Search NASA⌕ Search

SEARCH · Search NASA

Results for “Configurations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Custom-trained Machine-learning Interatomic Potentials: ZnCl2 Aqueous Solution

This dataset was generated using an iterative active-learning strategy implemented in the ArcaNN software package (https://github.com/arcann-chem/arcann_training) to train machine-learning interatomic potentials for aqueous ZnCl2 solutions. Each active-learning cycle consisted of three stages: training, exploration, and labeling. The initial training set combined configurations generated in this work from enhanced-sampling ab initio molecular dynamics simulations with configurations from a previously reported neural-network-potential study of aqueous ZnCl2. The enhanced-sampling ab initio molecular dynamics simulations involved Zn–Cl separation and the chloride coordination number around Zn²? as collective variables. These configurations served as the seed dataset. Subsequent active-learning cycles expanded the training set by identifying and labeling configurations that were poorly represented by the current models, thereby improving coverage of ion-association states and changes in local coordination and charge-state environments relevant to the solution free-energy landscape. For all selected configurations, single-point calculations of the total energies and atomic forces were performed within density functional theory using the CP2K Quickstep module. Reference calculations employed the revPBE-D3 and r2SCAN exchange-correlation functionals. Motivated by recent work on aqueous Zn²?, the main revPBE calculations omitted D3 dispersion contributions involving Zn²?, while retaining the D3 correction for water and chloride. For comparison, fully dispersion-corrected revPBE-D3 reference calculations were also performed, with D3 applied to all species, including Zn²?. Valence electrons were treated explicitly, while core electrons were represented using norm-conserving Goedecker–Teter–Hutter pseudopotentials. The wave functions were expanded using the mixed Gaussian-and-plane-wave scheme with TZV2P-MOLOPT basis sets for all elements and a 600 Ry auxiliary plane-wave cutoff for the electron density. Self-consistent-field convergence was accelerated using the orbital-transformation and Direct Inversion in the Iterative Subspace algorithms, with a convergence threshold of 10?6. All single-point calculations were performed in periodic orthorhombic cells. The CELL_REF keyword in CP2K was used to define a fixed reference cell with a box length of 25 Å. This treatment ensured a consistent reference for configurations extracted from NpT trajectories with fluctuating cell dimensions. The resulting DFT energies and atomic forces constitute the ground-truth labels used to train the MLIPs. The resulting MLIP was trained for aqueous ZnCl2 solutions spanning concentrations from 0 to 30 molal and a broad pH range, from strongly acidic to strongly basic conditions. Representative examples of configurations included in the MLIP training dataset are provided below. These include 1) Representative configurations from the dataset labeled at the revPBE-D3 level, with D3 dispersion interactions involving Zn2+ excluded (revPBE-wo-D3). 2) Representative configurations from the dataset labeled at the fully dispersion-corrected revPBE-D3 level, with D3 interactions applied to all species, including Zn2+ (revPBE-D3). 3) Representative configurations from the dataset labeled at the r2SCAN level of theory (r2SCAN).

Dinpajooh, Mohammadhasan [Pacific Northwest Nation↗

Minimizing the Electromechanical Stresses in Poloidal Field Coils by Optimizing their Numbers and Locations using FREDA Framework

