Search NASA⌕ Search

SEARCH · Search NASA

Results for “Compass”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Characterizing Bioavailable Soil Nutrients Across Coastal Systems: Western Lake Erie and Chesapeake Bay

Terrestrial Aquatic Interfaces (TAIs), defined as where land meets water, exhibit important hydrological, biological, and biogeochemical dynamics and play a critical role in the Earth’s carbon cycle. Current Earth System Models improperly represent this role due to the complexity of these systems and the disproportionally large impact TAIs have relative to their area. To improve our predictive capacity of coastal system dynamics, a better understanding of carbon and nutrient cycling across TAI’s is needed. Coastal Observations, Mechanisms, and Predictions Across Systems and Scales (COMPASS) aims to achieve this through field observations and laboratory incubations throughout the Western Lake Erie and Chesapeake Bay regions. Here, we report on preliminary results from a soil characterization experiment across the WLE and CB regions. This experiment was conducted as part of the 2-year field, measurements, and experiments (FME) pilot study portion of COMPASS to provide initial baseline data for the sites and to characterize the spatial variability of our analytes. Soil samples were collected from three locations along the TAI transect (upland forest, transitional forest, and wetland) and analyzed for bioavailable nutrients using three types of extractions: (a) water extractions, (b) 2M KCl extractions, and (c) 1M NH4Cl extractions to analyze (a) water soluble organic carbon (WSOC), (b) ammonium and nitrate, and (c) base cations, including Ca, Mg, Na, K, and Fe. These analyses, in conjunction with other bulk physicochemical analyses, will help establish baseline understanding of these sites to drive future research and design focused experiments that will ultimately improve our predictive understanding of these freshwater and marine coastal TAIs and their response to short and long-term changes.

54 ENVIRONMENTAL SCIENCES↗

Criteria for Determination of Material Control and Accountability System Effectiveness

The Nevada Test Site (NTS) is a test bed for implementation of the Safeguards First Principles Initiative (SFPI), a risk-based approach to Material Control & Accountability (MC&A) requirements. The Comprehensive Assessment of Safeguards Strategies (COMPASS) model is used to determine the effectiveness of MC&A systems under SFPI. Under this model, MC&A is divided into nine primary elements. Each element is divided into sub-elements. Then each sub-element is assigned two values, effectiveness and contribution, that are used to calculate the rating. Effectiveness is a measure of subelement implementation and how well it meets requirements. Contribution is a relative measure of the importance, and functions as a weighting factor. The COMPASS model provides the methodology for calculation of sub-element and element ratings, but not the actual criteria. Each site must develop its own criteria. For the rating to be meaningful, the effectiveness criteria must be objective and based on explicit, measurable criteria. Contribution (weights) must reflect the importance within the MC&A program. This paper details the NTS approach to system effectiveness and contribution values, and will cover the following: the basis for the ratings, an explanation of the contribution “weights,” and the objective, performance based effectiveness criteria. Finally, the evaluation process will be described.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design and Optimization of Large Accelerator Systems through High-Fidelity Electromagnetic Simulations

SciDAC1, with its support for the 'Advanced Computing for 21st Century Accelerator Science and Technology' (AST) project, witnessed dramatic advances in electromagnetic (EM) simulations for the design and optimization of important accelerators across the Office of Science. In SciDAC2, EM simulations continue to play an important role in the 'Community Petascale Project for Accelerator Science and Simulation' (ComPASS), through close collaborations with SciDAC CETs/Institutes in computational science. Existing codes will be improved and new multi-physics tools will be developed to model large accelerator systems with unprecedented realism and high accuracy using computing resources at petascale. These tools aim at targeting the most challenging problems facing the ComPASS project. Supported by advances in computational science research, they have been successfully applied to the International Linear Collider (ILC) and the Large Hadron Collider (LHC) in High Energy Physics (HEP), the JLab 12-GeV Upgrade in Nuclear Physics (NP), as well as the Spallation Neutron Source (SNS) and the Linac Coherent Light Source (LCLS) in Basic Energy Sciences (BES).

