Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibrating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

MODIS Reflective Solar Bands Calibration Improvements for Collection 7

Calibration of Terra and Aqua MODIS reflective solar bands (RSB) has evolved significantly since the launch of the first MODIS instrument on the Terra satellite more than 21 years ago. In NASA’s current Collection 6 and 6.1 Level 1B products (C6/C6.1 L1B), the RSB calibration algorithm continues to rely primarily on the onboard solar diffuser to calibrate the instrument gain. Lunar observations are used to track on-orbit changes in the response versus scan angle (RVS), and data from pseudo-invariant desert sites are used to apply adjustments to the gain and RVS calibration for select bands. The resulting reflectance products have in general shown a very stable performance. In recent years, some performance degradation has been noted for a few bands and algorithm changes have been tested to further improve the calibration accuracy for the upcoming Collection 7 (C7) L1B reprocess. In this paper, we present the MODIS RSB calibration improvements that will be included in C7. Major improvements include: applying polarization correction to the desert data before using it to generateRVS for Terra bands 8, 9, 3, and 10; using ocean scene data and an interband calibration approach to correct for long-term drift of Terra bands 11 and 12; applying an updated crosstalk correction to Terra SWIR bands over the entire mission; and using data from deep convective clouds in Terra SWIR band calibration, including the addition of time-dependent RVS for bands 5 and 26. All other minor calibration changes are also covered. Overall, the reflectance differences at nadir between C6.1 and C7 are within a few percent, though the differences increase in some cases at large scan angles. The Terra visible (3, 8-12) and SWIR bands (5-7, 26) have the most significant improvements. For all other Terra bands and all Aqua bands, the C7-C6.1 differences are mostly within 1%

MODIS↗

MODIS Reflective Solar Bands Lunar Calibration Update and Improvements

The MODerate resolution Imaging Spectroradiometer (MODIS) instruments on-board the Terra and Aqua spacecrafts were launched on December 18, 1999 and May 4, 2002, respectively. Each instrument has been scheduled to view the Moon through its Space View (SV) port approximately once per month in order to monitor the long-term radiometric stability of their reflective solar bands (RSB). The lunar calibration has played a key role in tracking the change in the response versus scan angle (RVS) of the instrument’s scan mirror, which is an essential part of the RSB calibration. The lunar irradiance observed by MODIS depends on the view geometry and it is crucial to remove the geometric effects in order to derive accurate RSB calibration coefficients. With a scheduled roll maneuver, the lunar phase angles are kept in a narrow range of 1° for each MODIS instrument such that the impact of these geometric effects is minimized. Nevertheless, it remains a challenge to completely remove the impact of geometric effects in the calibration coefficients derived from the lunar observations, considering the high expectations for the accuracy and quality of the results. In the current MODIS lunar calibration, the geometric effects on the lunar irradiance are corrected by the RObotic Lunar Observatory (ROLO) model. The overall relative uncertainty of the ROLO model for the MODIS calibration has been assessed to be about 1% in the selected lunar phase angle range of 1°. It could be as large as 4% beyond this small phase angle range, especially for the shortest wavelengths. This uncertainty induces noticeable oscillations in the calibration coefficients derived from the lunar observations. We developed a simple lunar model, which is based on MODIS lunar measurements, derived from scheduled lunar observations, as well as those obtained from intrusion of the Moon in the SV, referred to as unscheduled lunar observations, in the time period from 2005 to 2012. Here, the scheduled lunar observations for the entire mission are reprocessed with the new lunar model applied to correct the view geometry effects for each MODIS instrument. New calibration coefficients for the RSBs are calculated. We show that oscillations and noise in the derived lunar calibration coefficients are significantly reduced for both MODIS instruments.

Terra↗

Deep Convective Cloud Calibration Sensitivity Studies in Support of Radiometrically Scaling GEO Imagers With VIIRS