Poloidal field (PF) and central solenoid (CS) coils play a crucial role in sustaining the equilibrium and preserving the shape of highly confined tokamak plasmas. Ensuring that PF coil current and mechanical stress stay within superconducting and structural limitations is an important check in the design assessment. Minimizing the PF coil currents and mechanical stresses influences reliability, cost, and performance. A free-boundary MHD equilibrium code—FreeGS is employed within the fusion reactor design and assessment (FREDA) whole facility modeling (WFM) framework to construct the plasma equilibrium based on the configuration and currents in the PF coils. Here, we present the capability of the FreeGS code to minimize the currents, forces, and electromagnetic stresses on the PF coils by optimizing their number, sizes, structures, and locations while maintaining an MHD stable plasma configuration with a large confinement factor. The workflow is initialized with a configuration of plasma parameters and coils’ locations from the 0-D tokamak build systems code in the FREDA framework. Then, FreeGS is called to calculate the initial equilibrium at the minimum total current in PF coils. Thereafter, FreeGS’s internal optimizer minimizes the currents and hoop and central forces on the PF coils while maintaining the reference equilibrium. Finally, the input configuration is updated with the optimized parameters for equilibria over the ramp-up phase of a burning-plasma operation. FREDA’s whole facility optimization capability, which includes all magnetic field coil systems, blanket, vacuum vessel (VV), first wall, divertor, etc., is under development and out of the scope for this study.

Hassan, Ehab [ORNL] (ORCID:0000000181060301)↗

IER 519 Experiment Execution Report: TEX Hanford

The TEX-Hanford experiments were performed at the National Criticality Experiments Research Center (NCERC) at the Device Assembly Facility (DAF) at the Nevada Nuclear Security Site (NNSS). Three configurations were measured, with the measurements occurring in December 2025 and January 2026. The Fe-14 configuration was executed in December 2025; the Fe-11 configuration began its handstack on the Planet critical assembly machine in December 2025, but was taken critical in January 2026; the Fe-16 configuration was executed entirely in January 2026. The TEX-Hanford experiments were performed on the Planet critical assembly machine utilizing using PANN (Plutonium Aluminum No Nickel) ZPPR (Zero Power Physics Reactor) plutonium plates as fuel. The configurations were moderated with varying thicknesses of HDPE and iron absorber. This document details the configurations that were measured, preliminary reactivity measurements of the measured configurations, data files from the neutron detection systems, and results from the coordinate-measuring machine (CMM) measurements of the final stack height measurements each configuration.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of Forest Canopy Structure on Buoyant Plume Dynamics During Wildland Fires

Heterogeneous forest canopies can generate complex turbulent structures, but in the presence of a fire plume, these interactions are not fully understood. This study investigates the influence of forest canopy heterogeneity on buoyant plume dynamics resulting from surface thermal anomalies representing wildland fires, utilizing Large Eddy Simulation (LES). The Parallelized Large-Eddy Simulation Model (PALM) was employed to simulate six canopy configurations: no canopy, homogeneous canopy, external plume-edge canopy, internal plume-edge canopy, 100 m gap canopy, and 200 m gap canopy. Each configuration was analyzed with and without a static surface heat flux patch of 5000 W ∙ m -2 , resulting in a resting buoyant plume. Simulations were conducted under three crosswind speeds: 0, 5, and 10 m ∙ s -1 . Results show that canopy structure significantly modifies plume behavior, mean flow, and turbulent kinetic energy (TKE) budgets. Plume updraft speed and tilt varied with canopy configuration and crosswind speed. Horizontal pressure gradients associated with plume-atmosphere interaction were modified based on the canopy configuration, resulting in varying crosswind speed reductions at the plume region. Strong momentum absorption was observed above the canopy for the crosswind cases, with the greatest enhancement in the gap canopies. Momentum injection from below the canopy due to the heat source was also observed, resulting in plume structure modulation based on canopy configuration. TKE was found to be the largest in the gap canopy configurations. TKE budget analysis revealed that buoyant production dominated over shear production. At the center of the heat patch, the gap canopy configurations showed enhanced buoyancy within the gap. These results improve our knowledge of fire-canopy-atmosphere interactions that can inform fire models on the impacts of canopy heterogeneity on plume dynamics and ember ejections.

