spiked with an internal standard (Al2O3, corundum) to obtain quantitative mineralogy. Samples were analyzed using a Panalytical X’Pert pro X-ray Diffractometer (XRD), with an X’Celerator high speed detector and Co Kα radiation, with data collected at a step size of 0.02 ̊/minute step counting rate from 2 to 80 degrees 2θ at 45 mA/40kV in the X-ray Diffraction Laboratory located at NASA Johnson Space Center. Materials Data Inc (MDI) software suite, JadeTMv9 was used for Rietveld refinement to determine phase abundances and mineral identification by comparing XRD patterns to International Center for Diffraction Data (ICDD) database patterns. Table 1: Experimental matrix. Experiment Name Duration (Days)Gas Com-position (trace gas)MineralsV487SO2/N2(1.4%)Montmorillonite, biotiteV519SO2/N2(1.4%)CalciteV619CO2/SO2/N2(1.4% SO2, 2.1% N2)Montmorillonite, biotiteV828SO2/N2(1.4%)Biotite, calcite Results: Calcite. In both experiments, calcite was exposed to the SO2/N2gas mixture, and in both experimental run products, XRD analysis detected anhydrite, which is consistent with EDS measurements conducted in the SEM. The XRD analyses show greater amounts of anhydrite present after 28 days than 19, suggesting the calcite reaction progressed further given longer duration. Grain surface morphology as seen in the SEM also shows secondary mineral growth (Fig. 1). VNIR spectra show no change, as expected since anhydrite lacks spectral features in this wavelength range. Montmorillonite. Montmorillonite was exposed to two different gas mixtures, the SO2/N2mix and CO2/SO2/N2mix over different durations (87 and 19 days, respectively). VNIR analyses of both run products show a reduction in the 1441and1910 nm water features as well as a shift of the 1411 and 2011 nm features to shorter wavelengths that may indicate re-structuring in the crystal lattice and the production of amorphous phases [4]. XRD results are consistent with this, showing a shift of the 001 peak from 15Åto 10Åin both run products. The amount of X-ray amorphous material in the montmorillonite run products was greater than that present in the unreacted clay, being the greatest in the 87 day V4 experiment. No other secondary phases were detected in the run products, however sulfur was present in EDS analyses of powder samples.

A R Santos↗

Observations of the Van Allen Radiation Regions During August and September 1959

An integrating ionization chamber and a single Geiger counter were flown on United States satellite Explorer VI in an elliptical orbit extending to 48,000 km. In addition to the Van Allen inner zone and the great outer zone, a stable and distinct intermediate zone was detected throughout August and September 1959. The outer-zone intensity showed a large decrease following the sudden commencement of a geomagnetic storm. Later in the storm the outer zone increased to much in excess of its prestorm level. During stable periods the outer zone was fairly constant and less intense than it had been observed to be with Pioneer III or Pioneer IV or the first Soviet cosmic rocket. Cosmic-ray background counting rates were reached on most passes in August and Septmeber near apogee of the satellite. The radiation ?dumped? from the outer zone during the geomagnetic storm fits very well with the intensity and latitude distribution required to account for balloon observations of auroral X rays made during the IGY period. This paper is based on preliminary analysis of Explorer VI data.

Arnoldy, R. L.↗

Observational work on cosmic gamma rays

Cosmic gamma rays observation by balloon flight and satellite with scintillation detector, tabulating counting rates in pulse height channels relative to Crab Nebula

Clark, G. W.↗