The NASA CERES SYN1deg product provides the scientific community regional hourly TOA and surface broadband fluxes and clouds. For consistent geostationary (GEO) derived fluxes and clouds the GEO imagers are radiometrically scaled to the Aqua-MODIS calibration reference. The CERES project utilizes GEO and MODIS analogous channel coincident, collocated, and co-angled radiance pairs as the primary method to inter-calibrate the GEO imagers. Deep convective clouds (DCC) are bright tropical, near Lambertian, top of atmosphere pseudo invariant Earth targets that do not rely on coincident radiance pairs to radiometrically scale sensors to a common calibration reference. DCC pixels are identified by cold IR window channel brightness temperatures (BT). Successful DCC inter-calibration relies on sufficient sampling of comparable identified DCC pixels between sensors. The DCC identification thresholds, pixel resolution, local time, and geographical sampling should be consistent between sensors. Over 20 GEO imagers during the span of the CERES record have various visible and IR pixel resolutions. Unlike the MODIS and VIIRS imagers, where the visible and IR pixel resolutions are similar, the GEO visible pixel resolution is much finer than the IR pixel resolution. The study will examine the pixel resolution impact on the DCC calibration methodology. The resulting DCC calibration coefficients can be validated against the sensor pair calibration methodology. Accounting for the DCC calibration imager resolution differences will allow the CERES project to utilize the future CLARREO observations as the calibration reference for all GEO, MODIS, and VIIRS imagers across the CERES record.

Conor Haney↗

The NASA OBPG 2020 On-Orbit Calibration of SNPP VIIRS for Ocean Color Applications

The NASA Ocean Biology Processing Group (OBPG) has continued monitoring the SNPP VIIRS on-orbit calibration for bands M1-M11 over its mission to optimize the calibration for ocean color applications. The OBPG has recently implemented several changes to the calibration scheme: using solar-derived f-factors to detrend the lunar observations; using long-term exponentials of time as basis vectors (along with libration angles) for radiometric fits to any resulting lunar temporal drifts; deriving gain adjustments to the solar f-factors from these exponentials; and deriving gain adjustments due to modulated RSRs outside of the solar/lunar calibration using TOA reference spectra. These calibration changes minimize the impact of uncertainties in any one component of the calibration on the derived f-factors. The final f-factors incorporate VIIRS solar diffuser measurements, h-factor BRDF corrections, lunar-derived gains, and modulated RSR gains. The combined BRDF corrections, lunar gain adjustments, and mRSR gain adjustments define effective h-factors for each band. The improvements in the on-orbit calibration are validated by evaluation of globally-derived anomaly plots of remote sensing reflectance for the ocean color bands. The ultimate goal of the OBPG calibration effort is incorporation of a consistent SNPP VIIRS ocean color data set into the NASA multi-mission ocean color climate data record.

VIIRS↗

Independent Calibration Approach for the CLARREO Pathfinder Mission

A CLARREO (Climate Absolute Radiance and Refractivity Observatory) Pathfinder (CPF) mission has been funded to demonstrate retrieval of SI-traceable spectral reflectance with absolute uncertainty <0.3% (k=1). The mission consists of a Reflected Solar spectrometer that will be hosted on the International Space Station (ISS) in the 2023 timeframe and rely on a ratioing radiometer approach to retrieve the unprecedented accuracy. Demonstrating that the accuracy is achieved through an Independent Calibration effort similar in philosophy to the efforts in metrology laboratories relying on multiple, independent measurements to improve credibility for a sensor’s absolute and relative uncertainty error budgets. These measurements use different traceability paths and multiple instrument approaches and CPF’s Independent Calibration will be similar in this regard. The Independent Calibration relies on a pre-launch absolute radiometric calibration obtained from additional testing done after instrument thermal-vacuum (TVAC) testing. The added radiometric calibration is combined with a high fidelity instrument model to provide an on-orbit radiometric calibration independent from the ratioing radiometer approach. The current work describes the post-TVAC testing portion of the CPF Independent Calibration Plan and the Independent Model Development as well as planned on-orbit Evaluation of the Independent Calibration.

CLARREO Pathfinder↗

Aqua MODIS: 20 Years of On-orbit Calibration and Performance

Since its launch in May 2002, Aqua MODIS has successfully operated for more than 20 years and has continuously generated a wide range of data products that have enabled and supported the remote sensing community and users worldwide for their studies of the Earth’s system by monitoring changes in its key environmental parameters. Although Aqua MODIS, designed with a lifetime requirement of 6 years, is currently operated in its extended mission phase, it continues to make high quality global observations of the Earth’s surface via its 36 spectral bands that cover wavelengths from visible to long-wave infrared. To date, all instrument on-board calibrators (OBC) remain capable of performing their design functions, providing various calibration data sets to help monitor on-orbit changes in sensor responses and performance characteristics. In addition to the OBC, regularly scheduled lunar observations and select Earth-view targets are used extensively to support sensor on-orbit calibration, especially for the calibration of the visible channels (or bands). In this paper, we provide an overview of Aqua MODIS on-orbit calibration activities and methodologies for both reflective solar bands (RSB) and thermal emissive bands (TEB), illustrate its on-orbit performance over the past 20 years using examples derived from OBC measurements, lunar observations, and Earth-view response trends, and describe various calibration improvements made over its entire mission. We focus on key issues identified since launch, such as solar diffuser degradation, electronic crosstalk, and on-orbit changes in sensor response versus scan-angle, along with approaches and strategies developed to mitigate their impact on sensor calibration quality. Also discussed in this paper are some of the key calibration enhancements incorporated recently in the Collection 6.1 and the upcoming Collection 7 Level-1B algorithms.