43 PARTICLE ACCELERATORS↗

Recent developments in nucleon spin structure with focus on h_{1L}^{\perp} and pretzelosity h_{1T}^\perp

The leading twist transverse momentum dependent parton distribution functions h_{1L}^{\perp} and h_{1T}^\perp, which is sometimes called "pretzelosity," are studied. For h_{1L}^{\perp} we consider a "Wandzura-Wilczek-type" approximation, which follows from QCD equations of motion upon the neglect of pure twist-3 terms and allows to express it in terms of transversity. On the basis of available data from HERMES we test the practical usefulness of this approximation and discuss how it can be further tested by future CLAS and COMPASS data. We review the theoretical properties of retzelosity and observe an interesting relation valid in a large class of relativistic models: The difference between helicity and transversity distributions, which is often said to be a 'measure of relativistic effects' in the nucleon, is nothing but the transverse moment of pretzelosity. We discuss preliminary deuteron target data from COMPASS on the single spin asymmetry (SSA) in semi-incl

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deconvolution-based correction of alkali beam emission spectroscopy density profile measurements

A deconvolution-based correction method of the beam emission spectroscopy (BES) density profile measurement is demonstrated by its application to simulated measurements of the COMPASS and TEXTOR tokamaks. If the line of sight is far from tangential to the flux surfaces, and the beam width is comparable to the scale length on which the light profile varies, the observation may cause an undesired smoothing of the light profile, resulting in a non-negligible underestimation of the calculated density profile. This effect can be reduced significantly by the emission reconstruction method, which gives an estimate of the emissivity along the beam axis from the measured light profile, taking the finite beam width and the properties of the measurement into account in terms of the transfer function of the observation. Characteristics and magnitude of the mentioned systematic error and its reduction by the introduced method are studied by means of the comprehensive alkali BES simulation code RENATE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma tomographic reconstruction from tangentially viewing camera with background subtraction

Light reflections are one of the main and often underestimated issues of plasma emissivity reconstruction in visible light spectral range. Metallic and other specular components of tokamak generate systematic errors in the optical measurements that could lead to wrong interpretation of data. Our analysis is performed at data from the tokamak COMPASS. It is a D-shaped tokamak with specular metallic vessel and possibility of the H-mode plasma. Data from fast visible light camera were used for tomographic reconstruction with background reflections subtraction to study plasma boundary. In this article, we show that despite highly specular tokamak wall, it is possible to obtain a realistic reconstruction. The developed algorithm shows robust results despite of systematic errors in the optical measurements and calibration. The motivation is to obtain an independent estimate of the plasma boundary shape.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The reaction π{sup −}p → π{sup −}π{sup −}π{sup +}p: Development of the analysis methods and selected results

We present the description of the analysis methods and results of applying them to the exclusive diffractive reaction π{sup −}p → π{sup −}π{sup −}π{sup +}p of 50 · 10{sup 6} events measured with COMPASS detector. The large statistics of π{sup −}π{sup −}π{sup +} events enables the two-dimensional partial-wave analysis independently in 100 bins of m(3π) with 0.5 < m(3π) < 2.5 GeV/c{sup 2} and in 11 intervals of squared momentum transfer with 0.1 < t′ < 1 GeV{sup 2}/c{sup 2}. The partial-wave analysis sub-density matrix is the subject to further mass-dependent fits describing the data in terms of resonances in 3π system and coherent background contributions. The novel approach of extracting J{sup PC} = 0{sup ++}(π{sup +}π{sup −}){sub S} isobar amplitudes as model-free functions, different for several J{sup PC} 3π states, is used. It demonstrates the presence of processes π(1800) → f{sub 0}(980)π and π(1800) → f{sub 0}(1500)π as well as π{sub 2}(1880) → f{sub 0}(980)π and new narrow signal a{sub 1}(1420) → f{sub 0}(980)π, without any established shapes used for (π{sup +}π{sup −}){sub S} isobars. The presented analysis is subject to further development and refinements which currently take place.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gluon polarization in the proton

We combine heavy-quark renormalization group arguments with our understanding of the nucleon's wave function to deduce a bound on the gluon polarization {Delta}g in the proton. The bound is consistent with the values extracted from spin experiments at COMPASS and RHIC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phenomenological analysis of the nucleon spin contents and their scale dependence

In the past few years, a great deal of evidence has accumulated which indicates that the gluon polarization inside the nucleon is likely to be small at least at the low renormalization scales. On the other hand, the recent lattice QCD analyses suggest that the net orbital angular momentum carried by the quarks is nearly zero. There is also some indication, noted by Brodsky and Gardner based on the COMPASS observation of small single-spin asymmetry on the isoscalar deuteron target, that the gluon orbital angular momentum inside the nucleon is likely to be small. Naively combining all these observations, we are led to a rather embarrassing conclusion that the nucleon constituents altogether do not carry an adequate amount of angular momentum saturating the total nucleon spin. We show that this somewhat confused state of affairs can be cleared up only by paying careful attention to the scale dependencies of the nucleon spin decomposition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

