Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cloud Clearing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

186 records · Page 11

Herbig Ae/Be Stars toward the Dark Cloud LDN 1667

We report the discovery of a new emission-line object, named SPH 4-South = (GAIA EDR3 5616553300192230272), toward the dark cloud LDN 1667. This object came to our attention after inspecting public images that show a faint diffuse nebula a few arcseconds south of SPH 4, an emission-line object previously classified as a T Tauri star. We present high-resolution spectra and analyzed JHK photometry of SPH 4 and SPH 4-South and new narrowband and archival broadband images of these objects. A comparison of the spectra of SPH 4 and SPH 4-South with high-resolution ones of DG Cir and R Mon strongly suggests that SPH 4 and SPH 4-South are Herbig Ae/Be stars. The classification of SPH 4-South is further supported by using a k-NN algorithm to its position in an H–K versus J–H color–color diagram. Both stars are detected in the four WISE bands and the WISE colors allow us to classify SPH 4 as a Class I and SPH 4-South as a Class II source. We also show that the faint nebula is most probably associated with SPH 4-South. Using published results on LDN 1667 and the Gaia Early Data Release 3, we conclude that SPH 4 is a member of LDN 1667. The case of SPH 4-South is not clear because the determination of its distance and proper motion could be affected by the nebulosity around the star, although membership of SPH 4-South to LDN 1667 cannot be ruled out.

47 OTHER INSTRUMENTATION↗

An Integrated View of Hydraulic Induced Fracture Geometry in Hydraulic Fracture Test Site 2

Until relatively recently, most of our understanding about the geometry of hydraulically induced fractures in unconventional reservoirs has been inferred by patterns observed via microseismic monitoring. Important information, such as fracture-azimuth, fracture-length, height-growth and other geometric data has been determined from microseismic “event clouds”, which in turn has been used to interpret a stimulated reservoir volume (SRV). It is important to note that relatively limited microseismic results have been acquired in conjunction with other diagnostics and validated in a consistent manner. The Hydraulic Fracture Test Site 2 (HFTS2) in the Permian Delaware Basin provides a unique opportunity to compare the frac geometry interpretations derived from multiple frac diagnostic tools and at multiple scales. The integrated view that emerges from all the frac diagnostic tools is that in HFTS2 the geometries of hydraulically induced fractures are not random and with a highly complex branching architecture. In fact, the fracs are mostly vertical, parallel plana domains, and both vertically and horizontally asymmetrical. The hydraulically induced fractures have a very consistent azimuth with a strike that matches SHmax. At the distance corresponding to the spacing between nearby wells in HFTS2, ~ 660 ft, the pattern of strain interceptions observed from Low Frequency Distributed Acoustic Sensing (LF-DAS) shows far-field dimensions that are consistent with the stage length dimensions at the stimulated well. In general, larger stages with higher number of clusters create larger number of interceptions and wider stimulated intervals than that of shorter stages with the same cluster to cluster spacing and fewer clusters. The hydraulically induced fractures also show a clear tendency to preferentially grow upwards as shown by the microseismic data, by the relative lower number of LF-DAS interceptions in nearby deeper wells and finally by the observed LF-DAS strain patterns in the vertical observation well. In the near field, the geometries of the fracture domains are also consistent. As shown by the distributed strain measurements obtained during production via the monitoring of Rayleigh Frequency Shift (RFS), each cluster has a separate, non-overlapping, frac-zone-domain that are generally centered around the locations of each perforation cluster. Overall, the hydraulically induced fractures in HFTS2 are interpreted as occurring in swarms associated with individual clusters, each with its own unique geometry but with similar predictable geometric and propagation tendencies. The comprehensive frac diagnostic program in HFTS2, the well-pad layout that permits the investigation of the Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/1-21URTC/D011S018R003/2477511/urtec-2021-5396-ms.pdf/1 by Carol Worster on 28 February 2022 URTeC 5396 2 impact that nearby producing wells has on frac geometry, together with an innovative Design of Experiment (DofE) that includes sequential-fracing, consistent cluster-to-cluster distances and few single-perforation cluster stages, has allowed us to gain a unique perspective about the geometry of the induced hydraulic fractures on this pad. Finally, the HFTS2 dataset has also provided us with a better understanding of the applicability and limitations of the different diagnostic tools.

