Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cherenkov”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Diagnostics of Fast Electrons within Castor Tokamak by Means of a Modified Cherenkov-Type Probe

The paper reports on experimental studies performed within the CASTOR tokamak, which was operated at IPP in Prague, Czech Republic, during the last experimental campaign carried out in autumn 2006. The main aim was to implement a new diagnostic technique for measurements of energetic (>80 keV) electrons within the tokamak edge plasma region. The technique was based on the use of a Cherenkov-type probe similar to the first prototype detector, which was tested during the previous experiments with the CASTOR device. In particular, the distributions of fast electrons in a standard scenario at different values of plasma current I{sub p}, and toroidal magnetic field B{sub T} are determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cherenkov Detector For Measurements Of Fast Electrons In CASTOR-Tokamak

The paper reports on capabilities of an improved version of the Cherenkov detector designed for measurements of fast electrons. The described technique enables the identification of electron beams, the measurements of their temporal characteristics, as well as the estimation of their spatial properties to be performed. Results obtained in the last experimental campaign with the CASTOR facility show good measuring capabilities of such a detection system. The radial distributions of fast-electron streams at different plasma densities, as well as the electron fluency dependences on discharge currents and toroidal magnetic fields are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel background reduction strategy for high level triggers and processing in gamma-ray Cherenkov detectors

Gamma ray astronomy is now at the leading edge for studies related both to fundamental physics and astrophysics. The sensitivity of gamma detectors is limited by the huge amount of background, constituted by hadronic cosmic rays (typically two to three orders of magnitude more than the signal) and by the accidental background in the detectors. By using the information on the temporal evolution of the Cherenkov light, the background can be reduced. We will present here the results obtained within the MAGIC experiment using a new technique for the reduction of the background. Particle showers produced by gamma rays show a different temporal distribution with respect to showers produced by hadrons; the background due to accidental counts shows no dependence on time. Such novel strategy can increase the sensitivity of present instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cherenkov radiation of shear Alfven waves

A calculation is presented of the radiation pattern of shear Alfven waves excited by a burst of charged particles propagating along the confinement magnetic field. The characteristic wake patterns are obtained for the inertial and kinetic regimes of wave propagation. In the inertial regime, the waves are only excited by particles moving slower than the Alfven speed. The radiated wake exhibits an inverted V-shape due to the backward-wave nature of the modes. In the kinetic regime, particles moving faster as well as slower than the Alfven speed can radiate propagating modes. The super Alfvenic particles, however, excite modes with relatively short transverse scales. The motorboat type of wake of the kinetic modes is more typical of the Cherenkov process obtained in scalar dielectrics. The predictions are in agreement with experimental observations [B. Van Compernolle et al., Phys. Plasmas 13, 09112 (2006)] and computer simulations [F. S. Tsung et al., Phys. Plasmas 14, 042101 (2007)] in which a burst of fast electrons generated by resonant absorption in a magnetized plasma excites a pulse of large-amplitude Alfven waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Amplification of transition-Cherenkov terahertz radiation of femtosecond filament in air

The transition-Cherenkov terahertz radiation from a femtosecond laser filament in air is enhanced by three orders of magnitude in the presence of a longitudinal static electric field, while the radiation pattern and the polarization remain the same. An amplified longitudinal electron current inside the filament is responsible for this amplified terahertz emission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reversed Cherenkov radiation in a waveguide filled with anisotropic double-negative metamaterials

The physical properties of Cherenkov radiation (CR) are theoretically investigated for a charged particle traveling along the axis of a cylindrical waveguide filled with anisotropic double-negative metamaterials (DNMs). The reversed CR and CR conditions are obtained using analytical method. The influence of the particle velocity, the waveguide radius, and the constitutive parameters of the anisotropic DNMs are discussed. A numerical example illustrates that the total radiated energy increases with increasing particle velocity, the radiated energy spectral density has different poles at the different frequencies for different anisotropic DNMs when the loss of the anisotropic DNM is smaller, and when the radius has the same order as the operating wavelength, the influence of the waveguide radius on the total radiated energy is smaller on the whole. Since most of the metamaterials realized so far are anisotropic, our theoretical work based on anisotropic DNMs will be helpful for future experimental realizations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient Cherenkov emission of broadband terahertz radiation from an ultrashort laser pulse in a sandwich structure with nonlinear core

A scheme for efficient generation of broadband terahertz radiation by a femtosecond laser pulse propagating in a planar sandwichlike structure is proposed. The structure consists of a thin nonlinear core cladded with prisms made of a material with low terahertz absorption. The focused into a line laser pulse propagates in the core as a leaky or waveguide mode and emits Cherenkov wedge of terahertz waves in the cladding. We developed a theory that describes terahertz generation in such a structure and calculated spatial distribution of the generated terahertz field, its energy spectrum and optical-to-terahertz conversion efficiency. The developed theory predicts the conversion efficiency of up to several percent in a 1 cm long and 1 cm wide Si-LiNbO{sub 3}-Si sandwich structure with a 20 {mu}m thick nonlinear layer pumped by 8.5 {mu}J Ti:sapphire laser with pulse duration of 100 fs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Performances and Low Cost Front-End Electronics for the Cherenkov Telescope Array