h{sub 1T}{sup perpendicular} and quark orbital angular momentum

We calculate the pretzelosity distribution (h{sub 1T}{sup perpendicular}), which is one of the eight leading twist transverse momentum dependent parton distributions (TMDs), in the light-cone formalism. We find that this quantity has a simple relation with the quark orbital angular momentum distribution, thus it may provide a new possibility to access the quark orbital angular momentum inside the nucleon. The pretzelosity distribution can manifest itself through the sin(3{phi}{sub h}-{phi}{sub S}) asymmetry in semi-inclusive deep inelastic scattering process. We calculate the sin(3{phi}{sub h}-{phi}{sub S}) asymmetry at HERMES, COMPASS, and JLab kinematics and present our prediction on different targets including the proton, deuteron, and neutron targets. Inclusion of transverse momentum cut in data analysis could significantly enhance the sin(3{phi}{sub h}-{phi}{sub S}) asymmetry for future measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sivers effect in Drell-Yan processes

The Sivers distributions recently extracted from semi-inclusive deep inelastic scattering data [M. Anselmino et al., Eur. Phys. J. A 39, 89 (2009)] are used to compute estimates for Sivers asymmetries in Drell-Yan processes which are being planned at several facilities (RHIC, COMPASS, J-PARC, PAX, PANDA, NICA (JINR) and SPASCHARM (IHEP)). Most of these asymmetries turn out to be large and could allow a clear test of the predicted sign change of the Sivers distributions when active in SIDIS and Drell-Yan processes. This is regarded as a fundamental test of our understanding, within QCD and the factorization scheme, of single spin asymmetries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Azimuthal spin asymmetries in light-cone constituent quark models

We present results for all leading-twist azimuthal spin asymmetries in semi-inclusive lepton-nucleon deep-inelastic scattering due to T-even transverse-momentum dependent parton distribution functions on the basis of a light-cone constituent quark model. Attention is paid to discuss the range of applicability of the model, especially with regard to the scale dependence of the observables and the transverse-momentum dependence of the distributions. We find good agreement with available experimental data and present predictions to be further tested by future CLAS, COMPASS, and HERMES data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Longitudinal polarization of hyperon and antihyperon in semi-inclusive deep-inelastic scattering

We make a detailed study of the longitudinal polarization of hyperons and antihyperons in semi-inclusive deep-inelastic lepton-nucleon scattering. We present the numerical results for spin transfer in quark fragmentation processes, and analyze the possible origins for a difference between the polarization for hyperon and that for the corresponding antihyperon. We present the results obtained in the case that there is no asymmetry between sea and antisea distribution in the nucleon as well as those obtained when such an asymmetry is taken into account. We compare the results with the available data such as those from COMPASS and make predictions for future experiments including those at even higher energies such as at eRHIC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pion polarizability in the Nambu-Jona-Lasinio model and possibilities of its experimental studies in Coulomb nuclear scattering

The charge pion polarizability is calculated in the Nambu-Jona-Lasinio model, where the quark loops (in the mean field approximation) and the meson loops (in the 1/N{sub c} approximation) are taken into account. We show that quark loop contribution dominates because the meson loops strongly conceal each other. The sigma-pole contribution (m{sub {sigma}}{sup 2}-t){sup -1} plays the main role and contains strong t-dependence of the effective pion polarizability at the region |t|{>=}4M{sub {pi}}{sup 2}. Possibilities of experimental test of this sigma-pole effect in the reaction of Coulomb nuclear scattering are estimated for the COMPASS experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic moments of octet baryons, angular momenta of quarks, and sea antiquark polarizations

One can determine antiquark polarizations in a proton using the information from deep inelastic scattering, {beta} decays of baryons, orbital angular momenta of quarks, as well as their integrated magnetic distributions. The last quantities were determined previously by us performing a fit to magnetic moments of a baryon octet. However, because of the SU(3) symmetry our results depend on two parameters. The quantity {Gamma}{sub V}, measured recently in a COMPASS experiment, gives the relation between these parameters. We can fix the last unknown parameter using the ratio of up and down quark magnetic moments which one can get from the fit to radiative vector meson decays. We calculate antiquark polarizations with the orbital momenta of valence quarks that follow from lattice calculations. The value of the difference of up and down antiquark polarizations obtained in our calculations is consistent with the result obtained in a HERMES experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Study of a Mini-Drift GEM Tracking Detector

