Search NASA⌕ Search

SEARCH · Search NASA

Results for “Concentration of measure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Femtosecond ultraviolet laser absorption spectroscopy for simultaneous measurements of temperature and OH concentration

This Letter reports a femtosecond ultraviolet laser absorption spectroscopy (fs-UV-LAS) for simultaneous in situ measurements of temperature and species. Here, this fs-UV-LAS technique was demonstrated based on X 2 Π-A 2 Σ + transitions of OH radicals near 308 nm generated in low temperature plasmas and flames. The fs-UV-LAS technique has revealed three major diagnostic benefits. First, a series of absorption features within a spectral bandwidth of ~3.2 nm near 308 nm were simultaneously measured and then enabled simultaneous multi-parameter measurements with enhanced accuracy. The results show that the temperature and OH concentration could be measured with accuracy enhanced by 29–88% and 58–91%, respectively, compared to those obtained with past two-narrow-line absorption methods. Second, an ultrafast time resolution of ~120 picoseconds was accomplished for the measurements. Third, due to the large OH X 2 Π-A 2 Σ + transitions in the UV range, a simple single-pass absorption with a 3-cm path length was allowed for measurements in plasmas with low OH number density down to ~2 × 10 13 cm –3 . Also due to the large OH UV transitions, single-shot fs absorption measurements were accomplished in flames, which was expected to offer more insights into chemically reactive flow dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparing Experimentally-Measured Sand’s Times with Concentrated Solution Theory Predictions in a Polymer Electrolyte

We compare the electrochemically measured Sand’s time, the time required for the cell potential to diverge when the applied current density exceeds the limiting current, with theoretical predictions for a 0.47 M poly(ethylene oxide) (5 kg mol −1 )/LiTFSI electrolyte. The theoretical predictions are made using concentrated solution theory which accounts for both concentration polarization and polymer motion, using independently measured parameters that depend on concentration, c : conductivity ( κ ), salt diffusion coefficient ( D ), cationic transference number with respect to the solvent velocity ( t + 0 ), thermodynamic factor 1 + dln f ± dln c , and partial molar volume of the salt ( V ̅ ); f ± is the mean molar activity coefficient of the salt. We find quantitative agreement between experimental data and theoretical predictions. We derive a generalized analytical expression for Sand’s time for electrolytes based on dilute solution theory. This expression correctly predicts the divergence of the Sand’s time at the limiting current, in agreement with experimental data and concentrated solution theory predictions. When the applied current is large compared to the limiting current, the analytical expression approaches the standard expression for Sand’s time used in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration and field deployment of low-cost sensor network to monitor underground pipeline leakage

Recent technological advances in methane detection have improved leak detection and repair. However, current methods to reliably measure methane concentrations rely on expensive instruments or demand significant labor input. There is interest in using affordable methane sensors that are responsive to ppmv level changes in methane concentrations in both urban and rural environments for monitoring underground natural gas pipeline leaks. This is especially relevant for situations where potentially significant leaks cannot be repaired immediately or smaller leaks that require long-term monitoring and further evaluation. In this work, a low-cost sensor unit, equipped with a metal oxide sensor, was designed, built, and calibrated over a wide range of methane concentrations and environmental conditions in preparation for field application. A network of these sensors was then installed at the test site and used to measure methane concentrations at ground level above known sub-surface natural gas emissions which emulated underground gas pipeline leaks. This low-cost sensor network measured over 4 days total for the two different known leakage rates. Results demonstrate that the sensors can continuously measure relative methane variability for extended periods but require calibration for a wide range of temperature and humidity conditions to properly determine absolute gas (i.e., methane) concentrations. Furthermore, when a regression analysis was conducted to evaluate the effects of meteorological parameters on methane concentration, air temperature and wind speed have strong impacts on the concentration. Overall, the network approach allows improved identification of leak location and monitoring of underground natural gas leaks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of gas-concentration-driven permeation for the examination of permeability, solubility, and diffusivity in varying materials

This manuscript describes the development and operation of an apparatus for the measurement of steady-state and transient gas permeation through different types of solid materials with varying geometries. It is capable of operation from 293 K to 673 K and could theoretically be used with any non-corrosive gas or a mix of gases, although only hydrogen isotopes are used in the current study. A quadrupole mass spectrometer is used to measure permeation fluxes as low as 1011 molecules/s. This unique test setup allows for the simultaneous measurement of diffusivity, solubility, and permeability. Furthermore, varying the pressure in the fore-sample volume allows for tests of Sievert’s law and can give information on surface effects.