Polarization↗

Overview of SIM wide angle astrometric system calibration strategies

This paper summarizes two very different strategies envisioned for calibrating the systematic field dependent biases present in the Space Interferometry Mission (SIM) instrument. The Internal Calibration strategy is based on pre-launch measurements combined with a set of on orbit measurements generated by a source internal to the instrument. The External Calibration strategy uses stars as an external source for generating the calibration function. Both approaches demand a significant amount of innovation given that SIM's calibration strategy requires a post-calibration error of 100picometers over a 15 degree field of regard while the uncalibrated instrument introduces 10's-100's of nanometers of error. The calibration strategies are discussed in the context of the Wide Angle Astrometric mode of the instrument, although variations on the Internal Calibration Strategy may be used for doing Narrow Angle Astrometry.

calibration SIM optical modeling↗

On the Long-Term Stability of Microwave Radiometers Using Noise Diodes for Calibration

Results are presented from the long-term monitoring and calibration of the National Aeronautics and Space Administration Jason Microwave Radiometer (JMR) on the Jason-1 ocean altimetry satellite and the ground-based Advanced Water Vapor Radiometers (AWVRs) developed for the Cassini Gravity Wave Experiment. Both radiometers retrieve the wet tropospheric path delay (PD) of the atmosphere and use internal noise diodes (NDs) for gain calibration. The JMR is the first radiometer to be flown in space that uses NDs for calibration. External calibration techniques are used to derive a time series of ND brightness for both instruments that is greater than four years. For the JMR, an optimal estimator is used to find the set of calibration coefficients that minimize the root-mean-square difference between the JMR brightness temperatures and the on-Earth hot and cold references. For the AWVR, continuous tip curves are used to derive the ND brightness. For the JMR and AWVR, both of which contain three redundant NDs per channel, it was observed that some NDs were very stable, whereas others experienced jumps and drifts in their effective brightness. Over the four-year time period, the ND stability ranged from 0.2% to 3% among the diodes for both instruments. The presented recalibration methodology demonstrates that long-term calibration stability can be achieved with frequent recalibration of the diodes using external calibration techniques. The JMR PD drift compared to ground truth over the four years since the launch was reduced from 3.9 to - 0.01 mm/year with the recalibrated ND time series. The JMR brightness temperature calibration stability is estimated to be 0.25 K over ten days.

noise diode (ND)↗

Comparison of Spectral Radiance Calibration Techniques Used for Backscatter Ultraviolet Satellite Instruments

Methods for determining the absolute radiometric calibration sensitivities of backscatter ultraviolet (BUV) satellite instruments are compared as part of an effort to minimize pre-launch calibration errors. An internally illuminated integrating sphere source has been used for the Shuttle Solar BUV (SSBUV), Total Ozone Mapping Spectrometer (TOMS), Ozone Mapping Instrument (OMI), and Global Ozone Monitoring Experiment 2 (GOME-2) using standardized procedures traceable to national standards. These sphere-based sensitivities agree to within three percent [k equals 2] relative to calibrations performed using an external diffuser illuminated by standard irradiance sources, the customary radiance calibration method for BUV instruments. The uncertainty for these calibration techniques as implemented at the NASA Goddard Space Flight Centers Radiometric Calibration and Development Laboratory is shown to be 4 percent at 250nm [k equals 2] when using a single traceable calibration standard. Significant reduction in the uncertainty of nearly 1 percent is demonstrated when multiple calibration standards are used.

residual errors↗

Detection of Unexpected High Correlations between Balance Calibration Loads and Load Residuals