The current Imaging Arrays of Cherenkov Telescopes (IACT) show that this technique is mature. Front-end electronics based on analogue pipelines become a popular readout solution. Slow noise and low power consumption ASICs were developed with improved dynamical range and linearity. A large bandwidth preserves the characteristics of the signal and fast readout reduces dead time. Next generation of IACT should reach an order of magnitude in sensitivity in a wide energy band, ranging from 10 GeV to more than 100 TeV. This goal can be reached with an array of 50-100 telescopes of various sizes at various spacings. With about 2 000 channels per camera a significant effort must be done to lower the overall cost and improve the performances of the electronics. Mass production will be determinant for lowering the overall cost. A gain in cost and performances can be obtained by maximising the integration of the front-end electronics in an ASIC. The amplifiers, analogue memories, digitization and first level buffering can be embedded in the same component. The first stage of the first level trigger should be also considered in this integration. Integrated electronics leads to a more compact camera and an easier maintenance on site.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraints on Extragalactic Background Light from Cherenkov telescopes: status and perspectives for the next 5 years

Very high energy (VHE, E>30 GeV){gamma}-rays are absorbed via interaction with low-energy photons from the extragalactic background light (EBL) if the involved photon energies are above the threshold for electron-positron pair creation. The VHE {gamma}-ray absorption, which is energy dependent and increases strongly with redshift, distorts the VHE energy spectra observed from distant objects. The observed energy spectra of the AGNs carry therefore an imprint of the EBL. Recent detections of hard spectra of distant blazars (z = 0.11-0.54) by H.E.S.S. and MAGIC put strong constraints on the EBL density in the optical to near infrared waveband. It is, however, not yet possible to distinguish between an intrinsic softening of blazar spectra and a softening caused by the interaction with low energy EBL photons. In this paper, we give an overview of the EBL constraints, their limitations and perspectives for the joint efforts of the Fermi Gamma-Ray Space telescope and imaging atmospheric Cherenkov telescopes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of a New Light Boson by Cherenkov Telescopes?

Recent observations by Imaging Atmospheric Cherenkov Telescopes (IACTs) strongly suggest a transparency of the Universe to very-high-energy (VHE) photons larger than expected from current models of the Extragalactic Background Light. It has been shown that such transparency can be naturally explained by the DARMA scenario. Its basic ingredient is a very light Axion-Like Particle (ALP) predicted by many extensions of the Standard Model of elementary particles and allows for the occurrence of photon-ALP oscillations in cosmic magnetic fields. We discuss the implications of the DARMA scenario for the VHE gamma-ray spectra of blazars by contemplating all such blazars at once, which allows us to correlate the emitted {gamma}{sub em} and observed {gamma}{sub obs} spectral indexes. We show that the predicted observed spectral index {gamma}{sub obs}{sup DARMA} actually fits observations even starting from the same nominal value {gamma}{sub em}{approx_equal}2.4 for all VHE blazars. Moreover, {gamma}{sub obs}{sup DARMA} becomes independent of redshift for far-away sources. Our prediction can be tested with the satellite-borne Fermi/LAT detector as well as with the ground-based IACTs H.E.S.S., MAGIC, CANGAROO III, VERITAS and the Extensive Air Shower arrays ARGO-YBJ and MILAGRO. Our result also offers an important observational test for models of dark energy wherein quintessence is coupled to the photon through an effective dimension-five operator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cyclotron frequency multiplication in Cherenkov backward-wave oscillators

In relativistic Cherenkov backward-wave oscillators, the output radiation is usually formed by a forward wave, which arises due to reflection of the operating backward wave from the input end of the operating waveguide. In this paper, we propose to use the resonant cyclotron absorption of this forward wave as a way to produce the secondary, stimulated cyclotron radiation at a multiplied frequency and a high cyclotron harmonic. Along with the 'simple' cyclotron resonance, the high-frequency wave can be emitted also in the regime of a combined resonance caused by nonresonant cyclotron interaction of electrons with the backward low-frequency wave. Existence of combined resonances helps provide the frequency synchronization, as well as to improve the electron-wave interaction at the multiplied frequency.