Young, Katherine T. (ORCID:0000000285845576)↗

Systems, methods and tools for subterranean electrochemical characterization and enthalpy measurement in geothermal reservoirs

The present disclosure is directed to systems, methods and tools that measure ionic concentrations and downhole enthalpy of a flowing geothermal fluid in real-time at high-temperature and pressure. The systems, methods and tools include measuring the concentration of selected naturally occurring ions found in the liquid phase of the geothermal fluid throughout the wellbore using novel electrochemical sensor technologies. The change in liquid-phase ion concentration will be used to calculate the proportion of liquid to steam and allow for accurate enthalpy measurements. The techniques and technologies described here can be applied to any application of electrochemical sensing in extreme environments.

Cieslewski, Grzegorz↗

Results for the September Bimonthly Calendar Year 2022 Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the 2022 September bimonthly sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Mission Completion (SRMC) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) LIMITS and TARGETS that were established at the time the Tank 50 sample was obtained. The chemical and radionuclide contaminant results from the characterization of the 2022 September bimonthly sampling of Tank 50 were requested by SRMC personnel via a Task Technical Request (TTR). Details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is the TTR deliverable relating Salt Solution Analysis from the SRMC request. The following facts pertaining to the WAC are drawn from the analytical results, including analytical uncertainty, provided in this report. 1) WAC LIMITS and TARGETS were met for all analyzed chemical and radioactive contaminants for which the detection limits are below the WAC LIMITS and TARGETS; 2) Measured average concentrations of nitrate, nitrite and total mercury are approximately 24%, 9% and 12% of the WAC LIMITS, respectively; 3) Measured average concentrations of Tc-99 and I-129 are approximately 19% and 20% of the WAC LIMITS, respectively; 4) All other radionuclide average concentrations are at 4% or less of the WAC LIMITS and TARGETS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Four Ground-based Retrievals of Cloud Droplet Number Concentration in Marine Stratocumulus with Aircraft In Situ Measurements

Cloud droplet number concentration (N d ) is crucial for understanding aerosol-cloud interactions (ACI) and associated radiative effects. We present evaluations of four ground-based N d retrievals based on comprehensive datasets from the Atmospheric Radiation Measurements (ARM) Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) field campaign. The N d retrieval methods use ARM ENA observatory ground-based remote sensing observations from a Micropulse lidar, Raman lidar, cloud radar, and the ARM NDROP Value-added Product (VAP), all of which also retrieve cloud effective radius (r e ). The retrievals are compared against aircraft measurements from the Fast-Cloud Droplet Probe (FCDP) and the Cloud and Aerosol Spectrometer (CAS) obtained from low-level marine boundary layer clouds on 12 flight days during summer and winter seasons. Additionally, the in situ measurements are used to validate the assumptions and characterizations used in the retrieval algorithms. Statistical comparisons of the probability distribution function (PDF) of the N d and cloud r e retrievals with aircraft measurements demonstrate that these retrievals align well with in situ measurements for overcast clouds, but they may substantially differ for broken clouds or clouds with low liquid water path (LWP). The retrievals are applied to four years of ground-based remote sensing measurements of overcast marine boundary layer clouds at the ARM ENA observatory to find that N d (r e ) values exhibit seasonal variations, with higher (lower) values during the summer season and lower (higher) values during the winter season. The ensemble of various retrievals using different measurements and retrieval algorithms such as those in this paper can help to quantify N d retrieval uncertainties and identify reliable N d retrieval scenarios. Of the retrieval methods, we recommend using the using the Micropulse lidar-based method given its good agreement with in situ measurements, it has less sensitivity to issues arising from precipitation and low cloud LWP/optical depth, and it has broad applicability by functioning for both day and nighttime conditions.