58 GEOSCIENCES↗

Cold-Season Precipitation Sensitivity to Microphysical Parameterizations: Hydrologic Evaluations Leveraging Snow Lidar Datasets

Abstract Cloud microphysical processes are an important facet of atmospheric modeling, as they can control the initiation and rates of snowfall. Thus, parameterizations of these processes have important implications for modeling seasonal snow accumulation. We conduct experiments with the Weather Research and Forecasting (WRF V4.3.3) Model using three different microphysics parameterizations, including a sophisticated new scheme (ISHMAEL). Simulations are conducted for two cold seasons (2018 and 2019) centered on the Colorado Rockies’ ∼750-km 2 East River watershed. Precipitation efficiencies are quantified using a drying-ratio mass budget approach and point evaluations are performed against three NRCS SNOTEL stations. Precipitation and meteorological outputs from each are used to force a land surface model (Noah-MP) so that peak snow accumulation can be compared against airborne snow lidar products. We find that microphysical parameterization choice alone has a modest impact on total precipitation on the order of ±3% watershed-wide, and as high as 15% for certain regions, similar to other studies comparing the same parameterizations. Precipitation biases evaluated against SNOTEL are 15% ± 13%. WRF Noah-MP configurations produced snow water equivalents with good correlations with airborne lidar products at a 1-km spatial resolution: Pearson’s r values of 0.9, RMSEs between 8 and 17 cm, and percent biases of 3%–15%. Noah-MP with precipitation from the PRISM geostatistical precipitation product leads to a peak SWE underestimation of 32% in both years examined, and a weaker spatial correlation than the WRF configurations. We fall short of identifying a clearly superior microphysical parameterization but conclude that snow lidar is a valuable nontraditional indicator of model performance.

54 ENVIRONMENTAL SCIENCES↗

Quantifying the Solar Energy Resource for Puerto Rico

After Hurricane Maria, multiple U.S. Department of Energy laboratories studied the state of the electric grid in Puerto Rico and analyzed grid resilience and grid integration of renewable energy. As part of the work done at the National Renewable Energy Laboratory, researchers created new solar resource data, conducted a technical potential and supply curve analysis, and studied the interannual variability of the solar resource. A new methodology was developed to downscale solar resource data from the National Solar Radiation Data Base (NSRDB) from a 4-km x 4-km spatial and 30-minute temporal resolution to a 2 km x 2 km and 5-minute resolution. This methodology primarily used simple physical principles to develop high-resolution cloud properties which were then used to compute solar radiation. The high-resolution datasets were validated against ground measurements and the error metrics were found to be similar to the original lower resolution dataset. Using 20 years of downscaled data from the NSRDB multi-year capacity factors for photovoltaics (PV) were developed for both single-axis tracking and fixed latitude-tilt configurations. Use of the multi-year data provides the ability to understand variability in capacity factors due to variability in weather over a long period of time. For Puerto Rico the coastal regions were found to have significant higher capacity factors than inland. Using land-use and terrain information a technical potential analysis was conducted for Puerto Rico. This analysis restricted single PV plant development to a maximum of 100 MW nameplate capacity. The nameplate capacity for each municipality were then determined. Based on our assumptions, 56 of the 78 total municipalities of Puerto Rico contain some level of solar capacity. Most of the interior municipalities did not have any capacity because of the geographic exclusions used in this study. The lowest capacity for a PV plant observed in a municipality was 10 MW. The maximum capacity within a county was 2,000 MW. Further a supply curve analysis was conducted by taking the results of the technical potential and quantifying system and transmission costs. The levelized cost of energy (LCOE) was calculated for each theoretical PV plant site, and the levelized cost of transmission was added to the LCOE to produce a total cost estimate for each site. The results of the supply curve analysis allow for a relative comparison of the cost for integrating new PV capacity into the grid. This analysis indicates that cheaper total LCOE sites tend to be larger in capacity. The total capacity in this study was found to be far beyond the maximum peak load for the island. However, this study does not consider the economic and market potential for development. The cumulative capacity presented in this study assumes that the best locations are developed first and ignores the complex decision paths for new power plant development. Therefore, this analysis can only be treated as illustrative. Finally this study investigates the impact of inter-annual variability of resource using a variety of metrices including probability of exceedance and variation in capacity factor and LCOE. This study demonstrates that the capacity factor or LCOE could vary by over 10% year to year. This clearly indicates the risks involved in using any particular year of data and clearly points to the use of multi-year data to reduce some of the risks related to variability in weather.