54 ENVIRONMENTAL SCIENCES↗

Experimental investigation on heat transfer performance of drain water heat recovery heat exchangers

Water heating accounts for 18 % of residential energy consumption, and a substantial portion of this energy can be recovered through drain water heat recovery systems. Here, this paper investigates the heat transfer performance of drain water heat recovery heat exchangers. Two heat exchanger configurations were studied: vertical (gravity film exchanger) and horizontal. The heat recovery performance of the exchangers was quantified using sensible effectiveness and characteristic curves following the ε-NTU approach. Depending on the flow conditions, heat exchangers with a vertical configuration offered higher heat transfer effectiveness compared with the horizontal configuration under similar operating conditions. Furthermore, the results showed that properly designed and sized heat exchangers can effectively recover considerable amounts of waste heat from drains, depending on flow rates. Additionally, in the vertical heat exchanger configuration, low flow rates result in partially wet conditions, resulting in lower heat transfer effectiveness. Therefore, two distributor configurations are proposed to improve the heat transfer performance of vertically configured heat exchangers at low flow rates. The proposed distributor configurations and data presented in this paper will be useful in the design and development of drain water heat recovery systems in building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance evaluation of finned tube heat exchanger using curved wavy delta winglet vortex generators with circular perforations

Vortex generation is recognized as an effective passive approach to improve the heat transfer rate in fin and tube heat exchangers (FTHEs). The current study proposed innovative designs of curved wavy delta winglet vortex generators (CWDWVGs), both without and with circular perforations, to improve the heat transfer efficiency of FTHEs. There is potential to increase heat transfer performance further through various CWDWVG designs. Here, this study explores seven unique CWDWVG configurations, from 1-wave to 7-wave. A 3-D computational numerical model is utilized to evaluate the Thermo-hydraulic performance of FTHEs fitted with these different CWDWVG configurations across Reynolds numbers from 400 to 2000. This comparative analysis of the Thermo-hydraulic performance of FTHEs featuring four parallel circular tube layouts assesses configurations both with and without vortex generators (VGs) and various hole configurations. The evaluation of Thermo-hydraulic performance involves different parameters, including the London area goodness factor (LAGF), Colburn factor (j), friction factor (f), pressure drop (?P), and Nusselt number (Nu). Results demonstrate that the various CWDWVG configurations and the number of holes in them substantially affect the efficiency, as evaluated by the dimensionless Performance Evaluation Criteria (PEC). Notably, the 7-wave CWDWVGs surpassed other configurations, and integrating circular punched perforations further improved the thermal-hydraulic performance of FTHE. Specifically, the 7-wave CWDWVGs without holes demonstrated superior performance over other configurations, showing a significant increase in Nusselt number by 75.18% and 85.16% at Reynolds numbers of 2000 and 400, respectively, alongside an increase in pressure drop by 216.38% to 224.96%. Meanwhile, the 7-wave CWDWVGs with eight holes, in comparison to those without holes, exhibited a Nusselt number increase of 0.85%, a pressure drop decrease of 7.31%, and a reduction in the friction factor by 5.82%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Plasma rotation and diamagnetic drift effects on the resistive wall modes in the negative triangularity tokamaks

Abstract It was found previously that the negative triangularity (NT) configuration is more MHD-unstable for low n modes than the positive triangularity (PT) case, although the situation is reversed for intermediate n modes and the NT configuration becomes more stable for intermediate n modes ( n = 3 − 10 ) (Zheng et al 2021 Nucl. Fusion 61 116014). Here, n is the toroidal mode number. In this work, we extend the studies to include the rotation effects, as well as the diamagnetic drift effects, to see how the resistive wall modes (RWMs) in the NT configuration are affected as compared with the PT configuration. This is particularly motivated by noting that the wall interface with the plasma is quite different between the NT and PT configurations. It affects the plasma rotation and diamagnetic drift effects on the low n RWM. We consider the DIII-D-NT-experiment equilibrium reconstructed by the EFIT code. Based on the equilibrium g-file, the extended equilibria are constructed with the VMEC code by varying the beta values while keeping the pressure and poloidal current flux profiles basically unchanged. The bootstrap current contribution to the equilibria is taken into account with the Sauter formula. The MHD stability is then computed using the AEGIS code with the rotation and diamagnetic drift effects taken into account. We found that, although the NT configuration is less stable for n = 1 MHD modes, the rotation and diamagnetic drift stabilization effects on RWMs are more effective in the NT configuration than in the PT one. Note that even in the PT case, the stabilization of RWMs by the rotation and kinetic effects is critical. Because the low-n RWMs in the regular NT case are more unstable, the rotation and diamagnetic drift stabilization effects found in this research are important for the NT tokamak concept.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated Turbine Component Cooling Designs Facilitated by Additive Manufacturing and Optimization