54 ENVIRONMENTAL SCIENCES↗

Apparatuses and methods for anomalous gas concentration detection

Embodiments of the disclosure are drawn to apparatuses and methods for anomalous gas concentration detection. A spectroscopic system, such as a wavelength modulated spectroscopy (WMS) system may measure gas concentrations in a target area. However, noise, such as speckle noise, may interfere with measuring relatively low concentrations of gas, and may lead to false positives. A noise model, which includes a contribution from a speckle noise model, may be used to process data from the spectroscopic system. An adaptive threshold may be applied based on an expected amount of noise. A speckle filter may remove measurements which are outliers based on a measurement of their noise. Plume detection may be used to determine a presence of gas plumes. Each of these processing steps may be associated with a confidence, which may be used to determine an overall confidence in the processed measurements/gas plumes.

Kreitinger, Aaron Thomas↗

Measurement of Argon-37 Background Concentrations in the Atmosphere

Radioisotopes of noble gases, primarily xenon and argon, are important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133 Xe, 135 Xe, 131 mXe and 133 mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37 Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010). Therefore, inclusion of 37 Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations could improve the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37 Ar to evaluate the range of background concentrations. The range of 37 Ar concentrations measured in atmospheric air samples was relatively narrow ranging between less than 1 mBq/m 3 to greater than 2 mBq/m 3 . The average atmospheric concentration of all samples was 0.98 mBq/m 3 , with a standard deviation of 0.5 mBq/m 3 . This is consistent with previous published results. The results presented here demonstrate the capability to detect background concentrations of 37 Ar in atmospheric air.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cation Data for the East River Watershed, Colorado (2014-2025)

This data package contains mean values for cation concentration for water samples taken from the East River Watershed in Colorado. Inductively coupled plasma mass spectrometry (ICP-MS) has been used to measure the concentrations of elements of interest simultaneously for the East River Watershed, Colorado groundwater and surface water samples to inform insights on the biogeochemistry processes within the watershed. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. For samples collected prior to 06-16-2021, the instrumentation, Elan DRC II, PerkinElmer SCIEX, automatically switches among the three models necessary to analyze all 37 elements. These 37 elements include: (1) Lithium (Li), Beryllium (Be), Boron (B), Sodium (Na), Magnesium (Mg), Aluminium (Al), Silicon (Si), Phosphorus (P), Titanium (Ti), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Caesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th), Uranium (U) using standard model, argon Ar as reaction gas, (2) Potassium (K), Calcium (Ca), Vanadium (V), Chromium (Cr), Manganese (Mn), Iron (Fe) using dynamic reaction cell (DRC) model, ammonia NH3 as reaction gas, and (3) Phosphorus (P) and Selenium (Se) using DRC model, oxygen O2 as reaction gas. Note for the samples with higher concentrations of chloride (Cl-), asenic (As) concentrations were analysed with DRC model (oxygen O2 as reaction gas) to avoid the interference of chloride. For samples collected on and after 06-16-2021, an advanced Agilent 8900 triple quadrupole inductively coupled plasma mass spectrometry system (Agilent 8900 QQQ ICP-MS, Agilent Technologies) has been used to measure the concentrations of interested 36 elements simultaneously for environmental samples, including (1) Lithium (Li), Beryllium (Be) and Boron (B) using standard no gas mode, (2) Sodium (Na), Magnesium (Mg), Aluminium (Al) Phosphorus (P), Potassium (K), Chromium (Cr), Manganese (Mn), Iron (Fe), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Cesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th) and Uranium (U) using standard helium (He) collision mode, (3) Titanium (Ti) and Vanadium (V) using high Energy (HEHe) helium (He) collision mode, and (4) Silicon (Si), Calcium (Ca) and Selenium (Se) using standard H2 reaction mode. All samples were prepared/diluted with 2% (v/v) ultrapure nitric acid in Milli-Q water (18.2 mega ohm-cm), and analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (cation_data_2014_2025.zip) containing a total of 5,849 files: 5.848 data files of cation data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the detemination of Method Detection Limits (MDLs) for ICP-MS PerkinElmer DRC II instrumentation (Detemination_of_Method_Detection_Limits__MDLs__for_ICP_MS__PerkinElmer_Elan_DRC_II__LBL_Bldg74_Lab214D) for samples before November 2021; (5) PDF and docx files for the determination of MDLs for ICP-MS Agilent 8900 QQQ instrumentation (ICP_MS_Analysis_detection_limits_and_QA_QC_WenmingDong_updated_2026-08-06) for samples November 2021 and onward. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing cation data. Update on 2021-04-11: Added Detemination of Method Detection Limits (MDLs) for ICP-MS document, which can be accessed as a PDF or with Microsoft Word. Update on 2022-06-10: versioned updates to this dataset was made along with these changes: (1) updated cation data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) removed suffix and prefix on two variables (“aqberylliumion_asberyllium” and “aqlithiumion_aslithium”), (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-16. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Updated versions of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-06, of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of methods for characterizing the fine particulate matter emissions from aircraft and other diffusion flame combustion aerosol sources