14 SOLAR ENERGY↗

TRACER Carbonaceous Aerosols Thrust – University of California, Davis Field Campaign Report

The broader U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s TRacking Aerosol Convection interactions ExpeRiment (TRACER) campaign aims to increase our understanding of convective cloud life cycles and aerosol-convection interactions. Our TRACER Carbonaceous Aerosols Thrust-University of California, Davis (TRACER-CAT-UCDavis) study complemented these broader aims by characterizing and quantifying the optical properties and composition of carbonaceous aerosols during part of the TRACER intensive sampling period (July 1- July 31, 2022) at the first ARM Mobile Facility (AMF1) main site (M1) in La Porte, Texas. Our measurements complemented the suite of instrumentation already provided by the AMF1, expanding the capabilities through deployment of unique, state-of-the-science instrumentation. The instrumentation included: (i) two cavity-attenuated phase shift spectroscopy single-scatter albedo (CAPS-SSA) instruments operating at 530 nm and 630 nm, and that were modified to characterize particle light absorption, extinction, and scattering at elevated humidities; (ii) the UC Davis dual-wavelength cavity ringdown-photoacoustic spectrometer (CRD-PAS), which characterizes dry particle extinction and absorption at 405 nm and 532 nm; (iii) a soot particle aerosol mass spectrometer (SP-AMS) that operated in “laser only” mode that characterized the size-dependent compositions of black carbon (BC)-containing particles; (v) a thermal denuder, to remove coatings on particles; and (vi) a scanning electrical mobility sizer (SEMS), to characterize particle mobility diameters from 10-1300 nm. Our measurements occurred alongside complementary observations made by Los Alamos National Laboratory (LANL) during the TRACER-CAT-LANL study, including a humidified CAPS-SSA instrument operating at 450 nm. Our primary scientific interest is in understanding the relationship between particle composition and light absorption, with a particular focus on the influence of water uptake. While it is known that coatings on BC can enhance absorption, the extent to which this occurs in the atmosphere and the specific role that water plays as a coating remain unclear. The TRACER-CAT-UCDavis measurements were made with near-complete coverage for the CRD-PAS, SP-AMS, and SEMS throughout the intensive period. The UC Davis humidified CAPS-SSA instruments had significant challenges with operation owing to the demanding conditions (large temperature fluctuations, high humidity), exacerbated by supply chain issues that delayed resolution of these challenges. However, the humidified CAPS-SSA instrument operated by LANL operated throughout the intensive period with near-complete coverage. The dry light extinction measurements from the CRD-PAS measurements and the LANL CAPS-SSA exhibited a good correlation, although the CAPS-SSA systematically measured greater extinction values than expected. While all instruments, with the exception of an aerodynamic particle sizer (APS), measured behind a common particulate matter (PM)2.5 μm cyclone, the greater extinction measured by the LANL CAPS-SSA compared to the CRD-PAS may have resulted from different losses of larger particles in the sampling lines from the cyclone to the instruments; the tubing length was shorter from the cyclone to the LANL CAPS-SSA, consistent with this idea. A summary of the TRACER-CAT-UCDavis measurements, along with some of the TRACER-CAT-LANL measurements, are shown in the figure below. Notably, there were periods when the contributions of presumed dust were substantial and even dominated the observed light extinction and absorption. Also, there was a clear shift in the behavior of submicron particles from before July 16, 2022 to after, with the prior period exhibiting regular episodes of new particle formation and the latter period exhibiting rapid variations in the concentrations of small particles.