43 PARTICLE ACCELERATORS↗

Characteristics of four-channel Cherenkov-type detector for measurements of runaway electrons in the ISTTOK tokamak

A diagnostics capable of characterizing the runaway and superthermal electrons has been developing on the ISTTOK tokamak. In previous paper, a use of single-channel Cherenkov-type detector with titanium filter for runaway electron studies in ISTTOK was reported. To measure fast electron populations with different energies, a prototype of a four-channel detector with molybdenum filters was designed. Test-stand studies of filters with different thicknesses (1, 3, 7, 10, 20, 50, and 100 {mu}m) have shown that they should allow the detection of electrons with energies higher than 69, 75, 87, 95, 120, 181, and 260 keV, respectively. First results of measurements with the four-channel detector revealed the possibility to measure reliably different fast electrons populations simultaneously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

About a Gadolinium-doped Water Cherenkov LAGUNA Detector

Water Cherenkov (wC) detectors are extremely powerful apparatuses for scientific research. Nevertheless they lack of neutron tagging capabilities, which translates, mainly, into an inability to identify the anti-matter nature of the reacting incoming anti-neutrino particles. A solution was proposed by R. Beacon and M. Vagins back in 2004: by dissolving in the water a compound with nucleus with very large cross section for neutron capture like the Gadolinium, with a corresponding emission of photons of enough energy to be detected, they can tag thermal neutrons with an efficiency larger than 80%. In this talk we detail the technique and its implications in the measurement capabilities and, as well, the new backgrounds induced. We discuss the improvement on their physics program, also for the case of LAGUNA type detectors. We comment shortly the status of the pioneering R and D program of the Super-Kamiokande Collaboration towards dissolving a Gadolinium compound in its water.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prospects and Challenges for a Large Water Cherenkov Detector for LBNE

The Long Baseline Neutrino Experiment (LBNE) is a proposed experiment that would send a beam of muon neutrinos from Fermilab to the DUSEL (Deep Underground Science and Engineering Laboratory) facility in South Dakota, a 1300 km baseline. One possible configuration for the far detector is one or more large water Cherenkov modules with a fiducial mass of at least 100 kilotons each. The prospects and challenges of such a detector, including the current design, will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Fabrication of Cherenkov Counters for the Detection of SNM

The need for large-size detectors for long-range active interrogation (AI) detection of SNM has generated interest in water-based detector technologies. Water Cherenkov Detectors (WCD) were selected for this research because of their transportability, scalability, and an inherent energy threshold. The detector design and analysis was completed using the Geant4 toolkit. It was demonstrated both computationally and experimentally that it is possible to use WCD to detect and characterize gamma rays. Absolute efficiency of the detector (with no energy cuts applied) was determined to be around 30% for a {sup 60}Co source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multimode terahertz-wave generation using coherent Cherenkov radiation

Multimode terahertz(THz)-wave generation using coherent Cherenkov radiation (CCR) was investigated. The frequency spectra of CCR, which utilized a metal-wrapped hollow dielectric tube of 7 mm outer radius and a picosecond electron bunch of 27 MeV beam energy, were measured by a Michelson interferometer with a 4.2 K silicon bolometer. In this study, discrete spectral components at frequencies of 0.09, 0.14, and 0.36 THz were observed experimentally and explained as transverse magnetic (TM) modes of TM{sub 03}, TM{sub 04}, and TM{sub 09}, respectively, according to a theoretical calculation for the tube.

43 PARTICLE ACCELERATORS↗

Cherenkov radiation of shear Alfven waves in plasmas with two ion species

A calculation is presented of the radiation pattern of shear Alfven waves generated by a burst of charged particles in a charge-neutral plasma with two-ions of differing charge-to-mass ratios. The wake pattern is obtained for the inertial and kinetic regimes of wave propagation. Due to the presence of two ion-species, the Alfven waves propagate within two different frequency bands separated by a gap. One band is restricted to frequencies below the cyclotron frequency of the heavier species and the other to frequencies between the ion-ion hybrid frequency and the cyclotron frequency of the lighter species. The radiation pattern in the lower frequency band is found to exhibit essentially the same properties reported in a previous study [Van Compernolle et al., Phys. Plasmas 15, 082101 (2008)] of a single species plasma. However, the upper frequency band differs from the lower one in that it always allows for the Cherenkov radiation condition to be met. The methodology is extended to examine the Alfvenic wake of point-charges in the inertial and adiabatic regimes. The adiabatic regime is illustrated for conditions applicable to fusion-born alpha particles in ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo validation experiments for the gas Cherenkov detectors at the National Ignition Facility and Omega

The gas Cherenkov detectors at NIF and Omega measure several ICF burn characteristics by detecting multi-MeV nuclear γ emissions from the implosion. Of primary interest are γ bang-time (GBT) and burn width defined as the time between initial laser-plasma interaction and peak in the fusion reaction history and the FWHM of the reaction history respectively. To accurately calculate such parameters the collaboration relies on Monte Carlo codes, such as GEANT4 and ACCEPT, for diagnostic properties that cannot be measured directly. This paper describes a series of experiments performed at the High Intensity γ Source (HIγS) facility at Duke University to validate the geometries and material data used in the Monte Carlo simulations. Results published here show that model-driven parameters such as intensity and temporal response can be used with less than 50% uncertainty for all diagnostics and facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