The U. S. Environmental Protection Agency in collaboration with the U. S. Air Force Arnold Engineering Development Complex conducted the VAriable Response In Aircraft nvPM Testing (VARIAnT) 3 and 4 test campaigns to compare nvPM emissions measurements from a variety of diffusion flame combustion aerosol sources (DFCASs), including a Cummins diesel engine, a diesel powered generator, two gas turbine start carts, a J85-GE-5 turbojet engine burning multiple fuels, and a Mini-CAST soot generator. The VARIAnT research program has conducted four test campaigns to date with the VARIAnT 3 and 4 test campaigns focusing on BC mass instrument performance, use of gas turbine engine sources for BC mass instrument calibration, and the characterization of the aerosols produced from the combustion sources. Results from both campaigns revealed agreement of about 20% between the AVL Micro-Soot Sensor, the Cavity Attenuated Phase Shift (CAPS PMSSA) monitor and the thermal-optical reference method for elemental carbon (EC), independent of the calibration source used. For the Artium LII-300, the measured mass concentrations in VARIAnT3 fall within 18% and in VARIAnT4 fall within 32% of the reference EC mass concentration when calibrated on a combustor rig in VARIAnT3 and on a LGT-60 start cart in VARIAnT4, respectively. It was also found that the three mass instrument types (MSS, CAPS PMSSA, and LII-300) can exhibit different BC to reference EC ratios depending on the emission source that appear to correlate to particle geometric mean mobility diameter, morphology, or some other parameter associated with particle geometric mean diameter (GMD) with the LII-300 showing a slightly stronger apparent trend with GMD. Systematic differences in LII-300 measured mass concentrations have been reduced by calibrating with a turbine combustion source (combustor or turbine engine). With respect to the particle size measurements made, the sizing instruments (TSI SMPS, TSI EEPS, and Cambustion DMS 500) were found to be in general agreement in terms of size distributions and concentrations with some exceptions. Teflon filter measurements of the total aerosol mass produced by the various DFCASs differed from the reference EC, BC, and integrated particle sized distribution measured aerosol masses. The Teflon filter measured mass was 30 to 40% greater than the reference EC and 50 to 60% greater than the BC mass for the J85 in both test campaigns. The measurements of particle size distributions and single particle analysis by miniSPLAT indicated the presence of large particles (>100 nm) having more compact morphologies, higher effective density, and a composition dominated by OC and ash. This increased large particle fraction is also associated with higher values of single scattering albedo measured by the CAPS PMSSA instrument and higher OC/EC measurements. These measurements indicate gas turbine engine emissions can be a more heterogeneous mix of particle types beyond the original E31 assumption that it is mainly composed of black carbon.

33 ADVANCED PROPULSION SYSTEMS↗

Tissue Distribution of Mercury in the Bodies of Wild American Alligators ( Alligator mississippiensis ) from a Coastal Marsh in Louisiana (USA)