54 ENVIRONMENTAL SCIENCES↗

Enhancement of Optical Efficiency of CSP Mirrors for Reducing O&M Cost via Near-Continuous Operation of Self-Cleaning Electrodynamic Screens (EDS). Final Report

Over the past decade, techno-economical advancements in solar energy systems, particularly the improvement in the conversion efficiency of PV modules made with mono-crystalline silicon solar cells from 12% to 20%, as well as the cost reduction in manufacturing by a factor of about 10%, have made it possible to achieve a levelized cost of electricity (LCOE) in PV plants that is comparable to, or less than, the cost of deriving electricity from fossil fuels. Operating PV plants in mid-latitude sun-belt regions, where the solar irradiance level is highest, provides a high annual energy-yield (kWh/kWp) due to two factors: (1) the availability of predictable high solar irradiance throughout the year with the fewest interruptions in solar flux from clouds and rain, and (2) the increased conversion efficiency of crystalline solar cells, as recombination loss has decreased with increased intensity of the sunlight that illuminates the silicon solar cells. Semi-arid and desert regions, however, are plagued by high atmospheric dust concentrations and frequent sand storms. The deposition of a layer of dust on the optical surfaces of solar collectors such as PV modules and concentrating mirrors reduces the transmission efficiency of sunlight that actually reaches the solar cells or receivers, resulting in high energy-yield soiling loss. There are two major cost components to operating a solar plant: (1) installation costs, and (2) operation-and-maintenance (O&M) costs. There is no fuel cost; hence operating a solar plant in a semi-arid or desert region provides high returns on investment if soiling losses are mitigated via efficient cleaning methods and optimized cleaning frequency. If solar collectors are not cleaned, the accumulation of dust layers on solar collectors may cause the operation of such plants in arid regions to become economically unviable. Washing solar collectors with water and detergent, as is most commonly done now, is an efficient method for cleaning. The conventional approach in utility-scale solar plants is to use a large truck with a water tank and pump system for spraying deionized water on the surface of the solar collectors. Robotic cleaning with brushes, used for many solar plants, requires lesser water for cleaning. The water consumed using semi-automated cleaning of PV modules in utility-scale solar plants is approximately 2 liters/m 2 per cleaning cycle. The total optical surface area of the solar collectors in 1 TW-scale solar installation will be more than 3 × 109 m 2 ; hence an enormous amount of water be needed for cleaning. There simply is not enough fresh water in the sun-belt areas of the world for predicted cleaning needs. In solar power plants, the estimated cost of cleaning solar collectors includes expenses related to the equipment used, labor, cost of transportation of water, the energy required for cleaning, plus ancillary costs whereas the cost of water is not considered. The water used is obtained from sources located close to plant sites, unmindful of the environmental and societal impact as the power plants are oftentimes located in regions that face severe drought. This practice is very similar to the cost calculations in deriving the levelized cost of electricity (LCOE) in conventional power plants based on burning fossil fuel such as coal and gas, while disregarding the cost of climate change and health effects. Unless a water-free or low-water cleaning method is established, the expansion of solar plants may lose public support in areas suffering long intervals of drought. The goal of this research project has been the development and application of the Electrodynamic Screen (EDS) as a means for a water-free, scalable cleaning process applicable to solar-power installations, including rooftop applications. We describe here the development of an EDS film-based cleaning process as an emerging method for use on PV modules, parabolic troughs, and heliostats. This report aims to show the feasibility of integrating or retrofitting EDS films onto the optical surfaces of solar collectors (both PV and CSP) while maintaining high transmission or reflection efficiency. The cleaning action provided by the EDS film is an active method to remove dust deposits by electrodynamic force. Current lab-scale prototype EDS films, retrofitted onto solar panels and mirrors, have shown to be capable of maintaining optical transmission or specular-reflection efficiencies higher than 90% of initial values under clean conditions. The optical surfaces of solar collectors laminated with EDS films can remove more than 90% of deposited dust when the EDS is activated for less than two minutes. As an electrodynamic dust removal process, the EDS film-based method is designed primarily for the removal of dust in solar installations located in semi-arid and desert areas, where the atmosphere is often dry and dusty and rainfall is infrequent. While EDS film application minimizes water consumption and facilitates cleaning as frequently as needed, it has limitations in removing contaminants such as soot, organic pollutants deposited as fine films on the surface, and bird droppings. The dust removal efficiency of the