In this paper, a GEM tracking detector with an extended drift region has been studied as part of an effort to develop new tracking detectors for future experiments at RHIC and for the Electron Ion Collider that is being planned for BNL or JLAB. The detector consists of a triple GEM stack with a 1.6 cm drift region that was operated in a mini TPC type configuration. Both the position and arrival time of the charge deposited in the drift region were measured on the readout plane which allowed the reconstruction of a short vector for the track traversing the chamber. The resulting position and angle information from the vector could then be used to improve the position resolution of the detector for larger angle tracks, which deteriorates rapidly with increasing angle for conventional GEM tracking detectors using only charge centroid information. Two types of readout planes were studied. One was a COMPASS style readout plane with 400 μm pitch XY strips and the other consisted of 2 × 10 mm 2 chevron pads. The detector was studied in test beams at Fermilab and CERN, along with additional measurements in the lab, in order to determine its position and angular resolution for incident track angles up to 45 degrees. Several algorithms were studied for reconstructing the vector using the position and timing information in order to optimize the position and angular resolution of the detector for the different readout planes. Finally, applications for large angle tracking detectors at RHIC and EIC are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the spatial resolution of an online dose verification device

Purpose: The aim of this work is to characterize a new online dose verification device, COMPASS transmission detector array (IBA Dosimetry, Schwarzenbruck, Germany). The array is composed of 1600 cylindrical ionization chambers of 3.8 mm diameter, separated by 6.5 mm center-to-center spacing, in a 40 x 40 arrangement. Methods: The line spread function (LSF) of a single ion chamber in the detector was measured with a narrow slit collimator for a 6 MV photon beam. The 0.25 x 10 mm{sup 2} slit was formed by two machined lead blocks. The LSF was obtained by laterally translating the detector in 0.25 mm steps underneath the slit over a range of 24 mm and taking a measurement at each step. This measurement was validated with Monte Carlo simulation using BEAMnrc and DOSXYZnrc. The presampling modulation transfer function (MTF), the Fourier transform of the line spread function, was determined and compared to calculated (Monte Carlo and analytical) MTFs. Two head-and-neck intensity modulated radiation therapy (IMRT) fields were measured using the device and were used to validate the LSF measurement. These fields were simulated with the BEAMnrc Monte Carlo model, and the Monte Carlo generated incident fluence was convolved with the 2D detector response function (derived from the measured LSF) to obtain calculated dose. The measured and calculated dose distributions were then quantitatively compared using {chi}-comparison criteria of 3% dose difference and 3 mm distance-to-agreement for in-field points (defined as those above the 10% maximum dose threshold). Results: The full width at half-maximum (FWHM) of the measured detector response for a single chamber is 4.3 mm, which is comparable to the chamber diameter of 3.8 mm. The pre-sampling MTF was calculated, and the resolution of one chamber was estimated as 0.25 lp/mm from the first zero crossing. For both examined IMRT fields, the {chi}-comparison between measured and calculated data show good agreement with 95.1% and 96.3% of in-field points below {chi} of 1.0 for fields 1 and 2, respectively (with an average {chi} of 0.29 for IMRT field 1 and 0.24 for IMRT field 2). Conclusions: The LSF for a new novel online detector has been measured at 6 MV using a narrow slit technique, and this measurement has been validated by Monte Carlo simulation. The detector response function derived from line spread function has been applied to recover measured IMRT fields. The results have shown that the device measures IMRT fields accurately within acceptable tolerance.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-152: Error Sensitivity and Superiority of a Protocol for 3D IMRT Quality Assurance

Purpose: To test if the parameters included in our 3D QA protocol with current tolerance levels are able to detect certain errors and show the superiority of 3D QA method over single ion chamber measurements and 2D gamma test by detecting most of the introduced errors. The 3D QA protocol parameters are: TPS and measured average dose difference, 3D gamma test with 3mmDTA/3% test parameters, and structure volume for which the TPS predicted and measured absolute dose difference is greater than 6%. Methods: Two prostate and two thoracic step-and-shoot IMRT patients were investigated. The following errors were introduced to each original treatment plan: energy switched from 6MV to 10MV, linac jaws retracted to 15cmx15cm, 1,2,3 central MLC leaf pairs retracted behind the jaws, single central MLC leaf put in or out of the treatment field, Monitor Units (MU) increased and decreased by 1 and 3%, collimator off by 5 and 15 degrees, detector shifted by 5mm to the left and right, gantry treatment angle off by 5 and 15 degrees. QA was performed on each plan using single ion chamber, 2D ion chamber array for 2D gamma analysis and using IBA's COMPASS system for 3D QA. Results: Out of the three tested QA methods single ion chamber performs the worst not detecting subtle errors. 3D QA proves to be the superior out of the three methods detecting all of introduced errors, except 10MV and 1% MU change, and MLC rotated (those errors were not detected by any QA methods tested). Conclusion: As the way radiation is delivered evolves, so must the QA. We believe a diverse set of 3D statistical parameters applied both to OAR and target plan structures provides the highest level of QA.

07 ISOTOPE AND RADIATION SOURCES↗