An algorithm was developed for the assessment of strain-gage balance calibration data that makes it possible to systematically investigate potential sources of unexpected high correlations between calibration load residuals and applied calibration loads. The algorithm investigates correlations on a load series by load series basis. The linear correlation coefficient is used to quantify the correlations. It is computed for all possible pairs of calibration load residuals and applied calibration loads that can be constructed for the given balance calibration data set. An unexpected high correlation between a load residual and a load is detected if three conditions are met: (i) the absolute value of the correlation coefficient of a residual/load pair exceeds 0.95; (ii) the maximum of the absolute values of the residuals of a load series exceeds 0.25 % of the load capacity; (iii) the load component of the load series is intentionally applied. Data from a baseline calibration of a six-component force balance is used to illustrate the application of the detection algorithm to a real-world data set. This analysis also showed that the detection algorithm can identify load alignment errors as long as repeat load series are contained in the balance calibration data set that do not suffer from load alignment problems.

strain-gage balance↗

Evaluation of Long-Term Calibrations of the AVHRR Visible Radiances

Two systematic calibrations have been compiled for the visible radiances measured by the series of AVHRR instruments flown on the NOAA operational polar weather satellites: one by the International Satellite Cloud Climatology Project (ISCCP), anchored on NASA ER-2 underflights in the 1980s and early 1990s and covering the period 1981-2009, and one by the PATMOS-x project, anchored on comparisons to the MODIS instruments on the Aqua and Terra satellites in the 2000s and covering the period 1979-2010 (this result also includes calibration for the near-IR channels). Both methods have had to extend their anchor calibrations over a long series of instruments using different vicarious approaches, so a comparison provides an opportunity to evaluate how well this extension works by cross-checking the results at the anchor points. The basic result of this comparison is that for the ''afternoon'' series of AVHRRs, the calibrations agree to within their mutual uncertainties. However, this retrospective evaluation also shows that the representation of the time variations can be simplified. The ISCCP procedure had much more difficulty extending the calibration to the ''morning'' series of AVHRRs with the calibrations for NOAA-15 and NOAA-17 exceeding the estimated uncertainties. Given the general agreement, a new calibration for all AVHRR visible radiances (except TIROS-N, NOAA-6, NOAA-19, and MetOp-A) is proposed that is based on the average of the best linear fits to the two time records. The estimated uncertainty of these calibrations is 63% absolute (scaled radiance units).

Advanced Very High Resolution Radiometer↗

Application of quasi-deep convective clouds method for MODIS and VIIRS TEB calibration assessments

A technique to use deep convective clouds (DCC) and quasi-DCC (qDCC) for the calibration assessment of the thermal emissive bands (TEB) on remote sensing instruments has proven feasible. The Terra and Aqua MODIS and S-NPP and NOAA-20 VIIRS TEB calibration uses a nonlinear algorithm whose nonlinear coefficients rely on on-orbit black body (BB) warm-up and cool-down (WUCD) activities for updates. However, the limited BB temperature range affects the calibration’s uncertainty. The DCC core, one of the coldest Earth scenes, is suitable for MODIS calibration assessments; more specifically, for the evaluation of the offset effect in its TEB quadratic calibration function. Moreover, nighttime qDCC measurements provide the advantage of removing solar reflectance effects, thus enhancing the assessment’s accuracy for the midwave infrared TEB. In this paper, the qDCC method is applied to the Terra MODIS and VIIRS TEB. Their stabilities are assessed using long-term DCC and qDCC trending measurements over the instruments’ entire missions. The measurements from bands with an approximately 11-μm wavelength are used to identify the DCC pixels. MODIS band31 (~ 11m) has demonstrated stable performance and accurate calibration for both instruments throughout their respective missions. MODIS band31 can therefore be used as a reference for the other TEB. Furthermore, it also allows for a Terra and Aqua MODIS TEB cross-comparison. The assessment results, along with the calibration uncertainty and Level 1B product impact modeling, can be quite helpful for calibration improvements.