EDS is maximum at relative humidity RH is 40 to 50% and decreases at when RH > 65%. Many solar plant sites undergo diurnal and seasonal cycles of high ambient, early afternoon temperatures and an RH that reaches the dew point early in the morning. These variations in atmospheric conditions do not limit the operation of the EDS film. This report presents a brief review of the progress and the potential of EDS film technology for mitigating the impact of dust on solar collectors via water-free cleaning, as well as current technical challenges regarding efficiency and durability. Our experimental data on the performance of EDS films show that: (1) the dust-removal efficiency (DRE) can reach levels higher than 90%, (2) the specular reflectivity (SR) of EDS film-laminated second-surface mirrors reach levels in excess of 90%, (3) the specular reflectivity restoration (SRR) can exceed 90%, (4) the output-power restoration (OPR) of PV modules can exceed 95%, and (5) the optical transmission efficiency (TE) of the EDS films can be greater than 90%. Working with Sandia National Laboratories (NM), Corning Research and Development Corporation (NY), Eastman Kodak (NY), Tomark-Worthen Industries (NH), and EDS Chile SPA (Chile), we have produced EDS film-laminated PV modules and demonstrated their self-cleaning functions without requiring water. We have demonstrated that the operational range of EDS films will cover the expected ambient temperature of solar fields at RH cycling varying from 20 to 95% as long as the EDS films are activated in the RH range 20 to 50%. (Typical solar-field climates in deserts and semi-arid lands often reach near dew point in coastal areas.) Our experiments on the application of hydrophobic-fluorinated nanoparticle coatings on EDS film surfaces show that the EDS operational range can be extended to higher RH levels that approach the dew point. At Eastman Kodak, as one of our industrial partners, we were able to establish a process for manufacturing EDS films using flexographic printing of the electrodes onto transparent polymer films. This process utilizes an existing manufacturing line at Eastman Kodak that allows fabrication of medium-scale EDS films (26 cm × 30 cm). The manufacturing process has the capacity to produce EDS films at high production speeds. The medium-scale EDS films that have been printed at Kodak were evaluated in the lab at Boston University. The EDS films produced at Kodak were laminated at Tomark-Worthen using an industrial scale vacuum laminator to produce EDS film stacks, which can be affixed onto the optical surfaces of PV modules or concentrating mirrors. The EDS film stack consists of the EDS films that have Willow® Glass (WG) which has a thickness of 100 μm as the front surface. The WG sheets obtained from Corning Research and Development Corporation are customized in size and shape to cover the active area of the EDS films. The back surface of the EDS film stack is integrated onto the optical surface of the solar panel or mirror using optically clear adhesive (OCA) films or silicone adhesives. The OCA films (thickness 25 μm) are produced by 3M. The EDS film stacks have the architecture: WG/OCA/EDS Film/OCA/ over PV module or solar mirror. The power-supply units needed for activating the electrodes of the EDS film were designed and produced at Boston University. These power supply units provide three-phase, 1.2 kV voltage pulses at a very low current (micro-ampere) level and at a low frequency (≈ 5 Hz). The voltage pulses are applied to the electrodes in a sequence such that the train of pulses resembles a unidirectional traveling wave of electrical field on the surface of the EDS film. The dust particles on the surface become charged electrostatically and are levitated by the Coulomb force. The lateral sweeping action of the traveling electric field created by the three-phase voltages pulses then sweeps the dust off the surface. The energy consumed by the EDS electrodes is less than 0.2 Wh/m 2 /cleaning cycle, enabling energy-efficient restoration of output power (OPR) of PV module or specular reflectivity restoration (SRR) for solar mirrors. The EDS system consists of (1) an EDS film stack laminated onto the solar collectors, (2) connection of the EDS film to its power supply unit and (3) Interconnection of the power supply to PV modules or solar mirrors. Design, construction and assessment of field-testing units that have EDS stack laminated PV modules for evaluating the performance of the EDS films in solar fields is being carried out at BU. Our progress under this project, aimed at the advancement of EDS film technology, has reached DOE Technology Readiness Level (TRL) 6. Based on the extensive laboratory evaluations and limited field trials, as well as contacts with potential users, we believe that the technology has reached its commercial stage. We are conducting a cost analysis using the National Renewable Energy Laboratory (NREL) System Advisory Model (SAM) and are preparing for field trials of EDS films in different solar fields in the US, Chile, India and in the Middle East. A brief description of EDS film performance, construction and testing of the field-test unit, autonomous operation of the field-test unit for evaluating EDS performance in increasing energy yield, associated revenue savings, and water conservation is presented.

14 SOLAR ENERGY↗