Total mercury (THg) concentrations were measured in wild alligators inhabiting a coastal marsh in southern Louisiana, to determine the tissue distribution of THg among various body organs and tissue compartments. Concentrations of THg in claws and dermal tail scutes were compared to those in blood, brain, gonad, heart, kidney, liver, and skeletal muscle to determine if the former tissues, commonly available by non-lethal sampling, could be used as measures of body burdens in various internal organs. Mercury was found in all body organs and tissue compartments. However, overall, THg concentrations measured in alligators were below the FDA action level for fish consumption and were comparable to previous data reported from southwestern Louisiana. Here, our results suggest consumption of meat from alligators found in this region may be of little public health concern. However, the extended period of time between sampling (in this study) and the present-day highlight the need for continuous, additional, and more recent sampling to ensure consumer safety. Total mercury concentrations were highest in the kidney (3.18 ± 0.69 mg/kg dw) and liver (3.12 ± 0.76 mg/kg dw). THg levels in non-lethal samples (blood, claws, and dermal tail scutes) were positively correlated with all tissue THg concentrations (blood: R 2 = 0.513 – 0.988; claw: R 2 = 0.347 – 0.637, scutes: R 2 = 0.333 – 0.649). Because THg concentrations from blood, claws, and scutes were correlated with those of the internal organs, non-lethal sampling methods may be a viable method of estimating levels of THg in other body tissues.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Measurements of OH radical concentrations in uniform and non-uniform nanosecond-pulsed dielectric barrier discharge plasma

In this work we studied OH radical generation in nanosecond dielectric barrier discharge in humid He/air gas. The measurements were carried out by means of laser-induced fluorescence (LIF) method at the PPPL Low Temperature Plasma Research Facility, directed by Dr. Shurik Yatom. Application of LIF towards OH density measurements is a widely used approach in plasmas generated in humid gas, particularly when temporal evolution of OH density is of interest. Here we examined the OH densities generated in the discharge ignited by application of nanosecond high-voltage pulses with amplitudes varying between 10 to 20 kV and interelectrode gap length varying between 0.5-3 mm. The peak voltage and the gap length determine the mode in which discharge is generated: homogenous or filamentary. The measurements of OH in the gas phase were accompanied by the measurements of hydrogen peroxide (H 2 O 2 ) in liquid water, downstream of the plasma and the relationship between these two were examined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implications of Aerosol Physicochemical Properties Including Ice Nucleation at ARM Mega Sites for Improved Understanding of Microphysical Atmospheric Cloud Processes (Final Technical Report)

Continuous, long-term measurements of atmospheric ice-nucleating particles (INPs) that influence clouds and precipitation were conducted to investigate the abundance and variability of ground-level INPs across the world. Three field campaigns were organized by the DOE Atmospheric Radiation Measurement (ARM) program, including Examining INP from Southern Great Plains (ExINP-SGP, 2019), Examining INP from Eastern North Atlantic (ExINP-ENA, 2020 – 2021), and Examining INP from North Slope of Alaska (ExINP-NSA, 2021 – 2024). Additional small-scale supporting field experiments were performed in 2019 and 2021 to collect airborne particulate matter at SGP for complementary laboratory characterization of the particles’ physical and chemical properties [Aerosol-Ice Formation Closure Pilot Study (AEROICESTUDY), 2019; ExINP-SGP II, 2021]. In these studies, the PI’s team measured INP concentration with both real-time and laboratory measurements in a wide range of freezing temperatures ($T$ from 0 °C to about –30 °C). This project elucidated spatial variability and seasonality in the abundance of immersion mode active INPs across three ARM sites using a single instrument, a Portable Ice Nucleation Experiment (PINE) chamber version 03 (PINE-03 hereafter). Collocated aerosol and meteorological data were analyzed to assess the correlation between ambient INP abundance, air mass origin region, and meteorological variability. Our findings suggest very high freezing efficiency of INPs at the NSA site across the measured temperatures (ice nucleation active surface site density, $n_s(T)$, $\approx 2 \times 10^{8} - 10^{10}$ m -2 for from –16 to –31 °C), which is a factor of 10 – 1000 times greater efficiency as compared to that found in the previous mid-latitude INP measurements in autumn using the same instrument; surprisingly high INP abundance ($\ge 1 \text{ L}^{-1}$ at –25 °C) for the examined temperatures throughout the year that PINE-03 did not measure at other sites; and high INP concentration in spring, possibly related to arctic haze episodes.