This research program involved the development of improved gas turbine cooling by optimizing the combined internal and film cooling configurations used for turbine blades and vanes. Improved cooling of turbine airfoils allows the gas turbines to be operated at higher temperatures which improves efficiency for gas turbine-based power generation. This also facilitates operation with hydrogen-based fuels which inherently generate higher operating temperatures. Designs of the new cooling configurations were based on the added geometric flexibility that is available when using metal additive manufacturing techniques. When making these designs, adjustments were made to account for imperfections occurring in the metal additive manufacturing process. New designs for film cooling holes were developed using computational adjoint gradient optimization techniques which generated a unique film cooling hole with 70% greater film cooling effectiveness compared to conventional shaped film cooling holes. A major factor in improving the film cooling effectiveness were small external protrusions on either side of the new hole which generated vortices that pushed coolant towards the surface and increased the lateral spreading of the coolant. Our studies also included optimization of film cooling holes that can be built with conventional manufacturing techniques and optimizing the internal coolant channels that supply coolant to the film cooling holes. Various internal coolant channel shapes were investigated and designs that maximized the cooling of the airfoil while minimizing pressure losses in the channel flows were identified. Testing and verification of the performance of the final configurations was done with a transonic wind tunnel facility which allowed testing at engine realistic high velocities. Final testing of the combined internal and film cooling configurations was done by incorporating the configurations in Penn State’s National Experimental Turbine (NExT) vane. These tests confirmed the enhanced overall cooling effectiveness provided by the new cooling configuration designs.

03 NATURAL GAS↗

Quantifying Error in Photovoltaic Installation Metadata: Preprint

In this research, we quantify the level of metadata error for a fleet of 2860 photovoltaic (PV) systems, using metadata values provided by fleet owners. Using satellite imagery and time series analysis techniques available in open-source Python packages Panel-Segmentation and PVAnalytics, respectively, we evaluate the accuracy of PV system metadata such as location, azimuth, tilt, and mounting configuration (fixed tilt vs. tracking). We find that approximately 75% of provided latitude-longitude coordinates are within 190 meters of the actual solar installation. We were unable to link 7.8% of latitude-longitude coordinates to any solar installation via satellite imagery analysis. We evaluate the level of error in owner-provided mounting configuration (fixed tilt vs. single-axis tracking), finding only 8 systems with an incorrect mounting configuration. When evaluating azimuth and tilt parameters, we find that approximately 64% of the data is correct, with data for 860 systems (approximately 30%) not provided by system owners. To illustrate the importance of having correct solar metadata, we evaluate how incorrect metadata affects solar performance estimates by modeling system AC energy output at ground-truth vs. incorrect latitude-longitude coordinates, mounting configurations, and azimuth-tilt configurations. Energy output estimates can vary significantly if incorrect metadata parameters are used, with incorrect mounting configuration leading to the largest discrepancy with over 20% variation in expected energy output.

azimuth↗

Local convection characteristics of inline arrangement of Kagome-shaped unit cells in a square duct