MODIS↗

MODIS TEB Calibration Algorithm Improvements for Future L1B Collection

Terra and Aqua MODIS have provided continuous global observations for scientific applications for more than 20 and 18 years, respectively. The radiometric calibration of the MODIS thermal emissive bands (TEB) is based on a quadratic approximation of the instrument response. The calibration coefficients look-up tables (LUTs) are updated using the response of the MODIS on-board blackbody (BB)with the response background subtracted by space view. The quarterly on-board BB warm-up and cool-down activity temperature ranges from 270 K to 315 K, and the derived offset has a relatively large uncertainty. Electronic cross-talk, an artifact that affects both instrument calibration and Earth view (EV) radiance retrievals, is corrected based on lunar observations. Calibration assessments using EV observations (e.g. ocean, desert, Antarctic Dome Concordia, and deep convective clouds) provide useful information to evaluate the impact of the Terra safe mode (February 2016) and Aqua MODIS formatter reset (January 2018) events on both MODIS instruments. This study focuses on the TEB radiometric calibration algorithm improvements for future collections based on calibration assessments using EV measurements and analytical modeling. Measurement stability and consistency over specific Earth scenes with a wide temperature range, as well as their brightness temperature (BT) dependency, are used for bias estimations in the calibration coefficients. Calibration coefficients are derived and updated after adjusting the current fitting algorithm. Thereafter, using the test LUTs, their impact on the Level 1B (L1B) data for different EV scenes is analyzed.

MODIS↗

Overview of GSICS visible calibration methods.

Global Space-based Inter-Calibration System (GSICS) is an international collaborative effort initiated in 2005 by the World Meteorological Organization (WMO) and the Coordination Group for Meteorological Satellites (CGMS) to 1-monitor, 2-improve and 3-harmonize the quality of observations from operational weather and environmental satellites of the Global Observing System (GOS). GSICS aims at ensuring consistent accuracy among space-based observations worldwide for climate monitoring, weather forecasting, and environmental applications by 1-monitoring instrument performance, 2-operational inter-calibration of satellite instruments, 3-radiometrically scaling observations to absolute reference standards, 4-recalibration of archived datasets. Although many of the GSIC visible inter-calibration methods are based on medium pixel-level imagers such as MODIS, VIIRS, AVHRR, and geostationary sensors, the methods are applicable to high spatial resolution imagery such as Landsat. For sensor inter-calibration efforts, coincident ray-matched reflectance pairs are used to transfer the calibration from the reference to the target instrument. Spectral band adjustment factors (SBAF) are applied to account for any spectral band differences. For sensor stability monitoring, PICS, deep convective cloud (DCC) and polar ice Earth viewed targets are utilized. GSICS uses the moon for stability monitoring by using the GSICS Implementation of the USGS Robotic Lunar Observatory (ROLO) model (GIRO). GSICS is looking forward to the launch of CLARREO on the international space station (ISS) in 2023. The CLARREO hyperspectral reflective solar band (RSB) sensor will establish an absolute calibration reference in space, which will characterize invariant targets and will inter-calibrate concurrent sensors. Examples of these calibration methods will be presented at the workshop.

Visible calibration methods↗

Application of Quasi-Deep Convective Clouds Method for VIIRS and MODIS TEB Calibration Assessments

A technique that utilizes quasi-deep convective clouds (qDCC) for the calibration assessment of the thermal emissive bands (TEB) on remote sensing instruments has been proven viable. The Terra and Aqua MODIS and S-NPP and NOAA-20 VIIRS TEB calibration uses a nonlinear algorithm whose nonlinear coefficients rely on on-orbit blackbody (BB) warm-up and cooldown operations for updates. However, a limited BB temperature range affects the calibration’s accuracy particularly for cold scenes. The deep convective clouds (DCC) core, one of the coldest Earth scenes, is suitable for MODIS calibration assessments; more specifically, for the evaluation of the offset term’s effect in its TEB quadratic calibration function. Moreover, nighttime qDCC measurements provide with the advantage of removing solar reflectance effects during daytime, thus enhancing the assessment’s accuracy for the midwave infrared TEB. In this paper, this qDCC method is applied to the Terra MODIS and VIIRS TEB; and their stabilities are assessed using long-term qDCC trending measurements over the instruments’ missions. The measurements from bands with an 11-μm wavelength are used to identify the DCC pixels. The 11-μm bands, MODIS band 31 and VIIRS bands M15 and I5, are stable throughout the MODIS and VIIRS missions and have shown excellent calibration accuracy and noise performance. Hence, using these bands as references, a normalization method is employed to enhance the accuracy of the stability and consistency assessments. The S-NPP VIIRS TEB show stable trends over the instrument’s mission. The S-NPP-to-N20 VIIRS comparison shows their TEB measurements are consistent over qDCC. The Terra MODIS TEB also show stable performance – except for bands 27, 29, and 30. Terra MODIS band 30 shows a large downward trend throughout the mission, while bands 27 and 29 show slight, upward drifts. Lastly, a calibration correction using qDCC assessments is discussed and intended to be used in a future calibration algorithm collection.