58 GEOSCIENCES↗

SCILLA nitrogen oxide (NOx) airborne data

Nitrogen oxides mixing ratios in ppb are measured using a Teledyne API Model T200UP. The analyzer uses chemiluminescence to determine NO concentration. Alternating measurement of the concentrations of total NOx (NO + NO2) and just NO are made by directing the sample through a blue light converter that photolyzes NO2 to NO and bypassing it, respectively, with the NO2 concentration calculated as the difference between the two. Sampled air was pulled from above the Naval Postgraduate School’s (NPS) Twin Otter aircraft through a rear-facing, ¼” OD PFA Teflon tube. The sample stream was split between several other gas analyzers (CO, O3, and H2O) and an oxidation flow reactor. The NO, NO2, and NOx mixing ratios were recorded once per minute.

NOx concentration↗

Evaluating Precision of Measured Radionuclide Ambient Air Concentrations

According to AIRNET – Quality Assurance Project Plan for the Radiological Air Sampling Network, SOP-5140, Revision 2 (to become EPC-CP-PIP-5140): “The regulation 40 CFR Part 61.93 requires that the system be able to readily detect a dose of 1.0 mrem above background. Following statistical principles and assuming 95% confidence for such a measurement, we require that 95% of all measurements must fall within two standard deviations of the mean. This represents the minimum acceptable precision for decision making.” An independent assessment of the Rad-NESHAP program completed in early 2019 found that no documentation existed proving that the Airnet data meets the precision defined above. Therefore, to address this particular finding, Airnet concentration data was pulled from the Environmental Information Management (EIM), a cloud-based database maintained by Locus Technologies, for analysis.

54 ENVIRONMENTAL SCIENCES↗

Fully‐Printed Ion Sensor Arrays for Measuring Agricultural Nitrogen and Potassium Concentrations Using Nernstian and AI Models

Abstract The chemical composition of growing media is a key factor for plant growth, impacting agricultural yield and sustainability. However, there is a lack of affordable chemical sensors for ubiquitous nutrient ion monitoring in agricultural applications. This work investigates using fully printed ion‐sensor arrays to measure the concentrations of nitrate, ammonium, and potassium in mixed‐electrolyte media. Ion sensor arrays composed of nitrate, ammonium, and potassium ion‐selective electrodes and a printed silver‐silver chloride (Ag/AgCl) reference electrode are fabricated and characterized in aqueous solutions in a range of concentrations that encompass what is typical for agricultural growing media (0.01 m m –1 m ). The sensors are also tested in mixed‐electrolyte solutions of NaNO 3 , NH 4 Cl, and KCl of varying concentrations, and the recorded potentials are input into Nernstian and artificial neural network models to compare the prediction accuracy of the models against ground truth. The artificial neural network models demonstrated higher accuracy over the Nernstian model, and the model using only ion‐sensor inputs is 7.5% more accurate than the Nernstian model under the same conditions. By enabling more precise and efficient fertilizer application, these sensor arrays coupled to computational models can help increase crop yields, optimize resource use, and reduce environmental impact.

Goodrich, Payton [University of California Berkele↗

Computational Fluid Dynamics-Based Modeling of Methane Flows Around Oil and Gas Equipment

Recent studies estimate that emissions from oil and gas production facilities contribute between 20 and 50% of the total methane ( CH 4 ) emitted in the US; therefore, quantifying and reducing these emissions are crucial for achieving climate goals. Methane quantification depends on both measuring methane concentrations and converting them to emissions through a modeling framework. Currently, simple atmospheric dispersion models are primarily used to quantify emissions and concentrations, but these estimates are highly uncertain when quantifying emissions from complex aerodynamic sources, such as oil and gas facilities. This investigation used a CFD modeling approach, which can account for aerodynamic complexity but has hitherto not been used to model methane concentrations downwind of a methane release of a known rate, and compared it against in situ measurements. High-time-resolution (1 Hz) methane concentration and meteorological data were measured during experiments conducted at the METEC on 21 March and 11 July 2024. The METEC site configuration, measured wind data, and controlled emission rates were used as input for the CONVERGE CFD model to model downwind CH 4 concentration. The modeling was carried out between 20 and 70 m, from two different points of release in two separate controlled-release experiments, one from a separator and another from a wellhead. In these experiments, we found that the CFD model could predict the CH 4 concentrations downwind of the release to a good degree. The model was evaluated on multiple metrics to assess its performance in estimating methane concentrations at typical fence line distances (∼30 m). These results help us to understand external flows and the ability of CFD models to predict downwind concentrations in aerodynamically complex environments.

03 NATURAL GAS↗