Transient liquid crystal thermography experiments have been conducted to determine detailed convective heat transfer coefficients at the endwalls of lattice-frame configurations based on Kagome-shaped unit cells. Kagome unit cells with porosity of 0.88 were arranged in an inline manner, where two such arrangements were studied. In the first arrangement, a total of ten unit cells were placed next to each other along the streamwise direction resulting in a continuous configuration. In the 2nd arrangement, alternate unit cells from the continuous configuration were dropped, resulting in a discrete configuration which featured a total of 5 Kagome unit cells. Due to the asymmetric nature of the strut connections within the unit cell, the convective heat transfer coefficient maps were determined for the two opposite walls where the struts meet the endwalls. Transient liquid crystal experiments were conducted for Reynolds number ranging between 10,000 and 30,000. Here, the study was focused on the developing nature of flow along the streamwise direction and the local convection characteristics for continuous and discrete arrangement of unit cells. For the continuous configuration, the Nusselt number ratios (N u /Nu 0 ) varied between 3.15–3.46 and 2.75–2.89 for the two walls A and B, respectively. For the discrete configuration, convective heat transfer coefficients varied between 2.56–2.71 and 2.09–2.40 for the two walls. Kagome unit cells have the potential to be fabricated through inexpensive manufacturing routes such as wire-woven method and these unit cells find their applications in the areas which require different heat transfer levels on opposite walls.

Kagome↗

Confinement of quasi-atomic structures in Ti 2 N and Ti 3 N 2 MXene electrides

Metal carbides, nitrides, or carbonitrides of early transition metals, better known as MXenes, possess notable structural, electrical, and magnetic properties. Analyzing electronic structures by calculating structural stability, band structure, density of states, Bader charge transfer, and work functions utilizing first principle calculations, we revealed that titanium nitride MXenes, namely Ti 2 N and Ti 3 N 2 , have excess anionic electrons in their lattice voids, making them MXene electrides. Bulk Ti 3 N 2 has competing antiferromagnetic (AFM) and ferromagnetic (FM) configurations with slightly more stable AFM configuration, while the Ti 2 N MXene is nonmagnetic. Although Ti 3 N 2 favors AFM configuration with hexagonal crystal systems having 6/ mmm point group symmetry, Ti 3 N 2 does not support altermagnetism. The monolayer of the Ti 3 N 2 MXene is a ferromagnetic electride. These unique properties of having non-nuclear interstitial anionic electrons in the electronic structure of titanium nitride MXene have not yet been reported in the literature. Density functional theory calculations show TiN is neither an electride, MXene, or magnetic.

Anionic electrons↗

Combined effects of horizontal and vertical resolution on reliable turbulence prediction at tidal energy sites: A systematic study in the Salish Sea, WA

Predicting turbulence characteristics with coastal ocean models is essential for tidal energy converter deployment. While large eddy simulation provides a detailed turbulence representation, computational limitations restrict its use to smaller domains. We systematically evaluate whether well-configured coastal models can provide reliable turbulence prediction through progressive refinement of 3D model representation. We implemented four model configurations (Levels 1–4) using terrain-following coordinates, isolating the impacts of horizontal resolution, vertical resolution, and layer distribution. We validated all configurations against field measurements from the Salish Sea, WA. Results show that tidal current velocity predictions remain unchanged regarding model configuration, but turbulence properties are sensitive to resolution refinement. Increasing vertical resolution alone proved insufficient; even with vertical sigma-levels rising from 11 to 41, significant underprediction persisted until finer horizontal resolution better captured bathymetric variations. The Level 4 configuration, incorporating geometric sigma-levels distribution, achieved turbulence prediction skill scores exceeding 0.90. Turbulence closure comparison revealed Mellor- Yamada 2.5 outperformed k-epsilon in TKE prediction (skill scores 0.84–0.94 versus 0.72–0.81) due to better boundary layer parameterization. This study shows that well-configured coastal models effectively bridge the gap between simplified tools and costly high-fidelity modeling, offering the tidal energy industry practical and cost-effective turbulence data at commercially relevant scales.

Marine Energy↗