MODIS↗

Impact of Satellite Orbit Drift on Modis Earth Scene Observations Used in Calibration of the Reflective Solar Bands

After more than 20 years in orbit, NASA’s Terra and Aqua satellites have both started drifting away from their historically maintained orbits. The MODIS instruments on Terra and Aqua continue to collect valuable Earth observation data, but the changing orbits present a challenge for maintaining accurate calibration. The MODIS reflective solar bands (RSB), spanning the wavelength range from 412 nm to 2130 nm, are calibrated on orbit using a combination of regular data collections from an on-board solar diffuser, the Moon, and pseudo-invariant Earth scenes. Starting in the Collection 6 Level 1B (L1B) data products, the RSB calibration began using data from desert targets for a few of the visible bands to better track changes in the response versus scan angle that could not be captured by the on-board calibration. The use of Earth scene data has been extended recently for Terra MODIS calibration in Collection 6.1 (C6.1) and the upcoming Collection 7 (C7) L1B to also include data from ocean scenes and deep convective clouds (DCC). Drifts in both the orbit inclination and ground track of Terra and Aqua lead to changes in the solar illumination angles and satellite view angles of the Earth scenes. We discuss how these orbital changes impact the desert and DCC targets used for MODIS RSB calibration and present the accompanying changes made to our C6.1 and C7 calibration algorithms. We also discuss remaining future challenges, such as better characterization of bi-directional reflectance distribution functions, and possible alternative calibration strategies.

MODIS↗

Improvements of the Load Schedule for the Machine Calibration of a Strain-Gage Balance

The load schedule for the calibration of a six-component force balance in a calibration machine was improved. Now, single-component loads are repeated in regular intervals during the calibration. This approach has several advantages. First, the number of single-component loads increases to about twenty-two percent of all loads and load combinations. Consequently, more accurate numerical estimates of the primary bridge sensitivities can be obtained if global regression is used for the analysis of the calibration data. In addition, single-component repeats make it possible to track the stability of the applied loads during the calibration process. Finally, interactions of single-component repeats can be compared with interactions that are observed during the application of manual loads to the balance. Machine calibration and manual data sets of two force balances are used to illustrate benefits of the new load schedule. It is shown in the examples how differences between the observed interactions of machine calibration and manual data can be quantified. The suggested improvements can also be implemented in the load schedule for the machine calibration of a moment or direct-read balance as long as single-component loads are included that are described in the design load format of the balance.

wind tunnel test↗

Initial On-Orbit Spectral Calibration of the PACE Ocean Color Instrument

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission Project Science Team has used Ocean Color Instrument (OCI) measurements of Fraunhofer lines in spectra of sunlight reflected by the solar diffuser and measurements of atmospheric absorption bands in cloudtop and ocean spectra to characterize the spectral calibration of OCI on orbit. Multiple lines have been analyzed for both the ultraviolet to visible (UVVIS, 340−607 nm) and visible to near-infrared (VISNIR, 597−897 nm) grating spectrographs. The spectrographs yield hyperspectral observations with 5 nm bandwidths and 0.625 nm sampling intervals. The on-orbit observations have been compared with the prelaunch spectral calibration of OCI performed by the Goddard Laser for Absolute Measurement of Radiance (GLAMR) during thermal vacuum testing to track any changes in the calibration since launch. The calibration analyzed the line positions and strengths for the Fraunhofer lines for each spectrograph by comparing the solar spectra measured by OCI with predicted solar spectra derived from the solar reference spectrum and the BRDF of the solar diffuser, convolved with the OCI relative spectral responses. The calibration also compared the line positions of the atmospheric absorption bands with the model transmissions used by the PACE Project. The line position comparisons show that the root mean square (RMS) spectral difference between the measured and predicted spectra is 0.15 nm, the average spectral shift is 0.062 nm, and the residual spectral dispersion over the wavelength range of the Fraunhofer lines is 0.17 nm. All three estimates of the spectral accuracy of OCI meet the instrument functional requirement of a spectral accuracy of 0.5 nm and are well within the 0.625 nm sampling interval of the data. The line strength comparisons between measured and predicted spectra are essentially the same. These results show that the spectral calibration of OCI on orbit has not drifted since the prelaunch calibration of OCI by GLAMR and that the on-orbit spectral calibration of OCI is stable over time. These results also provide a baseline for monitoring the future spectral performance of OCI on orbit.

Radiometric Calibration↗